Tender For Reinforcement Of Fatudihi Rl Lip Under Samakhunta Block In Mayurbhanj District
Tender Value
11.17 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
7 days left
EMD
11171
Bank guarantee accepted
Document Fee
7080
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mayurbhanj → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Reinforcement Of Fatudihi Rl Lip Under Samakhunta Block In Mayurbhanj District
BOQ
| Sl. No. | Item Description |
| 1 | E/Work in excavation in hard soil in Fdn. Including rough dressing & levelling the bed not exceeding 0.30 m depth as per specification |
| 2 | Filling in F&P with sand wall watered and rammed. |
| 3 | C.C. (1:4:8) with 40mm size of h.g. metal. |
| 4 | Filling in F&P with excavated materials. |
| 5 | CC (1:2:4) with 12mm size C.B. chips including hoisting and laying |
| 6 | Brick masonary in cm (1:6) in foundation & plinth.(Fly Ash) |
| 7 | 12mm thick cement plaster over brick works. |
| 8 | Rigid and smooth centering & shuttering for RCC works including tales works after dismantlling then after centering including cost of all materials-Slab,Chajah |
| 9 | Labour for M.S.reinforcement for RCC works including cost of M.S.Rod, cutting, bending,binding & tying the grills and placing in position. |
| 10 | Cement Punning |
| 11 | Fabricated Display board M.S.Sheet with writing Charges |
| 12 | Cost of outlet |
| 13 | 200x200x100 mm dia G.I Outlet Tee weldless long radiuos made out of GI socket Medium 300 mm long with ID 200 mm ID (Suitable for Insert directly 200 mm dia PVC Pipe / HDPE Pipe with minimum 100 mm long inside the GI socket ) Fitted with 1.95 Mtr long 100 mm dia GI Pipe as per IS 1239 Part-1 or IS - 1161 welded with 2 nos 100 mm dia GI flange in between the 1.95mtr GI pipe as per IS 1239 part-1 or IS 1161 bending with long radius GI Pipe in 90 Degree (Bending 90 Degree long radius both side without welding ) water locking arrangements made out of 1 no of 100 mm dia open flange and 1 No of 100 mm dia Blind flange with hings gaskets arrangements for waterlocking system. |
| 14 | Cost of supply 30 CM sly wrench-1 No, 5/8 Ring wrench-1 No, DE spanner-1/2-1 No, 30 CM Screw driver-1 No, Insulated plier-1 No (TAPARIA MAKE) |
| 15 | Laying & fitting of 200 mm dia UPVC pipes (Cl-I ) in under ground including excavation of trench of size (0.75 M x 1.00 M) in proper alignment & filling the trench after fitting of the pipes including cutting of heaps and making the base of the trench uniformely sloping & laying for of the pipes in uniform gradient including supply of jointing materials like solvent cement etc.and also fixing the PVC \\"Tee\\", PVC Reducers , PVC Bends , N.R.Valves of different sizes at required places along the pipe line including transportation of materials to the work site etc.complete as per the direction of the Site Engineer in Charge. |
| 16 | Rigid UPVC pipe of 200 mm dia Ivory grey in colour having specific gravity of 1.4 to 1.46 Gm/CC of straight length of 6 M for portable water supplies confirming to IS 4985 / 2021 of BIS-Amendment-2 Read with Table-I, of IS specification bearing ISI mark for working pressure of 2.5 Kgf / Cm² Class-I as per latest ammendment of IS 4985 including cost of coupler for plain ended pipes or one end plain and other bell ended. The pipe should be tested by CIPET and each pipe should be clearly & indelible marked ink or Stenciled confirming to ISI 4985/2021. |
| 17 | Installation of 15 HP Pumpsets & Pannel board on the fixed foundation , fitting of the starter, Main switch , Kit Kats, connecting the Tropodar cable with Main supply line in under ground by digging Cable trench and filling it after laying of Cable line, connecting the Pannel board with the Motor, Fixing the motor cover including transportation of Materials to Work site etc. complete as per the direction of the Site Engineer in Charge. |
| 18 | Empty Outdoor Irrigation Pannel Board size (0.45 Mtr x 0.25 Mtr x 1.20 Mtr) of 18 SWG cold rolled MS sheet with 4 legs of 300 size with one coat of Red Oxide primer and two coats of smoke grey / navy blue two coats of powder coated pain of approved quality onn both side (Inside & Outside) suitable to mount 3Phase Starter, Main Switch and Capacitor inside the Panel Board vertically over 18SWG MS Sheet and the danger board fixed on the top of the panel Door reputed brand of ISI specification including all cost conveyance, cess etc complete but excluding GST. |
| 19 | Motor hood size (0.45 Mtr x 0.45 Mtr x 0.60 Mtr) made with SWG (Cold rolled MS Sheet with one coat of red oxide Primer and two coats of powder coated paint of approved quality on both side (inside & Outside) suitable to cover centrifucal Monoblock Pump set from 10 HP to 15 HP and having provision for attachment with the grooves on rear side of the panel board of approved brand including all cost, conveyance, cess etc complete as per the direction of the Engineer-in-charge but excluding GST. |
| 20 | Base frame for Panel (size 0.40 Mtr x 0.20 mtr) made with 3 size M.S Chanel having suitable holes for fitting of panel board, coloured with one coat of red oxide primer and two coats of powder coated paint of approved quality and base frame for motor (size 0.50 Mtr x 0.27 Mtr) made with 3 size M.S Chanel having suitable holes for fitting of different size and make 3 phase centrifucal monoblock pump set from 10 HP to 15 HP coloured with one coat red oxide primer and two coats of powder coated paint of approved quality reputed brand of ISI specification including all cost conveyance, cess etc complete but excluding cost of GST. |
| 21 | 100mm dia Nominal Bore G.I.Pipe having wall thickness 4.5 mm, Electrical resistence welded , Medium Class confirming to IS 1239 ( Pt) - 1 / 2004) with latest ammendment screwed at both ends as per IS 554 with socketed at one end and other end protected with plastic thread protector. The socket confirming to IS - 1239 (Pt)-II / 1992 ) with latest ammendment with random length of 4 to 7 M & should bear ISI certification and manufacturer Trade marks. |
| 22 | 100mm dia G.I.Bend confirming to IS No. 1239 (Pt-II/1992) |
| 23 | 100 mm dia C.I. Screw Base Foot valve of swing type friction less with single disc confirming to IS-4038/1979 of reputed brand with ISI mark of reputed company having wide dealersip network including all cost conveyance, cess etc complete but excluding cost of GST. |
| 24 | 100 mm dia Screw Boss Flange confirming to IS No. 6392 /19 71 |
| 25 | 200 mm dia PVC End cap (W . P) (10 Kg / Cm²) confirming to IS 4995/1988 with latest ammendment |
| 26 | M.S Nut Bolt (5/8x1') |
| 27 | Cost supply of 3 mm thick Rubber Insertion including all cost conveyance, cess etc complete but excluding cost of GST. |
| 28 | 50 mm dia C.I. Air Release Valve PN-1.6 with shaddle and riser pipe IS 14845 (SI) |
| 29 | 100x100x25 mm dia G.I.Raiser Tee with Plug for priming |
| 30 | 200 x 100 mm dia PVC Reducer |
| 31 | 200x200x200 mm dia PVC Equal Tee |
| 32 | Cutting , threading of 100 mm dia G.I.Pipes to proper size with required length making leak proof for flow of water and fitting it in proper position including transportation of Materials to Work site etc. complete as per the direction of the Site Engineer in Charge. |
| 33 | 15 HP / 11.25 KW Energy Efficience Monoblock Pump set of total head 24 trs having discharge 1700 LPM with squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges and class \\"F\\" insulation suitable for operation 415 volt + 6% -15% 3 Phase, 50Hz AC power supply suction / delevery = 100mm x 100mm with BEE 3 star rated energy efficiency pump & as per IS 9079/2002 with overall efficience 62 to 65 % of reputed brand having wide dealership net work for easy availability of spares confirming to IS specification (a) Casing : FC 200 as per IS 210/1978 (b) Impeller : Bronze grade LTB-2 of IS 318/1981 including all cost conveyance, cess etc completed but excluding cost of GST |
| 34 | Automatic Star Delta Starter of sheet Steel enclosure suitable for operation of squirrel cage Induction Motor up to 15 HP (13-20) with 16 AMP ( AC-3) contactor at 415 Volt + 6% - 15% , 3 phase 50 Hz , A.C supply with suitable Over Load Relay & no volt coil with electric pnemutic timer suitable for operation at voltage range of 300-440 Volt including cost of transportation to site. The starter should provide dependable protection against overload and single phasing & should be of reputed brand having wide dealership network for easy availability od spares including all cost, Coveyance, cess etc complete but excluding GST. |
| 35 | 63 Amp Triple Pole Main Switch confirming to IS No-4064 (Part-1 & 2) with ISI Marking of reputed company having utilisation capacity category AC-22 reputed brand of ISI specification including all cost conveyance, cess etc complete but excluding GST. |
| 36 | 3 Core x 10mm² Insulated ( HD ) Tropoted armoured Electric Cable with Alluminium conductor for use in 3 phase power system of working voltage up to and including 1100 Volts at 50 Hz confirming to IS 7098 (Pt - 2 ) of approved brand of ISI Marked including all cost conveyance, cess etc complete but excluding cost of GST. |
| 37 | 4.0 mm² PVC Single core Copper wire with ISI mark of reputed approved brand of ISI Marked including all cost conveyance, cess etc complete but excluding cost of GST. |
| 38 | Installation of Starter, Capacitor, fitting of 63 AMP Kit Kat, jointed with Troppodar cable to main supply line & substation cable with making cable trench including transportation all complete as per the direction of the site Engineer in charge.. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender