Tender For Replacement Of Existing Led Fittings Installed At City Side & Air Side Including Vehicular Lane, Staircase Level, Highmasts Etc. At Chennai Airport.
Tender Value
1.74 Crore
Estimated cost
Bid Submission
21 Oct 2026
14 days left
EMD
3.48 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Replacement Of Existing Led Fittings Installed At City Side & Air Side Including Vehicular Lane, Staircase Level, Highmasts Etc. At Chennai Airport.
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Installation, Testing and Commissioning of Symmetric High Bay LED light fixture of minimum system lumen output of 22,500 lumens, minimum system efficacy of 175 lm/watt, pressure die cast aluminium body with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 90°, Built in Driver with surge protection ≥ 6 KV, along with 2.5m length of suitable size flexible copper wire, capable to operate with input voltage of 140-270V, 50Hz AC Supply, THD < 10%, P.F. ≥ 0.95, IP 65, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including supply and fixing of suitable anchor fastener with safety chain for mounting the light fixture (Double Secure), provision of Bird spike etc. complete as required as per the technical specifications with minimum 07 years OEM warranty. |
| 2 | Supply, Installation, Testing and Commissioning of Recessed Canopy High bay LED light fixture of minimum system lumen output of 10,500 lumens, minimum system efficacy of 120 lm/watt, pressure die cast aluminium body with effective thermal managment, embossed name/logo name of manufacturer, having 60° symmetric beam angle, Built in Driver with surge protection ≥ 4KV, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP66, IK ≥07, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including provision of safety chain, modification / replacement of existing false ceiling material made of Aluminium of size 2ft x 2ft to match the proposed new fitting etc. complete as required as per the technical specifications with minimum 07 years OEM warranty. |
| 3 | Supply, Installation, Testing and Commissioning of Symmetric High bay LED light fixture of minimum system lumen output of 10,000 lumens, minimum system efficacy of 180 lm/watt, pressure die cast aluminium body with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 90°, Built in Driver with surge protection ≥ 6KV, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 65, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including supply and fixing of suitable clamping arrangement with safety chain for mounting the light fixture (Double Secure), provision of Bird spike etc. complete as required as per the technical specifications with minimum 07 years OEM warranty. |
| 4 | Supply, Installation, Testing and Commissioning of Symmetric High bay LED light fixture of minimum system lumen output of 10,000 lumens, minimum system efficacy of 180 lm/watt, pressure die cast aluminium body with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 90°, Built in Driver with surge protection ≥ 6KV, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 65, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including supply and fixing of anchor fastener with safety chain for mounting the light fixture (Double Secure), provision of Bird spike etc. complete as required as per the technical specifications with minimum 07 years OEM warranty. |
| 5 | Supply, Installation, Testing and Commissioning of Symmetric LED Flood light fixture of minimum system lumen output of 56,000 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4 KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 30°, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including providing and fixing of connector for connection, complete etc. as required as per the technical specifications with minimum 07 years OEM warranty. |
| 6 | Supply, Installation, Testing and Commissioning of Symmetric LED flood light fixture of minimum system lumen output of 27,900 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, having beam angle 60°, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP-66, IK ≥07, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including providing and fixing of connector for connection, complete etc. as required as per the technical specifications with minimum 07 years OEM warranty. |
| 7 | Supply, Installation, Testing and Commissioning of Symmetric LED Flood light fixture of minimum system lumen output of 24,000 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 60°, toughened glass cover plate over the LED to prevent dust accumulation, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥07, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including providing and fixing of connector for connection, complete etc. as required as per the technical specifications with minimum 07 years OEM warranty. |
| 8 | Supply, Installation, Testing and Commissioning of Symmetric LED Flood light fixture of minimum system lumen output of 12,000 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, having minimum beam angle 60°, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥07, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including supply and fixing of anchor fasteners for mounting the light fixture, provision of Bird spike, providing and fixing of connector for connection complete etc. as required as per the technical specifications with minimum 07 years OEM warranty. |
| 9 | Supply, Installation, Testing and Commissioning of LED Street light fixture of minimum system lumen output of 16,800 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K including provision of suitable flange arrangement to enable the fixing in the bracket arm of existing street light pole complete etc. as required as per the technical specifications with minimum 07 years OEM warranty. |
| 10 | Supply, Installation, Testing and Commissioning of LED Street light fixture of minimum system lumen output of 8,400 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K including provision of suitable flange arrangement to enable the fixing in the bracket arm of existing street light pole complete etc. as required as per the technical specifications with minimum 07 years OEM warranty. |
| 11 | Supply Installation Testing and Commissioning of surface mounted LED Batten light of minimum 4,300 Lumens Capacity, minimum lumen efficacy 120 lm/Watt output, Poly Carbonate body, Operating voltage of AC 140-270 Volt, 50Hz, internal surge protection ≥ 4 KV, THD < 10%, P. F. ≥0.95, IP65, IK 07, CRI ≥70, life time of minimum 50000 Burning Hours @L70B50, CCT of 5700K, SDCM(Standard Deviation Color Matching) <5 complete etc. as required as per the specifications with Minimum 07 year OEM warranty. |
| 12 | Supply Installation Testing and Commissioning of 2ft x 2ft surface/recess mounted LED fixture of minimum 4320 Lumens Capacity, minimum lumen efficacy 120 lm/Watt, CRCA housing, Operating voltage of AC 140-270 Volt, 50Hz, internal surge protection of ≥ 2 KV, THD < 10%, P. F. ≥0.95, IP20, IK 04, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, life time of minimum 50000 Burning Hours @ L70B50, CCT of 6500K, SDCM(Standard Deviation Color Matching) <5 complete including safety chain etc. as required as per the specifications with Minimum 07 year OEM warranty. |
| 13 | Supply and fixing of 25mm dia medium class PVC conduit along with accessories in surface/recess including cutting wall and making good the same in case of recessed conduit as required. |
| 14 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.3 x 2.5 Sq.mm |
| 15 | Dismantling the existing old light fixtures (Flood lights, Highbay & Street Light fixtures) and shifting the same to AAI Store or any location as per the instructions of Engineer -in-Charge. |
| 16 | Dismantling the existing old light fixtures (Batten light and 2ft X 2 ft light fixtures) and shifting the same to AAI Store or any location as per the instructions of Engineer -in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 29, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 21, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer