Health and Family Welfare Government Departments Closing in 2 days TDR #57749515

Tender For Replacement Of Split Type Air Conditioners At Sub Registrar Office, 30 Bays Building Sector- 17, Chandigarh, Under maintenance Booth Sector 16 Chandigarh.

Issued by Government Departments · Chandigarh, Chandigarh
Tender Value
4.41 Lakhs
Estimated cost
Bid Submission
09 Oct 2026
2 days left
EMD
8824
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Replacement Of Split Type Air Conditioners At Sub Registrar Office, 30 Bays Building Sector- 17, Chandigarh, Under maintenance Booth Sector 16 Chandigarh.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 05-Oct-2026 tender postponement Date 09-Oct-2026

BOQ

Name of Work:- Replacement of Split Type Air Conditioners at Sub Registrar Office, 30 bays Building Sector- 17, Chandigarh, Under Mtc Booth Sector 16 Chandigarh.
Sl. No. Item Description
1Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall Split Type Air Conditioners, complete with Indoor unit (IDU), Out door unit (ODU), surface/concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section ) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU ) including drain pipe R-32/R-410/R-407 Green Refrigerant, wireless, Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll/rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42°C. Min 1 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS : 12615. Complete as per CPWD specification and IS: 1391 Part II 2023. The system shall be able to operate up to 50°C (out door ambient temperature).
2Inverter Type - Cooling Only
31.7 TR to 2.0 TR with 5 star Rating/Cooling Capacity 6000 Watt
4Manufacturing, Supplying and fixing of MS stand ( Powder Coated ) for Outdoor Unit of Split Type / Cassette Type Air Conditioner including grouting complete to the satisfaction of EIC.
5Providing and fixing of UPVC pipe of size 20mm Class 5 for condensate drain including cutting, jointing costing of solvent complete
6Providing and fixing of 22 Guage soft/ hard copper piping 3/8\\" & 5/8\\" or as per, OEM Specification. for liquid and sunction sides, between indoor & outdoor units with 6 mm thick nitrile rubber insulation & protective covering for exposed weather including cost of chasing brick wall/RCC wall & repairing to original condition. (The rate per metre includes cost of 1 metre each of both 3/8\\" & 5/8\\" with insulation and other works total line etc.)
7Providing and laying of Multicore flexible cable PVC Insulated with Bare Copper Conductor as per IS marked complete including making connection to the satisfaction of EICMake : Havells, Polycab, Finolex or as per approved make list
82.5 sqmm x 3 Core
9Providing and fixing of Voltage Stablizer suitable for 2.0 TR AC Unit 15 Ampere capacity working range 150 VAC to 285 VAC with low and high voltage cut off protection , built in thermal overload protection, digital / analog display for input / output voltage, wall mouted type, with metal cabinet complete of make V-Guard model VND 400 or equivalent model of Deol, Luminous, Microtech
105 KVA
11Supply installation Testing and Commissioning of surface mounted switch socket box including 3 pin top of rating 16Amp
12Cutting holes up to 30x30 cm in walls including making good the same:
13With common burnt clay F.P.S. (non modular) bricks
14Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof.
15Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57749515
AUTHORITY Government Departments
TENDER VALUE 4.41 Lakhs
LAST DATE 09-10-2026
Authority
Authority Name Public Health Department.
Work Description Tender for Replacement Of Split Type Air Conditioners At Sub Registrar Office, 30 Bays Building Sector- 17, Chandigarh, Under maintenance Booth Sector 16 Chandigarh.
Basic Detail
Tender No PH3/2026/437
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 05 Oct 2026
Submission Date 09 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value 4.41 Lakhs
Tender Fee Ref. Documents
EMD 8824
Exemption Not Available
Document List
6e8a6783-b1e4-4b3d-b617-e3824793d543.html
BOQ_117685.xls
Tendernotice_1 (34).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 09, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 2 days
Oct 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

6e8a6783-b1e4-4b3d-b617-e3824793d543.html

xls

BOQ_117685.xls

pdf

Tendernotice_1 (34).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders