Bids Are invited for Design, Supply, Installation, Commissioning And Maintenance Of Grid Connected Roof Top Solar Power Plant Service - On-Grid System Without Battery; As Per Gem Atc; As Per Gem Atc - Design & Engineering, Procurement, Supply, Instal
Tender Overview
Project Description
Bids Are invited for Design, Supply, Installation, Commissioning And Maintenance Of Grid Connected Roof Top Solar Power Plant Service - On-Grid System Without Battery; As Per Gem Atc; As Per Gem Atc - Design & Engineering, Procurement, Supply, Installation, Testing, And Commissioning Of Cumulative 300 Kwp Grid-Tied Solar Pv Power Plants At Various Buildings Of The Indian Maritime University, Headquarters. , Defect Liability Period And Comprehensive Maintenance Of 300 Kwp Solar Pv Power Plants At Various Buildings Of The Indian Maritime University, Headquarters. , Design & Engineering, Procurement, Supply, Installation, Testing, And Commissioning Of Cumulative 300 Kwp Grid-Tied Solar Pv Power Plants At Various Buildings Of The Indian Maritime University, Headquarters. , Supply & Delivery Of Pv Module Mounting Gi Structure For Cumulative 300 Kwp At Various Buildings Of The Indian Maritime University, Headquarters. , Supply & Delivery Of Grid Connected String Inverter Ranging From & Above 20 Kw To 100 Kw Or As Per Installed Capacity Cumulative Array Capacity:300 Kwp At Various Buildings Of The Indian Maritime University, Headquarters. , Supply & Delivery Of Following Items At Site For Cumulative 300 Kwp Spv Power Plant At Various Buildings Of The Indian Maritime University, Headquarters. As Per Technical Specifications. A) Pv Array Junction Boxes (Ajb)B) Acdbc) Dc Power Cable & Dc Control Cable (Including Laying) D) Ac Power Cable (Including Laying)E) Upvc Conduits (Including Laying)F) Kioskg) Earthing Cable , Earth Bus, Earth Electrode H) Solar Energy Net Meteri) Cleaning Arrangement Of Pv Arrayj) Project Signage K) Safety Signagel) Lightning Arrestor M) Fire Extinguishern) Fire Buckets And Holding Stand , Supply & Delivery Of Data Logger And Web Based Weather Monitoring System With Necessary Attachment With Sim/ Necessary Communication Connections For Cumulative 300 Kwp Spv Power Plant At Various Buildings Of The Indian Maritime University, Headquarters As Per Technical Specification. , Required Documents Supporting Design, Efficiency And Compliances To Ip/Is/Iec Codes As Per Ts, Required To Be Submitted In Technical Bid, Which Is Part Of Technical Evaluation.
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Design & Engineering, Procurement, Supply, Installation, Testing, and Commissioning of cumulative 300 kWp Grid-Tied Solar PV Power Plants at various buildings of the Indian Maritime University, Headquarters. | Design & Engineering, Procurement, Supply, Installation, Testing, and Commissioning of cumulative 300 kWp Grid-Tied Solar PV Power Plants at various buildings of the Indian Maritime University, Headquarters. |
| 2 | Defect Liability Period and Comprehensive Maintenance of 300 kWp Solar PV Power Plants at Various buildings of the Indian Maritime University, Headquarters. | Defect Liability Period and Comprehensive Maintenance of 300 kWp Solar PV Power Plants at Various buildings of the Indian Maritime University, Headquarters. |
| 3 | Design & Engineering, Procurement, Supply, Installation, Testing, and Commissioning of cumulative 300 kWp Grid-Tied Solar PV Power Plants at various buildings of the Indian Maritime University, Headquarters. | Design & Engineering, Procurement, Supply, Installation, Testing, and Commissioning of cumulative 300 kWp Grid-Tied Solar PV Power Plants at various buildings of the Indian Maritime University, Headquarters. |
| 4 | Supply & Delivery of PV Module mounting GI structure for cumulative 300 kWp at various buildings of the Indian Maritime University, Headquarters. | Supply & Delivery of PV Module mounting GI structure for cumulative 300 kWp at various buildings of the Indian Maritime University, Headquarters. |
| 5 | Supply & Delivery of Grid Connected String Inverter ranging from & above 20 kW to 100 kW or as per installed capacity cumulative array capacity:300 kWp at various buildings of the Indian Maritime University, Headquarters. | Supply & Delivery of Grid Connected String Inverter ranging from & above 20 kW to 100 kW or as per installed capacity cumulative array capacity:300 kWp at various buildings of the Indian Maritime University, Headquarters. |
| 6 | Supply & Delivery of following items at site for cumulative 300 kWp SPV power Plant at various buildings of the Indian Maritime University, Headquarters. as per technical specifications. a) PV Array Junction Boxes (AJB)b) ACDBc) DC Power Cable & DC Control Cable (including laying) d) AC Power Cable (including laying)e) UPVC Conduits (including laying)f) Kioskg) Earthing Cable , Earth Bus, Earth Electrode h) Solar Energy Net Meteri) Cleaning Arrangement of PV Arrayj) Project Signage k) Safety Signagel) Lightning Arrestor m) Fire extinguishern) Fire Buckets and Holding stand | Supply & Delivery of following items at site for cumulative 300 kWp SPV power Plant at various buildings of the Indian Maritime University, Headquarters. as per technical specifications. a) PV Array Junction Boxes (AJB)b) ACDBc) DC Power Cable & DC Control Cable (including laying) d) AC Power Cable (including laying)e) UPVC Conduits (including laying)f) Kioskg) Earthing Cable , Earth Bus, Earth Electrode h) Solar Energy Net Meteri) Cleaning Arrangement of PV Arrayj) Project Signage k) Safety Signagel) Lightning Arrestor m) Fire extinguishern) Fire Buckets and Holding stand |
| 7 | Supply & Delivery of data logger and Web based Weather Monitoring system with necessary attachment with SIM/ necessary communication connections for cumulative 300 kWp SPV power plant at various buildings of the Indian Maritime University, Headquarters as per Technical Specification. | Supply & Delivery of data logger and Web based Weather Monitoring system with necessary attachment with SIM/ necessary communication connections for cumulative 300 kWp SPV power plant at various buildings of the Indian Maritime University, Headquarters as per Technical Specification. |
| 8 | Required documents supporting Design, Efficiency and compliances to IP/IS/IEC codes as per TS, required to be submitted in Technical Bid, which is part of Technical Evaluation. | Required documents supporting Design, Efficiency and compliances to IP/IS/IEC codes as per TS, required to be submitted in Technical Bid, which is part of Technical Evaluation. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender