Tender For General-Hydrographic Survey Wing-Electrification And Solar Panel Of The Office Of The Assistant Marine Surveyor Hydrographic Survey Wing Thannermukkam Alapuzha District -General Electrical Work
Tender Value
17.20 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
0 days left
EMD
43008
Bank guarantee accepted
Document Fee
2760
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Alappuzha → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for General-Hydrographic Survey Wing-Electrification And Solar Panel Of The Office Of The Assistant Marine Surveyor Hydrographic Survey Wing Thannermukkam Alapuzha District -General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Electrification Work - Assistant Marine Surveyor Office building and Satellite Reference Station for HSW |
| 2 | 1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A |
| 3 | 1.10.2:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B |
| 4 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 5 | 1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 6 | 1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 7 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 8 | 1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm |
| 9 | 1.18.2:Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 10 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 11 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 12 | 1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm |
| 13 | 1.22.8:Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.200 mm X 150 mm X 75 mm deep |
| 14 | 1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 15 | 1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 16 | 1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 17 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 18 | 1.24.6:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 19 | 1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 20 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 21 | 1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 22 | 1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm) |
| 23 | 1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 24 | 1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 25 | 1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 26 | 1.42:Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc., including supplying and fixing ball and socket arrangement, 2 no. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 27 | 1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 28 | 1.43:Providing and fixing extra conduit down rod of 20 mm dia, 2X10 cm length wiring with 2 X1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 29 | 1.48:Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 30 | 1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 31 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 32 | 2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)12 way, Double door |
| 33 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 34 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 35 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 36 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 37 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 38 | 2.18:Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 39 | 2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 40 | 5.3:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. |
| 41 | 5.13:Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. |
| 42 | 5.14:Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 43 | 5.17:Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 44 | 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) |
| 45 | 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. |
| 46 | 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels |
| 47 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture |
| 48 | 90.6.5.9:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 0.75 sq mm |
| 49 | 90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 50 | 90.4.1:Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 51 | 90.11.1.12:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43) |
| 52 | 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 53 | 90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface |
| 54 | 90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface |
| 55 | 90.14.7:Supply and providing copper earth bus in the panel board |
| 56 | 90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. |
| 57 | 90.15.4.1:Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 58 | 90.3.18.3:Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.40 mm dia with clamps made from 20 x 3 mm MS flat |
| 59 | 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp |
| 60 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 61 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 62 | OD8753/2025-2026:Supplying and fixing Cat 6 RJ 45 Frame on the existing modular plate & switchbox including connections but excluding modular plate etc. as required. |
| 63 | OD8747/2025-2026:Supplying and fixing Cat 6 RJ 45 computer socket on the existing modular plate &switch box including connections but excluding modular plate etc. asrequired. |
| 64 | OD1347/2026-2027:Supplying of surface-mounted linear LED luminaire fixture complete with extruded aluminum housing in powder-coated white finish, high-transmittance opal diffuser, and integral electronic non-dimmable driver (PSU) operating on 230V, 50Hz single-phase AC supply conforming to IS 10322 / IEC 60598 standards, featuring system power consumption of 30W–32W, minimum system luminous efficacy of 90 lm/W, minimum total luminous output of 2900 lumens, Correlated Color Temperature (CCT) of 4000K (Neutral White), CRI 80, Power Factor 0.90, THD < 20%, IP20 protection rating and testing complete as required. |
| 65 | OD8754/2025-2026:Supplying, installation, testing, and commissioning of light-weight, rust-proof axial ventilation / exhaust fan of nominal sweep size 150 mm (6 inches) complete with high-efficiency plastic aerodynamic blades for enhanced air delivery and speed, corrosion-free plastic body, low-noise single-phase AC motor operating on 230V, 50Hz supply, complete with front louvers/shutter, necessary mounting frame/fasteners, internal electrical interconnections, earth terminal connectivity, alignment, and testing complete as required. |
| 66 | OD1390/2026-2027:Supplying, fixing, testing, and commissioning of outdoor weatherproof, UV-stabilized fiberglass reinforced polyester (GRP/FRP) hinged control cubicle enclosure of nominal external dimensions 600 x400x 230mm providing minimum IP66 protection level and IK10 impact resistance, complete with double-bar lockable insulated door, internal galvanised steel mounting base plate, cable entry knockouts/glands, and wall/structure mounting accessories, complete with supply and fixing inside the enclosure of 63A, 16kA, 4-Pole MCCB (conforming to IS/IEC 60947-2) along with rotary handle kit (BUC), including providing necessary factory/site punched entry and exit holes, sealing arrangement provisions, internal interconnections using suitably rated FRLS copper conductor cables/wires with matching tinned copper lugs/sockets, frame earthing terminals, hardware, and fixing in position complete as required. |
| 67 | OD8761/2025-2026:Supplying, fixing, testing, and commissioning of outdoor weatherproof, UV-stabilized fiberglass reinforced polyester (GRP/FRP) hinged meter box enclosure of nominal external dimensions 600 X 400 X230mm, providing minimum IP66 protection level and IK10 impact resistance, complete with double-bar lockable insulated door, internal galvanised steel mounting base plate, cable entry knockouts/glands, wall/structure mounting accessories, complete with internal wiring interconnections, frame grounding, and fixing in position complete as KSEB meter box with provision for fixing 3hase KSEB meter, cut out & Neutral link, with sufficient holes for fixing KSEB electronic energy meter, cut-outs and neutral link.Supply and provide 3 No of 32A HRC fuse units with 20A HRC fuse link, and 1No 32A 2way neutral link in the meter portion. Necessary holes are to be provided in the box for the entry and exit of the wire. The interconnection should be done using 4.0 sq.mm copper wire. Complete as required. |
| 68 | OD1391/2026-2027:Supplying, fixing, testing, and commissioning of wall-mounted, cubicle-type, dust- and vermin-proof polycarbonate bus bar chamber enclosure of nominal dimensions 300 x 600 x170mm providing minimum IP66 ingress protection rating, complete with transparent cover, internal mounting plate arrangement, factory/site cut entry/exit holes with suitable grommets/glands for bus bar arrangements and incoming/outgoing cable routing, weather-tight sealing using approved non-hardening binding sealant, frame earthing terminals, rawl plugs/expansion fasteners, GI/brass hardware, and fixing in position complete as required. |
| 69 | OD1394/2026-2027:Supplying, fixing, testing, and commissioning of wall-mounted, cubicle-type, dust- and vermin-proof polycarbonate bus bar chamber enclosure of nominal dimensions 300 x 300 x170mm providing minimum IP66 ingress protection rating, complete with transparent cover, internal mounting plate arrangement, factory/site cut entry/exit holes with suitable grommets/glands for bus bar arrangements and incoming/outgoing cable routing, weather-tight sealing using approved non-hardening binding sealant, frame earthing terminals, rawl plugs/expansion fasteners, GI/brass hardware, and fixing in position complete as required. |
| 70 | OD1351/2026-2027:Supplying and fixing of modular base plate along with matching front cover plate suitable for 1 or 2 modules on existing Cable Management System (CMS) / PVC trunking of size 105 mmx50mm, fabricated from flame-retardant, high-impact resistant, UV-stabilized polycarbonate material conforming to IS 14772 / IS 3854 standards, complete with dedicated mounting adaptors/clips for rigid snap-fit attachment onto the CMS trunking body, frame earthing connection terminal, necessary fixing hardware, alignment, and finishing complete as required. |
| 71 | OD1352/2026-2027:Supplying and fixing of modular base plate along with matching front cover plate suitable for 3 modules on existing Cable Management System (CMS) / PVC trunking of size 105 mmx50mm, fabricated from flame-retardant, high-impact resistant, UV-stabilized polycarbonate material conforming to IS 14772 / IS 3854 standards, complete with dedicated mounting adaptors/clips for rigid snap-fit attachment onto the CMS trunking body, frame earthing connection terminal, necessary fixing hardware, alignment, and finishing complete as required. |
| 72 | OD1353/2026-2027:Supplying and fixing of modular base plate along with matching front cover plate suitable for 6 modules on existing Cable Management System (CMS) / PVC trunking of size 105 mmx50mm, fabricated from flame-retardant, high-impact resistant, UV-stabilized polycarbonate material conforming to IS 14772 / IS 3854 standards, complete with dedicated mounting adaptors/clips for rigid snap-fit attachment onto the CMS trunking body, frame earthing connection terminal, necessary fixing hardware, alignment, and finishing complete as required. |
| 73 | OD1354/2026-2027:Supplying factory-made RJ-45 to RJ-45 Category 6 (Cat-6) UTP flexible patch cord of length 2.0 metres, assembled with strain-relief molded boots and high-performance 8P8C gold-plated contact RJ-45 modular plugs at both ends, conforming to TIA/EIA-568-C.2, ISO/IEC 11801, and IS 14772 specifications for Gigabit Ethernet data communication up to 250 MHz, suitable for connecting RJ-45 data information outlets / sockets to Personal Computers / network terminal devices, including testing for continuity, pinout configuration, and signal integrity complete as required. |
| 74 | OD8755/2025-2026:upplying factory-made RJ-45 to RJ-45 Category 6 (Cat-6) UTP flexible patch cord of length 1.0 metres, assembled with strain-relief molded boots and high-performance 8P8C gold-plated contact RJ-45 modular plugs at both ends, conforming to TIA/EIA-568-C.2, ISO/IEC 11801, and IS 14772 specifications for Gigabit Ethernet data communication up to 250 MHz, suitable for connecting RJ-45 data information outlets / sockets to Personal Computers / network terminal devices, including testing for continuity, pinout configuration, and signal integrity complete as required |
| 75 | OD8759/2025-2026:Supply and providing 25x6 mm brass bolt and nut with washers on the existingMS box / earth bus etc. as required including drilling necessary holes as required |
| 76 | OD8751/2025-2026:Supplying, fixing, testing, and commissioning of Class-A retrofittable energy-efficient 9W LED bulb lamp with integrated electronic driver operating on 230V, 50Hz single-phase AC supply, conforming to IS 16102 (Part 1 & 2) / IS 10322 standards, featuring a B22 bayonet pin base, high-transmittance polycarbonate opal diffuser housing, minimum system efficacy of 90 lm/W, minimum luminous output of 810 lmfor 9W, Correlated Color Temperature (CCT) of 6500K, CRI > 80, Power Factor > 0.90, THD < 20%, and surge protection, fixing in existing lamp holder, including , testing, and commissioning complete as required. |
| 77 | OD8758/2025-2026:Supplying, installation, testing, and commissioning of wall-mounted, weatherproof, dust- and vermin-proof telephone junction box of nominal dimensions 200x160x98 mm providing minimum IP65 protection rating, complete with high-grade polycarbonate housing, internal galvanized iron (GI) mounting frame/rail arrangement, factory/site cut cable entry knockouts/glands, and housing with 10-pair IDC (Insulation Displacement Connection) KRONE-type telephone wire disconnection module suitable for terminating up to 0.50 mm diameter solid copper conductor telephone wires, including wire identification, systematic pair routing, termination onto the KRONE block adhering to standard color codes using specialized crimping/insertion tools, non-hardening sealing arrangements, frame earthing terminals, rawl plugs/expansion fasteners, GI/brass hardware, and fixing in position complete as required. |
| 78 | OD1348/2026-2027:Supplying, installation, testing, and commissioning of wall-mountable Electronic Private Automatic Branch Exchange (EPABX) system of configuration 1 Trunk (CO) line and 6 Internal Extension lines , operating on 180V to 250V,AC, 50Hz single-phase power supply with maximum power consumption of 20W, complete with built-in features including FSK/DTMF Dual Caller ID, flexible extension numbering, power failure loop-through connection, auto call back, barge-in, multi-party conferencing, broker's call, and programmable day/night service modes, including fixing the main processing unit on wall/structure using expansion fasteners, mounting, line identification, systematic cable routing, termination of incoming trunk and outgoing extension telephone wires onto the system main distribution block as per standard telecom color code using specialized crimping/insertion tools, system programming, extension testing, frame earthing, and commissioning complete as per the instructions of the Engineer-in-Charge at site complete as required. |
| 79 | OD1349/2026-2027:Supplying, installation, testing, and commissioning of 2 kVA 1-Phase In1-Phase Out True Online Double-Conversion Microprocessor/IGBT-based Uninterruptible Power Supply (UPS) system operating at 96V DC}$ bus voltage, equipped with built-in galvanic isolation transformer, IGBT-based charger and inverter producing pure sine wave output, conforming to ISO 9001:2008, ISO 14001:2004, CE, RoHS, PeP certifications, and IEC/EN 62040-1, 62040-2, and 62040-3 standards; complete with external battery bank comprising 8 Nos. 12V, 75 AH tall tubular C10 batteries providing 3 hours backup time at full load, heavy-duty floor/wall-mounted steel battery rack, interconnecting copper cables with insulated lugs, inter-battery connectors, AC input/output terminals, frame earthing connectivity, alignment, testing, commissioning, and minimum 5-year comprehensive warranty covering both UPS system and battery bank complete after installation at site as required |
| 80 | OD1342/2026-2027:Supplying and fixing of 80mmx 50mm rigid, unplasticized polyvinyl chloride (uPVC) Cable Management System (CMS) / cable trunking complete with mounting base channel and snap-on top cover lid, fabricated from high-impact, flame-retardant, self-extinguishing, and UV-stabilized uPVC material conforming to IS 14772 / IS 9537 / IEC 61084 standards, fixed on surface or chased into wall/ceiling recess as per site requirements using metallic expansion anchors/rawl plugs, brass/GI screws, and washers, complete with supply and installation of factory-made matching accessories including flat/internal/external angles, equal/unequal tees, end caps, joint couplers, and internal cable retaining clips, frame earthing continuity connectivity, chasing repair/finishing complete as required. |
| 81 | OD1343/2026-2027:Supplying and fixing of 105mmx 50mm rigid, unplasticized polyvinyl chloride (uPVC) Cable Management System (CMS) / cable trunking complete with mounting base channel and snap-on top cover lid, fabricated from high-impact, flame-retardant, self-extinguishing, and UV-stabilized uPVC material conforming to IS 14772 / IS 9537 / IEC 61084 standards, fixed on surface or chased into wall/ceiling recess as per site requirements using metallic expansion anchors/rawl plugs, brass/GI screws, and washers, complete with supply and installation of factory-made matching accessories including flat/internal/external angles, equal/unequal tees, end caps, joint couplers, and internal cable retaining clips, frame earthing continuity connectivity, chasing repair/finishing complete as required. |
| 82 | OD1375/2026-2027:Supplying, installation, testing, and configuration of 12-Port Gigabit L2+ Managed PoE+ Network Switch complete with 8 Nos. 10/100/1000 Mbps RJ-45 PoE+ ports (IEEE 802.3af/at compliant with total PoE power budget ge 120W, 2 Nos. 10/100/1000 Mbps RJ-45 Gigabit Uplink ports, and 2 Nos. 1000Base-X Gigabit SFP optical slots, featuring hardware switching capacity ge 24 Gbps and packet forwarding rate ge 17.85 Mpps, supporting Advanced L2+ network management capabilities including IP-MAC-Port Binding, Access Control Lists (ACL), Port Security, DHCP Snooping, 802.1X Authentication, RADIUS, L2/L3/L4 QoS, IGMP Snooping, Web GUI, CLI, SSH, and Dual Image system redundancy, along with manufacturer OEM 3-Year Warranty Certification; complete with supply and integration of 1 No. 1.25G Single-Mode SFP Optical Transceiver Module with LC duplex connector supporting up to 10 km optical link distance at 1310 nm wavelength for fiber uplink connectivity, complete with rack/wall mounting brackets, power cord, patch cable interconnections, configuration, port testing, earthing, and commissioning as required. |
| 83 | OD1385/2026-2027:Supplying, installation, testing, and commissioning of wall-mounting, dust- and vermin-proof 4U network/equipment rack enclosure manufactured from minimum 1.2 mm thick Cold Rolled Close Annealed (CRCA) steel frame with powder-coated finish, equipped with lockable front toughened glass door, top and bottom cable entry cutouts with rubber grommets, complete with supply and internal mounting of 1 No. 1U horizontal cable manager, 1 No. 1U horizontal Power Distribution Unit (PDU) equipped with 6 Nos. 5A Indian standard 3-pin sockets, master indicator switch, and fuse protection, 1 No. top-mounted 230V AC cooling fan unit with protective vermin-proof louvers, internal 19-inch mounting angles/profiles, required captive cage nuts and screws, and heavy-duty metallic expansion anchor bolts; scope includes wall fixing, cable dressing, internal wiring, frame protective earthing/grounding connections, and testing complete as required. |
| 84 | OD1305/2026-2027:Supplying, installation, testing, and commissioning of outdoor energy-efficient LED bulkhead luminaire fixture of nominal system wattage 10W, complete with pressure die-cast aluminum housing, high-impact polycarbonate optical lens/diffuser, integral electronic non-dimmable driver (PSU) operating on 230V, 50Hz single-phase AC supply, providing IP66 ingress protection rating, minimum total luminous flux of 1100 lumens, minimum system efficacy of 110 lm/W, Correlated Color Temperature (CCT) of 6500K (Cool Daylight), CRI > 80, Power Factor > 0.90, THD < 20%, and internal surge protection, including fixing directly on wall or ceiling using rawl plugs, expansion fasteners, and brass/GI screws, complete with internal electrical connections using FRLS copper conductors, frame earthing loop connections, alignment, and testing complete as required. |
| 85 | OD8756/2025-2026:upplying, laying, binding, and fixing of 12 SWG (2.64mm diameter) tough-rubber insulated Galvanized Iron (GI) wire used as stay wire / bearer wire for overhead service line binding and support, complete with necessary GI binding clips, strain insulators, strain clamps, wall/pole fixing hooks, mechanical tensioning, firm binding along the entire span of the service main cable, and frame/earth-electrode connection at both ends, including all required fixing accessories, hardware, and labor complete as required. |
| 86 | OD2750/2026-2027:Supplying, installation, testing, and commissioning of On-Grid Solar Photovoltaic (SPV) Power Plant conforming to MNRE specifications and guidelines (as amended), complete with high-efficiency Mono/Poly-Crystalline Silicon SPV modules of unit capacity 330Wp or above (manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730 Part 1 & Part 2, ALMM listed) having minimum module conversion efficiency of 16.5% and performance warranty of minimum 90% peak output at 10 years and 80% at 25 years, mounted on hot-dip galvanized iron (GI) / anodized aluminum structural framework designed for wind speed withstand capacity up to 150km/h; 3-Phase Grid-Tied Power Conditioning Unit (PCU) / String Inverter operating at 350V–800V DC input and 400V AC, 3-phase, 4-wire,50Hz +- 2.5Hz output, with peak efficiency >97$, THD < 3%, operating ambient temperature range 0 C to 50C, auto grid-synchronization, and islanding protection; Data Monitoring System with RS485/Ethernet/Wi-Fi communication telemetry; Array Junction Boxes (AJB) and Main Junction Boxes (MJB) with IP65 ingress protection, disconnect switches, and terminal blocks; Lightning Arresters (Class I/II) and Surge Protection Devices (SPD); interconnections using 1.1kV grade XLPE insulated UV-resistant copper conductor armoured DC/AC power cables, control cables, cable trays, conduit, brass glands, tinned copper lugs, dual earthing for modules, inverter, and structure, bi-directional net metering interface provisions, testing, grid synchronization, and commissioning complete as instructed by Engineer in charge at site. |
| 87 | OD6001/2026-2027:Supplying and fixing outdoor weather-proof type UV-stabilized thermoplastic / polycarbonate Cable Junction Box of protection class IP65, nominal dimensions 80 mm × 80 mm × 52 mm, suitable for cables up to 2.5 sq.mm, complete with 1 No. 5-pole 2.5 sq.mm copper terminal set, including mounting and fixing directly on wall or steel structural framework using suitable size Stainless Steel (Grade 304) bolts, nuts, washers, expansion fasteners, or rawl plugs, providing cable entry holes with weatherproof grommets/glands, connecting up to 2.5 sq.mm copper conductor cables, earthing continuity, alignment, and making good all damages complete as required |
| 88 | OD6002/2026-2027:Supply and fixing of Panel mounting type LED Indication lamp R ,Y, B with Multi-chip technology for uniform brightness made of Polycarbonate material ,with a diameter of 22.5mm cut out ,operating voltage of 230V AC 50Hz ,IP65, Screw-type terminals for secure wire connection ,50,000 burning hours .complete as required. |
| 89 | OD6003/2026-2027:Supplying and fixing 2A rating, c curve 240/415 volts, 10 kA, miniature circuit breaker suitable for protection of meter control and auxiliary circuit having following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 90 | OD6004/2026-2027:Painting letters or figure of following sizes with enamel paint as identification mark to SB,DB, panel board etc as required. 2.50 cm, 4 cm or 5cm height. |
| 91 | OD6005/2026-2027:Supply and providing 2.5 mm thick,1m x 2m Synthetic polymer/PVC blend electrical grade Checkered type rubber mat suitable for Medium Voltage installations have IS 15652:2006 Standard ,Class B,Dielectric Strength of 45 kV AC for 1 minute,Self-extinguishing,Anti-skid checkered or dotted top surface and plain at bottom at site complete as required. |
| 92 | OD6006/2026-2027:Supply and providing 4Kg, IS 15683 mark ,stored pressure ABC Powder type Fire Extinguisher with hose and clamps including all fixing accessories and fixing it to wall as directed by Department officials complete as required. |
| 93 | OD6008/2026-2027:Supply, installation, testing, and commissioning of electronic push-button telephone instrument with tone/pulse switchable dialing, redial, flash, mute features, and line cord, wall/desk mountable type, complete with necessary connections and testing as required. |
| 94 | OD6009/2026-2027:Identification, tracing, and bunching of existing 4 pair CAT-6 / multi-pair telephone cable, including cutting, stripping, punching/terminating at both ends with RJ-45 / RJ-11 modular connectors or inside existing modular information outlets/sockets using specialized crimping and punching tools, with numbering, identification ferruling, continuity testing, and making the connections complete as required. |
| 95 | OD6011/2026-2027:Supplying, installation, testing, and commissioning of square surface mounted LED luminaire of nominal size 312 mm × 312 mm, having deep drawn / fabricated CRCA sheet steel housing with epoxy polyester powder coated white finish, high-transmittance optical diffuser, with correlated colour temperature (CCT) of 6500K, colour rendering index (CRI) not less than 80, equipped with integral/built-in high-efficiency electronic LED driver suitable for 230V, 50Hz single-phase AC supply, power factor greater than 0.9, total harmonic distortion (THD) less than 10%, compliant with relevant IEC standards for safety, performance, and electromagnetic interference (EMI/EMC), complete with all necessary mounting brackets, hardware, interconnections, earthing, and testing as required. |
| 96 | OD1306/2026-2027:Execution of end-to-end documentation work, file preparation, scheme/single-line drawing preparation, and liaison services for obtaining a new Low Tension (LT) electricity connection from Kerala State Electricity Board (KSEB) Limited, including compiling ownership/occupancy documents, preparing physical/cad schematic wiring diagram and site location sketch indicating connected load and earthing details, filling prescribed LT service connection application form, online registration on KSEB Web Self Service (WSS) portal, payment of statutory application/registration fees on behalf of the consumer, coordination with KSEB Electrical Section Office / Assistant Engineer for field site inspection, defect rectification assistance, obtaining test cum completion certificate from licensed electrical contractor, tracking application status, and facilitating final service connection meter installation complete as per KSEB Terms & Conditions of Supply / Kerala Electricity Supply Code guidelines and instructions of the Engineer-in-Charge complete as required. |
| 97 | CIVIL |
| 98 | 5.22.1:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelMild steel and Medium Tensile steel bars Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender