Tender for Special Repair Of Lt Ug Cable, Lt Panel, Street Light Pole Along With Connected Wks At Harding Line And Certain Areas Of Hq Jl Wng Under Ge Belgaum
BOQ
| Sl. No. | Item Description |
| 1 | S&F IN REPAIR new generation energy saving and environmental friendly long life LED street light made up of innovative die cast aluminium housing high power LED as lighting source with IP-65 power consumption 70/72watt with minimum 120lum/watt, complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm x 3 core through copper connectors from junction box to security lights, complete all as specified and directed. |
| 2 | Excavation in trenches not exceeding 1.5m wide and not exceeding 10 Sq.m on plan area and not exceeding 1.5m deep in any type of soil, for laying of cable/pipes etc., including taking out old bricks and separating serviceable & unserviceable bricks, cleaning & stacking serviceable bricks for re-use, complete all as specified. |
| 3 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil, as in any type of soil, complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming. |
| 4 | Removal of excavated material [Soil] to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified. |
| 5 | M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge. |
| 6 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge. |
| 7 | M&L for Boring under road / pavement / hard standing of size 100mm bore dia at suitable depth by trenchless technology through any type of soil strata, using ultra sound technique and necessary machine with and including HDPE pipe of 100mm bore dia of PN 10 nominal pressure, ISI marked, with and including removing surplus soil to a distance not exc 50m, complete all as specified and as directed. Note: Location of boring shall be as directed by Engineer-in-Charge and noting shall be paid for change in strata if any at site. |
| 8 | Supply, laying, testing and commissioning of LT XLPE insulated, screened with extruded PVC inner sheathed, PVC bedded, galvanised steel strip armoured electric power cable [heavy duty] of size 4.0core x 10.0Sqmm, with stranded aluminium conductor, 1100 volts grade, suitable for earthed system with and including cable glands, ferrules and connected accessories, laid in trenches or ducts or through the pipe etc., including taking down old u/s cable, complete all as specified. Note: Necessary excavation & earth work, brick protection & sand cushioning shall be measured and paid separately under respective items. |
| 9 | All as per Serial Item No. 8 here-in-before but for cable of size 4.0core x 16.0Sqmm. |
| 10 | All as per Serial Item No. 8 here-in-before but for cable of size 3.5core x 35.00Sqmm. |
| 11 | All as per Serial Item No. 8 here-in-before but for cable of size 3.5core x 120.00Sqmm. |
| 12 | All as per Serial Item No. 8 here-in-before but for cable of size 3.5core x 240.00Sqmm. |
| 13 | Supply and laying in repair DWC HDPE Pipe 60mm dia, with ISI marked (IS 14930 Part-1&2), laid in trenches / floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables / road crossings etc., complete all as specified. |
| 14 | Supply and laying in repair DWC HDPE Pipe 100mm dia, with ISI marked (IS 14930 Part-1&2), laid in trenches / floors & fixed on wall/ pole with and including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables / road crossings etc., complete all as specified. |
| 15 | S&F IN REPAIR new generation energy saving and environmental friendly long life LED flood light made up of innovative die cast aluminium housing high power LED as lighting source with IP-66 power consumption 120watt with minimum 120lum/watt, complete input voltage of 150-240 Volt (nominal rated voltage 240 Volt) including pvc coated twisted copper cable 1.5 sqmm x 3core through copper connectors as requirement at site, complete all as specified and directed. |
| 16 | M&L for IN REPAIR Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with RCC 1:2:4 type B1 40mm thick cover slab with 8mm dia TMT bars @150mm c/c in bothways, suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note : Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item. |
| 17 | Supply, install and testing for maintenance free chemical earthing of dual pipe technology of 3mtr long with outer pipe dia 88mm and inner pipe dia 48mm, the pipes are properly galvanised for 80-120 micron and wall thickness of inner pipe 3 mm and 2 mm of outer pipe with copper coating on outer surface, terminal for connection of 75mm x 6mm with 2 holes of 14 mm dia, fast electrode filled with highly conductive material with sealing at boath ends with lead terminal of 75mm x 6mm at top along with 2 bags of 25Kgs each of earth enhancing compound of PH value 7-8 duly tested and certified by any international accredited NABL / BIS accredited laborartory with reffering to protocol IS 1350 and IEC 62321/111/54/CDV. The content of mercury and hexa chromium should be below detection level. The electrode should be tested for salt spray test as per BIS 117-09 for corrosion for minimum 500 Hrs. The electrode should be duly tested and certified by CPRI for a min short circuit current of 42k amps for 1 Sec with initial pick of 8.2K amp, connected to copper strip 20mm x 3.15mm thick earth strip by means of bolts, nuts, check nuts and washers of copper with 40mm dia medium grade Gl pipe as a protection up to 7.5m long and RCC pit with cover and connected to earthing test point, including testing on completion, complete all as specified and as directed. |
| 18 | S&F IN REPAIR LT Panel as per IEC 61439, Outdoor type, floor mounted free standing dust and vermin proof panel / DB with IP-55 protection, CPRI approved OEM, frame fabricated out of 40mmx40mm x 4mm MS angle iron, made with 3.15mm thick CRCA sheet for entire outer panel and 1.6mm thick CRCA sheet 40mmx4mm MS flat Iron for inner compartments with separate cubicle chamber with cable alley with minimum 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, all MCCBs must be have thermal magnetic relrase, busbar chamber and switchgear compartments, provision in cable alleys for bottom cable entry for incoming & outgoing cables, fixing danger notice plate, with and including erection, testing and commissioning, complete all as specified and directed including the following fixtures and fitments:- |
| 19 | (a) Aluminium bus bar four strips 600Amps, 415 volts, fixed on epoxy insulated with panel fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set. (b) Incoming:- MCCB 04 Pole, 315Amps with ultimate breaking capacity Icu-25KA at 415 volts , adjustable type with thermal and magnetic settings - 01 No (Ics=Icu=100%) (c) Outgoing:-MCCB 04 Pole, 200Amp with ultimate breaking capacity Icu- 25KA at 415 volts, adjustable type with thermal and magnetic settings - 01 No (Ics=Icu=100%) (d) MCCB 04 Pole, 100Amp with ultimate breaking capacity Icu- 16KA at 415 volts, adjustable type with thermal and magnetic settings - 02 No (Ics=Icu=100%) (e) MCCB 04 Pole, 63Amp with ultimate breaking capacity Icu- 16KA at 415 volts, adjustable type with thermal and magnetic settings - 01 No (Ics=Icu=100%) (g) Digital type volt meter 0-500 volt - 1Set., Digital type Ammeter 0-400Amp, Indication lamps R,Y,B LED type with 3 Nos – 1 set, Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's. Note :- Panel drawings & make of MCCB/SDFU will be submitted by contractor for approval of GE before ordering the panel. |
| 20 | all as per item no 18 butBusbars:-TPN-Not less than 660 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming:- (i) MCCB 400 A, 4 Pole, 50KA with thermal magnetic release (Ics=Icu=100%) - 01No (ii) DG incomer 400 amp 50 ka (with adjustable electronic release)-01 (iii) change over switch on load 4 pole 400 amp -1(ii) CT's 400/5 -03 No., (iii) Digital type Ampere Meter 0 - 400 A with selector switch -01 No. (iv) Digital type Ammeter-01 No., (v) Digital type Voltmeter with selector switch -01 No.(vi) Phase Indicating lamps -03(vii) Control fuses / MCB -03 No. |
| 21 | Outgoing:-(i) MCCB, 4 pole 160A, 16 KA, thermal magnetic release 160-200 Amp = 02 No (ii) MCCB, 4 pole 200A, 16 KA, thermal magnetic release 160-200 Amp = 02 No(iii) MCCB 4 POLE 100AMP 16 KA-3No. (iv) MCCB 4 POLE 63AMP, 16KA -3Nos. |
| 22 | all as per item no 18 butBusbars:-TPN-Not less than 400A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming:- (i) MCCB 250A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 01No (ii) CT's 200/5 -03 No., (iii) Digital type Ammeter-with selector switch -01 No (iv) Digital type Voltmeter with selector switch -01 No.(v) Phase Indicating lamps -03(vi) Control fuses / MCB -03 No. Outgoing:- (i) MCCB 100A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 04No (ii) Timer & Protection MCB (iii) Manual auto control switch duly windup to terminal block for connecting street light circuits. |
| 23 | all as per item no 18 butBusbars:-TPN-Not less than 400A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming:- (i) MCCB 160A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 01No (ii) CT's 200/5 -03 No., (iii) Digital type Ammeter-with selector switch -01 No (iv) Digital type Voltmeter with selector switch -01 No.(v) Phase Indicating lamps -03(vi) Control fuses / MCB -03 No. Outgoing:- (i) MCCB 125A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 02No (ii) MCCB 100A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 03No |
| 24 | all as per item no 18 butBusbars:-TPN-Not less than 600A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming:- (i) MCCB 200A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 01No (ii) CT's 200/5 -03 No., (iii) Digital type Ammeter-with selector switch -01 No (iv) Digital type Voltmeter with selector switch -01 No.(v) Phase Indicating lamps -03(vi) Control fuses / MCB -03 No. Outgoing:- (i) MCCB 125A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 02No (ii) MCCB 100A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 04No |
| 25 | all as per item no 18 butBusbars:-TPN-Not less than 500A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming:- (i) MCCB 200A, 4 Pole, 25KA with thermal magnetic release (Ics=Icu=100%) - 01No (ii) CT's 200/5 -03 No., (iii) Digital type Ammeter-with selector switch -01 No (iv) Digital type Voltmeter with selector switch -01 No.(v) Phase Indicating lamps -03(vi) Control fuses / MCB -03 No. Outgoing:- (i) MCCB 63A, 4Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 02No (ii) MCCB 100A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%)-03No |
| 26 | all as per item no 18 butBusbars:-TPN-Not less than 300A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming:- (i) MCCB 125A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 01No (ii) CT's 200/5 -03 No., (iii) Digital type Ammeter-with selector switch -01 No (iv) Digital type Voltmeter with selector switch -01 No.(v) Phase Indicating lamps -03(vi) Control fuses / MCB -03 No. Outgoing:- (i) MCCB 100A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 01No (ii) MCCB 63A, 4 Pole, 16KA with thermal magnetic release (Ics=Icu=100%) - 02No (iii) MCCB 32A, 4 Pole, 16KA with contactor 32Amp - 01No (iv) Timer & Protection MCB (v) Manual auto control switch duly windup to terminal block for connecting street light circuits. |
| 27 | All asper item no 18 butBusbars:-TPN-600 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming:- (i) MCCB 400A, 4 Pole, 50KA with thermal magnetic release (Ics=Icu=100%) - 01No. (ii) CT's 630/5 -03 No., (iii) Digital Ammeter with selector switch -01 No., (iv) Digital Voltmeter with selector switch -01 No.(v) Phase Indicating lamps -03(vi) Control fuses / MCB -03 No. Please Enable Macros to View BoQ information |
| 28 | All asper item no 18 butBusbars:-TPN-600 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set.Incoming:- (i) MCCB 400A, 4 Pole, 50KA with thermal magnetic release (Ics=Icu=100%) - 01No. (ii) CT's 630/5 -03 No., (iii) Digital Ammeter with selector switch -01 No., (iv) Digital Voltmeter with selector switch -01 No.(v) Phase Indicating lamps -03(vi) Control fuses / MCB -03 No. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender