| Sl. No. | Item Description |
| 1 | M&L for taking down unsv geyser of 25 Ltr capacity from existing position by disconnecting Elect/ water connections, from any position, locations and replacing the following unsv parts complete all as specified as mentioned below: - |
| 2 | (i) S&F in repairs thermostat suitable for 25 ltr storage type Vertical water heater ISI mark as per existing one complete all as specified and as directed. |
| 3 | (ii) S&F in repairs LED indication lamp suitable for Geysers in roud/ rectangular shape complete all as specified and as directed. |
| 4 | (iii) S&F in repairs Geyser assembly suitable to fix thermostat, heating elements as of the existng size suitable for 25 ltr capacity geyser including suitable washers, clamps with bolts & nuts suitable for 06/09 hole complete all as specified and as directed. |
| 5 | (iv) S&F in repairs fusible plug suitable for 25 ltr capacity Geysers as per existing complete all as specified and as directed. |
| 6 | (v) Taking down unsv bottom/ top cover plates (2 half) and S&F with new bottom/ top cover plates with machine coloumns of Geyser 25 ltr capacity complete all as specified and as directed. |
| 7 | (vi) S&F in repairs steel water tank suitable for 25 ltr capacity water heater vertical type as per existing model and size complete all as specified and as directed. |
| 8 | (vii) S&F safety plug suitable for 25 ltr capacity vertical type water heater as per existing model/ make complete all as specified and as directed. |
| 9 | (viii) S&F in replacement of M S heavy duty fabricated frame suitable for holding water tank of 25 ltr capacity geyser, as per sample and existng shape and size including suitable hole for mounting the Geyser complete all as specified and as directed. Note: Sample can be taken for the geyser by the contractor from concerned JE E/M sub division before quoting the rate. |
| 10 | S&F in replacement heating element 2 KW triangle type suitable for 25 ltr capacity vertical type water heater ISI mark. Make: Theeta complete all as per existing. |
| 11 | (x) S&F glass wool heat insulation superior quality suitable for geyser of Capacity 25/35/50 ltr complete all as specified and as directed. |
| 12 | (xi) S&F outer cover in replacement suitable for 25 ltr capacity vertical water heater as per existing model heavy duty complete all as specified and as directed. |
| 13 | (xii) Supply only nuts, bolts, washers suitable of existing size and model suitable for fixing of Geyser assembly with geyser tank complete all as specified and as directed. |
| 14 | (xiii) S&F Stainless Steel connection mesh type for HOT/ cold water supply 2' long heavy duty ISI mark as per sample complete all as specified and as directed. |
| 15 | Supply & fix in replacement of SPN enclosure with two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified and as directed. |
| 16 | S&F submain wiring with unsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 6 Sqmm single core HR Grade and one run of 6 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 17 | S&F submain wiring with unsheathed multi-stranded FRLS Grade copper conductor cable 1100 volts grade drawn through in and including PVC rigid conduit medium grade of not less than 25mm dia with conduit accessories and concealed in wall/surface of ceiling for two runs of 4 Sqmm single core HR Grade and one run of 4 Sqmm PVC insulated copper conductor for earth continuity wire between main DB to Sub main DB complete all as specified and as directed.Note :- Two run of single core cable with one run of earth continuity conductor and PVC conduit and accessories will be measured as one length including cutting chasing in wall complete.Note 1: Rates are deemed to be included for chases of conduit and sunking for boxes cutting and making holes in wall/floor for passing in or through conduit. |
| 18 | S&F cable copper flexible 3 Core cicular type 2.5 sqmm heavy duty complete all as specified and as directed. |
| 19 | S&F cable copper flexible 3 Core cicular type 4 sqmm heavy duty complete all as specified and as directed. |
| 20 | Supply and fixing ball bearing suitable for ceiling fan,wall mounted fan, exhaust fan, pedestal fan of same size as that of existing defective one complete all as specified and as directed. |
| 21 | Supply and fixing bush bearing suitable for ceiling fan,wall mounted fan, exhaust fan and pedestal fans complete all as specified and as directed. |
| 22 | M&L for repairing of fan stator sheet as required complete all as specified and as directed. |
| 23 | S&F screws as per sample for fixing of fan blades with fan stator complete all as specified and as directed. |
| 24 | M&L for Cleaning and preparing the surfaces of ceiling fan removing the grease, carbon dust over the fans and painting with one coat of synthetic enamel paint of approved colour with brush painting and writing MES number on the fan complete all as specified and as directed. |
| 25 | M&L for Rewinding the stator complete with super enamelled bare copper conductor with the same size and number of turns as that of the old one insulating, varnishing and pre heating complete all as specified and as directed for the following :- |
| 26 | Ceiling fan 1200mm/1400mm sweep. |
| 27 | Exhaust fan 200mm / 300 mm sweep. |
| 28 | Exhaust fan above 450mm sweep. |
| 29 | Supply and fix Down Rod of any size as per requirement at site complete all as specified and as directed. |
| 30 | Supply and fix Ceiling fan cycle assembly complete all as specified and as directed. |
| 31 | M&L for Removing the damaged and corroded exhaust fan louvers and replacement with new louvers of following sizes:- |
| 32 | Exhaust fan 200mm upto 300mm sweep. |
| 33 | Exhaust fan above 300mm upto 450mm sweep. |
| 34 | M&L for Removing the damaged , corroded exhaust fan blades and replaced with new blades of size:- |
| 35 | Exhaust fan 150/200mm / 250mm sweep as per sample . |
| 36 | Exhaust fan above 300mm / 450mm sweep. |
| 37 | Material and labour for shifting & fixing of old serviceable exhaust fan and making circular opening by cutting stone wall in any size and shape complete with i PCC (1:2:4) B0 12.5mm graded aggregate and grouting 04 Nos bolts of size not less than 10mm dia and 100mm long with nut & washer and making good to distrubed surface complete all as specified and as directed. (Note:- Neccessary support in high rise building (ground floor to third floor) for working from out side shall be deemed inclusive). |
| 38 | Material and labour for Shifting & fixing ceiling fan with down rod including necessary holes, nuts and bolts, pin complete all as specified and as directed. |
| 39 | Material and labour for fixing fan down rod 15mm dia 2 ft long including necessary holes, nuts and bolts, pin in replacment of old u/s down rod as per site requirement complete all as specified and as directed. |
| 40 | Material and labour for fixing fan canopy in replacment of old broken u/s canopy as per site requirement complete all as specified and as directed. |
| 41 | S&F ceiling fan blades suitable for 1200 mm sweep ceiling fan as per sample in replacment of old broken u/s ceiling fan blade as per site requirement complete all as specified and as directed. |
| 42 | Taking down ceiling fan (C/F of any size/make), cleaning its dust properly oiling and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring complete all as specified and as directed.Note :- (i) The spares like cotter pin, nuts & bolts, rubber bush & hooks etc defective/damage deemed to be replaced and make the ceiling fans functional. The rates quoted for the same deemed to be included for the above job. |
| 43 | Taking down exhaust fan and re-connecting up including provision of cable from ceiling rose to exhaust fan after cleaning all dust complete all as specified and as directed. Note :- (i) The spares like nuts & bolts etc defective/damage deemed to be replaced and make the fans functional. The rates quoted for the same deemed to be included for the above job. |
| 44 | Supply & fix capacitor of 2.5 mfd complete all as specified and as directed. |
| 45 | Supply & fix capacitor of 3.15mfd complete all as specified and as directed. |
| 46 | Supply & fix capacitor of 4.0 mfd complete all as specified and as directed. |
| 47 | Supply & fix capacitor of 0.85/1.00 mfd complete all as specified and as directed. |
| 48 | Suply and fixing and connecting flexible copper twisted twin core of size 23/.00076 complete all as specified and as directed. |
| 49 | S & F heavy duty PVC cable 1100 volts grade , insulated aluminium multi stranded conductor, twin core wire of size 4 sqmm complete all as specified and as directed. |
| 50 | S & F heavy duty PVC cable , 1100 volts grade insulated aluminium multi stranded conductor, twin core wire of size 6 sqmm complete all as specified and as directed. |
| 51 | Supply and fixing rubber shackle complete with bolt, nut, split pin complete all as specified and as directed. |
| 52 | Material and labour for fixing plastic body exhaust fan blades for 250 mm sweep in replacment of old u/s platic body exhaust fan blade as per site requirement complete all as specified and as directed. |
| 53 | Material and labour for fixing fan motor with venitilated plastic cap suitable for plastic body exhaust fan for 250 mm sweep in replacment of old u/s motor of exhaust fan all per site requirement complete all as specified and as directed. |
| 54 | Material and labour for fixing plastic body exhaust fan blades for 200 mm sweep in replacment of old u/s platic body exhaust fan blade as per site requirement complete all as specified and as directed. |
| 55 | Material and labour for fixing fan motor with venitilated plastic cap suitable for plastic body exhaust fan for 200 mm sweep in replacment of old u/s motor of exhaust fan all per site requirement complete all as specified and as directed. |
| 56 | Supply and fix surface mounting frame less panel, square in shape, ABS housing and PC diffuser, inbuilt driver, 12 Watts complete all as specified and as directed. Item code : LD00118018 of Make : Polycab or equivalent model out of makes specified in list of makes. |
| 57 | S&F in replacement plastic frame suitable for 250 mm sweep ventilation fan as per existing make/ model complete all as specified and as directed. |
| 58 | S&F in replacement plastic frame suitable for 200 mm sweep ventilation fan as per existing make/ model complete all as specified and as directed. |
| 59 | S&F ventilation fan motor suitable for 300 mm sweep metal fans having double ball bearing, heavy duty motor suitable for existing make/model complete all as specified and as directed. |
| 60 | S&F ventilation fan motor suitable for 200/250 mm sweep PLASTIC exhaust fans having double ball bearing, heavy duty motor suitable for existing make/model complete all as specified and as directed. |
| 61 | Supply and fixing ceiling fans complete with blades and regulator compatible for BLDC fans, down rods with remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE Five star rated with brushless direct current motor ( BLDC) by Taking down old fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed. |
| 62 | S & F plug top 16 Amps, 240 volts complete all as specified and as directed. |
| 63 | Supply and fix in repair suitable for BLDC fan Ceiling Driver Card any make and module complete all as specified and as directed. |
| 64 | Taking down old unserviceable fitting and S & F wall mounted extruded aluminium housing high quality indoor batten LED tube light fitting 20 watt colour temperature 6500 K (4\\" long) lumen 2000 -3000, PF> 0.9, THD less 15% diffused connecting with three core flexible copper wire from connecto to ceiling rose/angle holder as per existing site requirement as directed by Engr-in-charge. |
| 65 | Taking down old unserviceable fitting S & F Recess mounting LED flat panel light fitting 36 watt, 2 x 2 , 600mm x 600 mm size with efficient LEDs lumen 2000 -3000, PF> 0.9, THD less 15% including taking down unserviceable fitting of any type and make all as specified and directed. |
| 66 | Supply and fixing in replacement of defected/unsvl electronic meters single 12 wire, 240 volt temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete by taking down old meter and deposit in the store all as specified and as directed. |
| 67 | Supply and fixing in replacement of three phase defected/unsvl electronic meters temper proof LCD display with polycarbonate cover 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete by taking down old meter and deposit in the store all as specified and as directed. |
| 68 | S&F copper flexible wire Single Core cicular type 1.0 sqmm heavy duty complete all as specified and directed. |
| 69 | S&F copper flexible wire Single Core cicular type 2.5 sqmm heavy duty complete all as specified and directed. |
| 70 | S&F copper flexible wire Single Core cicular type 4 sqmm heavy duty complete all as specified and directed. |
| 71 | S&F copper flexible wire Single Core cicular type 6 sqmm heavy duty complete all as specified and directed. |
| 72 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators, sockets etc. to be measured separately), removing materials to store for keeping in safe custody for re-use at site/Sch of credit and making good disturbed surface of walls, floors, etc complete all as specified and as directed. |
| 73 | M&L for Point wiring complete with FRLS PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sqmm (Norminal area) multistranded , copper conductor cable drawn through in non metallic rigid PVC conduit medium grade , minimum 20 mm dia conceled in wall , ISI Marked, and connect accessories, mounting on suface of walls / ceilings /roofs etc with shunken box anodised concealed in suface of wall , 3 mm thick laminated plastic sheet cover for mounting of switches, sockets outlets, regulators etc, fixed by suitable size of 04 Nos cadmium screwes including provision of FRLS PVC insulated unsheathed 1.5 Sqmm muiltistranded green colour copper conductor cable as earth connectivity and connecting to common earth dolly complete all as specified and as directed by Engineer-in-Charge, (The works includes cutting of chasis and making good disturbed surfaces alongwith painting to match the existing surface deemed to included in quated rate):- |
| 74 | One light point controlled by one way one switch SP 5 Amps , 240 V. |
| 75 | One ceiling fan/Exhaust point controlled by one way one switch SP 5 Amps, 240 V. |
| 76 | One switch socket outlet 3 Pin, 5 Amps, SP on independent board. |
| 77 | One switch socket outlet 3 Pin, 5 Amps, SP on same board. |
| 78 | All as per the item No 2 here in before but with 2.5 Sqmm cable for 3 pin 15 Amps socket complete all as specified and as directed by Engineer-in-Charge. |
| 79 | S&F switch piano flush type single pole one way , 5 Amps , 240V grade ISI marked , complete all as specified and as directed by Engineer-in-Charge. |
| 80 | S&F switch piano flush type single pole one way , 15 Amps , 240V grade ISI marked, complete all as specified and as directed by Engineer-in-Charge. |
| 81 | S&F socket outlet 2 in 1 ,3 pin 5 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge. |
| 82 | S&F socket outlet 2 in 1 ,3 pin 5 and15 Amps flush type ISI marked, complete all as specified and as directed by Engineer-in-Charge. |
| 83 | S&F step type elctronic fan regulator flush type, single phase 220 V , one module type, complete all as specified and as directed by Engineer-in-Charge. Make : Anchor or equivalent. |
| 84 | Taking out old U/S submain wiring of any size and removing materials to store or as sch of credit including making good of existing surfaces complete all as specified and as directed. |
| 85 | S&F Onload Changeover switchs of capacity 630Amps SS operated 415V , 50 Hz conforming IS/IEC 60947-1 & 3 complete all as specified and directed by Engineer-in-Charge. |
| 86 | S&F in replacement Onload Changeover switchs of capacity 200Amps SS operated 415V , 50 Hz conforming IS/IEC 60947-1 & 3 complete all as specified and directed by Engineer-in-Charge. |
| 87 | S&F in replacement Onload Changeover switchs of capacity 160 Amps SS operated 415V , 50 Hz conforming to IS/IEC 60947-1 & 3, complete all as specified and directed by Engineer-in-Charge. |
| 88 | S&F in replacement Onload Changeover switchs of capacity 100 Amps SS operated 415V , 50 Hz conforming to IS/IEC 60947-1 & 3, complete all as specified and directed by Engineer-in-Charge. |
| 89 | S&F in replacement sheet metal enclosure for MCB's (D.B) 4 way (SPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed. |
| 90 | S&F in replacement sheet metal enclosure for MCB's (D.B) 6 way (SPN)IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed. |
| 91 | S&F in replacement sheet metal enclosure for MCB's (D.B) 8 way (SPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed. |
| 92 | S&F in replacement sheet metal enclosure for MCB's (D.B) 12 way (SPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed. |
| 93 | S&F in replacement sheet metal enclosure for MCB's (D.B) 4 way (TPN) IK 08 provided with 200A insulated phase bus-bar ,neutral bar/s with shroud/s, earth bar/s, sticking saddles, cement spill protector, color-coded interconnecting wire set, cable ties,blanking plates and circuit identification label complete all as specified and as directed. |
| 94 | S&F in replacement of MCB SPN 06- 32 amp ‘C’ Series (In accordance with IS/IEC 60898-1) 240 V/415 V, 50 Hz, 10kA, capacity complete all as specified and as directed. |
| 95 | S&F in replacement of MCB SP 06- 32 amp ‘C’ Series (In accordance with IS/IEC 60898-1) 240 V/415 V, 50 Hz, 10kA, capacity complete all as specified and as directed. |
| 96 | M&L for earthing pit with brick work and PCC 1:3:6 including RCC pit cover of size 300x300mmx50mm thick with provision of opening handle complete including necessary watering, ramming and compact of soil near the earth pit all as specified and as directed by Engr-in-charge |
| 97 | Dismantling and taking up old existing unserviceable GI/copper earth plate with strip earthing and connected items complete all as specified and as directed by Engr in charge. |
| 98 | M& L for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.3mm thick, buried directly in ground(earthpit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead with 4mm dia by means of bolts, nuts and check nuts and washers of GI or steel all as shown in Electrical plate No 5 including earth work final with watering arrangement, wire mesh, GI pipe 50mm internal dia bore buried directly vertical and adjacent to the electrode for watering , PCC pit 1:3:6 type C1 and RCC chamber cover in 1:2:4 type B1 of size 550 x 550mm with 8 mm dia TMT bar of 100mm C/C both ways including of returning, filling in and removal of surplus soil to a distance not exc 50 m as specified and directed by Engr-in-charge including testing on completion. |
| 99 | M&L in replacement for earth continuity conductor or main earthing lead fixed to Floor/wall / roof/Air termination and connecting Machinery to test point with 25x3 mm aluminium strip including taking down existing aluminium/GI strip complete all as specified and directed by Engr-in-Charge .Note :- (i) Laying / fixing of strip from air termination to test point shall be in one run i.e. there shall be no joint in between air termination. In case joint is required, it shall be jointed with nut & bolt joint with breezing full contact of strip. ii) Strip shall be fixed on insulator at the interval not more than 900mm in such a manner at any place it shall not touch to wall/ roof / any metalic body. (Cost of insulator shall be measured and paid seprately under respective items of Sch of works as supply only) |
| 100 | S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 6 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge. Make :-Plaza/Polycab/Havells |
| 101 | S & F in repalacement service connection 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed of size 10 Sqmm, 2 core complete all as specified and directed by Engr-in-Charge. Make :-Plaza/Polycab/Havells |
| 102 | S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100volts grade, cross-sectional area 16sqmm 4core all as specified and directed |
| 103 | S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100volts grade, cross-sectional area 10sqmm 2core all as specified and directed |
| 104 | S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100volts grade, cross-sectional area 25sqmm 4core all as specified and directed |
| 105 | S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100volts grade, cross-sectional area 35Sqmm 3.5core all as specified and directed |
| 106 | S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100volts grade, cross-sectional area 50Sqmm 3.5core all as specified and directed |
| 107 | S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100volts grade, cross-sectional area 70Sqmm 3.5core all as specified and directed |
| 108 | S&F in replacement of XLPE insulated heavey duty electric cables with aluminium conductor, 1100volts grade, cross-sectional area 95Sqmm 3.5core all as specified and directed |
| 109 | M&L complete for drilling hole through machine under hard standing /road in different location as per site requirement (between 03 mtr to 40mtr maximum) for laying of pipe for protection of cable etc by means of bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified. |
| 110 | Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified. |
| 111 | Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point. |
| 112 | Returning, filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm complete all as specified and directed |
| 113 | M&L for sand cushioning in trenches/floor for protection including watering and consolidation all as specified and directed |
| 114 | Supply and Laying Bricks old size sub class 'B', of class designation 10, for the protection of cable laid flat dry across the cable complete all as specified. |
| 115 | M&L Preperation of old painted Steel surface of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of Red oxide primer all as specified and directed by Engineer -in-charge |
| 116 | Supply and fixing in replacement of new generation energy saving environemental friendly long life exclusive innovative die cast aluminium IP65 LED flood light with high power LEDs as light source of capacity 120 Watt complete all as specified and directed by Engineer-in-Charge. |
| 117 | Supply and fixing in replacement LED Street Lights 72 Watt, CCT not less than 5700k and Efficacy not less than 110lm/W with Potted Driver of pressure die-cast aluminium housing street lights have clear toughened glass diffuser and bottom opening driver compartment. It comes up with secondary optics and individual high power LEDs for better light distribution and control. K08 street light with IP66 degree of protection and Potted Driver with 5KV internal and 10KV external surge protection alongwith 40mm dia Medium Grade GI Pipe of 1mtr with bracket and stand for fixing in wall complete all as directed and specified by Engr-in-charge. |
| 118 | S& F in replacement of MCCB 63Amp, 4Pole,415V ,36KA (Conforms to IS/IEC:60947-2) MCCB with Thermal Magnetic Protection Unit , Range – 16A to 630A , Ics = 100% Icu ,Thermal Adjustable – 0.8 to 1 In, Magnetic Adjustable – 5 to 10 In starting from 50A all as specified and directed by Engr-in-charge |
| 119 | S& F in replacement of MCCB 100Amp 4Pole,415V ,36KA (Conforms to IS/IEC:60947-2) MCCB with Thermal Magnetic Protection Unit , Range – 16A to 630A , Ics = 100% Icu ,Thermal Adjustable – 0.8 to 1 In, Magnetic Adjustable – 5 to 10 In starting from 50A all as specified and directed by Engr-in-charge |
| 120 | S& F in replacement of MCCB 160Amp 4Pole,415V ,36KA (Conforms to IS/IEC:60947-2) MCCB with Thermal Magnetic Protection Unit , Range – 16A to 630A , Ics = 100% Icu ,Thermal Adjustable – 0.8 to 1 In, Magnetic Adjustable – 5 to 10 In starting from 50A all as specified and directed by Engr-in-charge |
| 121 | S& F in replacement of MCCB 250Amp 4Pole,415V ,36KA (Conforms to IS/IEC:60947-2) MCCB with Thermal Magnetic Protection Unit , Range – 16A to 630A , Ics = 100% Icu ,Thermal Adjustable – 0.8 to 1 In, Magnetic Adjustable – 5 to 10 In starting from 50A all as specified and directed by Engr-in-charge |
| 122 | Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) and removing rubbish to a distance upto 50 metres outside the periphery of the area, complete all as specified and as directed by Engr-in-Charge. |
| 123 | M&L for spraying of chemical (roundup) around pump house in the ratio 1:3 for burning of grass as an when required complete all as specified and directed by Engr-in-charge |
| 124 | M&L for PCC in foundations, filling and mass-concrete 1:3:6 type-C2 using 40 mm graded stone aggregate complete all as specified and directed |
| 125 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft & raft beams, sides & soffits of foundation & plinth beams; and similar work; verticle or to batter fair finished surfaces of concrete flat complete all as specified and directed. |
| 126 | S&F Insulation mat long-lasting, easy to install, clean an anti-skid a strong grip mat which is resistant to oils, acids, alkalis . low temperature and are flame retardant as per the provisions of IS 15652:2006.of thickness 2.5mm, Class B having 100% shock proof under leakage current 10 mA all as specified and directed by Engr-in-charge. Make :- Jyoti / Aicon / Vardhman or equivalent confirming to IS specification.Note: Test certificate from a Govt registered company should be submitted before installation. |
| 127 | S&F Insulation mat long-lasting, easy to install, clean an anti-skid a strong grip mat which is resistant to oils, acids, alkalis . low temperature and are flame retardant as per the provisions of IS 15652:2006.of thickness 2mm,mat size , Class A having 100% shock proof under leakage current 10 mA all as specified and directed by Engr-in-charge. Make :- Jyoti / Aicon / Vardhman or equivalent confirming to IS specification.Note: Test certificate from a Govt registered company should be submitted before installation. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender