Public Administrative Department Local Bodies Closing in 7 days TDR #57751229

Tender For Upgradation/Re-Development Of Electrical Installation And Fans At Various Mc(P) Schools Of Ward No. 193 And 194 Under Shahdara (South) Zone .

Issued by Local Bodies · Delhi, Delhi
Tender Value
23.72 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
7 days left
EMD
50000
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Upgradation/Re-Development Of Electrical Installation And Fans At Various Mc(P) Schools Of Ward No. 193 And 194 Under Shahdara (South) Zone .

BOQ

Name of Work:- Upgradation/Re-development of Electrical Installation and Fans at various MC(P) schools of ward no. 193 and 194 under Shahdara (South) Zone .
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. Group C
2Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required.Group-C
3Supply & Drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required. (a)3x2.5 sq.mm
4(b )3x4 sq.mm.
5© 3 x 6 sq. mm
6Supplying & Fixing following way,Single pole & Neutral,sheet steel,MCB Distribution board,240 V on surface/recess,complete with tinned copper bus bar,neutral bar,earth bar,din bar,interconnections,powder painted i/c earthing etc.as reqd.(But without MCB/RCCB/Isolator). (A)8 way , Double door
7(B) 12 Way, Double Door
8Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed in case of recessed conduit as required. (a) 25 mm
9Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. As required. (a) 5/6 amps switch
10(b)15/16 A switch
11(c) 3 pin 5/6 A socket outlet
12(d)6 pin 15/16 A socket outlet
13Supplying and fixing metal box metal box of 180mmx100mmx60mm deep nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLS including providing and fixing 6 pin &15/16 A socket outlet and 15/16 A piano tyep switch, connection painting etc as required
14Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10KA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a)Single pole
15Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp
16Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amp
17Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
18Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
19Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
20Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep
21Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.200 mm X 250 mm X 60 mm deep ( 8 Inch X 10 Inch )
22Dismantaling of ceiling fan & painting the same with one or more coat of spray paintaing with synthetic enamel paint of approved brand and manufacture to give an even shade including cleaning of surface with detergent and replacing the damamged rubber reel, nuts & bolts with washers and safety pins, reininsatlling the same as required.
23Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
24LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KVwith Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 18-22 watt
25LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) 150 WATT
26LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy >135 lm/Watt) Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) 70 watt
27P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
28Supply of XLPE insulated and PVC Sheathed Al conductor armoured cable 1.1 KV grade conforming to IS-7098 (P-I) as required.2C*6 Sqmm
29Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.upto 35 sq mm
30Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size wall surface as reqd. Upto35 sq. mm (clamped with 1mm thick saddle)
31Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.(a)Upto 35 sq. mm
32S & L of following size DWC HDPE pipe ISI marked along with all accessoried like socket ,bend,couplers etc. Confirming to Is 14930, Part II complete with fittings and cutting jointing etc. Diret in ground (75 Cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covring etc. complete as reqd. (a) 63 mm dia (OD-63mm & ID-51 mm nominal.)
33Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies,shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion)less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cableand earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
34Supply of XLPE insulated and PVC Sheathed Al conductor armoured cable 1.1 KV grade conforming to IS-7098 (P-I) as required.3.5C*35 Sqmm
35SITC of metal clad, powder coated, compartmentalized cubical panel board as per CPWD electrical specifications including insulated aluminum bus bars, supports, interconnection, erection of switchgears with depth 30 cm to 60 cm and making provisions for termination of incoming/ outgoing cables/ bus ducting and making foundation etc as required. (Suitable for 400 Amp TP & N)
36Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB
37Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.125 A,36KA,FPMCCB
38SITC of single phase mono block pump set complete with all accessories workable on 240/415 volt, 50 hz ac supply (a 1 hp(.75 KW single phase pump set, head from 12-30, metre suction and delivery 25x25mm
39Rewinding of AC ceiling fan of all sizes and make including oiling, greasing as required New Model (Light Weight).
40Replacement of ball bearing of size 117/120 NBC equivalent SKF make as required.
41Replacement of fan condenser 2.5 mF as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57751229
AUTHORITY Local Bodies
TENDER VALUE 23.72 Lakhs
LAST DATE 06-10-2026
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender for Upgradation/Re-Development Of Electrical Installation And Fans At Various Mc(P) Schools Of Ward No. 193 And 194 Under Shahdara (South) Zone .
Basic Detail
Tender No EEE-I/2026-27/9.1
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 28 Sep 2026
Submission Date 06 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 23.72 Lakhs
Tender Fee 590
EMD 50000
Exemption Not Available
Document List
BOQ_341073.xls
condition1_2.pdf
d7024e77-ae3e-4db6-a5b6-bd900cd40a02.html
Tendernotice_1.pdf
viewsbd.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_341073.xls

pdf

condition1_2.pdf

html

d7024e77-ae3e-4db6-a5b6-bd900cd40a02.html

pdf

Tendernotice_1.pdf

pdf

viewsbd.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders