Tender For Mayapur Water Supply Scheme (Rbf)
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Oct 2026
0 days left
EMD
3.86 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chamoli → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Mayapur Water Supply Scheme (Rbf)
BOQ
| Sl. No. | Item Description |
| 1 | Rates for Mayapur Water Supply Scheme (RBF) |
| 2 | Dismantling of RoadFor Crossing of pipes on Road |
| 3 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 4 | Excavation in soil Mixed with single boulders etc. required the use of specials T&P, if any for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. |
| 5 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Cement Concrete |
| 6 | For Pipe Laying |
| 7 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 8 | Excavation in soil Mixed with single boulders etc. required the use of specials T&P, if any for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. |
| 9 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Cement Concrete |
| 10 | Restoration of RoadFor Crossing of pipes on Road |
| 11 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 12 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge.(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). |
| 13 | For Pipe Laying |
| 14 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 15 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. |
| 16 | EARTHWORK FOR CUTTING, FILLING AND DISPOSAL OF SURPLUS EARTH |
| 17 | Excavation in soil mixed with shingle bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling,waterring and ramming of Excavated earth in the trenches. |
| 18 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 19 | PROVIDING AND LAYING OF PIPES |
| 20 | Laying and Jointing of MSERW Pipes and fitting of work with testing of pipe line etc complete.100 mm dia 5.60 mm thick. |
| 21 | Supply of all materials, labour, T & P etc. and Construction of R.C.C Anchor Blockas per type design complete |
| 22 | Making flange joints between MSERWpipes and MSERW Specials, including costof jointing material like nut & Bolts, Parkingof Standard quality and make with testing of100 mm dia |
| 23 | Providing Push-on-joint to centrifugal(spun)MSERW pipes including testing ofjoint and including the cost of rubber Gaskate100 mm dia. |
| 24 | Valves & Valve Chambers |
| 25 | Supply & fixing of following sizes of valves including carting the same up to side of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respectSluice Valve ( P.N 1.6 )100 mm dia |
| 26 | C.I. Air valve (Double Acting) 80mm |
| 27 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design |
| 28 | Providing, lowering, laying, aligning, fixing in position jointing in pipeline following dia D/F Plunger valve (Flow Control Valve) PN 1.6 class with electrical actuator suitable for SCADA compatibility complete (including jointing & jointing material) including all material,labour, testing and commissioning as per Technical Specification &as per direction of Engineer.100 mm diameter |
| 29 | Providing & fixing Woltman type bulk meter inline type,flanged with integral mounted display and all necessary fittings etc. complete.100 mm dia |
| 30 | Provision of Boundary Wall at Source |
| 31 | Estimation for Boundary Wall at Source with all required accessories and material etc. complete. |
| 32 | Distribution MainDismantling of RoadFor Crossing of pipes on Road |
| 33 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metrelead as per direction of Engineer-in- Charge. |
| 34 | Excavation in soil Mixed with single boulders etc. required the use of specials T&P, if any for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches. |
| 35 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. CementConcrete |
| 36 | For providing connections |
| 37 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. |
| 38 | Excavation in soil Mixed with single boulders etc. required the use of specials T&P, if any for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavatedearth in the trenches. |
| 39 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Cement Concrete |
| 40 | For Pipe Laying |
| 41 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of |
| 42 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Cement Concrete |
| 43 | Restoration of RoadFor Crossing of pipes on Road |
| 44 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 45 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). |
| 46 | For providing connections |
| 47 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 48 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (Note:- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/ recoverable separately). |
| 49 | For Pipe Laying |
| 50 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost). |
| 51 | Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. |
| 52 | EARTHWORK FOR CUTTING, FILLING AND DISPOSAL OF SURPLUS EARTH |
| 53 | Excavation in soil mixed with shingle bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to1.5M and lead up to 30M with back filling,waterring and ramming of Excavated earth in the trenches.(40% of Total Quantity) |
| 54 | Disposal of building rubbish / malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 55 | LAYING OF PIPES |
| 56 | Laying and fixing of G.I. pipes complete with G.I.fittings including trenching and required accessories etc.15 mm dia |
| 57 | 40 mm dia pipe |
| 58 | 50 mm dia pipe |
| 59 | 65 mm dia pipe |
| 60 | 80 mm dia pipe |
| 61 | 100 mm dia pipe |
| 62 | 125 mm dia pipe |
| 63 | 150 mm dia pipe |
| 64 | Laying of MSERW Pipe. 200 mm dia. (5.20 mm thick) |
| 65 | Making Conections of GI Distribution Branch with GI Main of Following Sizes by Provided & Fixing Tee.including cutting & threding the pipe etc.50 to 80 mm nominal bore |
| 66 | Valves & Valve Chambers |
| 67 | Supplying and fixing of following sizes of valves including carting the same upto site of work and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete .C.I/DF Sluice/ Gate ValvePressure PN 1050 mm dia |
| 68 | 65 mm dia |
| 69 | 80 mm dia |
| 70 | 100 mm dia |
| 71 | 125 mm dia |
| 72 | 150 mm dia |
| 73 | 200 mm dia |
| 74 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, withC.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. |
| 75 | Providing, Supplying and fixing of Pressure Reducing Valave in pipe line including etc. complete as per standard/ technical speccification and direction ofEngnieer-in- Charge.100 mm diameter |
| 76 | Providing, lowering, laying, aligning, fixing in position jointing in pipeline Plunger valve (Flow Control Valve) PN 1.6 class with electrical actuator suitable for SCADA compatibility complete (including jointing & jointing material) including all material,labour, testing and commissioning as per Technical Specification & as per direction of Engineer.100 mm diameter |
| 77 | Water Connections |
| 78 | Supplying, fitting and fixing brass ferrule including connection of following dia. and upto 450 mm long with screw, jamnut, sockets etc., complete in alll respect, including cutting trenches in all sorts of soil and filling up the trenches as per Unit Estimate and direction of theEngineer-in-charge.15mm |
| 79 | Providing and fixing compatible class-B water meter as per 779- 1994 or ISO 4064-2005, inferential type multijet, magnetically coupled having dry dial brass bonze body, copper cane/ stainless steel register with 5 mm thick glass dialer with connecting oieces etc complete.DN 15mm as per technicalspecification |
| 80 | Proving and fixing Polypropelene water meter box of different size inpostion etc complete.polypropylene water meter box-black of size(393mm x178mmx 160mm) |
| 81 | Providing & fixing ultrsonic water flow meter for bulk pipe lines inline type, flange end with integral mounted, flow rate & Totaliser display, battery operated (with 5 year battery life) communication: UART/RS485, suitable against antifraud attempts etc. including allnecessary fittings complete.At Outlet of GLSR100mm |
| 82 | RCC Ground Level Service Reservoir |
| 83 | Supply of all materials,T&P etc and construction of RCC CWR of following Capacities of KL with M.S ladder outside the tank and Aluminium Ladder Inside the TankM.S M.H Cover with locking Arrangement,Lighting Conductor as per electricity rules, Water level Indicators Supply and fixing of outlet inlet over flow wash out pipes with necessary sluice valve pipe piece (including cost of materials) flooring0.6 M wide apron, Painting on tank body verticals pipes Ladder M.S, M.H.Cover Ventilators Colums etc complete with approved with water proofing (apex ) Enamals paint testing filling water for testing purpose etc. including supply of verticals pipes and specials Assuming bearing capacity as 8MT/ M^2250 KL GSLR |
| 84 | INJECTING DOSER: |
| 85 | Supply & Installation of Microprocessor based chemical dosing system suitable for providing Automatically variable controlled dose of chemical to maintain required ppm of chemical with required accessories & 200L TRS tank, suction & injecting valves etc. |
| 86 | Supply & Installation of Residual chlorine analyser suitable to monitor, display & transmit over 4- 20mA/Rs485 communication port Residual chlorine value in water linethrough sample water. |
| 87 | cartage of material |
| 88 | cartage of materials from nandpryag store to site of work |
| 89 | PUMP HOUSE FOR WATER SUPPLY |
| 90 | Excavation of earth in foundation soil mixed with single, bajri etc. including lift up to 1.5 m and lead up to 50 m filling watering and ramming of excavated earth in to the trenches or in to the space between the building and the sides of foundation trench |
| 91 | PCC in 1:4:8 in foundation with cement, local sand and 40 mm gauge stone ballast including supply of material, labour, T&P etc.for proper completion of work. |
| 92 | First class brick work in 1:6 cement and local sand including supply of all material, labour, T&P etc. complete.(IN FOUNDATION &PLINTH) |
| 93 | First class brick work (one and half brick thick) in 1:6 cement and coarse sand including supply of all material, labour, T&Petc. in super structure. |
| 94 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m andlift upto 1.5 m |
| 95 | 12 mm thick PC plaster in 1:6 cement andlocal sand mortar including supply of all labour material, T&P etc. all complete |
| 96 | RCC 1:1.5:3 with cement, coarse sand and 20 mm gauge stone ballast in lintals, beams, sunshades door and window sills, bed plates including supply of reinforcement and its bending but including its fixing and binding the same with 5 mm thick binding wire |
| 97 | Same as above but for slab |
| 98 | Mild steel or iron work in plain work such as RCC work brought to required shapeincluding supply of steel & its bending. |
| 99 | Mild steel or iron work in heavy section &sizes as door frames, windows, grills, gratings etc. wrought to required shape including supply of steel sections, hinges nuts & their fixing required for proper completion ofwork. |
| 100 | 40 mm thick PC 1:2:4 with cement coarse sand and 20 mm gauge stone ballast in flooring, laid in panels finished with 3 mmfloating coat of neat cement. |
| 101 | 75 mm thick base concrete consisting of1:4:8 cement, local sand & 40 mm stone ballast. |
| 102 | Steel work welded in built up section/framed work including cutting, hoisting, fixing (45 x 45 mm x 5 mm angle iron MS Chaukhats in doors and windows) |
| 103 | Supply and fix 35 mm thick flush ply door & window shutters fully glazed and including fixing of hinges bolts locks, handles and other fittings including supply of all fittings labour, materials, T&P etc. all complete. |
| 104 | S/F of 4mm thick glazing in window shutterincluding supply of all required. |
| 105 | Painting or warnishing new iron work or wood work with one coat of primer & two coats of approved quality synthetic enamel paint or varnish including. Supply of all material, labour T&P etc. required for propercompletion of work. |
| 106 | Colour washing such as green, blue or buff togive an even shadeNew work (two or more coats) with a basecoat of white washing with lime |
| 107 | Distempering with oil bound washable distemper of approved brand and New work (two or more coats) over and including water tinnable priming coat with cement primer |
| 108 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer all complete. |
| 109 | Stone tile work for wall lining upto 10 mheight with special adhesive over 12mm. 8mm thick (mirror polished and machine cut edge). Granite stone of any colour and shade. |
| 110 | Supply & fixing of white ciremic Tile in inner side of wall upto door lable of Pump house |
| 111 | Supply & laying of Kota stone tile in floor |
| 112 | Earthing with copper earth Plate 600 mmX 600 mm X 3 mm thick including accessories, and proving masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. withcharcoal/ coke and salt as required. |
| 113 | Providing and fixing 6 SWG dia G.I. wire onsurface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wirinQ/ cable as required. |
| 114 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 115 | Supply installation Testing & commisioningof the following LED lights.1x20W T5 TubeLight |
| 116 | 1x 10W Square Light for Staircase and Lobbyarea |
| 117 | 1x 10W recess Square Light for Reception |
| 118 | Supply and fixing of fans with louvers,complete with all accessories as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender