Housing Urban and Rular Development Government Departments Closing in 12 days TDR #57761433

Tender For Provision Of Internal And External Electrification Arrangements To The New Integrated Commercial Taxes Office Building At Tiruchengode In Namakkal District.

Issued by Government Departments · Namakkal, Tamil Nadu
Tender Value
65.14 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
12 days left
EMD
43500
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Namakkal → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provision Of Internal And External Electrification Arrangements To The New Integrated Commercial Taxes Office Building At Tiruchengode In Namakkal District.

BOQ

Name of Work:- Provision of Internal and External Electrification arrangements to the New Integrated Commercial Taxes Office Building at Tiruchengode in Namakkal District.
Sl. No. Item Description
1Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End )
2Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End )
3Wiring with 3 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plate and making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Higher End.
4Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (HigherEnd) complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting.
5Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End) complete with conduit pipe suspension from the ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with tube.
6Supply and fixing of 9W LED Lamp for BH point.
7Supply and fixing of 18W LED square type Recessed fitting with LED (Higher end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting.
8Supply and fixing of WT bulk head fitting with guard suitable for 15 W LED Bulb.
9Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1no. 32mm GI bend complete on the existing post/on wall with PVC unsheathed copper leads with MS clamps and with painting.
10Supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 600 mm fan down rod on exisitng fan clamp.
11Supply and fixing of 300mm (12\\") sweep (Heavy duty) AC exhaust fan complete without provision of hole in the wall
12Supply and fixing of louvers shutters arrangements for 300mm (12\\") sweep (light duty) AC exhaust fan.
13Supply and fixing of 3nos.6A two module 3 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
14Supply and fixing of 1 no. 6/16A two module socket, 1 no.16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End
15Supply and fixing of 25A flush type wall socket with 25A DP MCB complete set for AC plug in flush with wall with earth connection.
16Supply and fixing of 32A 2P MCB in sheet steel enclosure box with electrical connections complete.
17Supply and fixing of 32A 4P MCB in sheet steel enclosure box with electrical connections complete.
18Supply and fixing of 63A FP MCB in Metal box DP enclosure in flush with wall and making good of the concealed portion with earth connection. (Higher End)
19Supply and fixing of 125A TPN switch disconnector fuse units in sheet steel enclosure with HRC fuses double brEak on suitable angle iron frame work with MS cable entry boxes with Earth connection only.
20Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End (Lift room -1 no.)
21Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB switch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
22Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
23Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 2 nos. 32A 3P MCB , 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Higher End
24Supply , Erection Testing and commissioning of 415V/50 HZ 125A Cubicle Panel board with centre switches Chamber the bus bar chamber and cable chamber on extreme end with 16 SWG thick CRCA sheet with 1”x 1/4 ” copper flats for 3 phases and neutral with 6mm hylem sheet separation of 3 phases and neutral and with synthetic moulded insulators bus supports at equal intervals as per IS specification and 2 runs of 1”x 1/8” copper flat on either side of the panel board for Earth buses , 3 Nos LED pilot lamps set withfuse base, top & 10A HRC Fuse link for 3 phases 1 No Digital multifunction meter on a separate Chamber and with the following switches complete as per Electricity regulation authority 2023 norms.Incoming125A TPN switch disconnector fuse interior only with HRC fuses double break -1 NoOutgoing 100A TPN switch disconnector fuse interior only with HRC fuses double break -2 Nos.63A TPN switch disconnector fuse interior only with HRC fuses double break -8Nos
25Supply and fixing of 100 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with Earth connection only.
26Supply and fixng of TNEB meter board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2\\" x 1-1/2\\" x 1/4\\" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1\\" x 1/4\\" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete.
27Supply and fixing of 3 phase 100A aerial fuse unit for 3 Nos. 200A fuse units (500V) on suitable MS sheet covered with 6mm thick hylem sheet on suitable angle iron work the tapping pole with necessary clamps.
28Supply and fixing of 65mm (2-1/2\\") GI pipe (Class 'B') of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonary pedestal with painting of suitable colour.
29Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion.
30Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion.
31Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 6 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion.
32Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 16 sq.mm. PVC insulated SC unsheathed FRLS copper wire with painting of suitable colour.
33Supply and Laying of 3 1/2 x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
34Supply and Laying of 3 1/2 x 50 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
35Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
36Supply and clarnping of 3 1/2 x 25 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.
37Supply and clarnping of 3 1/2 x 50 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.
38Supply and clarnping of 3 1/2 x 70 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps.
39Supply and clarnping of 3 1/2 x 70 sq.mm. PVC LTUG armoured cable in suitable GI pipe on post or on wall with MS clamps.
40Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection.
41Supply and frxing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection.
42Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection.
43Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
44Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
45Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete.
46Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
47Supply and run of 25mm x 3mm tinned copper flat with necessary clamps/supports on wall/floor/ground for earth connection.
48Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth Connection.
49Design, Engineering, Fabrication, Supply, Erection, Testing, Commissioning and handing over of 13 Persons capacity Passenger lift in Tiruchengode CTO (Gearless Lift with Machine Room, Passenger Lift with M/C room, Speed 1.5 m/s with Stainless Steel Panels, Disable friendly, microprocessor based controller, VVVF drive, Fire rated doors and ARD.) complete with the following specifications I. GeneralNumber of Lift : 1 No(a) Capacity and type : 13 Persons (884kg) Capacity Passenger lift. (b) Speed : 1 Mtr / Sec.(c) Drive : Micro Processor based VVVF (d) Size of Lift well : 2570 x 1900 (MM Wide x MM Depth) as per IS 14665 (partI) 2000 (e) No. of floors : 4 (Ground + 1 st floor + 2nd floor + 3rd floor) (f) Total height of Travel : 15200mm/ PIT 1600mm/ Head Room 4200mm.(g) No.of stops: 4 ( Ground + 3Upper Floor)(h) No.of opening : 4 ( Ground + 3Upper Floor)(i) Construction of lift well : R.C.C. with brick masonry.(j) Power supply : AC 415/ 440 Volts, 3phase, 50 Cycles.(k) Auxiliary supply : 230V, AC supply (Single phase)(l) Position of machinery : Directly above the lift well-Gearless.(m) Lift pit depth : 1600mm(n) Leveling accuracy : High level accuracy with smooth & jerk free travel and stopping.II. CARa. Size of Lift Car inside : 2000mm width x 1100mm x 2200mm (MM Wide * MM Depth * MM Height)b. Design of lift car: Stainless Steel
50c. Car ceiling : Sleek (Small circular Lights).d. Car floor : Grey- 20mm Reccess.e. Car fittings : Stainless steel illuminating push button and 7 seagments digital position indicator and overload indicator, 220V A/C electric fan 300mm swing, CFL fittings, UPS operated emergency alarm and light, floor announcement with musics, ADR function announcement.f. No. of Opening : One in front onlyg. Car Entrance : One in front onlyPower Operated centre opening sliding door Pre-Coated steel-Grey.h. Clear opening : 900 x 2000 (mm Wide x mm Height)III. ENTRANCE a. Car Door : Power Operated centre opening sliding door-Pre-Coated steel-Grey.b. Landing Entrance Doors: Centre opening sliding door-Pre-Coated steel-Grey.c. Type of Entrance Frame: Stainless steelIV. OPERATION Microprocessor based Simplex Selective Collective control with/ without attendant. V. Car and Landings : Digital floor position indicator in car and all landing. Dry cell operated alarm bell and emergency light with Automatic charging device, Up/ Down Digital direction indications at all landings and in car.VI. LADDER FOR LIFT MACHINERY: To be provided by the Lift contractor.
51VII. SPECIAL FEATURE :Digital position indicator in Car and landings. Battery operated Emergency light and Alarm bell, call register signal and VF Door operator, false ceiling in Car. Infra red door screen, Vandal proof SS Button with SS cover/ Automatic Rescue Device, Over load indication, Fire mans switch, over load indicator and Intercom provisions with Instruments and floor Annuciator.SS hand rails and ON/ OFF key and free service for 1year.VIII. Automatic Rescue Device (ARD):To facilitate landing of lift to the nearest floor at the time of power failure. This shall consist of suitable type battery system with charger, inverter, under voltage protection system etc. complete with all accessories.IX. MINOR BUILDER WORK : To be done by the lift contractor.X. SCAFFOLDING WORKS : To be done by the lift contractor.XI. FREE SERVICE AND MAINTENANCE DURING THE GUARANTEE PERIOD OF ONE YEAR & SAFTY CERTIFICATEa. Guarantee : Guarantee for materials and workmanship of equipment not less than one year.b. Free maintenance : Free comprehensive, servicing and maintenance during the guarantee period to be provided by the Lift contractor (1year). Including replacing of Batteries, ARD under fault occation during the One year free maintenance period. And important necessary training of employees, for minor maintenance works and proper handing over of lift to be done by the lift contractor.C. Preparation of Drawings and obtaining CEIG's Safety Certificate for lift approval as per lift act with payement of necessary fees to CEIG and insurance policies. If any applicable to lift.
52e. Time of closing of door should not be more than 5sec and the closing speed should not exceed 0.25m. Sec.f. Crab bar should be placed at a height of 900mm from the floor level at both side and rear side of the lift.g. Site tests in accordance with IS 14665-2000 shallbe carried out at time of handing over.XII. OTHER INCLUSIONS :Battery operated emerency light and alarm bell, Call register signal and VF door operator, Door open and door close button, auto attendent key, Auto light & fan switch off (pod), push button- orange LED illumination, Dot Matrix LED D&P findicators in car & Landing- orange colour, floor annuciator firemans switch, false ceilling in car, infra red door screen, Overload wanring indicator, full load bypass, scaffoldin, two way intercom with press & speak in cop free service for one year unloadingchargespit ladder, SS handrail, Provision for Physically handicapped, Sill support, Lift license, Fascia plates& Support angle for fascia plate, StainlessSteel Braille button with S.S. Cover, Provision for CCTV CAmera- IP (Cat6 Flat travelling cable)
53DIESEL GENERATOR SETSupply, testing, commissioning and handing over of 1No, 58.5KVA Diesel Generator Set with acoustic enclosure conforming to CPCB IV+ Norms and BIS Specifications of as detailed below.A) ENGINE :Water cooled diesel engine suitable for generator application with a shaft out put of 310 BHP suitable at 1500 RPM under NTP conditions. The engine shall comprise the following standard scope of supply: 1) Dry type Air cleaner. 2) Expansion bellow. 3) Radiator, radiator fan and mounting. 4) Air to air charge cooler. 5) Exhaust gas turbo charger. 6) Lube oil cooler and lube oil filter. 7) Fuel filter (pre and micro). 8) In-line mono-block fuel injection pump with governor and fuel feed pump. 9) Electronic governor. 10) 12V/ 24V battery charging alternator. 11) 12V/ 24V Volt electric starter motor. 12) Engine test certificate. 13) Residential Mufler. 14) Fly wheel with starter ring. Engine instrument panel/ mounting: Engine control panel consisting of ON/ OFF/ START/ KEY, lube oil pressure gauge, oil temperature gauge, high water temperature gauge and electronic hour meter and RPM indicator. Safety system of Engine: The engines shall trip for the following conditions with Visual alarm device. 1) Low lubricating oil pressure. 2) High water temperature . 3) Vee - belt failure and over speed. 4) Low battery indication. The Engine should be capable of providing 10% over load for one hour for every 11 hours continuous running at full load.B) ALTERNATOR :58.5KVA/100KW capacity of Brushless Alternator AC 3phase, 50HZ, 415Volts, 0.8P.F, 4wire self exited,self regulated designto run at 1500 RPM under NTP conditions conforming to IS 13364 (part-II) 1992 to be coupled directly to the Diesel engine and test certificate
54C) AMF CONTROL PANEL: The AMF control panel (cubical) should be fabricated with vermin proof and dust proof best quality sheet steel and floor mounted with removable rear panels and hinged front doors with enamel painted and incorporating the following with suitable provision for connecting incoming and outgoing leads have been made on the control panel complete set.1) 1No AC Ammeter. 2) 3Nos current transformer with suitable Ratio. 3) 1No Ammeter selector switch. 4) 1No AC voltmeter. 5) 1No Voltmeter selector switch. 6) 1No Frequency meter. 7) 1No KWH meter. 8) 1No power factor meter. 9) 1No KW meter. 10) Battery charging set comprising of the following for charging the battery from mains. a) Transformer/ Rectifier, b) DC Ammeter, c) Charging rate selector switch, d) DC voltmeter, e) Circuit breaker, f) Voltage Regulator, g) ON/ OFF switch. This will be in addition to auxiliary neutral contactor for battery charging alternator fitted to the Engine.11) 1set Motorized Control for main supply, 12) 1set low voltage HRC fuse for the short circuit protection of the main supply. 13) 1set alternator contactor with auxiliary neutral contactor. 14) 1set three pole bimetal release for over load protection of the alternator. 15) 1set low voltage HRC fuse for the short circuit protection of the alternator. 16) 1set DC control relays incorporating engine start/ stop and failure to start/ lockout. 17) 1set selector switch auto/ manual. 18) 1No push button “Start”. 19) 1No push button “Stop”.20) 1No push button “Reset”. 21) 1No signal lamp for indicating load on mains. 22) 1No signal lamp for indicating load on set. 23) 1No signal lamp for indicating set fails to start . 24) 1No signal lamp for indicating ‘Set running’. 25) 1No signal lamp for indicating ‘Battery charger ON’. 26) 1set pilot lamps of 3Nos.
5527) MCCB of 100A capacity with magnetic thermal over load release, instant short circuit trip and under voltage release switch. 28) Rectangular copper bus bars for 200A (1No for each phase, neutral and earthing terminal) capacity duly colour coded with head shrinkable PVC sleeves. 29) 1No mains voltage monitor.30) Hooter/ Audio alarm for indication set fails to start and for DG O/ L.31) 1set timers. 32) Audio and visual indication arrangements for , a) Low lubricating oil pressure, b) High water temperature, c) Over speed. 33) 1No Earth fault relay. 34) Isolator to Isolate the neutral.Note:1. The control panel should be complete with necessary fuses, cables, labels, other accessories with neutral isolation arrangements. 2. The engine should trip for the following conditions. a) Low lubricating oil pressure, b) High water temperature, c) Over speed. 3.Supply and fitment of Auto mains failure panel to EB service with 100Amps switch and contactors with scuf control relays, timers etc.D) ACOUSTIC ENCLOSURE :Acoustic enclosure shall be powder coated and fabricated of 16SWG CRCA MS sheet. The silent canopy shall be nut bolt type construction. Critical processes of punching are done on CNC machine to maintain dimensional accuracy of hole within 0.1mm, powder coating done after seven-tank surface preparation process of sheet metal. Canopy panel and door shall have inside lining of FIRE-RETARDANT 64kg/m density mineral wool of 100mm thickness as acoustic material. Four hinged doors shall be provided to canopy. The maximum permissble sound pressure level should be as per the norms prescribed by the Central Pollution Control Board/ State Pollution Control Board/ Competent Authority concerened or shouble be within 75 db(A) at 1 meter from the enclosure surface whichever is advantageous to the department.
56The emergency stop should be available on the enclosure panel. The enclosure provided shall be duly approved by the Engine Manufacturer of the Engine provided for Diesel Generator Set mounted inside and should be to the satisfaction of inspection/ testing authority concerned.SURFACE TREATMENT–PAINTING:The enclosure shall be suitably treated for degreasing, de-rusting and phosphating. The canopies are passed through seven-tank treatment thoroughly. ADDITIONAL FEATURES OF CANOPIES :Canopy fabricated on CNC machines with dimensional accuracy of 0.1mm so as to increase its durability. Special designed supporting rips/structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any. WORLD CLASS COOLING PACKAGE: Canopies shall have cooling package for which it can perform at 45 deg C ambient temperature. No grounding required on the ground, only a level surface capable of with standing the DG weight. Lifting hooks shall be provided for the acoustic enclosure, which should be unloaded independently of the DG set. The Gen set frame shall also be provided with hooks for unloading.Temperature rise inside the canopy:Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at cleaner within the enclosure well with in 5-7 deg centigrade.
57D) Base FrameBase frame should be fabricated in sheet metal. The base frame is rugged in construction and Base frame should befabricated in sheet metal. The base frame is rugged in construction and designed for mounting engine and brush less alternator closely coupled, with cross members mounted on AVM. The base frame shall have provision for mounting of acoustic enclosure on it. The supply of Gen set includes loading, unloading and transportation charges. E) Fuel TankFuel tank of atleast 200Ltrs capacity shall be fabricated out of 14SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet and outlet connections and mechanical fuel gauge. It can be easily removed for cleaning and maintenance. First charging of fuel oil to full capacity and first charging of battery while handing over to the department. Also supply of fuel oil to run the genset for a minimum of 8 hours on load or by using rheostat.F) Battery1No. 12V 150 AH battery
58Erection of Gen set: Providing suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation for erection of 58.5KVA Diesel Generator set over the existing fountation and erection of generator set with proper alignment over the existing fountation to suit Genset fountation size.
59Supply and installation of exhaust piping of sufficient length with suitable MS pipe so as to extend outside the generator with necessary thermal insulation.
60Supply and Run of 12 core 2.5 sqmm armoured copper control cable FRLS signal cable in suitable PVC rigid pipe on wall/Ground/ ceiling with connection.
61GST 18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57761433
AUTHORITY Government Departments
TENDER VALUE 65.14 Lakhs
LAST DATE 14-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Provision Of Internal And External Electrification Arrangements To The New Integrated Commercial Taxes Office Building At Tiruchengode In Namakkal District.
Basic Detail
Tender No NIT 04 2026 27 B C M CIRCLE ERODE Dated 21.09.2026
Bidding Type Tender
Location
City Namakkal
State Tamil Nadu
Key Dates
Publish Date 29 Sep 2026
Submission Date 14 Oct 2026
Open Date 14 Oct 2026
Finance
Tender Value 65.14 Lakhs
Tender Fee Ref. Documents
EMD 43500
Exemption Not Available
Document List
b1de3b4d-5f09-4a36-b660-e04f2479551f.html
BOQ_851660.xls
Tendernotice_1 (22).pdf
Ten_Con_TgodeCTOElectrical.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

b1de3b4d-5f09-4a36-b660-e04f2479551f.html

xls

BOQ_851660.xls

pdf

Tendernotice_1 (22).pdf

pdf

Ten_Con_TgodeCTOElectrical.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender