Tender For Fixing Of Flood Lights And Taking Down Installed Lights At Badminton Court Of Ntbc, Newtown, Kolkata
Tender Value
10.20 Lakhs
Estimated cost
Bid Submission
12 Oct 2026
7 days left
EMD
20406
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Fixing Of Flood Lights And Taking Down Installed Lights At Badminton Court Of Ntbc, Newtown, Kolkata
BOQ
| Sl. No. | Item Description |
| 1 | Removing of luminaries with lamp from the pole /column and keeping them ready for dispatch as per the direction of EIC : HPMV/HPSV limunaries/MH/LED Street light fittings. |
| 2 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.: For other structural works like galleries etc |
| 3 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) : Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m) |
| 4 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). : 6 way (4 + 18), Double door |
| 5 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. : 63 A |
| 6 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. : Single pole |
| 7 | Multi core PVC insulated flexible wire copper 3 core 2.5 sqmm. |
| 8 | XLPE Armoured aluminium cable :4 core 10 Sqmm. Make : Havells/Polycab/Gloster/MESCAB |
| 9 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 10 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. : 4 X 10 sq. mm (25mm) |
| 11 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. : 63 A |
| 12 | Supply of high-quality integrated LED Flood Light with a minimum system lumen of 27000 Lm with elliptical Beam angle and system wattage not exceeding 195W with a nominal efficiency 135 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI : 70. The housing should be of non-corrosive high-pressure single piece die-cast aluminum to with stand extreme environments. I should have PF> 0.95. Lifetime of 50K hours @L70 at 35deg C ambient temperature. The Ingress protection should be minimum IP 66 with an IK rating of 08. Optical and control gear compartments shall be maintainable/ replaceable without impacting the LED units. The access to the optical and the gear compartment should be separate. While accessing the gear compartment, the optical compartment should not be accessible. The Luminaire should have a 10KV SPD duly bolted in the Luminaire and 4KV internal surge protection and rane of operating voltage will be 120-277V AC. The Luminaire should have a breather to ensure that air balance inside and outside of the Compartment The luminaire should be of Class B Serviceability. The wattage of each LED should be greater than 1 watt and less than 4 Watt. Only high power Single white LED chip with ceramic based suitable for outdoor use is allowed. Multi Chip , array multi die , mid power ,Integrated arrays and COB’s are not permitted. The LED used in the luminaire shall be SMD type only of make LGIT, Lumileds, Osram, Nichia, and CREE & no other make. The luminaire should be capable of withstanding voltage stress of 440V for 8 Hrs., should have an auto shutdown @ 325V and have an auto recovery feature. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire & it should be of same make. The Dimension of the luminaires should be minimum 538 x 62 x243 mm and have a breather ensuring a stable optical and thermal management. The weight of the luminaire should not be more than 7 Kg. It should have class I Electrical insulation and Class B serviceability. Both luminaire and driver should be of same make and both of them should have BIS approval. Similar to Philips BVP483 or equivalent |
| 13 | Fixing only Floodlight Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure |
| 14 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 15 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 16 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender