Tender For Electrical Installation Work Due To Urgent Repairing Of Civil Work At Old C Us Dr. R Ahmed Dental College And Hospital , Kolkata.

Issued by Government Departments · Kolkata, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Oct 2026
17 days left
EMD
62100
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Installation Work Due To Urgent Repairing Of Civil Work At Old C Us Dr. R Ahmed Dental College And Hospital , Kolkata.

BOQ

Name of Work:- Electrical Installation work due to urgent repairing of civil work at old c us Dr. R Ahmed Dental College and Hospital , Kolkata.
Sl. No. Item Description
1Lowering and refixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. making necessary disconnection and connection as required.
2Taken down the existing single / twin Tube Fittings from celing and Fixing the same after Civil work at same location.
3Supply & Delivery of 240V LED lamps of following wattage with glare free light distribution having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips /Wipro/ Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
49W LED Bulb B22/E27 Base
5Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cumJB on wall compl ete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/ Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx 100mm x65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish (Av run 10mt.)
6Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/ Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish
7On Board
8Supply and Delivery of 4 feet Industrial box type single LED tube batten/ mounting rail (rust free) suitable for single TLED lamp. [Make- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate]
9Supply and Delivery of 4 feet Industrial box type double LED tube batten/ mounting rail (rust free) suitable for single TLED lamp. [Mal,e- Philips/ Wipro/Lighting Technology /manufacturer with own NABL accredited lab with valid test certificate]
10Supply & Delivery of 240V, 18/ 20 W LED Tube (Polycarbonate with heat sink) with glare free light distribution with CCT (5000K-6500K) having minimum luminous efficiency of 100 Lm/ Watt or better & 50,000 LED burning hours or more. [Mal,e- Philips/ Wipro/Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
11Do-- do--- do -- do -- do in place of damaged one in existing fittings.
12Supply & Delivery of 240V recess mounted 2'x2' LED downlight having following wattage in white powder coated pressure die cast aluminium housing , with glare free uniform illumination, suitable for 2' x 2' grid ceiling with CCT (5700K-6500K) having minimum luminous efficiency of 120 Lm/ Watt or better & 50,000 LED burning hours or more. [Mal{e-Philips/Wipro /Lighting Technology/ manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification]
1324 Wat
14Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length
15Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
16Fan & Fan Clamps
17Fixing only existing cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
18Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)
19Supply & Delivery of 230V, 1-Ph, AC ceiling fan of follwing size incl. all accessories. (Make- Crompton / Usha / Orient) [BEE star rated] Sweep Size- 1200 mm (48\\"), Wattage :S 55 Watt, R.PM :S 380, Air Delivery ;:: 210 C.M.M '
20Fixing only the AC Ceiling Fan complete with blades, canopy, frubber bush etc. incl S&F Connecting wire for down rod up to 30cm incl. painting the rod with approved paint & making necess. Connection as required by 2x1.5 sqmm flexible copper wire.
21Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
22S & F 240 Volt 6Amps Piano key type switch (Anchor make) on existing sheet metal switch board having bakelite/ perspex top cover by screws after making housing for switch by cutting bakelite perspex cover and making necessary connections as required.
23S & F 240 Volt 16/20Amps Piano key type switch (Anchor make) on existing sheet metal switch board having bakelite/ perspex top cover by screws after making housing for switch by cutting bakelite perspex cover and making necessary connections as required.
24S & F 240 Volt 6Amps Plug socket (Anchor make) on existing sheet metal switch board having bakelite/ perspex top cover by screws after making housing for switch by cutting bakelite perspex cover and making necessary connections as required.
25S & F 240 Volt 20Amps Plug socket (Anchor make) on existing sheet metal switch board having bakelite/ perspex top cover by screws after making housing for switch by cutting bakelite perspex cover and making necessary connections as required.
26Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240 x200 x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required (Periodontia dept.)
27Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required (At Cash section)
28Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
292 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
302 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
312 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
322 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC
33Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required
344x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC
35Supplying and fixing 32mm PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
36Supplying & fixing of 230V, Timer DB Fixed on Wall by flat iron/Angle frame or as per direction of EIC .The Box should comprising following accessories.........A).Double-door SPN-MCB Distribution Board with IP-42/43 protection 2+8 way make Legrand/L&T or as to GS.B). 1No. 250V ,50Hz,16 Amp Digital daily & weekly time switches(Make L&T-67DDT0/Eqv. legrand)C)1No 250V,25A DP-Contactor (Make- legrand model -DX³ contactors - 25 A 2 NO contactor 412544). D)1No. 250V,25A DP-MCB(Make-L&T/Eqv. legrand). E)The complete arrangement must be wiring by suitable size of PVC insulated Cu wire with suitable socket/lugs as per requirement & direction by EIC .
37Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
382+12 way (Legrand make), Enclosure (607712)
39Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
404 Way (Legrand- make) Enclosure (607715)
41Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection
42250V, 40A DP Isolator (Legrand make)
43250V, 63A FP Isolator (Legrand make)
44Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection
45250V, 6-32A SPMCB (Legrand make)
46Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.
472.5 SQ.MM.
484 SQ.MM.
496 SQ.MM.
5010 SQ.MM.
51Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
52painting of any steel/iron surface with no. of coats of paints as given below with ready mixed paint/primer of approved make and brand incl. preparation of surface by sand paper / emery paper, cleaning etc. for receiving fresh coat of paint
531st coat of alumminium paint over one coat of RO primer
542nd coat of aluminium paint over 1st coat
55Dismantling the existing cables, SPNDB , HTPNDB, fan, fittings switch board, power plug, computer board ete. due to special repairing of civil work and shifting all the dismantling item from different location to safe custody and back to different location during the period of electrical works inside the campus after completation of civil work by 3(two) numbers unskilled labour during the time of Civil work. (From Ground/1st/2nd/3rd floor to store at Ground floor and to different floor)
56Rate should be quoted incl. of all taxes and cess.
57Defect Liability period : 1 year Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57757360
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 20-10-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrical Installation Work Due To Urgent Repairing Of Civil Work At Old C Us Dr. R Ahmed Dental College And Hospital , Kolkata.
Basic Detail
Tender No WBPWD/EE-I/CKHED/eNIT-45/26-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 28 Sep 2026
Submission Date 20 Oct 2026
Open Date 28 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 62100
Exemption Not Available
Document List
2911.pdf
81d679c7-9fb3-40fd-a412-cd1020cf466c.html
BOQ_5168142.xls
Tendernotice_1 (44).pdf
Tendernotice_2 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 20, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Oct 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 25 days

Tender Documents

Download All (ZIP) ↓
pdf

2911.pdf

html

81d679c7-9fb3-40fd-a412-cd1020cf466c.html

xls

BOQ_5168142.xls

pdf

Tendernotice_1 (44).pdf

pdf

Tendernotice_2 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders