Tender For (Rmo All E & M Services Installed At Chb, At Kasturba Niketan Lajpat Nagar New Delhi.
Tender Value
10.10 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
7 days left
EMD
20211
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for (Rmo All E & M Services Installed At Chb, At Kasturba Niketan Lajpat Nagar New Delhi.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mmFRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | a) Group C |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. |
| 4 | a) Group C |
| 5 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. |
| 6 | 20 mm |
| 7 | 25 mm |
| 8 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 9 | 3 x 1.5 sq. mm |
| 10 | 3 x 4 sq. mm |
| 11 | 3 x 6 sq. mm |
| 12 | Supplying of following items to be used during day to day maintenance |
| 13 | 18watt LED Downlilghter light fitting |
| 14 | 36 watt 2x2 LED light fitting |
| 15 | 18-22watt LED batten |
| 16 | 36watt LED batten |
| 17 | 70watt LED flood light fitting |
| 18 | 1200mm sweep BLDC ceiling fan, BEE 5 Star rating |
| 19 | 2.5MFD capacitor |
| 20 | S.P. 5/6 amps, one way modular switch, ISI marked |
| 21 | S.P. 15/16 amps, one way modular switch, ISI marked |
| 22 | 3 pin 5/6 amps modular socket outlet, ISI marked |
| 23 | 6 pin 15/16 amps modular socket outlet, ISI marked |
| 24 | 6 amps. to 32 amps. ratings , SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 25 | 40 amps., 2 pole isolator |
| 26 | 63 amps., 2 pole isolator |
| 27 | 3 pole MCCB, 125A, 16kA Ics=100% Icu andOperational Voltage 690V |
| 28 | Supplying of 300 mm sweep metallic heavy duty 900 rpm exhaust fan suitable for operation on 230V, 50 Hz single phase AC supply complete with louvers / shutters in the existing opening including making the hole to suit the size of the above fan making good the damage and connections etc. as reqd. |
| 29 | Supplying of fresh air fan 200 mm sweep with shutter and louver in the existing opeining , including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. |
| 30 | Supplying 400mm sweep wall mounted cabin fan with speed regulator oscilatting type i/c testing & commsisioning suitable for 230volt 50Hz AC supply etc as reqd. |
| 31 | Supplying & Laying of following sizes of XLPE insulated and PVC sheathed aluminium conductor armoured cable in pipe/HUME/Surface as reqd. |
| 32 | a) 3 x 6 sqmm XLPE Al. Armoured cable |
| 33 | b) 3 x 10 sqmm XLPE Al. Armoured cable |
| 34 | Comprehensive Maintenance of Air Conditioners and Water coolers (AC Repari work shall commence in 01.02.2026 onwards) Supply & Charging R-22/410/407/32/134a gas in the existing WTAC/STAC of 1.5/2.0 TR unit and water coolers i/c pressure testing, flushing the system and Gas Charging complete as reqd. |
| 35 | Supplying & Fixing 25 mm diameter PVC heavy duty pipe for drainage in the existing split type AC unit with supporting clamps etc . complete as reqd. |
| 36 | Supplying and fixing of Extra copper refrigerant piping of 5/8”, 3/8”, 1/4” i/c nitrile rubber insulation wrapping etc. complete as reqd. |
| 37 | Providing and fixing of 3 core 2.5 sqmm PVC insulated and PVC sheathed bright annealed copper conductor cable for communication between indoor unit/outdoor unit/controllers inside building in existing steel/PVC Conduit/ surface/ existing channel, i/c making connection etc as reqd. |
| 38 | Replacement of following capacity compressor in the existing WTAC/Split AC with new one and making copper pipe connection, brazing pressure testing and supplying and charging refrigerant gas i/c cutting the copper piping dismantling of the old compressor complete as Reqd. |
| 39 | a) 1.5 TR capacity |
| 40 | Replacement of upto 1 TR capacity compressor in the existing water cooler with new one and making copper pipe connection, brazing pressure testing and supplying and charging refrigerant gas i/c cutting the copper piping dismantling of the old compressor complete as Reqd. |
| 41 | Supplying and replacement of wornout/defective copper condensor coil with new one in same size of design suitable for following capacity split type AC out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd. |
| 42 | a) 1.5/2.0TR capacity |
| 43 | Supplying and replacement of wornout/defective copper cooling coil with new one in same size of design suitable for following capacity split type AC out door unit i/c breezing the all copper pipe with all distribution joints of make sure the connection with capiliary tube linking dryer duly proper etc pressure testing leak detection, vaccumizing the unit, gas charging etc complete as reqd. |
| 44 | a) 1.5/2.0TR capacity |
| 45 | Replacement of non repairable inverter PCB in existing indoor/outdoor unit of STAC and WTAC complete etc as reqd. |
| 46 | Replacement of non repairable non inverter PCB in existing indoor/outdoor unit of STAC and WTAC complete etc as reqd. |
| 47 | Dismantling, shifting and reinstallating of existing 1.5TR/ 2.0TR capacity STAC (indoor and outdoor unit) including repairing the damaged caused due to dismantling within same office etc as required. |
| 48 | Providing & replacement WTAC/STAC fan motor Capacity 1/4 to 1/8 hp including dismantling the burnt motor from the existing unit & fixing of new motor, making connections testing, commissioning etc.as reqd. |
| 49 | Supplying and replacement of following defective spare parts in the existing AC unit with new one i/c connection testing etc. complete as required. |
| 50 | a) Running capacitor - 36 Mfd/45 Mfd |
| 51 | b) Starting capacitor- 80/100 Mfd |
| 52 | Supply and fixing of 15/16Amp 3pin top plug including connection complete as reqd. |
| 53 | Supplying and fixing stand for the outdoor unit of the STAC made of MS duly powder coated complete etc as required. |
| 54 | Preventive Maintenance of 50/500 LPH and all type RO plants connected with/within water coolers i/c services (cleaning of all Filters), repair/ replacement of all electrical and electronic spare parts and replacement of consumables and non consumables items as when required like Pre Filter, Sediment Filter, Pre Carbon Filter and Post Carbon Filter alongwith membranes, pump and its accessories etc. as required. a) Per Visit for 8 hours RO Technician |
| 55 | Supply & Replacement of RO TFC Membrane 75 GPD for compatible Eureka Forbes and Ion Exchange make i/c testing, commissioning etc. as required, old dismantle shall be retained by the contractor. |
| 56 | Supply & Replacement of RO TFC Membrane 150 GPD Eureka or compatible Eureka Forbes and Ion Exchange make i/c testing, commissioning etc. as required, old dismantle shall be retained by the contractor. (old dismantle shall be retained by the contractor.) |
| 57 | Supply and replacement of Particulate / Sediment/ Pre-Filter 10/20\\" or compatible Eureka Forbes and Ion Exchange makei/c Leak testing, commissioning etc complete as reqd at site. Dismantle shall be retained by the contractor. |
| 58 | Supply and replacement of Pre /Post Carbon Filter 10/20\\" or compatible Eureka Forbes and Ion Exchange make i/c Leak testing, commissioning etc complete as reqd at site. Dismantle shall be retained by the contractor. |
| 59 | Supply and Fixing of 20\\"x 2.5\\" Pre Filter bowl assly to prevent of excess silt in feed water to RO machines i/c Leak testing, commissioning etc complete as reqd at site. |
| 60 | Supply and fixing of Automated Switching on/off device as per level of water in storage tank/ Water cooler etc as reqd. |
| 61 | Suppy & Replacement of the defective spare Parts in existing Water PurificationSystem to make the machines operational i/c testing , commissioning etc. complete as reqd. |
| 62 | SMPS 24/48V |
| 63 | RO Pump 48V |
| 64 | Solenoid Valve 24V |
| 65 | Push type chrome Platted Brass Tap |
| 66 | Providing and replacing of old defected/ rusted RO body parts with new one in existing or compatible Eureka Forbes and Ion Exchange make |
| 67 | Supply and replacement of defective Top Cover of of existing AG Reviva 50 LPH RO Water Purification system i/c testing &commissioning etc complete as reqd. |
| 68 | Supply and replacement of defective Wall mount Stand of existing AG Reviva 50 LPH RO Water Purification system i/c testing &commissioning etc complete as reqd. |
| 69 | Credit for dismantle materials |
| 70 | Assorted Ceiling Fans/exhaust fan |
| 71 | Assorted Switch /sockets |
| 72 | Assorted all type indoor/outdoor fittings |
| 73 | Assorted SP/DP MCB upto 63amp |
| 74 | Assorted MCCB |
| 75 | Assorted wire with insulation copper |
| 76 | compressor 1TR/1.5TR/ 2TR |
| 77 | Refrigerant copper pipe |
| 78 | cooling/condensor coil |
| 79 | PCB Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
TodayOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender