Dairy Cooperative Closing in 21 days TDR #57759315

Tender For Civil Work Of Tmr Plant At Cfp Kaladera Tph) At Cattle Feed Plant, Kaladera

Issued by Cooperative · Jaipur, Rajasthan
Tender Value
2 Crore
Estimated cost
Bid Submission
21 Oct 2026
21 days left
EMD
4 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Civil Work Of Tmr Plant At Cfp Kaladera Tph) At Cattle Feed Plant, Kaladera

BOQ

Name of Work:- Civil Work of TMR plant at CFP Kaladera TPH) AT CATTLE FEED PLANT, KALADERA
Sl. No. Item Description
1PART-A -(BUILDING WORK)
2Earth Work
3Surface dressing of the ground including removing vegetation and inequalities not exceeding 15cm deep and disposal ofrubbish lead up to 50 Mtr. and lift up to 1.5 Mtr. : All kinds of soil
4Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal ofsurplus excavated soil as directed with in a lead of 50 meter.All kinds of soils. 0M TO 1.5M
5Add extra for foundation/trenches/drains for every additional lift of 1.5 Mtr. or part thereof inAll kinds of soil
6Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/Lindane emulsifiable concentrate of 20%
7Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which aproch is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion) .
8Filling available excavated earth (excluding rock) in trenches, plinth side of foundation etc. in layers not exceeding 20 cm. in depth, consolidating each deposited layer by ramming and watering including lead up to 50 meter and with all lift. 0 TO 1.5M
9Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand.
10Kharanaja
11Random rubble dry stone Kharanja under floor.
12Plain Cement Concrete
13Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6
14Renforced Cement Concrete
15Providing and laying in position Ready mix concrete manufactured in fully automatic Batching Plant and transported to site in transit mixer for having continous agitated mixer, manufactured as per approved mix design of specified grade of RCC work including pumping of R.M.C. from transit mixer to site of laying , exculding the cost of centering, shuttering and reinforcement with all lead and lift including cost of admixtures in recommended portion as per IS 9103 to accelerate/ retard setting of concrete, improveworkability without impairing strength and durability as per direction of Engineer in charge. All works upto floor V floor M20 grade Design Mix by using cement as per codal provision. Add extra for providing richer mixes respectively at all floor levels. Providing M-25 grade concrete by using cement as per codal provision instead of M-20 grade design mix.
16Centering and Shuttering
17Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc.
18Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blocks, sills, chhajjas, lintel, beam, plinth beam etc.
19Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel props and removal of formwork for upto floor five level for : Columns, pillars, posts and struts etc.
20Reinforcement
21Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level.Thermo-mechanically Treated bars (Conforming of relevent IS code)
22Random Rubble stone masonry
23Random Rubble stone masonry for with hard stone infoundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:3 ( 1-Cement : 3-Sand).
24Brick masonry
25Brick work with F.P.S. bricks of class designation 75 insuperstructure above plinth level upto floor V level in allshapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand)
26Plaster Work
27Plaster on new surface on wall in cement sand mortar 1:3 including racking of joints etc. complete fine finish : 20 mm thick
28Rough cast plaster upto 10m height above ground level with amixture of sand and gravel or crushed stone from 6mm to10mm nominal size dashed over and including the fresh plasterin two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) and top layer 10mm cement plaster 1:3 (1cement : 3 fine sand) mixed with 10% finely groundedhydrated lime by volume of cement.Ordinary cement finish using ordinary cement
29Putty & Painting Work
30Providing and applying white cement based putty overplastered surface to prepare the surface even and smoothcomplete.New Plastered Surface (three or more coats)
31Wall painting with plastic emulsion paint of approved bran and manufacture to give an even shade including allscaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
32Finishing walls with Acrylic Smooth exterior paint of requiredshade including all scaffolding.New work (Two or more coat applied @ 1.67 ltr/10 sqm overand including base coat of water proofing cement paint applied@ 2.20 kg/ 10 sqm ).
33Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
34Flooring Work (VDCC)
35Providing and laying M30 grade controlled cement concretepavements including mixing and vibrations concrete withnecessary needle vibrators and surface with screed boardvibrating complete in all respect with 20/25 mm stoneaggregate (crusher broken) including anti-skid textured finishto required camber/ super elevation and grade includingcuring etc. as per specification with cement concrete M-30grade including cost of Steel frame work for sides of C.C.pavement consisting of M. S. channels flats and angles withrequired steel pegs ( some of them may left embedded inconcrete/ including providing frame work)
36Extra for vacuum processed concrete including cost ofequipments labour etc.
37Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Good quality.South Zed Black.Above 3601 Cm2 Slabs.
38Extra for providing edge moulding to 15-18mm thick marble/ Granite/Kota stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. FULL Edge moulding
39UPVC Work (Door/Window/Ventilator)
40Providing and fixing of uPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, Laminated (colour) finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of laminated (colour) having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass
41Providing and fixing of openable uPVC Doors with or without fix top: Frame Made of Extruded uPVC Window Profile Section of size 60w x 70h mm having outer wall thickness of 2.75mm (+/- 0.2mm) and 3 box multi-chamber construction, Laminated (colour) finish, duly reinforced with 1.2mm thick GI section. All the corners shall be mitered cut & thermal welded so as to form door frame. Fix Mullion made of 60w x 80h mm uPVC Profile Section with steel reinforcement shall be provided for the top fix portion of the doors or in case of the doors having more than two openable shutters, as per the requirement / drawing. Frame of openable door shall have coextruded EPDM/TPE-E gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Shutter : The shutters of openable door shall be made of 60w x 95h mm Extruded 3 box multi-chamber uPVC Window Profile Section of laminated( colour) having outer wall thickness of 2.75mm (+/- 0.2mm) provided with reinforcement of 2.0 mm thick GI section duly mitered cut & thermal welded at all corners, provided with center mullion (if specified in drawing) of size 60w x 80h mm uPVC Profile Section and fitted with uPVC glazing bead of size 36 x 20mm with inner and outer co-extruded EPDM/TPE-E weather seal gaskets alongwith 6mm thick ISI make plain float glass. All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware: Each openable door shutters is to be fixed with three load beading butt hinges and locking of doors is to be provided with multi-point transmission gear (ESPAG) with white finish powder- coated lockable handle. Installation at site:
42Steel Work
43Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete:
44Rolling Shutters
45Supplying and fixing rolling shutters of approved make, made of 80 x 1.25mm. M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including cost of spring hooks, providing and fixing necessary 25.3cm. long wire springs grade No. 2 and M.S. top cover 1.25mm thick for rolling shutters as per design & IS 6248- 1979. (Clear openable area to be measured for payment).
46Providing & fixing ball bearing for rolling shutters
47Extra for providing mechanical device chain and crank operation for operating rolling shutters.Exceeding 10.00 Sqm and upto 16.80 Sqm in the area.
48PART-B -(ELECTRICAL WORK)
49Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's ISI marked (IS:3419- 1988)accessories, Hot Dipped Galvanized Modular box of 1.2 mm thick with earth terminal, 10 A modular switch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
50On board.
51Short point (upto 3 mtr.)
52Medium point (upto 6 mtr.)
53Long point (upto 10 mtr.)
54Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
552 x 1.5 sq.mm
562 x 2.5 sq.mm
572 x 4.0 sq.mm
58S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
5925 mm
60Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Single pole MCB (With B/C curve tripping Characteristics)
616 A to 32 A rating
62Providing & Fixing of 240/415 V isolator ISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage, true contact indication, Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting, minimum phase termination capacity of 35sq.mm. IP 20 contact protection and fitted in existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
63Double pole isolator 40A rating
64Double pole isolator 63 A rating
65Four pole isolator 63 A rating
66Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules,detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Metal door (single phase) IK-09 and IP-43 with Metal end box
678 Way (8+2)
68Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate/ Glass housing SMD Mid Power LED tube rod (with integral driver & alumn. heat sink ), on existing fixture. system lumen efficacy ≥ 100 lm/Watt output, internal surge protection of 2.5 KV ,THD < 20% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
691200mm , Min. Lumens output 2000 lm LED Tube rod with Polycarbonate Housing
70Providing & Fixing of IP 20 box made out from 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating and suitable for mounting LED tubeincluding side covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube). All as per pre approved by Engineer in charge. For additionaltechnical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
71Suitable for 4' LED Tube shape fixture for single rod
72Suitable for 4' LED Tube shape fixture for double rod
73Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %,round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
746.0 Sq. mm 3 core
7510.0 Sq. mm 3 core
76Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification of Wiring accessories refer Chapter E - 07 related item & For additional technical parameters of product / work refer Annexure 'A' attached with this BSR
77Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \\"A\\" attached with this BSR .
78High Power LED Flood Light Minimum lumen output 10000 lm
79SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided. (b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire. [c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra ) (d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR
80Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Electrolytic grade (Cu-ETP) Tin Coated annealed copper bus bars IACS 100% grade
81Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Three phase Ammeter with Inbuilt Selector Switch
82Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type (up to 500) V range Volt meter / Direct- Ammeter / CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracy as per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Three phase Voltmeter with Inbuilt Selector Switch
83Providing & Fixing of 110/220 V, unibody LED Indicating lamp IEC 60947 with integral circuit, IP 65 above panel & IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Red/yellow/Green colour
84SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For\additional technical parameters of product / work refer Annexure 'A' attached with this BSR.4 pole MCCB With Thermal Magnetic release up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
85Providing & Fixing of BEE Star rated copper wounded double ballbearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .1400 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 )
86Providing & Fixing of IP65 IK08 rated Integrated High power LED ( each LED between 3 to 5 watt power with secondary lencs on each LED) Highbay light fixture made from Pressure Die Cast Aluminium housing, toughned glass diffuser, potted driver, Eye bolt for mounting, system lumen efficacy ≥140 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 4 KV inbuilt & 10 KV external inside fixture. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .Minimum lumen output 10000 lm
87Providing and fiximg of turbo vantilators on the roofs of godowns both sheet roofs as well as rcc roofs complete including supply,transportation, labour charges of fixing complete as per direction of emgineer in charge
88Providing, fabricating, supplying and fixing Industrial Louvers complete with supporting framework, fasteners, sealant and all accessories as required at site, complete in all respects. Extruded Aluminium Alloy 6063-T5/T6 sections conforming to IS 733 and IS 1285 or approved equivalent. Aerodynamically designed fixed louvers inclined at 45° (or as per approved drawing) to provide maximum ventilation while preventing rainwater ingress.Blade Thickness: Minimum 1.2 mm. Frame Thickness: Minimum 1.5–2.0 mm. Frame Size: As per approved shop drawing and site requirement. Finish: Polyester powder coated with approved shade, minimum 60–80 microns DFT, conforming to IS 13871. Support Frame: MS galvanized supporting frame fabricated from suitable angle/channel sections, cleaned, primed with zinc-rich primer and finished with two coats of synthetic enamel paint, where required. Bird/Insect Mesh: Powder-coated aluminium or SS 304 wire mesh (minimum 18 × 16 mesh) fixed on the inner side of louvers. Fasteners: Stainless Steel (SS 304) screws, anchor fasteners, rivets and other fixing accessories. Weather-resistant silicone sealant at all joints and perimeter to ensure watertight installation. Wind Load: Designed to withstand wind loads as per IS 875 (Part 3).Installation: Installed true to line, level and plumb, including cutting, drilling, anchoring, grouting and making good damaged surfaces. Workmanship: All exposed surfaces shall be free from dents, scratches, sharp edges and visible defects. Adjustable opening shall consider
89Pre-Engineered Building (PEB STRUCTURE).
90Design, Engineering, Fabrication, Supply, Transportation, Erection, Alignment, Testing and Commissioning of Pre-Engineered Building (PEB) Mild Steel Structure, including all primary and secondary structural members, bracing systems, anchor bolts, connection plates, fasteners, painting, erection, and all accessories complete as per approved drawings, specifications, and direction of Engineer-in-Charge.Structural design bs qualified structural engineer.Preparation and submission of design calculations (As per seismic zone & wind Speed norms of the site location), GA drawings, fabrication drawings, shop drawings and erection drawings. Fabrication at factory. Transportation to site. Erection using cranes and required equipment. Alignment, plumbing and bolting. Welding wherever required. Supply of all nuts, bolts, washers, cleats, stiffeners and accessories. Surface preparation and protective coating. Testing and commPrimer paint: - One coat of Sunthlic Enamel based zinc chromate or zine phosphate (DF T=40 micronscoat].Finishing paint - Two coats of Synthetic Enamel cured finish (DFT =40 micronscoat]. TOTAL DFT 120 micron ASIAN, DULUX, BERGER or NEROLAC MAKE.
91Providing and fixing pre-painted galvalume steel (PPGL) sheets 0.5mm thick for roofing/wall cladding, including all necessary accessories, cutting, overlapping, drilling, fixing, sealing, transportation, handling, scaffolding and labour. PPGL sheets shall be manufactured from high-quality 55% Aluminium-Zinc alloy coated steel substrate conforming to relevant applicable BIS/IS standards.Self-drilling/self-tapping screws of approved quality with EPDM/neoprene washers.Complete as per drawings and instructions of the Engineer-in-Charge.Colour: As approved by the Engineer/Architect.Minimum yield strength: 550 MPa for roofing sheets.Coating: Minimum AZ150 (150 g/m² total both sides) or as specifiedPaint system: Factory-applied corrosion-resistant primer and top coat
92Providing, supplying, fabricating and fixing translucent polycarbonate skylight roofing complete with supporting framework, flashings, fasteners, sealing accessories and all associated works to provide natural daylight through the roof, complete in all respects as per approved drawings, manufacturer's specifications and the Engineer-in-Charge's instructions.Skylight sheet shall be 10 mm / 16 mm thick multi-wall polycarbonate sheet.Sheet shall have minimum 80% light transmission (for clear sheets) or as approved.Manufacturer shall provide a minimum 10-year warranty against yellowing, loss of light transmission and manufacturing defects.
93Providing, designing, manufacturing, supplying, transporting, installing, testing, and commissioning of Roof Monitor Ridge Ventilator for Pre-Engineered Building (PEB) complete with structural support frame, weatherproof side louvers, Roof monitor (1500MM Wide) bird peotection Mesh Considered translucent polycarbonate sheets (where specified), ridge capping, flashing, fasteners, sealants, gutters, bird/insect mesh, accessories, and all incidental works, as per approved drawings and the directions of the Engineer-in-Charge.
94FIRE FIGHTING WORKS
95\\"Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, G.I. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. a) 200 mm dia.\\"
96\\"Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, G.I. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. a) 150mm dia.\\"
97\\"Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, G.I. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. a) 100MM dia
98\\"Supply, Installation, Testing and Commissioning of the following sizes of flange jointed / screwed / welded, G.I. Pipes of Class C (Heavy class) ISI marked including accessories such as MS bracket, U clamps with Anchor fasteners, tees / elbows / reducers / couplings / unions / bends / flanges etc., and laying on the surface including painting with two coats of anticorrosive primer and two coats of approved red enamel paint after laying and testing after Installation etc. as per specifications complete as required. a) 80 mm dia.\\"
99\\"Supply, Installation, Testing and Commissioning of C.I. Y type Strainer with 30 mesh SS304 screen supported on 18 swg thick SS perforated sheet Size: 150 mm Dia.\\"
100\\"Supply, Installation, Testing and Commissioning of C.I. Y type Strainer with 30 mesh SS304 screen supported on 18 swg thick SS perforated sheet Size: 80 mm Dia.\\"
101\\"Supply, Installation, Testing and Commissioning of BFV valve (PN 1.6) with flanges, nut bolts, gaskets complete as required. a) 150 mm dia.\\"
102\\"Supply, Installation, Testing and Commissioning of BFV valve (PN 1.6) with flanges, nut bolts, gaskets complete as required. a) 100 mm dia.\\"
103\\"Supply, Installation, Testing and Commissioning of BFVvalve (PN 1.6) with flanges, nut bolts, gaskets complete as required. a) 80 mm dia.\\"
104\\"Supply, Installation, Testing and Commissioning of BFV valve (PN 1.6) with flanges, nut bolts, gaskets complete as required. a) 50 mm dia.\\"
105\\"Supply, Installation, Testing and Commissioning of swing type Cast iron Dual plate Non Return valve with EPDM lining ductile iron disc and stainless steel spring (PN 1.6) a) 150 mm Dia.\\"
106\\"Supply, Installation, Testing and Commissioning of swing type Cast iron Dual plate Non Return valve with EPDM lining ductile iron disc and stainless steel spring (PN 1.6) a) 100 mm Dia.\\"
107\\"Supply, Installation, Testing and Commissioning of swing type Cast iron Dual plate Non Return valve with EPDM lining ductile iron disc and stainless steel spring (PN 1.6) a) 50 mm Dia.\\"
108Supply, Installation, Testing and Commissioning of Air vessel capacity of 3 Meter³ fabricated from M.S. sheet with dished ends and suitable supporting legs, with required necessary valves and connection with required accessories. The vessel shall be design as per IS:2825, Class-II suitable for working pressure 8 kg/cm², Hydro test at 21Kg/cm², Joint efficiency 0.85, Radiography longitudinal seam 100%, Circumferential seam 10% spot.
109\\"II) HYDRANT, HOSE REEL & SPRINKLER SYSTEM Supply, Installation, Testing and Commissioning S.S. Fire Hydrant Single Landing Valve with 80 mm N.B. flanged inlet, SS spindle controlled 63 mm dia female instantaneous outlet type. SS coupling, blank cap, chain, twist release type lug & all accessories Conforming to IS:5290. Including fixing with anchor fastener and flanged tapping from wet riser complete as required.\\" Bidder should also included Water Jet Monitors 2nos
110Supply, Installation, Testing and Commissioning of Fire Hose Cabinet (900 mm x 600 mm x 250 mm deep) made of 18 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enameled Fire red finish with \\" Fire Hose\\" marked on front, suitable for housing 2 nos. Hose pipe, 1 No. branch pipe and nozzle spanner.
111Supply & Installation of Fire Hose Pipe type-B (as per IS : 636) of 63 mm dia, 1 X 15 m length. The hose shall be rated for burst pressure of 38 Kg/sqcm. Hose shall be complete with ISI marked SS male & female coupling (IS:903) with SS wire binding.
112SuperJet Water Monitor \\" Size 63 MM dia Capacity 1750, Minimum Range 53mtr.They offer 360° horizontal rotation and vertical elevations from +90° to -45°. Typically constructed using carbon steel (hot-dip galvanized), stainless steel, or gunmetal/bronze for high corrosion resistance in industrial and marine environments, Equipped with straight stream tips or variable pattern jet nozzles made of hard-anodized aluminum or bronze.Tested at pressures up to 21 to 25 kg/cm' to ensure structural integrity.
113Supply & Installation of 63 mm dia instantaneous pattern Branch Short S.S 304. pipe, 16 mm dia. nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required.
114Supply, Installation, Testing and Commissioning of First Aid Hose Reel equipment conforming to IS:884 comprising of hose reel drum, swinging type fixing bracket, 5 mm shut off nozzle and Rubber hose of 20 mm bore x 30 mtr. long etc. as per specification complete as required.
115\\"Supply, Installation, Testing and Commissioning of S.S.304 Ball Valves with all fittings required. a) 25mm dia\\"
116Supply, Installation, Testing and Commissioning of Gun Metal Four Way Fire Brigade Inlet as per IS: 904 having 63 mm dia inlet with blank cap and chain with necessary fittings, flanges, nut bolts etc.
117Supply, Installation, Testing and Commissioning of Gun Metal Air Release Valve 25mm dia. With all required accessories.
118Providing protection to under ground pipes and fittings by applying protective primer thereafter wrapping with Pypkote or equivalent material of 4mm thick & 150 mm width protection coating as per IS:10221 by thermo fusion process. Overlap shall be maintained at 15mm the application process shall be strictly according to manufacturer's specification.
119Excavation of soft soil including backfilling & compacting.
120\\"III) FIRE EXTINGUISHER AND SIGNAGES Supply, Installation, Testing and Commissioning of Carbon Dioxide (Co2) type Fire Extinguisher of 4.5 kg confirm to IS:15683, with ISI marked / TAC approved fitted with required accessories including wall suspension brackets.\\"
121Supply, Installation, Testing and Commissioning of Dry Chemical Powder (DCP) type 6 kg confirm to IS:15683, with ISI marked / TAC approved fitted with required accessories including wall suspension brackets.
122\\"Supply & Installation AUTO GLOW Signage's in Block / Small Letters of Specified Sizes: a) Fire Equipment: 4\\"\\" X 12\\"\\"\\"
123\\"Supply & Installation AUTO GLOW Signage's in Block / Small Letters of Specified Sizes: a) Fire exit : 4\\"\\" X 12\\"\\"\\" Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57759315
AUTHORITY Cooperative
TENDER VALUE 2 Crore
LAST DATE 21-10-2026
Authority
Authority Name Jaipur Zila Dugdh Utpadak Sahakari Sangh Limited
Work Description Tender for Civil Work Of Tmr Plant At Cfp Kaladera Tph) At Cattle Feed Plant, Kaladera
Basic Detail
Tender No JZDUSSL/KALADERA/2026/17917-20 (2)
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 28 Sep 2026
Submission Date 21 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 2 Crore
Tender Fee 1180
EMD 4 Lakhs
Exemption Not Available
Document List
4e57cdc7-f9aa-4cdd-bc4a-8bd7a17c5ee7.html
BOQ_1065891.xls
Tendernotice_1 (79).pdf
TMRCFPKALADERACIVILWORK.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

4e57cdc7-f9aa-4cdd-bc4a-8bd7a17c5ee7.html

xls

BOQ_1065891.xls

pdf

Tendernotice_1 (79).pdf

pdf

TMRCFPKALADERACIVILWORK.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders