Tender For Construction Of Additional Accommodation In G.S.S. School Misserwala, Tehsil Paonta Sahib, District-Sirmour Hp Sh:-Construction Of Two Rooms With Verandah And Staircase At First Floor & Second Floor & Balance Work Of Ground Floor Under ( P
Tender Overview
Project Description
Tender for Construction Of Additional Accommodation In G.S.S. School Misserwala, Tehsil Paonta Sahib, District-Sirmour Hp Sh:-Construction Of Two Rooms With Verandah And Staircase At First Floor & Second Floor & Balance Work Of Ground Floor Under ( Pmjvl) (Sh:-Providing electrical installation Therein)
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group C |
| 3 | Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required. |
| 4 | Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 5 | Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 7 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 8 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 9 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 10 | Supplying and drawing following sizes of FRLS/HFFR/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 11 | 3x1.5 Sq.mm. |
| 12 | 3x2.5 Sq.mm. |
| 13 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 14 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 15 | Supplying and fixing electrical switch board, having 3 No. of 5 amp. switches and socket on suitable size of metal box of 75mm deep 12 module (200mmX150mm) on surface or in recess with suitable modular sheet cover in the front i/c providing and fixing 3 No. 5 pin 5/6 amp socket outlet and 5/6 amp modular type switch, connection, painting etc.as req. (For light plugs).Make:- havells, Anchor or any other approved by the Engineer in Charge . |
| 16 | S/E of LED Batten with aluminium extrusion housing The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 17 | Specification of LED fittings:- |
| 18 | Wattage of LED fittings :-As per following parameter. |
| 19 | Total lumens of the fittings. :-as below |
| 20 | Diffuser :-Polycarbonate diffuser/PMMA |
| 21 | Operating voltage :-140 V to 270 V, AC supply or better. |
| 22 | Input frequency :-50 Hz + 1 Hz |
| 23 | Power factor :-Minimum 0.90 |
| 24 | Luminaire efficacy :->110 lm/w |
| 25 | Color rendering index:-CRI shall be greater than 80 |
| 26 | Working/ operating temperature :-0ºC to + 45º C or better |
| 27 | Color temperature :-6000ºK + 10% |
| 28 | Electronic Driver :- |
| 29 | Drive current (LED):-As per OEM. |
| 30 | Operating voltage :-140 V to 270 V AC supply or better |
| 31 | Type of driver :-Constant current output driver |
| 32 | THD :-Less than 10% |
| 33 | Surge Protection :-2.5 KV minimum |
| 34 | Efficiency Driver:->85% |
| 35 | Protection:-Shall have under voltage and over voltage protection. |
| 36 | Guarantee of LED fittings including LED driver :-5 years against manufacturing defect. |
| 37 | Fixture :-Should comply with LM 79 test from UL/NABL lab. |
| 38 | LED Type/ Make/ Model:-Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 39 | Life of LED:-50000 burning hours at 70% lumen maintenance |
| 40 | LED Batten Light (2200 Lm) |
| 41 | LED Batten Light (4400 Lm) |
| 42 | S/E of LED Downlighter square type with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. |
| 43 | Specification of LED fittings:- |
| 44 | Wattage of LED fittings :-As per following parameter. |
| 45 | Lumen output of the fitting :-as below |
| 46 | Diffuser :-Polycarbonate diffuser/pmma |
| 47 | Operating voltage :-140 V to 270 V, AC supply or better. |
| 48 | Input frequency :-50 Hz + 1 Hz |
| 49 | Power factor :-Minimum 0.90 |
| 50 | Luminaire efficacy :->100 lm/w |
| 51 | Color rendering index :-CRI shall be greater than 80 |
| 52 | Working/ operating temperature :-0ºC to + 45º C or better |
| 53 | Color temperature :-6000ºK + 10% |
| 54 | Electronic Driver :- |
| 55 | Drive current (LED) :-As per OEM. |
| 56 | Operating voltage :-140 V to 270 V AC supply or better |
| 57 | Type of driver :-Constant current output driver |
| 58 | THD :-Less than 10% |
| 59 | Surge Protection :-2.5 KV minimum |
| 60 | Efficiency Driver :->85% |
| 61 | Protection :-Shall have under voltage and over voltage protection. |
| 62 | Guarantee of LED fittings including LED driver :-5 years against manufacturing defect. |
| 63 | Fixture :-Should comply with LM 79 test from UL/NABL lab. |
| 64 | LED Type/ Make/ Model :-Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. |
| 65 | Life of LED :-50000 burning hours at 70% lumen maintenance |
| 66 | Round LED Down Light ( 1500 Lm) |
| 67 | Supply, Installation, Testing and Commissioning of following sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.85, Air delivery minimum 215 CMM, 300 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote/ BLDC electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 68 | Ceiling Fan 1200 mm sweep |
| 69 | Ceiling Fan 1400 mm sweep |
| 70 | Supplying and fixing Metal fan box as required complete in all respect as per statifaction of Er-in- charge etc . |
| 71 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 72 | Single pole |
| 73 | Supplying and fixing following rating, followings poles 10ka 240/415v 'C' curves miniature circuit braker suitable for inductive load of following poles in the exsisting MCB DB complete with connections, testing and commissioning etc. as required. |
| 74 | 40 A DP |
| 75 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 76 | 8 way , Double door |
| 77 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender