Tender for Provn Of Station Store (100 Sqm) Alongwith Air-Conditioning Facility For Hq Arty Bde At Alwar Mil Stn.
BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing n exc 15 cm deep and getting out in any kind of soil, complete all as specified and directed. |
| 2 | Excavation in trenches n exc 1.50 m wide and n exc 1.50 m deep for foundations or for shafts, wells, cesspits, manholes, pier holes and the like, n exc 10 Sqm on plan, and getting out in soft/loose soil, complete all as specified and directed. |
| 3 | M&L for PCC 1:4:8, Type D-2, using 40 mm graded stone aggregate, as in foundations, filling and mass concrete, complete all as specified and directed. |
| 4 | M&L for brickwork with fly ash bricks conforming to IS 13757, old size, straight or curved on plan exc 6 m mean radius, built in CM 1:6, complete all as specified and directed. |
| 5 | M&L for RCC M-25 grade (design mix) using 20 mm graded stone aggregate in foundations including rafts, footings, foundation beams, plinth beams, bases for columns, under-reamed piles and mass concrete, complete all as specified and directed. |
| 6 | M&L for RCC M-25 grade (design mix) using 20 mm graded stone aggregate in columns, pillars, piers, posts, struts and the like, complete all as specified and directed. |
| 7 | M&L for RCC M-25 grade (design mix) using 20 mm graded stone aggregate in lintels n exc 1.50 m clear span, chajjas, seismic bands, lintel bands, roof bands and the like, complete all as specified and directed. |
| 8 | M&L for RCC M-25 grade (design mix) using 20 mm graded stone aggregate in slabs supported on walls, beams and columns, as in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like, complete all as specified and directed. |
| 9 | M&L for use and waste of rough-finished formwork to sides of concrete foundations, footings, bases of columns, rafts and raft beams, sides and soffits, if any, of foundation and plinth beams and similar work, vertical or to batter, complete all as specified and directed. |
| 10 | M&L for use and waste of rough-finished formwork to sides of pillars, posts, struts, piers, columns and stanchions, square, rectangular or polygonal, complete all as specified and directed. |
| 11 | M&L for use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers and shelves including supports, overhangs and splays between floors and beams, for fair-finished flat surfaces of concrete, complete all as specified and directed. |
| 12 | M&L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, n exc 200 mm thick, horizontal or sloping, for fair-finished flat surfaces of concrete, complete all as specified and directed. |
| 13 | M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floors and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work, exc 10 cm but n exc 20 cm wide, for rough-finished surfaces, complete all as specified and directed. |
| 14 | M&L for TMT steel reinforcement bars, 10 mm dia and over, cut to required lengths and bent to shape including cranking, bending spirally for hooping of columns, hooking ends and binding with and including annealed mild steel binding wire not less than 0.90 mm dia or securing with clips, complete all as specified and directed. |
| 15 | All as per preceding item but TMT steel reinforcement bars 5 mm dia and over up to and including 10 mm dia, as in stirrups, spacers and binders, complete all as specified and directed. |
| 16 | M&L for 10 mm thick rendering in CM 1:6 on fair faces of brick/block masonry or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 17 | M&L for 5 mm thick rendering in CM 1:3 on ceiling surfaces, finished even and smooth without using extra cement, complete all as specified and directed. |
| 18 | M&L for 15 mm thick rendering in CM 1:4 on surfaces other than fair faces of brick/block masonry or concrete surfaces, finished even and smooth without using extra cement and mixed with integral waterproofing compound @ 3% by weight of cement, complete all as specified and directed. Note: Waterproofing compound shall be measured and paid for separately. |
| 19 | M&L for 10 mm thick rendering in CM 1:4 on concrete roof surfaces, finished even and smooth without using extra cement and mixed with integral waterproofing compound @ 3% by weight of cement, complete all as specified and directed. Note: Waterproofing compound shall be measured and paid for separately. |
| 20 | Supply only integral waterproofing compound of approved make and quality, suitable for mixing with cement mortar/concrete, complete all as specified and directed. |
| 21 | M&L for waterproofing treatment to RCC roof slab including parapets, comprising preparation of surfaces; applying bituminous primer @ 0.40 litre/Sqm; laying one layer of 3 mm thick APP-based polymeric membrane of approved manufacturer weighing not less than 3.60 Kg/Sqm by torch application over bitumen 85/25 @ 1.20 Kg/Sqm, with side laps of 75 mm and end laps of 100 mm; carrying membrane up parapets to a height not less than 200 mm and inserting the same into groove; finishing with membrane flashing and applying two coats of heat-resistant roof paint, complete all as per manufacturer's instructions and as specified and directed. |
| 22 | S&F powder-coated aluminium sliding window comprising three-track outer frame of section 92 x 31.75 x 1.10 mm; two glazed sliding shutters of section 44 x 18 x 1.25 mm fitted with 4 mm thick heat-absorbing glass, suitable EPDM beading and locking arrangement; and one gauze sliding shutter of section 44 x 18 x 1.25 mm fitted with stainless-steel wire cloth of 0.36 mm nominal wire dia and average aperture 1.40 mm, including SS screws, rollers, locking arrangement and all necessary fittings and accessories, fixed complete all as specified and directed. Note: Measurement shall be on overall outer size of window. |
| 23 | S&F powder-coated aluminium glazed door of approved colour comprising frame section 63.5 x 38.10 x 2.00 mm and shutter sections comprising 45 x 45 x 2.00 mm vertical stiles and 110 x 45 x 2.00 mm top, bottom and middle rails, fitted with 4.8 mm thick frosted glass including glazing clips, PVC track gasket, EPDM rubber gasket, recessed-type handles, hinges, mortice lock, door closer and all necessary fittings and accessories, fixed complete all as specified and directed. |
| 24 | M&L for returning, filling in, spreading, levelling, watering and well ramming excavated earth in layers n exc 25 cm thick, in any kind of soil, complete all as specified and directed. |
| 25 | Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.50 m above the starting point, complete all as specified and directed. |
| 26 | M&L for earth filling under floors including spreading, levelling, watering and well ramming in layers n exc 25 cm thick, complete all as specified and directed. |
| 27 | M&L for hardcore of broken stone or boulders, gauge n exc 63 mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and well rammed to a true and even surface, complete all as specified and directed. |
| 28 | M&L for 75 mm thick PCC 1:4:8, Type D-2, using 40 mm graded stone aggregate, as in sub-base of floors, pavings, paths and the like, complete all as specified and directed. |
| 29 | M&L for machine-cut Kota stone slab flooring, 20 to 25 mm thick, laid over 20 mm thick screed/bedding in CM 1:4, set and jointed with grey cement slurry mixed with pigment to match shade of stone, including rubbing and polishing and taking up existing old stone slab flooring, complete all as specified and directed. |
| 30 | All as per preceding Kota stone item but as in skirting, dado and other vertical surfaces, laid over 10 mm thick rendering in CM 1:4, set and jointed in neat cement slurry and pointed in white/coloured cement to match shade of stone, including taking down existing old stone slab, complete all as specified and directed. |
| 31 | M&L for suspended false ceiling comprising 6 mm thick 'E' board ceiling tiles, Classic/Designer pattern as approved by GE, size 595 x 595 mm, fixed over and including powder-coated galvanized iron grid system of 600 x 600 mm modules comprising main tees 39 x 24 mm, cross tees 29 x 34 mm and wall angles 22.20 x 22.20 mm, suspended from ceiling with 4 mm dia galvanized wire, butterfly clips, wall-tapping screws, hold-down clips and all necessary accessories, complete all as per manufacturer's instructions and as specified and directed. |
| 32 | M&L for 75 mm thick PCC 1:3:6, Type C-1, using 20 mm graded stone aggregate, as in plinth protection, finished even and smooth without using extra cement, with 10 mm wide joints for full depth at corners and at 3 m centres filled with mastic mortar, complete all as specified and directed. |
| 33 | M&L for preparation of new plastered wall surfaces and applying two coats of premium water-based smooth exterior acrylic emulsion paint of approved colour with silicon additive, colour-stay technology, dirt-pick-up resistance, anti-algal properties and VOC less than 50 g/litre, complying with LEED requirements, applied @ 1.79 litre undiluted/10 Sqm or as per manufacturer's instructions over priming coat and over and including waterproof/weatherproof cement-based putty @ 1 Kg/Sqm for average 1 mm thickness, applied by fully automatic airless spray equipment of minimum flow 1 litre/minute at 3300 PSI, including necessary scaffolding at any height, complete all as specified and directed. |
| 34 | M&L for preparing newly plastered ceiling surfaces and applying three coats of whitewash, complete all as specified and directed. |
| 35 | M&L for preparation of new plastered wall surfaces and applying two coats of smooth interior acrylic emulsion paint with rich matt finish, VOC less than 50 g/litre and complying with LEED requirements, applied @ 1 litre undiluted/10 Sqm, diluted with water in 2:1 ratio or as per manufacturer's instructions, over priming coat and over and including waterproof/weatherproof cement-based putty @ 1 Kg/Sqm for average 1 mm thickness, applied by fully automatic airless spray equipment of minimum flow 1 litre/minute at 3300 PSI, complete all as specified and directed. |
| 36 | M&L for anti-termite treatment to backfill in contact with foundations by applying chemical emulsion @ 7.50 litres/Sqm of vertical surface of substructure in contact with backfill, complete all as specified and directed. |
| 37 | M&L for anti-termite treatment to top surface of filled earth by applying chemical emulsion @ 5 litres/Sqm of surface, complete all as specified and directed. |
| 38 | M&L for factory-made machine-pressed precast concrete interlocking paver blocks, coloured/glossy finished, of any approved shape and size, 60 mm thick, M-30 grade, conforming to IS 15658, laid over and including 25 mm thick sand cushion, properly aligned, levelled and compacted, complete all as specified and directed. |
| 39 | M&L for providing and laying at or near ground level factory-made M-25 grade precast cement concrete kerb stones to required line, level and curvature, jointed in CM 1:3, including making joints with or without grooves, joints except at sharp curves n exc 5 mm thick, and forming drainage openings wherever required, complete all as specified and directed. |
| 40 | M&L for concealed point wiring complete with 1.5 Sqmm single-core multistranded copper conductor FRLSH PVC insulated and unsheathed cable, 1100 Volts grade, conforming to IS 694, drawn through and including heavy-duty rigid non-metallic PVC conduit, minimum 20 mm external dia or increased as required in accordance with Clause 19.125 of MES SSR Part-I, ISI marked and having wall thickness not less than 1.8 mm, including bends, tees, junction boxes and other conduit accessories, fixed concealed/recessed in walls/ceilings, including 1.5 Sqmm single-core FRLSH PVC insulated unsheathed multistranded copper conductor as continuous earth wire, sunken type electroplated pressed-steel terminal box of suitable size with 3 mm thick white/coloured Bakelite top cover, for one light point controlled by one one-way switch, including cutting chases in stone/brick walls and making good disturbed surfaces to match existing, complete all as specified and directed. |
| 41 | All as per preceding item but for one 3-pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on the same board, complete all as specified and directed. |
| 42 | All as per preceding item but for one 3-pin 5/6 Amp socket outlet controlled by one 5/6 Amp switch on independent board, complete all as specified and directed. |
| 43 | All as per preceding point wiring item but for one 3-pin 15/16 Amp socket outlet controlled by one 15/16 Amp switch on independent board, wired with 2.5 Sqmm single-core multistranded copper conductor FRLSH PVC insulated and unsheathed cable, 1100 Volts grade, including 2.5 Sqmm single-core FRLSH PVC insulated and unsheathed multistranded copper conductor as continuous earth wire in green colour, complete all as specified and directed. |
| 44 | S&F piano type flush-mounted single-pole one-way switch, 5/6 Amp, 230 Volts, complete all as specified and directed. |
| 45 | S&F piano type flush-mounted single-pole one-way switch, 15/16 Amp, 230 Volts, complete all as specified and directed. |
| 46 | S&F flush-mounted 3-pin socket outlet with 2-pin outlet facility, 5/6 Amp, 240 Volts, complete all as specified and directed. |
| 47 | S&F flush-mounted 2-in-1, 3-pin socket outlet, 5/15 Amp, 240 Volts, complete all as specified and directed. |
| 48 | S&F surface-mounted Bakelite ceiling rose, 65 x 50 mm, with two/three terminals, complete all as specified and directed. |
| 49 | S&F 1.20 m long LED batten comprising CRCA sheet housing with glossy polycarbonate diffuser, duly pre-wired, having nominal system lumen output 2000 lumens, minimum system efficacy 115 lumen/Watt and total power consumption n exc 20 Watt, complete with integral electronic LED driver, rated system life 40,000 burning hours at L70, CCT 6500K, CRI >80, THD <10% and PF >0.95, including necessary fixing accessories and electrical connections, complete all as specified and directed. Make: Crompton/Philips/Havells or other approved make as specified in CA. |
| 50 | S&F 35 Watt LED street-light fitting, 230 Volts AC, outdoor type, comprising high-pressure die-cast aluminium housing with efficient thermal management arrangement, suitable optical system and integral electronic LED driver, complete with lamp bracket and impact/corrosion-resistant components, IP66 protection, including necessary fixing accessories and electrical connections, complete all as specified and directed. Make: Philips/Havells/Crompton or other approved make as specified in CA. |
| 51 | S&F triple-pole and neutral MCB, 16–32 Amp, 10 kA breaking capacity, C-curve, suitable for 415 Volts AC system, including necessary connections, complete all as specified and directed. |
| 52 | S&F single-pole MCB, 6–40 Amp, 10 kA breaking capacity, B-curve, 240 Volts AC, including necessary connections, complete all as specified and directed. |
| 53 | S&F 4-way TPN vertical sheet-metal distribution board, double-door type, 415 Volts, suitable for fixing MCBs, complete with 200 Amp rated TPN busbar and inbuilt 4-pole 63 Amp, 16 kA MCCB as incomer, including internal connections, neutral link, earth bar, necessary fixing accessories, incoming/outgoing connections, testing and commissioning, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 54 | S&F 4-way TPN vertical sheet-metal distribution board, double-door type, 415 Volts, suitable for fixing MCBs, complete with 200 Amp rated TPN busbar and inbuilt 4-pole 63 Amp, 16 kA MCCB as incomer, including internal connections, neutral link, earth bar, necessary fixing accessories, incoming/outgoing connections, testing and commissioning, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysOct 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender