Rural Development Local Bodies Closing in 16 days TDR #57745973

Tender For Construction Of Community Centre/Mini-Sports Complex/Multipurpose Building In Sector-06 Ward No. 26 Mc Panipat.

Issued by Local Bodies · Panipat, Haryana
Tender Value
12.51 Crore
Estimated cost
Bid Submission
19 Oct 2026
16 days left
EMD
25.03 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panipat → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Community Centre/Mini-Sports Complex/Multipurpose Building In Sector-06 Ward No. 26 Mc Panipat.

BOQ

Name of Work:- Construction of Community Centre/Mini-Sports Complex/Multipurpose Building in Sector-06 Ward No. 26 MC Panipat.
Sl. No. Item Description
1NS ITEMS
2Providing and fixing of COMMUNITY CENTRE PANIPAT in Acrylic Letters with light of 24` Height with power Supply and Warrenty of 2 years with fittings complete with all respect. (Acrylic Make: Astari, Marga cipta, Acast),...( Make: Hilight, Osram , GOQ)....( Make: Timex, Alutech , Aluceor or equivalent)
3Providing and fixing of signages of toilet of size 300x450mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work.. (Make: Patel Brothers , JMJ Signage , Vizan Sign or equivalent)
4Providing and fixing of signages of fire exit names of size 800x300mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work.(Make: Patel Brothers , JMJ Signage , Vizan Sign or equivalent)
5Providing and fixing of signages of drinking water / lift names of size 300x300mm as per design complete in all respect up to the entire satisfaction of Engineer-in-charge of the work.(Make: Patel Brothers , JMJ Signage , Vizan Sign or equivalent)
6Credit of old bricks with transportation and cartridge as per the drawing and complete in all respect as per the direction of engineer in charge.
7Providing and fixing of approved coloured verticle type hot water 25 ltr geysers. The inner container shall be made of copper sleeve with PUF insulation between inner and outer container, element pipe and heating element, pressure cum vaccume release, thermostat and thermal cutout arrangements and fusible plug. The outer container shall be of powder coated finish with all other accessories including fixing brackets complete as required.
8Providing and fixing of 6mm Toughened glass comply with the requirement of BS EN 572 parts 1,2 and3 or ASTM C1036 assessed for optical and visual faults as described in BS EN 572-2. Spot faults to be no worsethan category C. There will be no linear /extended faults. Optical faults to be within the limits set in BS EN 572-2 of model no. ET 150 Toughened glass complete in all respect up to the entire satisfaction of Engineer-in-charge of the work. (Make: Relaxo , Modiguard, Saintgobain or equivalent)
9Providing and Fixing of Decorative pole of 5mtr high made of galvanised Mild steel pipes fitted with cast aluminium embellishments duly polyurethane paint coated with cast aluminium base cover. Pole Bottom Dia- 139.7x3.6mm (1 mtr), Top Dia -_ 76.1x3.2mm (2.5 mtr) Base Plate Size is 250x250x12mm Foundation Bolt 16x600x4 Nos. with Single Arm Bracket MF-82A height will be 1.5 Mtr. Long with Suitable pipes and Bracket will be completed with Aluminium Castings as per approved design and LED decorative drop down light 50w made of aluminium housing fitted with PMMA diffuser, Light Dimensions is 500x370 (With-Philips/Fulhame/HR Driver and10KVA SPD)complete in all respect as per the direction of the officer-in-charge.
10Design, manufacture supply, installation, testing and commissioning of the following extensible cubicle type indoor mounting, dead front, fully compartmentalised with hinged lockable detachable front and back openable, dust and vermin proof, floor mounting sheet steel clad switchboard fabricated out of 2 mm thick CRCA powder coated sheet steel suitable for use at 415 volts 3 phase 4 wire 50 cycle system and to withstand a symmetrical fault level as specified at 415 volts. Panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition. All incomer breaker and Bus Couplers shall be interlocked electrically as shown in SLD and specifications. Note: The following provisions shall be required to be made in the switchboard as detailed below:a) The Switchboards shall have provision to accommodate all cables from the bottom /top as required.b) All live accessible parts shall be shrouded with 1mm thick polycarbonate/3 mm thick FRP sheet and all equipment shall be finger touch proof. The busbar insulation shall be with heat shrinkable sleeves according to the colour code. SMC shrouds and busbar supports shall be used. c) Galvanised hardware with zinc passivation shall be used in fabrication of Switchboards. d) All rear door of Main LT Panel shall be Almirah type with lockable arrangement.e) Space heater shall be provided with thermostat with 6A MCB as backup protection in each section of Main LT Panel and controlled with 20 A DP MCB, 10 KA.f) Provision of one 6/16 amp socket and compartment lighting for each vertical section of main LT Panel.g) The panel shall display Main Incomers Bus Couplers of Main LT Panel. This line diagram shall be made from luminous non fading materials to glow in dark and each breaker legend shall be provided with bi-colour LED lights to show the Phase indication Lamp and ON/OFF status of the respective feeder (Incomers / Bus couplers)h) All control and power wiring shall be broughtout upto the cable alley in the terminal blocks. 10% extra terminals shall be supplied along with Panel.i) An approval shall be taken for each panel before manufacturing.j) Suitable Aluminium earth bus to be provided throughout the length of Switchboards.k) All indication lamps / illuminated push buttons shall be LED type.l) 2A SP MCBs shall be used as backup protections.m) Coil of all motor starters shall be fed from 440 V / 230 V Control Transformer.n) All incomer meters of Main LT Panel shall be multifunction and should have all the electrical parameters like, Voltage, Ampere, KW, KVAR, KWH, PF, Frequency etc. with communication port RS-485.o) All feeders with KWHr meter will be Electronic Dual Reading KWHr meter alongwith appropriate CT`s and 1 sq. mm control wiring from each KWHr meter for RS-485 communication till DCU`s compartment.p) Provision for providing 230V AC supply for Dual KWHr metering when any or all DG are in operation q) One separate compartment of minimum size 400 x 900 mm for power management system of D.C.U.`s with control wiring as per following specification and control wiring scheme. Control wiring shall be looped from each energy meter till DCU`s compartment for sending DCU register change command from data connectivity.r) All CT and PT`s shall be cast resin type. Class - 3 CT shall be provided up to 100 amp and above that the CT shall be Class - 1.s) Zone selective Interlocking to be hardwired between incoming and outgoing ACB of main LT Panel.t) All incomer ACBs of Main LT Panel shall be with microprocessor based releases (O/C, S/C and E/F), display of current/voltage and communication port RS-485, however ACB Incomers in other distribution panel and outgoing of Main LT Panel shall be with standard releases.( Ics=100%Icu=Icw )u) All Main LT Panel outgoing ACB shall be with inbuilt earth fault release with CT and MCCB shall be with earth fault module with associated neutral CT for feeder protection, for TP feeders and E/F release for FP feeders.v) All MCCB shall be provided with Rotary handle, door interlocked and lockable in off position of MCCB.w) All Main LT Panel outgoing MCCBs shall be with microprocessor based releases, line load reversibility, Ics = 100% Icu. x) Rating of Neutral bus-bar shall be 50% of phase-bus bary) All MCB to be C Curve typez) Micro PLC for auto load management and interlocking as per logic specified.MAIN LT PANEL (INBUILT CAPACITOR PANEL) (Make AAA Switchgear, Indiatech panel, Neptune india)i) 400 amps 25 kA 100 volt FP MCCB with overcurrent and short circuit and earth fault module, with heavy duty solid detachable neutral link Metering for incoming: a) 3 nos 400/5A Class 1, 15 VA Burden CT`s for metering and 1 nos associated Neutral CT for earth fault module. b) Digital flush type class -1.0 accuracy multifunction meter with RS-485 communication port for measurement of THD, KVARH KW, KWH, KVAR, PF, V, A, Hz, equivalent to EM6400 NG, with 3 Nos. current transformers of required ratio, 15 VA Cl
11FEEDER PILLAR - IP55 (Make AAA Switchgear, Indiatech panel, Neptune india)Incoming:1 Nos. 100 Amp FP MCCB OF 25 KA Breaking CapacityPhase indication Lamp and ON/OFF indicating lamps with MCB as backup protection.Bus Bar:TPN Aluminium busbars aluminium three phase and neutral busbars rated at 125 amps, 25 KA, insulated with heat shrinkable coloured PVC sleeves and clip on shrouds for joints. Current density of Bus Bar to be 1.0 sq.mm / amp.Outgoing :5 nos. 63 amps 25 kA FP MCB 5 nos. 63 amps 25 kA DP MCB Complete Set as required above
12Supplying Installation, Testing and Commissioning ofLED RGB/RGBWW/ RGBNW/ RGBA/RGBW suitablefor exterior use having IP68 rating (as per siterequirement). Flexible light strip of 5 mtr standardlength with 12-15 Watt per meter. Luminaire shall becapable of producing dynamic colour changing light forwith 16 million colours by DMX/Ethernet based control.Minimum System lumens 450 lumens/meter andSystem Lumen Efficacy ) 30lm/w. Luminaire lightbeam spread - 100-110°, The Strip should have IP 68protection and is offered IP 68 rated connectors to jointhe LED Strips in continuity. The luminaire must beoffered with Aluminium channel for mounting the striplights. The product should be complete with allaccessories and Driver. Lifetime of completeluminaire (LED, Driver, Electrical and control circuitry) `shall be at least L70:50000 burning hours at 50°C.Luminaire shall be conforming to BIS (IS 10322) withdully R Number marked. Luminaire shall be completewith replaceable driver and capable of operating at linevoltage without any separate power supply from 24 VDC, Fixture shall be suitable to operate at an ambienttemperature range of -10°C to plus 50°C. The successfulbidder shall submit the following certifications/reportsfor approval before supply of materials: product datasheets, LM79.report from NABL accredited lab, illuminance diagram,polar curve and LM80 report issued by LEDmanufacturer and RoHS Compliance along with CEcertificate.`
13Supplying Installation, Testing and Commissioning ofLED RGB/RGBWW/ RGBNW/ RGBA/RGBW suitablefor exterior use having IP68 rating (as per siterequirement). Flexible light strip of 5 mtr standardlength with 12-15 Watt per meter. Luminaire shall becapable of producing dynamic colour changing light forwith 16 million colours by DMX/Ethernet based control.Minimum System lumens 450 lumens/meter andSystem Lumen Efficacy ) 30lm/w. Luminaire lightbeam spread - 100-110°, The Strip should have IP 68protection and is offered IP 68 rated connectors to jointhe LED Strips in continuity. The luminaire must beoffered with Aluminium channel for mounting the striplights. The product should be complete with allaccessories and Driver. Lifetime of completeluminaire (LED, Driver, Electrical and control circuitry) `shall be at least L70:50000 burning hours at 50°C.Luminaire shall be conforming to BIS (IS 10322) withdully R Number marked. Luminaire shall be completewith replaceable driver and capable of operating at linevoltage without any separate power supply from 24 VDC, Fixture shall be suitable to operate at an ambienttemperature range of -10°C to plus 50°C. The successfulbidder shall submit the following certifications/reportsfor approval before supply of materials: product datasheets, LM79.report from NABL accredited lab, illuminance diagram,polar curve and LM80 report issued by LEDmanufacturer and RoHS Compliance along with CEcertificate.`
14HSR ITEMS
15ALL HSR ITEMS Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57745973
AUTHORITY Local Bodies
TENDER VALUE 12.51 Crore
LAST DATE 19-10-2026
Authority
Authority Name Urban Local Bodies
Work Description Tender for Construction Of Community Centre/Mini-Sports Complex/Multipurpose Building In Sector-06 Ward No. 26 Mc Panipat.
Basic Detail
Tender No 2026955B1C42 3C52 4D18 99D1 8A82D8865009286ULB
Bidding Type Tender
Location
City Panipat
State Haryana
Key Dates
Publish Date 28 Sep 2026
Submission Date 19 Oct 2026
Open Date 19 Oct 2026
Finance
Tender Value 12.51 Crore
Tender Fee 20000
EMD 25.03 Lakhs
Exemption Available
Document List
8a95c596-1285-496b-a775-db526448768a.html
BOQ_630545.xls
Tendernotice_1 (22).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 28, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Oct 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 16 days

Tender Documents

Download All (ZIP) ↓
html

8a95c596-1285-496b-a775-db526448768a.html

xls

BOQ_630545.xls

pdf

Tendernotice_1 (22).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders