Housing Urban and Rular Development Government Departments Closing in 4 days TDR #57762434

Tender For Construction Of Additional Accommodation In G.S.S. School Misserwala, Tehsil Paonta Sahib, District-Sirmour Hp Sh:-Construction Of Two Rooms With Verandah And Staircase At First Floor & Second Floor & Balance Work Of Ground Floor Under ( P

Issued by Government Departments · Shimla, Himachal Pradesh
Tender Value
1.99 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
4 days left
EMD
4000
Bank guarantee accepted
Document Fee
350
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Shimla → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Additional Accommodation In G.S.S. School Misserwala, Tehsil Paonta Sahib, District-Sirmour Hp Sh:-Construction Of Two Rooms With Verandah And Staircase At First Floor & Second Floor & Balance Work Of Ground Floor Under ( Pmjvl) (Sh:-Providing electrical installation Therein)

BOQ

Name of Work:- Construction of Additional Accommodation in G.S.S. School Misserwala, Tehsil Paonta Sahib, District-Sirmour HP SH:-Construction of Two Rooms With Verandah and staircase at First Floor & Second Floor & Balance Work of Ground Floor Under ( PMJVL) (SH:-Providing EI Therein)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
2Group C
3Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
4Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
5Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
72 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
82 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
92 X 10 sq. mm + 1 X 6 sq. mm earth wire
10Supplying and drawing following sizes of FRLS/HFFR/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
113x1.5 Sq.mm.
123x2.5 Sq.mm.
13Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
14Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
15Supplying and fixing electrical switch board, having 3 No. of 5 amp. switches and socket on suitable size of metal box of 75mm deep 12 module (200mmX150mm) on surface or in recess with suitable modular sheet cover in the front i/c providing and fixing 3 No. 5 pin 5/6 amp socket outlet and 5/6 amp modular type switch, connection, painting etc.as req. (For light plugs).Make:- havells, Anchor or any other approved by the Engineer in Charge .
16S/E of LED Batten with aluminium extrusion housing The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings.
17Specification of LED fittings:-
18Wattage of LED fittings :-As per following parameter.
19Total lumens of the fittings. :-as below
20Diffuser :-Polycarbonate diffuser/PMMA
21Operating voltage :-140 V to 270 V, AC supply or better.
22Input frequency :-50 Hz + 1 Hz
23Power factor :-Minimum 0.90
24Luminaire efficacy :->110 lm/w
25Color rendering index:-CRI shall be greater than 80
26Working/ operating temperature :-0ºC to + 45º C or better
27Color temperature :-6000ºK + 10%
28Electronic Driver :-
29Drive current (LED):-As per OEM.
30Operating voltage :-140 V to 270 V AC supply or better
31Type of driver :-Constant current output driver
32THD :-Less than 10%
33Surge Protection :-2.5 KV minimum
34Efficiency Driver:->85%
35Protection:-Shall have under voltage and over voltage protection.
36Guarantee of LED fittings including LED driver :-5 years against manufacturing defect.
37Fixture :-Should comply with LM 79 test from UL/NABL lab.
38LED Type/ Make/ Model:-Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
39Life of LED:-50000 burning hours at 70% lumen maintenance
40LED Batten Light (2200 Lm)
41LED Batten Light (4400 Lm)
42S/E of LED Downlighter square type with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings.
43Specification of LED fittings:-
44Wattage of LED fittings :-As per following parameter.
45Lumen output of the fitting :-as below
46Diffuser :-Polycarbonate diffuser/pmma
47Operating voltage :-140 V to 270 V, AC supply or better.
48Input frequency :-50 Hz + 1 Hz
49Power factor :-Minimum 0.90
50Luminaire efficacy :->100 lm/w
51Color rendering index :-CRI shall be greater than 80
52Working/ operating temperature :-0ºC to + 45º C or better
53Color temperature :-6000ºK + 10%
54Electronic Driver :-
55Drive current (LED) :-As per OEM.
56Operating voltage :-140 V to 270 V AC supply or better
57Type of driver :-Constant current output driver
58THD :-Less than 10%
59Surge Protection :-2.5 KV minimum
60Efficiency Driver :->85%
61Protection :-Shall have under voltage and over voltage protection.
62Guarantee of LED fittings including LED driver :-5 years against manufacturing defect.
63Fixture :-Should comply with LM 79 test from UL/NABL lab.
64LED Type/ Make/ Model :-Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
65Life of LED :-50000 burning hours at 70% lumen maintenance
66Round LED Down Light ( 1500 Lm)
67Supply, Installation, Testing and Commissioning of following sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.85, Air delivery minimum 215 CMM, 300 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote/ BLDC electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
68Ceiling Fan 1200 mm sweep
69Ceiling Fan 1400 mm sweep
70Supplying and fixing Metal fan box as required complete in all respect as per statifaction of Er-in- charge etc .
71Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
72Single pole
73Supplying and fixing following rating, followings poles 10ka 240/415v 'C' curves miniature circuit braker suitable for inductive load of following poles in the exsisting MCB DB complete with connections, testing and commissioning etc. as required.
7440 A DP
75Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
768 way , Double door
77Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57762434
AUTHORITY Government Departments
TENDER VALUE 1.99 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Additional Accommodation In G.S.S. School Misserwala, Tehsil Paonta Sahib, District-Sirmour Hp Sh:-Construction Of Two Rooms With Verandah And Staircase At First Floor & Second Floor & Balance Work Of Ground Floor Under ( Pmjvl) (Sh:-Providing electrical installation Therein)
Basic Detail
Tender No Electrical Division-I dated 28.09.2026
Bidding Type Tender
Location
City Shimla
State Himachal Pradesh
Key Dates
Publish Date 28 Sep 2026
Submission Date 05 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 1.99 Lakhs
Tender Fee 350
EMD 4000
Exemption Not Available
Document List
BOQ_215077.xls
DeclarationNEW.pdf
f0e41ad2-6f77-4f8f-92ae-b6b908afa8db.html
SBD_15_Misserwala.pdf
Tendernotice_1 (22).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_215077.xls

pdf

DeclarationNEW.pdf

html

f0e41ad2-6f77-4f8f-92ae-b6b908afa8db.html

pdf

SBD_15_Misserwala.pdf

pdf

Tendernotice_1 (22).pdf