Tender For Supply, Erection, Installation, Testing & Commissioning Of 33Kv Overhead Line And 33/0.415Kv Distribution System At Mbrapp Site For Field Hostel.
Tender Overview
Project Description
Tender for Supply, Erection, Installation, Testing & Commissioning Of 33Kv Overhead Line And 33/0.415Kv Distribution System At Mbrapp Site For Field Hostel.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-Oct-2026 | Corrigendum 1 | Date | 28-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | SUPPLY & TRANSPORTATION OF 33kV/433V DISTRIBUTION SYSTEM |
| 2 | 33kV Overhead line |
| 3 | Supply of 36 ft lattice tower complete with all members, bracing, bolts, nuts, washers, tower accessories and as per a technical specification |
| 4 | Supply of 42 ft lattice tower complete with all members, bracing, bolts, nuts, washers, tower accessories and as per technical specification |
| 5 | Supply of ACSR 'Raccon' conductor as per technical specification |
| 6 | 33 kv polymer pin insulator with conductor holding fitting, clamps and accessories as per technical specification |
| 7 | 33 kv polymer Disc insulator with conductor holding/tension fitting hardware and accesories as per technical specification |
| 8 | Supply of protective Guarding with GI wire mesh for road/utility crossings including supports and accessories as per IS 5613 and Technical Specifications |
| 9 | Stay set complete with stay rod, anchor plate, turnbuckle, thimble, stay insulator, GI stay wire and clampsand Accessories as per technical specification |
| 10 | 33/.433kV Substation |
| 11 | Supply of 800 A, 33 kV outdoor Load Brak Switch Panel, complete with operating mechanism, IEC 60265/IS9920, HRC Fuse, IP 65 supporting structure, pipes, clamps, nuts, bolts and all accessories, as per Technical Specifications. |
| 12 | Supply of 100 A, 33 kv Horizantial/vertical polymer GI isolator including 2 pole Structure complete with operating mechanism, pipe, structure, clamps, hardware and accessories etc as per technical specification |
| 13 | Supply of 33/0.433 kV, 500 kVA, 3-phase, Dyn11, ONAN distribution transformer, conforming to IS 1180 and complete with standard fittings and accessories, as per Technical Specifications. |
| 14 | Supply of 33 kV Lightning Arresters (LA), polymeric type, complete with mounting arrangement, clamps and accessories, as per Technical Specifications. |
| 15 | Supply of outdoor, floor-mounted, double-door LT Distribution Panel, 433 V, 3-phase, 4-wire, minimum IP-65 enclosure, with 2 Nos. 800 A, ACB incomer inculding protection system; 5 Nos. 250 A, 4-pole MCCB outgoing feeders; 2 Nos. 100 A, 4-pole MCCB outgoing feeders: 4 Nos. 32 A, 4-pole MCB outgoing feeders; 4 Nos. 63 A, 4-pole MCB outgoing feeders, complete with copper busbars, MFM with CTs, selector switches, indicating lamps, control wiring, terminal blocks, gland plates, cable glands, lugs and all accessories, conforming to IS/IEC 61439 and relevant standards, as per Technical Specifications. |
| 16 | Supply of outdoor, floor-mounted, double-door LT Distribution Panel, 433 V, 3-phase, 4-wire, minimum IP-65 enclosure, with 3 Nos. 250 A, MCCB; 2 nos of 120 A MCCB Outgoing feeder, 4 Nos. 32 A, 4-pole MCB outgoing feeders; 4 Nos. 63 A, 4-pole MCB outgoing feeders, complete with copper busbars, MFM with CTs, selector switches, indicating lamps, control wiring, terminal blocks, gland plates, cable glands, lugs and all accessories, conforming to IS/IEC 61439 and relevant standards, as per Technical Specifications. |
| 17 | 3.5C x 400 mm²Aluminium XLPED insulated 1.1kV Grade Cable inculding connectors, glands, lugs, route marker as per Technical Specification |
| 18 | 3.5C x 120 mm²Aluminium XLPED insulated 1.1kV Grade Cable as per Technical Specification |
| 19 | 3C x 95 mm² Aluminium XLPE insulated 33kV grade cable as per technical specifications |
| 20 | Heat Shrik 33kv grade Termination kit as per technical specifications |
| 21 | Supply of 140 kVA, 433V, 3-phase DG Set, complete with engine, alternator, control panel, AMF/ATS arrangement, batteries, battery charger, fuel tank and standard accessories, as per Technical Specifications. |
| 22 | VCB for Main incoming 33kV line |
| 23 | Supply of outdoor VCB for 33KV overhead line inculding all protection devices, Panel, relay, CT PT set and all accessories required for operation as per technical specifications. |
| 24 | Supply of Outdoor Bus bar of 60mm OD x 5 mm thick aluminium tube of Min 12 Meter lenth suitable for 3 outgoing feeder 33KV 3 phase incuding supporting struture, clamps, Insualtors and other accesores required as per Technical specifications |
| 25 | Supply of 100 A, 33 kv Horizantial/vertical polymer GI isolator including 2 pole Structure complete with operating mechanism, pipe, structure, clamps, hardware and accessories etc as per technical specification |
| 26 | SUPPLY OF OTHER MISCELLANEOUS |
| 27 | Supply of 33 kV, 10 A Drop-Out Fuse (DOF), complete with mounting arrangement, operating rod, clamps and accessories, as per Technical Specifications. |
| 28 | Supply of Rubber mat 3 mm ISI mark as per technical Specifications |
| 29 | Supply of suitable CO2/DCP fire extinguishers. |
| 30 | Supply of Danger Plate of size 300 mm x 200 mm GI/MS Sheet |
| 31 | Supply of safety precation chart as per technical specification |
| 32 | Supply of fire bucket stand with 4 bucket as per technical specification |
| 33 | Supply of Combination of type 2 surge protection and arrester backup fuse, with monitoring of arrester and arrester backup fuse, in combination with a status indicator and remote indication contact. Design: 4-conductor system (L1, L2, L3, PEN), mounting on NS 35 DIN rail for 433V System. |
| 34 | STORAGE, HANDLING, ERECTION, INSTALLATION, TESTING & COMMISSIONING OF 33 kV / 433 V DISTRIBUTION SYSTEM |
| 35 | 33kV Overhead line |
| 36 | Storage, handling, erection, installation, testing and commissioning of 36 ft lattice tower complete with M 20 foundation of Minimum 1 x 1 x 1.5 Meter with earthing at each tower as per a technical specification |
| 37 | Storage, handling, erection, installation, testing and commissioning of 42 ft lattice tower complete with M 20 foundation of Minimum 1 x 1 x 1.5 Meter with earthing at each tower as per a technical specification |
| 38 | Storage, handling, erection, installation, testing and commissioning of ACSR 'Raccon' conductor as per technical specification |
| 39 | Storage, handling, erection, installation, testing and commissioning 33 kv polymer pin insulator with conductor holding fitting, clamps and accessories as per technical specification |
| 40 | Storage, handling, erection, installation, testing and commissioning 33 kv polymer Disc insulator with conductor holding/tension fitting hardware and accesories as per technical specification |
| 41 | Storage, handling, erection, installation, testing and commissioning of wire GI mesh of 25 mm x 25 mm/net at road/utility crossings including supports and accessories |
| 42 | Storage, handling, erection, installation, testing and commissioning Stay set complete with stay rod, anchor plate, turnbuckle, thimble, stay insulator, GI stay wire and clampsand Accessories as per technical specification |
| 43 | 33/.433kV Substation |
| 44 | Storage, handling, erection, installation, testing and commissioning of 800 A, 33 kV outdoor Load Brak Switch Panel, complete with operating mechanism, IEC 60265/IS9920, IP 65 supporting structure, pipes, clamps, nuts, bolts and all accessories, as per Technical Specifications. |
| 45 | Storage, handling, erection, installation, testing and commissioning of 100 A, 33 kv Horizantial/vertical polymer GI isolator including 2 pole Structure complete with operating mechanism, pipe, structure, clamps, hardware and accessories etc as per technical specification |
| 46 | Storage, handling, erection, installation, testing and commissioning of 33/0.433 kV, 500 kVA, 3-phase, Dyn11, ONAN distribution transformer, including foundation, oil filling, earthing, cable termination and all associated works, complete as per Technical Specifications. |
| 47 | Storage, handling, erection, installation, testing and commissioning of 33 kV Lightning Arresters, including mounting, earthing, clamps and all required accessories, complete as per Technical Specifications. |
| 48 | Storage, handling, erection, installation, testing and commissioning of LT Distribution Panel, including cable termination, gland, lugs, internal wiring, earthing and all associated works, complete as per Technical Specifications. |
| 49 | Storage, handling, laying, testing and commissioning 3.5C x 400 mm²Aluminium XLPED insulated 1.1kV Grade Cable inculding connectors, glands, lugs, route marker as per Technical Specification |
| 50 | laying of cable through trench of 900 x 700 mm as per Technical Specification |
| 51 | Installation, testing and Commissioing of heat Shrinke 33kV grade Termination Kit |
| 52 | Storage, handling, erection, installation, testing and commissioning of 140 kVA, 433V, 3-phase DG Set, including foundation, anti-vibration arrangement, earthing, fuel system, exhaust system and all associated works, complete as per Technical Specifications. |
| 53 | VCB for Main incoming 33kV line |
| 54 | Storage, handling, erection, installation, testing and commissioning outdoor VCB for 33KV voltage level inculding all protection devices, Panel, relay, CT PT set and all accessories required for operation as per technical specifications. |
| 55 | Storage, handling, erection, installation, testing and commissioning Outdoor Bus bar of 60mm OD x 5 mm thick aluminium tube of Min 12 Meter lenth suitable for 3 outgoing feeder 33KV 3 phase incuding supporting struture, clamps, Insualtors and other accesores required as per Technical specifications |
| 56 | Storage, handling, erection, installation, testing and commissioning 100 A, 33 kv Horizantial/vertical polymer GI isolator including 2 pole Structure complete with operating mechanism, pipe, structure, clamps, hardware and accessories etc as per technical specification |
| 57 | INSTALLATION OF OTHER MISCELLANEOUS |
| 58 | Installation of Danger Plate of size 300 mm x 200 mm GI/ Al Sheet as per technical Specifications |
| 59 | Installation of safety precation chart as per technical specification |
| 60 | Installation of fire bucket stand with 4 bucket as per technical specification |
| 61 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required. |
| 62 | OTHER MISCELLANEOUS & CIVIL WORKS FOR 33 kV / 433 V DISTRIBUTION SYSTEM |
| 63 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. |
| 64 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 65 | All kinds of soil |
| 66 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth upto 1km lead and any lift, complete all as per Technical specification and as directed by the Engineer-in- charge. |
| 67 | All kinds of soil |
| 68 | Providing and laying in position plain cement concrete of M10 grade 1:3:6 [1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size] including the cost of centering and shuttering complete all as per Technical specification and as directed by the Engineer-in-charge. |
| 69 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 70 | Providing and fixing galvanised steel corrugated sheets of 0.50 mm thickness conforming to relevant IS standards, roofing up to any pitch and fixing with 8 mm dia. galvanised iron J or L hooks, bolts and nuts with GI plain and bitumen/EPDM washers, or with suitable self-drilling fasteners and EPDM washers, including necessary overlaps, cutting sheets to size and shape wherever required, complete in all respects (excluding the cost of purlins, rafters and trusses). Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 10 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender