Tender For Special Repair To Bldg No P-06 (Rice Shed) At 223 Coy Asc (Sup) Type B At Rajouri Under Age B/R Dett-Iii Of Ge 862 Ews
Tender Value
34.18 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
16 days left
EMD
68400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Bldg No P-06 (Rice Shed) At 223 Coy Asc (Sup) Type B At Rajouri Under Age B/R Dett-Iii Of Ge 862 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part-I (B/R Works)Taking down chowkhats or frame exceeding 1.50 and not exceeding 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed. |
| 2 | Demolition of cement concrete (un reinforced) in ground floor & paving not exceeding 15 cm thick below or above ground level complete all as specified and directed. |
| 3 | M&L for PCC type B-1, (25 mm thick), 1:2:4 (using 20mm graded stone aggregate) as in sub base/ levelling course, complete all as specified and directed. |
| 4 | M&L for machine cut kota stone slab flooring 18-20mm thick as in floors and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including screed bed or bedding layer of 15 mm thick in cement mortar 1:4 of any size and complete all as specified and directed. |
| 5 | M&L for Kota stone slab 18-20mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including machine cutting to make it square or rectangular, rubbing and cutting and polishing to achieve mirror finish, laid over and including 10 mm thick rendering 1:6 cm complete all as specified and directed. |
| 6 | Taking down cement plaster on brick/ stone or concrete surfaces including racking out joints hacking for key to any thickness scrubbing down with water etc complete all as specified and directed. |
| 7 | M&L for rendering 10mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in CM (1:6) as in wall complete all as specified and directed. |
| 8 | M&L for 15 mm thick rendering in cement mortar (1:4) on new fair faces of Brick wall/ stone wall/ concrete surfaces of walls, finished even & smooth without using extra cement mixed with water proofing compound complete all as specified and directed.Note: Water Proofing Compound shall be measured separately. |
| 9 | Supply only liquid water proofing compound conforming to IS, complete all as specified and directed. |
| 10 | M&L for rendering 5mm thick in cement mortar (1:3) on soffits of slabs, chajja etc finished even and fair without using extra cement complete all as specified and directed. |
| 11 | M&L for preparation of new plastered surface of wall surfaces including cornices applying two coats of distemper oil emulsion paint over a coat of primer including one coat wall care putty, complete all as specified and directed. |
| 12 | M&L for providing & laying of protective geotextile fabric 150 GSM over brick/ precast walls with proper overlaps of 75mm complete all as specified and directed. |
| 13 | M&L for preparation of old plastered surface of wall surfaces including cornices applying one coat of distemper oil emulsion paint, complete all as specified and directed. |
| 14 | M&L for preparation of new plastered surface of wall with acrylic smooth exterior paint of required shade in two or more colour (multi colour pattern as approved by GE) with two or more coats applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. |
| 15 | M&L for preparation of old plastered surface of wall with acrylic smooth exterior paint of required shade in two or more colour (Multi colour pattern as approved by GE) with one coat applied @ 1.67 ltr/10 sqm, complete all as specified and directed. |
| 16 | S&F box type steel windows/ ventilators with top hung shutters including hinges and handle with steel peg stay complete welded complete all as specified and directed. |
| 17 | Dismantling of structural steel work including welded fabric frames, doors, gates and frame truss etc complete all as specified and directed. |
| 18 | S&F steel rolling shutters 1.25mm thick without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one coat of primer, erected in position as indicated, complete gear operated type with bevel gear box and crank handle, complete all as specified and directed. |
| 19 | Taking down of rolling shutter with all connected accessories and refixing after minor repair all as specified and directed. |
| 20 | M&L for cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregate) 75 mm thick as in plinth protection laid in slope 1:12 from outer edge of the wall finished even and fair, laid in alternate bays including providing 6 mm wide joints through out the thickness of plinth protection in concrete bays and in between walling and plinth protection, joint filled mastic filling comprising of one part of heated bituminous 85/25 and 3 parts of sand (all by weight) complete all as specified and directed. |
| 21 | M&L for roof treatment (WPT) with PU Elastoseal primer to seal the pores and enhance the adhesive of the coating, supply and applying single component waterproofing liquid membrane based on pure, elastomatric, polythine resin cold applied of spray/brush applied membrane with an elongation of 650%+50 and tensile strength not less than 2 MPa. crack bridging ability not less than 2mm. No leakage upto 5 bars of water pressure. Shore Hardness >50 Shore. The minimum thickness to be applied shall be 1.5mm (overall) in two layers (each layer 750 micron) or as per manufacture instructions so as to achieve thickness not less than 1.5mm including providing & laying of protective geotextile fabric 150 GSM over than entire membrane with proper overlaps of 75mm complete all as specified and directed.Note :- (i) The treatment shall be carried out by authorised applicator approved by GE as per the manufacturer.(ii) Payment will be made after providing warranty certificate from the company. (iii) Roof treatment colour shall be in black/ grey. |
| 22 | M&L for PCC (1:2:4) type B-O (using 12.5mm graded stone aggregate) providing, roof kerbs or mud stops, levelling course, bedding rounded or chamfered on edges including demolition of existing PCC and removing outside the MoD land complete all as specified and directed. |
| 23 | M&L for 10 mm thick rendering on fair faces of stone/ concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement with water proofing complete all as specified and directed.Note :- Water proofing compound shall be measured separately. |
| 24 | Taking down of aluminium shutter with Glass, particles boards and connected accessories and refixing after minor repair complete all as specified and directed. |
| 25 | M&L for powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, complete all as specified and directed as per architectural drawings. |
| 26 | S&F 12mm pre laminated exterior grade both side laminated board complete all as specified and directed. |
| 27 | S&F 5mm thick sheet glass, ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed. |
| 28 | Excavation in over areas not exceeding 1.5m depth and getting out in hard/ dense soil, complete all as specified and directed. |
| 29 | M&L for plain cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed. |
| 30 | M&L for walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and directed. |
| 31 | Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified of random rubble walling, uncoursed or brought upto courses, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40 mm for lime or sand stone, complete all as specified and directed. |
| 32 | M&L for plain cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping, benching including weather slightly rounded or chamfered angles as directed including necessary form work and finishing the exposed surfaces complete all as specified and directed. |
| 33 | M&L for raised pointing to random or polygonal rubble stone masonry, uncoursed or brought upto courses in cement mortar 1:4, complete all as specified and directed. |
| 34 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m deep and getting out in hard/ dense soil complete all as specified and directed. |
| 35 | M&L for cement concrete in surface channels and drains and bedding type B-1 1:2:4 (using 20 mm graded stone aggregate) including formwork, complete all as specified and directed. |
| 36 | Extra for forming fair finished channel or drain 30cm girth (inner girth) in cement concrete using extra cement including forms, moulds, stopped end, etc complete all as specified and directed. |
| 37 | M&L for pre-cast cement concrete block masonary with solid blocks, exceeding 10 cm in width and setting in CM 1:6 type B-1 1:2:4 (using 20 mm graded stone aggregate), complete all as specified and directed. |
| 38 | Returning, filling in soil including spreading, leveling, watering & well ramming in layers not exceeding 25 cm thick complete all as specified and directed. |
| 39 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 40 | Schedule 'A' Part-II (E/M Works)Taking down carefully copper/ aluminum point wiring (light, fan, socket or power) complete, including all fittings such as switches, ceiling roses, pendants, regulators sockets etc) removing material from the site and making good the disturbed surfaces of walls, floor or ceiling etc. to match with existing specifications complete all as specified and directed. |
| 41 | M&L for Point wiring with two single core 1.5 Sqmm (nominal cross section area FRLS PVC insulated unsheathed copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including medium grade rigid non metallic PVC concealed conduit in wall after cutting chases in wall including cast iron or pressed steel terminal box covered with and including 3mm thick bakelite sheet top cover fixed flush with wall using brass screws, washers and all requisite accessories such as PVC elbow, Tee, collars, bends etc. for mounting switches, sockets, fan regulators etc for one light/ fan/ exhaust fan point controlled by one way switch 6 Amp, complete all as specified Note:- The colour coding of wiring to be followed as Red/ Yellow/ Blue Phase/ Neutral/ Earth respectively. |
| 42 | All as per item No 41.00 here-in-before but socket out 5 Amps on same board. |
| 43 | All as per item No 41.00 here-in-before but one 3 pin 15 Amp socket outlet independent with 2.5 sqmm PVC insulated FRLS multistranded copper cable with 2.5 sqmm single core multistranded FRLS copper cable as earthing lead. |
| 44 | S&F switch piano flush type single pole one way 5 amps 240 volts complete all as specified and directed. |
| 45 | S&F socket 5 amps 5 pin, 2 in 1, flush type, 230 volts complete all as specified and directed. |
| 46 | S&F switch socket combination 2 in 1, 5 pin, 15 amp flush type complete all as specified and directed. |
| 47 | S&F ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm, complete all as specified and directed. |
| 48 | M&L for LED Tube light fitting, 1x 20 watts decorative ultra slim linear LED lighting fixture with co-extruded polycarbonate body, environmental friendly, energy efficient ready to use pack complete rewired, premium 20 W LED batten, connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core, including removing old/ unserviceable complete all as specified and directed. |
| 49 | S&F exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz,300mm sweep having power input 70W speed 1400RPM including connection as required at site with flexible copper cable complete all as specified and directed. |
| 50 | M&L for sheet metal enclosure MCB distribution board, double door single pole and neutral with IP-66 protection single phase 240 volts 12 way, including suitable size copper bus bar and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete including removing old/ unserviceable DB, complete all as specified and directed. Note:- MCBs shall be measured separately. |
| 51 | M&L for MCB single pole and neutral 240 volts any rating upto 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, including removing old/ unserviceable MCB, complete all as specified and directed. |
| 52 | S&F miniature circuit breaker (MCB) SP, 5 to 32 Amp, 240V, 10KA 'B' curve in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 53 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 2 core complete all as specified and directed. |
| 54 | M&L for double wall corrugated pipe (DWC) of 40mm dia confirming to IS: 16205 Part-24 and IEC 61386 (Part-24) for cable protection of cable under/ above ground surface complete all as specified and directed. |
| 55 | M & L for earthing with galvanised steel earth plate electrode 600mm x 600mm x 6 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth not less than 1.5 mtr below ground level connected to connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 including GI pipe 15 mm dia light grade for protection to the extend of 7.5 mtr as earthing lead connecting to equipment with provn charcol and salt complete including PCC chamber with RCC cover watering arrangement with GI pipe 20 mm dia medium grade and MS funnel, including excavation and earth work and returning, filling in including ramming and removal of surplus soil and testing on completion complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender