Tender For R&M Of Shed , False Ceiling, Painting Work Of Civil Division Office And Miscellaneous Work Of Circle Office And Mpts Office At Sakatpura, Kota
Tender Value
13.97 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
7 days left
EMD
27940
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kota → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for R&M Of Shed , False Ceiling, Painting Work Of Civil Division Office And Miscellaneous Work Of Circle Office And Mpts Office At Sakatpura, Kota
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal of rubbish lead up to 50 Mtr. and lift up to 1.5 Mtr.: All kinds of soil(B-1.28) |
| 2 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) B-13.1 |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. (A) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)(B-3.2.2) |
| 4 | (B-3/3.2.6) Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M20 grade Nominal Mix All up to plinth level1:4:8 (1Cement :4 Course Sand :8 Graded stone aggregate 40 mm nominal size |
| 5 | B-5/5.15.2 Brick work with clay flyash F.P.S. brick (IS 13757- 1993 ) of class designation 75 in superstructure above plinth level upto floor five level in :Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 6 | Plaster on new surface on walls in cement sand mortar 1:6 including racking of joints etc. complete fine finished 20mm thick.(B-12.3.2) |
| 7 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade \\"including all scaffolding: Old work (one or more coats) including scrapping surface and necessary repairs.\\" Same colour (B-12/ 12.37.2(b)) |
| 8 | New work (one or more coats) including scrapping and priming coat with cement primer\\" (B-12/ 12.37.1) |
| 9 | Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete New Plastered Surface (three or more coats) B-12.22.1 |
| 10 | __do__Old Plastered Surface (two or more coats) (B-12.22.2) |
| 11 | Painting exterior surface of Wall with 100% acrylic exteriorpaint of approved brand and manufacture to give an evenshade with two or more coats including prepartion of base with sand papering, primer, putty, etc complete in all respect including scaffolding and safety provision . Old Work (B-12.43.2) |
| 12 | ___do____New Work (B-12.43.1) |
| 13 | Painting with enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work. (B-12/12.46.2) |
| 14 | Two or more coats on new work (B-12/12.46.1) |
| 15 | Removing aluminium/Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.(B-14.57) |
| 16 | Providing and fixing of false ceiling with grid of M.S.tube section of size 19mm X 19mm and with a wall thickness of 1mm+/- 0.2mm.The side pipe and the intermediate pipes is fixed to the roof from the top with the help of ceiling angles/wire grid shall be covered by the uPVC profile section of size 6mm X 250mm with wall thickness of 0.80mm +/- 0.2mm,with the help of self tapping screw of 6mm X 13mm, 6mm X 19mm.Necessary cutouts for electric connections, lighting, air conditioning etc, shall be provided at required place. The perimeter edge shall be covered by extruded PVC corner beading section of size 9mm X 28mm or 25mm X30mm with a wall thickness of 1mm+/-0.2mm fixed by applying cynoacrylic adhesive complete as per manufacturer’s specification and direction of Engineer-in-charge. B-16.21 |
| 17 | Dismantling roofing including ridges, hips, valleys and rafters etc. and stacking the within 50 meter lead of: Asbestos Sheet. B-14.28.2 |
| 18 | Providing ridges or hips of width 60 cm over all width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia. G.I. limpet and bitumen washers complete.0.80mm thick with zinc coating not less than 275 B-10.4.1 |
| 19 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape whenever required. 0.80 mm thick with zinc coating not less than 275 gm/m2(B-10.1.2) |
| 20 | Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting fixing in position and applying a priming coat of approved steel primer all complete above plinth level up to 4.50 m height in R.S joist flats, tees, angles and channels.: (B-9.2) |
| 21 | B-16/16.6.1 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece M.S. With stainless steel cover plate |
| 22 | Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @ 0.253 kg/sqm.b) laying second layer of Fiber glass cloth when the first layer is still green . Overlaps of joints of fiber cloth should not be less than 10 cm .c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proffing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all aroundd) fourth and final layer of brick tiling ‘with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured (B-15.4) |
| 23 | Providing and fixing Almirah lock (50 to 70 mm size )of approved make without pair of handles for door with necessary screws etc complete as per direction of Engineer-in-charge. B-8.33 |
| 24 | Providing & Fixing drawer handle of approved make for drawers with screws complete as per approved by engineer in B-8.42 |
| 25 | Providing and fixing of double leaf steel shutter for cupboard, the frame is made of pressed steel ISI section 80x25 mmx 1.25 mm thick with 1.00 mm MS sheet to spot welded including holdfasts of 15x3mm, MS oxidized fittings such as butt hinges, sliding doors bolts, handles, tower bolts and twin peg etc complete including applying priming coat of approved steel primer of red oxide zinc chromate and spray painting in approved shade with deco paint of approved quality complete as per direction of Engineer In Charge (B- 9.39) |
| 26 | Repair of existing steel glazed doors,windows and ventilator,MS sheet door,garge doors,compound wallgatesetc.bywelding drillingcomplete include.Cost of welding rods and hire charge of welding meachine and TP etc complete(B-13.23) |
| 27 | LABOUR charges for repair to door/window without using any MATERIAL such as applying randha(finishing) tightening of bolts & screw etc.(b-13.24) |
| 28 | Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20% (B-1.34) |
| 29 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor. With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (B-1.35.3) |
| 30 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment). B-9.13 |
| 31 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:Of area 3 square meter and below. B-14.12.1 |
| 32 | Providing and fixing aluminum work for doors ,windows, ventilators and partition with extruded built up standard tubular / appropriate Z sections and other sections of approved make conforming to IS :733 and IS :1285, fixed with rawl plugs and screws or with fixing clips ,or with expansion hold fasteners including necessary filling up of gap. at junctions , at top ,bottom and sides with required PVC/neoprene felt etc. Aluminium section shall be smooth ,rust free, straight ,mitered and jointed mechanically wherever required including cleat angle Aluminium snap beading for glazing /paneling , C.P. brass/ stainless steel screws Al. Tower bolt & Al. handle & Al. Aldrop etc.,all complete as per architectural drawings and the directions of Engineer- in – charge .(Glazing and paneling to be paid for separately). (A.) For fixed portion Polyster Powder coating aluminum ( minimum thickness of powdercoating 50 micron) B-16.1.1.3 |
| 33 | ___Do___ (B.) For shutters builtup standard tubular sections of openable doors ,windows & ventilators including providing & fixing hinges / rollers etc. and making provision for fixing of fittings wherever required (lockes shall be paid for separately). Polyster Powder coating aluminum ( minimum thickness of powdercoating 50 micron) (B-16.1.2.3) |
| 34 | Providing and fixing glazing in aluminium door, window ,ventilator shutters and partitions etc. with PVS / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.(Cost of aluminium snap beading shall be paid in basic item.) With glass panes of 4.0 mm thickness ( weight not less than 10.0 kg/sqm) as per IS : 2835. (B-16.5.1) |
| 35 | Providing and fixing expanded grill made of aluminum as per design and drawing having members section of size 7.5mm x 6.0mm and opening of size 102mm x 99mm to aluminum window/vent with required screws, Y and H aluminium section (as per drawing) at the ends and middle joints respectively complete in all respect as per direction of engineer in charge.Polyester Powder coating aluminum ( minimum thickness of powder coating 50 micron)) B-16.10.3 |
| 36 | Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038- 1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concrete block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Partly fixed and partly openable [ fixed area not to exceed 33%] B-9.19.4 |
| 37 | Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance.(B-9.26) |
| 38 | Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 meter lead:For thickness of tiles 10mm to 25 mm B-14.23.1 |
| 39 | Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles conforming to IS : 13753 and IS 15622 of size 200mm x 300 mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar).(B-7/7.12) |
| 40 | Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm comfirming to IS : 13755 and IS 15622 colour suchas white, grey, ivory, fume red brown , light green light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4 ) (B-7/7.13) |
| 41 | Providing and fixing external grade board, solid core single leaf flush door shutters IS: 2202-67 marked using phenol formal dehydreresin glue both sides with approved steel fitting complete as per annexure 'A' 30mm thick commercial veneer both side(B-8.13.2.1) |
| 42 | B-33/8.4.2.3 Providing and fixing fully panelled/partly panelled/ double leaf shutter frame for doors as per approved design and drawings with approved ordinary C.P./ oxidised steel fittings as per Annexure - 'A' and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200mm width including teak wood beading of size 19mm x 12mm on both faces complete :30 mm thick Shesham wood grade I |
| 43 | Extra for providing external lipping with 2nd class teak wood battens 6 mm minimum depth on all edges of shutters (over all area of door shutter to be measured) Over item no. 8.13. (B-8.14) |
| 44 | Providing and fixing Nigeria / Ghana teak wood grade-I moulding and beadings in doors and windows size 50x12mm (B-8.23.1) |
| 45 | Supplying and fixing in walls machine cut and polished stone shelves, tands and in CM 1:3 with machine cut edges :Sand or other approved stone 50mm thick. |
| 46 | wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, 1.2 mm thick MS box with earth terminal of required size, 6 A switch, 3/5 pin 6 A socket, 3.0 mm thick ISI marked (IS:2036-1995) phenolic laminated sheet, Al.alloy / Cadmium plated iron/ brass screws, cup washers, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSRShort point (up to 3 mtr.) E-1.7.2 |
| 47 | Medium point (up to 6 mtr.) E-1.7.3 |
| 48 | (E-1/1.12.1) S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 20 mm |
| 49 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 1.5 sq. mm. E-4.1.2 |
| 50 | 2 x 2.5 sq. mm. + 1x1.5sqmm E-4.1.7 |
| 51 | Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . LED Street Light fixture with Minimum lumen output 8100 lm E-18.12.4 |
| 52 | E17/17.151.1 SITC of IP20, 2'x2' LED Surface/ Recessed mounting backlit & SMD Mid power type LED Light fixture not less than 35 mm housing depth made from CRCA sheet steel housing, high purity / transmissivity UV stabilized non-yellowish diffuser for uniform light distribution. operating voltage range 140-285 V, HV cutoff - LV cutoff should be 300-100V. High efficiency with 4 KV internal surge protection BIS certified isolated driver having efficiency > 85%, with Short & Open circuit protection (input 320VAC-48 hours protection, input 350VAC-2 hours protection) (Integral with light fixture). System lumen efficacy of ≥ 120 Im/Watt, THD < 10 %, p.f.20.95,CRI >80, life time of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends, CCT 3000°K/ 4000°K /5700°K /6000°K/6500°K (As per ANSI Bin) as required. Recessed Mounting .Minimum lumen output 4320 lm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender