Civil Aviation Boards / Undertakings / PSU Closing in 14 days TDR #57761577

Tender For Replacement Of Existing Led Fittings Installed At City Side & Air Side Including Vehicular Lane, Staircase Level, Highmasts Etc. At Chennai Airport.

Issued by Boards / Undertakings / PSU · Chennai, Tamil Nadu
Tender Value
1.74 Crore
Estimated cost
Bid Submission
21 Oct 2026
14 days left
EMD
3.48 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Existing Led Fittings Installed At City Side & Air Side Including Vehicular Lane, Staircase Level, Highmasts Etc. At Chennai Airport.

BOQ

Name of Work:- Replacement of existing LED fittings installed at City side & Air side including Vehicular lane, Staircase level, Highmasts etc. at Chennai Airport.
Sl. No. Item Description
1Supply, Installation, Testing and Commissioning of Symmetric High Bay LED light fixture of minimum system lumen output of 22,500 lumens, minimum system efficacy of 175 lm/watt, pressure die cast aluminium body with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 90°, Built in Driver with surge protection ≥ 6 KV, along with 2.5m length of suitable size flexible copper wire, capable to operate with input voltage of 140-270V, 50Hz AC Supply, THD < 10%, P.F. ≥ 0.95, IP 65, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including supply and fixing of suitable anchor fastener with safety chain for mounting the light fixture (Double Secure), provision of Bird spike etc. complete as required as per the technical specifications with minimum 07 years OEM warranty.
2Supply, Installation, Testing and Commissioning of Recessed Canopy High bay LED light fixture of minimum system lumen output of 10,500 lumens, minimum system efficacy of 120 lm/watt, pressure die cast aluminium body with effective thermal managment, embossed name/logo name of manufacturer, having 60° symmetric beam angle, Built in Driver with surge protection ≥ 4KV, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP66, IK ≥07, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including provision of safety chain, modification / replacement of existing false ceiling material made of Aluminium of size 2ft x 2ft to match the proposed new fitting etc. complete as required as per the technical specifications with minimum 07 years OEM warranty.
3Supply, Installation, Testing and Commissioning of Symmetric High bay LED light fixture of minimum system lumen output of 10,000 lumens, minimum system efficacy of 180 lm/watt, pressure die cast aluminium body with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 90°, Built in Driver with surge protection ≥ 6KV, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 65, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including supply and fixing of suitable clamping arrangement with safety chain for mounting the light fixture (Double Secure), provision of Bird spike etc. complete as required as per the technical specifications with minimum 07 years OEM warranty.
4Supply, Installation, Testing and Commissioning of Symmetric High bay LED light fixture of minimum system lumen output of 10,000 lumens, minimum system efficacy of 180 lm/watt, pressure die cast aluminium body with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 90°, Built in Driver with surge protection ≥ 6KV, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 65, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including supply and fixing of anchor fastener with safety chain for mounting the light fixture (Double Secure), provision of Bird spike etc. complete as required as per the technical specifications with minimum 07 years OEM warranty.
5Supply, Installation, Testing and Commissioning of Symmetric LED Flood light fixture of minimum system lumen output of 56,000 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4 KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 30°, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including providing and fixing of connector for connection, complete etc. as required as per the technical specifications with minimum 07 years OEM warranty.
6Supply, Installation, Testing and Commissioning of Symmetric LED flood light fixture of minimum system lumen output of 27,900 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, having beam angle 60°, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP-66, IK ≥07, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including providing and fixing of connector for connection, complete etc. as required as per the technical specifications with minimum 07 years OEM warranty.
7Supply, Installation, Testing and Commissioning of Symmetric LED Flood light fixture of minimum system lumen output of 24,000 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, having beam angle of 60°, toughened glass cover plate over the LED to prevent dust accumulation, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥07, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including providing and fixing of connector for connection, complete etc. as required as per the technical specifications with minimum 07 years OEM warranty.
8Supply, Installation, Testing and Commissioning of Symmetric LED Flood light fixture of minimum system lumen output of 12,000 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, having minimum beam angle 60°, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥07, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K etc. including supply and fixing of anchor fasteners for mounting the light fixture, provision of Bird spike, providing and fixing of connector for connection complete etc. as required as per the technical specifications with minimum 07 years OEM warranty.
9Supply, Installation, Testing and Commissioning of LED Street light fixture of minimum system lumen output of 16,800 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K including provision of suitable flange arrangement to enable the fixing in the bracket arm of existing street light pole complete etc. as required as per the technical specifications with minimum 07 years OEM warranty.
10Supply, Installation, Testing and Commissioning of LED Street light fixture of minimum system lumen output of 8,400 lumens, minimum system efficacy of 130 lm/watt, pressure die cast aluminium body with built in integrated driver with internal surge protection ≥ 4KV & external surge protection 10KV, with effective thermal managment, embossed name/logo name of manufacturer, capable to operate with input voltage of 140-270V, 50Hz AC supply, THD < 10%, P. F. ≥ 0.95, IP 66, IK ≥08, CRI ≥70, life time of minimum 50,000 burning hours @L70B50, CCT of 5700K including provision of suitable flange arrangement to enable the fixing in the bracket arm of existing street light pole complete etc. as required as per the technical specifications with minimum 07 years OEM warranty.
11Supply Installation Testing and Commissioning of surface mounted LED Batten light of minimum 4,300 Lumens Capacity, minimum lumen efficacy 120 lm/Watt output, Poly Carbonate body, Operating voltage of AC 140-270 Volt, 50Hz, internal surge protection ≥ 4 KV, THD < 10%, P. F. ≥0.95, IP65, IK 07, CRI ≥70, life time of minimum 50000 Burning Hours @L70B50, CCT of 5700K, SDCM(Standard Deviation Color Matching) <5 complete etc. as required as per the specifications with Minimum 07 year OEM warranty.
12Supply Installation Testing and Commissioning of 2ft x 2ft surface/recess mounted LED fixture of minimum 4320 Lumens Capacity, minimum lumen efficacy 120 lm/Watt, CRCA housing, Operating voltage of AC 140-270 Volt, 50Hz, internal surge protection of ≥ 2 KV, THD < 10%, P. F. ≥0.95, IP20, IK 04, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, life time of minimum 50000 Burning Hours @ L70B50, CCT of 6500K, SDCM(Standard Deviation Color Matching) <5 complete including safety chain etc. as required as per the specifications with Minimum 07 year OEM warranty.
13Supply and fixing of 25mm dia medium class PVC conduit along with accessories in surface/recess including cutting wall and making good the same in case of recessed conduit as required.
14Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit as required.3 x 2.5 Sq.mm
15Dismantling the existing old light fixtures (Flood lights, Highbay & Street Light fixtures) and shifting the same to AAI Store or any location as per the instructions of Engineer -in-Charge.
16Dismantling the existing old light fixtures (Batten light and 2ft X 2 ft light fixtures) and shifting the same to AAI Store or any location as per the instructions of Engineer -in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57761577
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 1.74 Crore
LAST DATE 21-10-2026
Authority
Authority Name Airports Authority Of India
Work Description Tender for Replacement Of Existing Led Fittings Installed At City Side & Air Side Including Vehicular Lane, Staircase Level, Highmasts Etc. At Chennai Airport.
Basic Detail
Tender No AAI_CHE_AMED-II_2026_2
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 29 Sep 2026
Submission Date 21 Oct 2026
Open Date 23 Oct 2026
Finance
Tender Value 1.74 Crore
Tender Fee 1180
EMD 3.48 Lakhs
Exemption Not Available
Document List
15115226-115a-493e-892c-dfa98c6dd3cd.html
BOQ_341081.xls
Tendernotice_1.pdf
Tender_Document.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

15115226-115a-493e-892c-dfa98c6dd3cd.html

xls

BOQ_341081.xls

pdf

Tendernotice_1.pdf

pdf

Tender_Document.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders