Tender For External Repair And Rehabilitation Work Including External Painting Of Ty - Ii & Ty - Iii Combined Block And Ty - Iv Block Of Staff Quarters In Mw C Us, Daltonganj.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Oct 2026
2 days left
EMD
18274
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Palamu → Jharkhand
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for External Repair And Rehabilitation Work Including External Painting Of Ty - Ii & Ty - Iii Combined Block And Ty - Iv Block Of Staff Quarters In Mw C Us, Daltonganj.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:2:4 (1 Cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 3 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 4 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for : |
| 6 | Suspended floors, roofs, landings, balconies and access platform |
| 7 | Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 8 | Weather shade, Chajjas, corbels etc., including edges |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level. |
| 10 | Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 11 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. |
| 12 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 13 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 14 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 15 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry , but excluding the cost of nosing of steps etc. complete. |
| 16 | (a) 40 mm thick with 20 mm nominal size stone aggregate . |
| 17 | Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavements etc. |
| 18 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 19 | 110 mm diameter |
| 20 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. |
| 21 | Single tee without door |
| 22 | 110x110x110 mm |
| 23 | Bend 87.5° |
| 24 | 110 mm bend |
| 25 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /seIf tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 26 | 12 mm cement plaster of mix : |
| 27 | 1:4 (1 cement: 4 fine sand) |
| 28 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 29 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 30 | Applying priming coat : |
| 31 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 33 | One or more coats on old work. |
| 34 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 35 | Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface). |
| 36 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge. |
| 37 | With cement mortar 1:4 (1 cement : 4 fine sand). |
| 38 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 39 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 40 | Renewal of old putty of glass panes (length) . |
| 41 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 42 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge |
| 43 | Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 44 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge |
| 45 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer in-charge. |
| 46 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 47 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply , including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall. |
| 48 | 15 mm nominal dia Pipes. |
| 49 | 20 mm nominal dia Pipes |
| 50 | 25 mm nominal dia Pipes |
| 51 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of steel nails etc. complete as per direction and satisfaction of Engineer in charge. |
| 52 | 110 mm |
| 53 | Providing and Fixing PTMT Gate valve of approved quility: |
| 54 | 20 mm nominal bore |
| 55 | 25 mm nominal bore |
| 56 | Grading roof for water proofing treatment with |
| 57 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) |
| 58 | Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge . |
| 59 | 50 mm average thickness |
| 60 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. |
| 61 | Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make |
| 62 | Repair the damaged RCC surface with 50mm average thickness in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 10 mm nominal size). |
| 63 | Providing and fixing single scaffolding system on the exterior side of building made with 75mm dia and above (approx) bamboo tree 1.00 m centre to centre horizontal & vertical for repair of projected roof and maintaining it in a serviceable condition for the required duration as approved and removing it there after complete as per direction of Engineer-in-Charge. |
| 64 | Easy adjustment of steel collapsible gate for its easy opening and closing as per the direction and satisfaction of E.I.C. |
| 65 | Repair of steel window for its easy opening and closing including cutting of old hinges from shutter and fixing of new box hinges etc. at site by proper arrangement of necessary welding machine, necessary scafolding upto 3rd floor of quarter block as required and as directed by Engineer - in - Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysOct 10, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender