Power Government Departments Closing in 12 days TDR #57749797

Tender For Construction Of 132Kv Gss Tehroli

Issued by Government Departments · Kota, Rajasthan
Tender Value
29.14 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
12 days left
EMD
58285
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kota → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 132Kv Gss Tehroli

BOQ

Name of Work:- Construction of 132KV GSS Tehroli
Sl. No. Item Description
1EARTH MESH WORKLaying of earth mesh with 25mm I 28mm dia. M.S. Rod at a depth of 0.80 metre from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M. S. Rods from site store to locations, welding of M. S. Rod to M. S. Rod along the length, at crossings and with earth electrodes as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 0.80 metre below top level of foundations (M. S. Rod of above sizes & M. S. Flat as required shall be made available by RVPN). (a) In case electricity is made available by RVPN without charges i) Any soil, soft rock other than hard rock
2Laying of earthing risers of 50x6mm/50x10mm/50x12mm size M.S Flat at a depth of 0.80 m,eters from top level of foundations, including excavation of trench of required depth and backfilling of the same, transportation of M.S Flat from site store to locations, preparation of risers bending as per requirement ( after heating if necessary), fixing on and welding / bolting to equiopment/ structure and peaks of structures, laying in the trench, welding to the earth mesh of M.S Rods as per drawing, including welding of extra length of M.S Flat of required, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, painting of all surface of risers above ground level with red oxide and green paint, for the type of soil prevalent at 0.80 meter below top level of foundations ( M.S Rod of above sizes & M.S Flat as required shall be made available by RVPN) (a) In case electricity is made available by RVPN without charges i) Any soil, soft rock other than hard rock
3Placing / Driving of earth electrode of 25 / 28mm dia. M. S. Rod of length 3.30 meters (approx.) to a depth of 3.80 meters from the top level of foundations, including excavation of pit as required and back filling of the same, transportation of M. S. Rod from site store to locations, cutting of M. S. Rod to desired length, preparation of one end as spike if necessary, welding of earth electrode to earth mesh of M. S. Rod as per drawing, application of bitumen compound and covering with bitumen impregnated tape on all welded joints, for the type of soil prevalent at 3.80 metres below top level of foundations (M. S. Rod of above sizes & M. S. Flat as required shall be made available by RVPN). (a) In case electricity is made available by RVPN without charges. i) Any soil,soft rock other than hard rock
4ERECTION OF SUB STATION STEEL STRUCTURES columns, beams lighting mast and equiopemtn structures ( excluding Circuit Breakers and Capacitors Banks ) of all types including transportation of structure members nuts & bolts, washers etc from site store to locations , their assembly, placing on foundation, fixing of template, with foundation bolts as required, levelling and preparing for grouting as required but excluding grouting, erection after grouting and tightening & punching of nuts & bolts. ( Maximum height of structures upto 20 meters.
5BUS - BAR WORKSTRINGING of 220 KV, 132 KV, 33 KV & 11KV Bus Bar of ACSR & Tarantulla conductor, including transportation of conductor, disc insulators and tension hardware from site stores to location, laying and cutting required length of conductor, cleaning and assembly of disc insulators as required along with fitting of bolted type or compression type tension hardware as made available, making up at one end, stringing of conductors between the beams with specified sag and tension, also equalizing sag and fitting spacers and spacer T-clamps for twin conductor, for three phases of conductors in each bus-section.(Per jumper basis)
6Any Single Conductor
7Any Double Conductor
8JUMPERS of any conductor (3 nos. Y- type) between bus to equipment, or between equipment to equipment or between bus to bus, including transportation of conductor, disc insulators and hardware from site stores to locations, cleaning and assembly of disc insulators as required along with fitting of suspension hardware and erection as required, cutting required length of conductor, making connections, fixing of spacers & spacer T-clamps as required, tightening of clamps 1connectors, dressing, etc., for three phases. (Per jumper basis) Any Conductor
9STRINGING OF Earth wire ( suze 7/3.15mm or 7/4.00mm ), including transportation of eathwire, tension hardwares, etc from site store to locations lasying and cutting required length of earthwire, fitting of bolted type or compression type hardware as made available ( comppression machine shall be provided by RVPN on rent free basis), making up at one end stringing of earthware between structure peaks with specified sag and tension, jumpering and connecting earth bonds for single earth wire.
10EARCTION OF SUB-STATION EQUIPMENTSI) Erection of 33/0.4 KV Station transformer upto 500 KVA on existing masonary platform including transportation of transformer & accessories from site store to location erection of Horn Gap fuse set jumpering from isolator to Horn Gap to transformer.
11Erection of C.T / P.T /CVT/ Series Reactor / RVT / NCT with clamps & connectors on already erected steel structure including transportation from site stores to locations, fabrication of base frme, fixing of terminal connectors, tightening of nuts & bolts etc complete in all respect.
12ii) 132KV CT/PT/CVT/
13iii) 33 KV CT/PT
14Erection of LA on already erected steel structure including transportation of LA, clamps & connectors surge counter etc from site stores to locations, fabrication of base frame, fixing of terminal connectors surge counter, tightening of nuts & bolts complete in all respect.
15ii) 132 KV
16iii) 33 KV
17Erection of Isolators(Motorised/Non motorised) on already erected steel structure including transportation of base frame, P. I.'s, contacts, mechanism box, clamps & connectors, etc. from site store to locations, minor fabrication as required, and fixing of terminal connectors, etc.,adjustment! alignment of isolator and its earth blade, if provided, for their smooth operation and final adjustment if required after jumpering including erection of PI
18ii) 132 KV a) Without Earth Blade
19ii) 132 KV b) With Single Earth Blade
20iii) 33 KV a) Without Earth Blade
21iii) 33 KV b) With Single Earth Blade
22Erection of Wave trap on already erected structure beam, Including transportation of wave tap, disc insulaltors,hardware Clamps and connectors,etc. from site store to locations,cleaning & assembly of disc insulators along with fitting of suspension Arrangement and erection, fixing of terminal connectors etc. ii) 132KV
23Erection of 132 KV Circuit Breakers, including transportation of equipments, structure members, nuts & bolts, clamps & connectors, accessories etc from site store to location, assembly of support structure, their placing on foundation, levelling and preparing for grouting as required, but excluding grouting assembly/ placing of support columns / poles mechanism box/control cubicle, and other accessories as per manufacturer's drawings, fitting of SF-6 gas pipeline, fabrication of air / oil pipeline as required, electrical wiring from pole to control cubicle, fixing of terminal connectors as required but excluding commissioning of CB for all types of operating mechanism, as required. ii) 132 KV
24Erection of 33 KV Circuit Breakers including transporation of equipemt, structure members nuts & bolts, clamps & connectors etc from site store to location assembly of support structure their placing on foundation leveling and preparing for grouting as required but excluding grouting assembly/placing of poles, mechanism box etc on support structure as per mannufacturer's drawings, fittings of terminal connectors etc but excluding commissioning of C.B. i) 33 KV Outdoor Type (VCB/SF-6)
25Erection of Post Insulators on already erected structures including transportation of P. I. 's, nuts & bolts, clamps & connectors, etc. from site store to locations, fabrication of base frame & assembly if required, fixing of clamps, etc.
26ii) 132 KV
27iii) 33 KV or 11 KV
28Erection of 132 KV Class EHV Transformer ( tank already placed on foundation with wheels) including transportation of accessories from site store to locations, erection of HV, IV,LV & Neutral bushings, main & OLTC conservators, radiators, equalizing pipe line marshalling kiosk etc aas per manufacturer's drawing preparation of oil, oil filling dehydration of transformer (filter machine, oil tank & operating staff shall be provided by RVPN ), electrical wiring from individual equipment e.g, Buchholz relay, MOLG, OSR etc to marshalling kiosk etc, but excluding testing & commissioning of transformer. a) If electricity is available & arranged by RVPN without charge i) Transformers received oil filled
29Erection of control & Relay Panles complete in all respect including transportation from site store to control room placing on foundation / cable trench as per layout, interconnection between Control & Relay panels and with existing panels, fixing of side/ top covers and doors, earthing to existing earth strip in control room, connection of bus wiring to existing panel and between control and relay panel, as required.
30ii) Duplex Panel
31iii) Simplex Panel, DC Panel, RTCC Panel, PLCC Panel etc
32iv) LT Panel
33Erection of Marshalling Kiosk/ Line Matching Unit (LMU) / Line Matching & Distribution Unit (LMDU) complete in all respect including transportation from site store to location, placing on foundation / cable trench as per layout preparing for grouting of foundation bolts but excluding grouting etc.
34I) 132 KV Marshalling kiosk
35ii) 33KV Marshalling Kiosk
36Erection of Battery Charger complete in all respect including transportation from site store to location placing on foundation / cable trench as per layout etc.
37ii) 110 Volt DC,200 AH
38iii) 48 Volt DC, 600/400/200 AH
39BATTERY SETAssembly, erection and commissioning of Lead Acid Battery Set including transportation of cells, battery stand, electrolyte, nuts & bolts and accessories from site store to battery room, assembly of wooden stand, placing the cells on stand, making their interconnection, filling of electrolyte, giving two cycle of charge and discharge after initial charging as per procedurerecommended by battery manufacturer.
40a) If electricity is available & arranged by RVPN without charges ii) 110 Volt DC,200 AH
41a) If electricity is available & arranged by RVPN without charges iii) 48 Volt DC,600/400/200 AH
42LAYING AND TERMINATION OF CABLESControl Cablesi) Laying of PVC insulated unarmoured / armoured control cables of 1.1 KV grade with copper conductor in cable trenches as per specification as required, including transportation of cable drums from site them on cable racks / cable trays / cable batten & dressing, including removing and re-fixing trench covers as required making necessary connections testing cable marking on both the terminating ends, etc as required for all size from 2c x 2.5sqmm to 20cx2.5mm, 4c x 4sqmm and 4cx6sqmm a) Unarmoured control cable
43ii) Fixing of control cables in position with single compression nickel plated brass cable glands confirming to IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plates, etc. as required & including cost of cable glands, for each cable gland of size.
44(a) 19 mm unarmoured control cable
45(c) 25 mm unarmoured control cable
46(e) 32 mm unarmoured control cable
47iii) Termination of wires of cables with copper conductor using copper terminal ends (pin or ring type as required of Dowell's or equivalent make as approved by the Engineer - In - Charge) duly crimped with rimping tool, including making wire ends ready for crimping, ferruling &dressing of wires, etc., as required, including cost of terminal ends for all wires, for each cable at both ends for cables of the following sizes.
48a) 2.5 Sqmm for any number of core
49b) 4 Sqmm for any number of core
50L.T POWER CABLESI) Laying of P.V.C insulated and P.V.C shcathed armoured / unarmoured L.T Power cable of 11 KV grade with aluminium conductor as per IS 1255 in ground / cable trench / wall / surface including transportation of cable drums from site store to locations and excavation of 30cm x 75 cm size trenches. providing 25mm thick under layer of sand & 2nd class brick covering & refilling earth in remaining protion fixing as per apperoved / available spacing by means of M.S.U- clamps. etc as per specification as required including making necessary connection & esting etc as required of the following size. d) 31/2 core x 300 sqmm
51ii) Fixing of power cables in position with single compression, heavy duty nickel plated brass cable glands as per IS: 12943 & having three metal washers and one rubber ring, including preparation of cable and drilling of corresponding holes in gland plate, etc., including cost of cable gland if required, for each end of cable of size. g) 75 I 76 mm. for 3 Yo core x 300 sq. mm. cable with material
52iii)Termination of wires of cables with aluminium conductors using lSI marked tubular aluminium terminal ends as per IS: 8309 duly crimped with crimping tool, including making cable ends ready for crimping and providing insulation tape with colour code, dressing of wires,etc., including cost of terminal ends if required, for each end of cable (4 nos. per end) for the following size of cables. g) 3 Yo core x 300 sq. mm. cable with material
53FODP 96F indoor type reck mounted with FCPC Coupling and pigtails
5448 Fiber (DWSM) approach Cable
55Installation hardware set for above 48 Fiber optic approach cable
56Part-B NON BSR ItemP & F IP - 65/ IP - 66 protected non integral flood light luminaire suitable for Metal halide lamp comprising of powder coated die cast aluminium housing, electrochemically brightened and anodized aluminium reflector, covered with suitably gasketed heat resistant and toughened glass, porcelain holder, non integral cast aluminium control gear box having copper ballast, capacitor, electronic ignitor prewired with pvc insulated copper conductor up to terminal block including making connection testing etc. as required. (without lamp) (E 201200) Make Bajaj. Philips, Crompton, Havells P&F IP - 65 Luminaire For Metal Halide lamps (E201220)
571 X 250 Watt (E201221) Make Bajaj. Philips, Crompton, Havells
581 X 400 Watt (E201222) Make Bajaj. Philips, Crompton, Havells
59P & F Normal / High Output High pressure sodium vapour/ Metal halide / Halogen lamp as required. (E201300) Make Bajaj. Philips, Crompton, Havells Metal halide lamp single ended tubular (E201360)
60250 Watt (E201362) Make Bajaj. Philips, Crompton, Havells
61400 Watt (E201363) Make Bajaj. Philips, Crompton, Havells
62P & F 240 / 415 Volt MCB of breaking capacity not less then 10 KA (B/C/D Tripping characteristic) ISI Marked IS 8828 (1996) Confirming to IEC 60898 in existing board /sheets including making connections with lugs, testing etc. as required of Group 1 (E060100) single pole MCB (6A to 32 A rating ) (E 060112).
63P & F 240/415 V Isolators confirming to IS 13947-III/IEC 60947-3 on existing board/sheet including making connections with lugs, testing etc. as required of Group 1 (E060200) {Four pole Isolator, 30/40 Amps. rating} (E 060231)
64P & F Recessed/Surface mounting heavy duty horizontal type sheet steel distribution board phophatised/powder painted complete with copper bus bar, netural link, earth link and din bar confirming to IS 13032 & IS 8623 including making internal DB terminators with copper lugs, testing etc. as required of Group 1 (E060500)
65(single door single phase) 4 way (E 060511).
66(double door single phase) 4 way (E 060541).
67Providing & laying PVC insulated & PVC sheathed cable of 1.1 KV grade with aluminum conductor of IS : 1554 P-1 of group 2 of approved make in ground as per IS : 1255 including excavation of 30 cm X 75 cm size trench 25 mm thick under layer of sand, IInd class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size of Group 1
682X2.5 Sq. mm Armoured (E 110101A)
694X4.0 Sq. mm Armoured (E 110102 C)
70Add GST (18%) on Total Costruction Cost Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57749797
AUTHORITY Government Departments
TENDER VALUE 29.14 Lakhs
LAST DATE 12-10-2026
Authority
Authority Name Rajasthan Rajya Vidyut Prasaran Nigam Ltd
Work Description Tender for Construction Of 132Kv Gss Tehroli
Basic Detail
Tender No RVPN/SE/TNC/KOTA/2026/NIT-29
Bidding Type Tender
Location
City Kota
State Rajasthan
Key Dates
Publish Date 28 Sep 2026
Submission Date 12 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 29.14 Lakhs
Tender Fee 2950
EMD 58285
Exemption Available
Document List
0fa31689-4edf-4438-85d8-6377f93b94f9.html
BOQ_1065821.xls
TECHNICAL-DOCUMENT_compressed.pdf
Tendernotice_1 (79).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

0fa31689-4edf-4438-85d8-6377f93b94f9.html

xls

BOQ_1065821.xls

pdf

TECHNICAL-DOCUMENT_compressed.pdf

pdf

Tendernotice_1 (79).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders