Tender For Electrical Installation Work For Installation Of 06 Nos. Of Commercial Type Washing Machine With Dryer Inside Balurghat Central Correctional Home.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
06 Oct 2026
7 days left
EMD
5993
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dinajpur Dakshin → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Electrical Installation Work For Installation Of 06 Nos. Of Commercial Type Washing Machine With Dryer Inside Balurghat Central Correctional Home.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying and fixing of following ways surface/ recess mounting, Vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required. up to 160A (Make-Legrand/Seimens/ABB/Havells/Crabtree/Hager) |
| 2 | i) 4 way Double door |
| 3 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). (Make-Legrand/Seimens/ABB/Havells/Crabtree/Hager) |
| 4 | ii) 4 way (4 + 12), Double door |
| 5 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. (Make-Legrand/Seimens/Schneider/L&T/ABB/Havells/Crabtree/Hager) |
| 6 | ii) 125 A, 16 KA,TPMCCB |
| 7 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing andcommissioning etc. as required. (Make Legrand/Seimens/ABB/Havells/Crabtree/Hager) |
| 8 | i) Single pole |
| 9 | ii) Triple pole-63A |
| 10 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-Legrand/Seimens/Schneider/L&T/ABB/Havells/Crabtree/Hager) |
| 11 | i) 63 A- FP |
| 12 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-ABB/Havells/Crabtree/Hager) |
| 13 | i)40 A- DP |
| 14 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. [Make: KEI/Polycab/Havells/RR/Glowstar] |
| 15 | iii) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 16 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Make: KEI/Polycab/Havells/RR/Glowstar] |
| 17 | a) 4 core X 16 sq.mm(From F/P to TPN) |
| 18 | b) 4 core X 35 sq.mm(From F/P to VTPN) |
| 19 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required : |
| 20 | a)4 X 16 sq. mm (28mm) |
| 21 | b) 4 X 35 sq. mm (32mm)(From F/P to VTPN) |
| 22 | Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. i)Upto 35 sq. mm |
| 23 | Supplying and fixing MCB SS enclosure with IP-20/30protection, powder coated provision for two/four poleMCB, concealed in wall after cutting the wall & mendinggood the damages to original finish incl. painting,connection & provision for earthing attachment (Make-ABB/Havells/Crabtree/Hager) |
| 24 | i) 2 Way |
| 25 | Supplying and fixing following rating, double pole, 240V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make-ABB/Havells/Crabtree/Hager) |
| 26 | i) 40A DP MCB |
| 27 | Supplying and fixing 415V 125A, TPN SFU with Angle iron frame enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T) For VTPN DB (Make-ABB/Havells/Crabtree/Hager) |
| 28 | Supplying and fixing 415V 63A, TPN SFU with Angle iron frame enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make- L&T) For TPN DB (Make-ABB/Havells/Crabtree/Hager) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 08, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer