Housing Urban and Rular Development Local Bodies Closing in 4 days TDR #57749104

Tender For Supply And Erection Of 25 Watt, 72 Watt Led Street Lights And 150 Watt Flood Lights On Existing Lt Line Poles In Sector 9, Jind. (Including 5 Years Defect Liability Period Including Mtc., On/Off Operation Of Led Lights As Well As 3 Years D

Issued by Local Bodies · Jind, Haryana
Tender Value
1.43 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
4 days left
EMD
2860
Bank guarantee accepted
Document Fee
250
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jind → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply And Erection Of 25 Watt, 72 Watt Led Street Lights And 150 Watt Flood Lights On Existing Lt Line Poles In Sector 9, Jind. (Including 5 Years Defect Liability Period Including Mtc., On/Off Operation Of Led Lights As Well As 3 Years Defect Liability Period For All Other Items Free Of Cost) Rates Taken In Dnit Are Excluding Gst.)A/Cost Rs. 1.43 Lacs E/Money Rs.2860/- Time Limit : One Month

BOQ

Name of Work:- Supply and erection of 25 Watt, 72 Watt LED Street Lights and 150 Watt Flood Lights on existing LT Line poles in Sector 9, Jind. (Including 5 years defect liability period including mtc., ON/OFF operation of LED lights as well as 3 years defect liability period for all other items free of cost) Rates taken in DNIT are excluding GST.)A/Cost Rs. 1.43 Lacs E/Money Rs.2860/- Time Limit : One Month
Sl. No. Item Description
123.28.13.7Supplying, installation, Testing and Commissioning of 25 Watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
223.28.13.13Supplying, installation, Testing and Commissioning of 72 Watt Street light LED fixture powder coated pressure die cast aluminum body with driver as per the requirement with Driver efficiency )85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP- 66,IK-10, CRI )80, under voltage and over voltage protection, EMI- EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy =120 (135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
323.28.17.4Supplying, installation, Testing and Commissioning of 150 Watt Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency )85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency )85%,THD ( 10% as per IEC 61000-3-2 , P. F.=0.95, IP-66,IK-10, CRI )80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg- 120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver and electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) (5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy )135 lm/Watt output . LM79 and LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).
4Job WorkSupply and erection of PVC flexible aluminium wire of size 2.50 sqmm single core complete in all respect as per standard specification upto the entire sartisfaction of Engineer-in-charge. (Excluding GST)
5Job WorkSupply and erection of bracket 1 mtr. long made of 32mm dia (Nominal), medium gauge G.I. pipe for fixing of Stret Light fitting on 9 mtr. long PCC Poles including cost of 6 Nos. G.I. Nut and Bolts with two nos. clamps made of 50x60mm G.I. flat complete in all respect upto the entire satisfaction of the Engineer-in-Charge. (Excluding GST). Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57749104
AUTHORITY Local Bodies
TENDER VALUE 1.43 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Haryana Urban Development Authority
Work Description Tender for Supply And Erection Of 25 Watt, 72 Watt Led Street Lights And 150 Watt Flood Lights On Existing Lt Line Poles In Sector 9, Jind. (Including 5 Years Defect Liability Period Including Mtc., On/Off Operation Of Led Lights As Well As 3 Years Defect Liability Period For All Other Items Free Of Cost) Rates Taken In Dnit Are Excluding Gst.)A/Cost Rs. 1.43 Lacs E/Money Rs.2860/- Time Limit : One Month
Basic Detail
Tender No Job No. 49.26 (R)
Bidding Type Tender
Location
City Jind
State Haryana
Key Dates
Publish Date 28 Sep 2026
Submission Date 05 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 1.43 Lakhs
Tender Fee 250
EMD 2860
Exemption Available
Document List
3e6a2171-888f-4179-8417-027c02062f86.html
BOQ_630480.xls
Tendernotice_1 (22).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

3e6a2171-888f-4179-8417-027c02062f86.html

xls

BOQ_630480.xls

pdf

Tendernotice_1 (22).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders