Housing Urban and Rular Development Local Bodies Closing in 5 days TDR #57740127

Tender For maintenance of Various Scheme Under Na -Ii/Ez.Repair And Maintenance Of Rain Water Harvesting System At Dda Staff Club Mayur Vihar Phase-I.

Issued by Local Bodies · Delhi, Delhi
Tender Value
15 Lakhs
Estimated cost
Bid Submission
05 Oct 2026
5 days left
EMD
30010
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for maintenance of Various Scheme Under Na -Ii/Ez.Repair And Maintenance Of Rain Water Harvesting System At Dda Staff Club Mayur Vihar Phase-I.

BOQ

Name of Work:- M/o various scheme under NA –II/EZ.Repair and maintenance of rain water harvesting system at DDA Staff Club Mayur Vihar Phase-I.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic Excavator/ Manual means over areas (excedding 30 cm in depth. 1.5 m in width as well as 10 sqm on plan) Including disposal of excavated earth, lead upto 50m and for all lift as directed by engineer-in-charge . All kinds of soil.
2Filling available excavated earth (Excluding rock) in trenches, plinth,sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering. Lead up to 50 m and for all lift.
312mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 4 ( 1 cement : 4 fine sand)
415 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
5Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
6Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
7Providing and laying in position cement concrete of specificed grade excluding the cost of centering and shuttering - All work upto plinth level 1:5:10 (1 Cement: 5 coarse sand (zone-III) derived from natural sources: 10 graded stone aggregate 40mm niminal size derived from natural sources)
8Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. a) 150 mm nominal dia Pipes
9Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer in-charge.
10Providing and laying in position cement concrete of specificed grade excluding the cost of centering and shuttering - All work upto plinth level 1:2:4 (1 Cement: 2 coarse sand (zone-III) derived from natural sources: 4 graded stone aggregate 20mm niminal size derived from natural sources)
11Centering and shuttering including strutting, propping etc. and removal of form work for : Foundations, footings, bases for columns
12Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. a) in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submittingstrata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90metre depth below ground level . All types of soil, 300 mm dia
14Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. (a) upto 90 metre depth below ground level Rocky strata including Boulders 300 mm dia
15Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
16Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (ElectricResistance Welded) FE 410 mild steel screwed and socketed/plain ended casing pipes of required dia, conforming to IS: 4270, of reputed & approved make, including painted with outside surface with two coats of anticorrosive paint of approved brand and manufacture, including required hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer-in-charge. (a)150 mm nominal size dia having minimum wall thickness 5.00 mm
17Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : a)Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
18Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. a) 60 mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern.
19Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
20Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
21Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
22Providing and fixing of non woven Geotextile having thinkness of 400 GSM, Having minimum tear Strength of 250 ASTM D4533,width wise atleast215 ASTM D4533 having puncture strength of 1550 pluse as per ASTM D6241 Having elongation at Brack % of 57 plus as per ASTM D 4595 in Two layers, made out of long fibers to hold the mudules anf protect liner including cutting ,sizing ,head welding, and needle punched for high porosity and proper percolation. Complete as per entire satisfaction of engineer-in-charge
23Providing and fixing of CGWB/GRIHA approved Pure Rain Filter 700mm dia with 300mm dia inlet and outlet to accumudate storm water having desilting suspended solid catcher made out of FRP with strainers steel 304 grade strainers, having steel bucket of 600micron capable of eliminating finer particulate matter upto160mmicron filtration made of SS net with long fibre foam of 25mm thickness, Blue color, filitration capacity 40-80 kiloliters etc. Total height of filter 2000mm including two filter extension of size 600 mm, complete in accordance to the desgin, drawing and specification complete as per entire satisfaction of Engineer-in-Charge.
24Extra for add for providing & fixing FRP (FIBER REINFORCED POLYMER) based mirofilter drum/ extension of 700 mm dia CGWB/GRIHA approved pure rain filtersdia Accordance to the design , drawing and specification complete as per entire satisfaction of Engineer-in-Charge
25Providing and fixing UPVC pipe of working pressure 6kg per square cm confirming to IS:4985 including jointing with sealing ring confirming IS:5382 leaving 10mm gap for thermal expansion 300mm dia UPVC pipe
26Providing and installing in position FRP Inspection Chamber of nominal size 500x500x500 mm for polymer structure as above, weighing not less than 10 kgs each in an approved manner including FRP cover for inspection chamber weighing not less than 3 kg and as approved by the Engineer-in-charge complete as required
27Constructing brick masonry manhole (silt chamber type) inside size 1.20mX0.90mx1.20m deep with FPS brick class designation 75 in cement mortar 1:4 (1 Cement: 4 coarse sand ) 150mm thick RCC top slab with 500mm dia opening in cement concrete 1:2:4 (1 cement: 2 C/sand: 4 graded stone agg, n/size reinforced with 18.92 kg cold twisted sreel bars 20cm foundation concrete 1:4:8 (1 cement: 4 C/sand: 8 graded stone agg 40mm size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 C/sand) finished with a foating coat of neat cement and providing 75 mm thick bed concrete in 1:2:4 mix (1 cement: 2 C/sand: 4 graded stoneagg . 20mm n/size) including neat cement punning inside the manhole complete as per standard design/depth shall be measured from invert level of manhole excluding cost of manhole cover and frame which shall be paid for separately etc. All complete as per direction of engineer-in-charge.
28Providing and installation in position recycled co-polymer modular Rain water harvesting structure with required number of large plate (685*410 mm, weight not less than 1200Gram ) and small plate (430*410 mm, weight not less than 600 Gram) with +-1% so as to ensure 96 % void volume ratio fixed in arrangements as per specified pattern/design. Four Plate (Small) configurations. Material used is 100% recycled co-polymer. Design of the modules (Large and small plates) is based on water molecule Structure.
29MF 0.973=Y
30Cost index at 3% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57740127
AUTHORITY Local Bodies
TENDER VALUE 15 Lakhs
LAST DATE 05-10-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for maintenance of Various Scheme Under Na -Ii/Ez.Repair And Maintenance Of Rain Water Harvesting System At Dda Staff Club Mayur Vihar Phase-I.
Basic Detail
Tender No 24/EE/EMD-6/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 26 Sep 2026
Submission Date 05 Oct 2026
Open Date 06 Oct 2026
Finance
Tender Value 15 Lakhs
Tender Fee Ref. Documents
EMD 30010
Exemption Not Available
Document List
24tender.pdf
4972e284-4ebf-4ece-88e8-0c0642e86e3e.html
BOQ_975026.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 06, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
pdf

24tender.pdf

html

4972e284-4ebf-4ece-88e8-0c0642e86e3e.html

xls

BOQ_975026.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender