Tender For Providing Earthing For Tower Body & Lightning Protection, Electrical Cabling, 15 Kva Dg Shifting And Connected Works For Newly Proposed Od Bts At Narakoduru(Gt4112), Guntur Ba
Tender Value
2.55 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
7 days left
EMD
5108
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Guntur → Andhra Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Providing Earthing For Tower Body & Lightning Protection, Electrical Cabling, 15 Kva Dg Shifting And Connected Works For Newly Proposed Od Bts At Narakoduru(Gt4112), Guntur Ba
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer (Electrical) , BSNL Electrical Division, Vijayawada Name of Work: Providing Earthing for Tower Body & Lightning protection, Electrical cabling, 15 kVA DG shifting and connected works for newly proposed OD BTS at Narakoduru(GT4112), Guntur BA NIT No: 68/BSNL/EDV/2026-27, Dt: 26.09.2026 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER HSN Code TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. DESCRIPTION OF ITEM Item Code / Make Qty Unit Estimated Rate inRs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Basic unit price exclusive of all taxes & Charges FF Packing % FF Packing Amount CGST % CGST Amount SGST% SGST Amount IGST % IGST Amount All-inclusive Unit Cost (5+7)+[(9+11) or 13] Total price inclusive of all charges (3 x 14) Amount of Input tax Credit (ITC) to be availed [(9+11) or 13] Total Amount of Input tax Credit (ITC) to be availed (3 x 16) Unit price excluding ITC amount (net unit cost) (14-16) Total price inclusive of all levies and charges but excluding ITC (net total cost) HSN for goods and SAC for services Total price inclusive of all levies and charges but excluding ITC (net total cost) TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Earthing with existing 4 Nos. GI plates for Tower body earthing / Lightning protection earthing / Equipment earthing etc. by observing the following procedure. (A) Digging of earth pit of Min size 2mtr x 2mtrx 10 feet deep ( for installing GI Earth plates at the corners ) and refilling the same after installing the earth plate system. (B) Installation of 4 Nos. GI earth plates of size at the corners of the Earth pit by drilling holes to the plates, making connections to all the four plates for extending earth using GI bolts & nuts, washers, lead washers etc. (C) Providing masonary enclosure of suitable size for the earth pit with Cast Iron/MS hinged / Cement concrete cover plate and making sign writing.(D) Transportation of GI plates from Autonagar Storeyard to new BTS site i/c loading and unloading etc as required. |
| 3 | Extra for excavation of above earth pit for each 1 Feet depth & refilling as required. |
| 4 | Providing and fixing lightning conductor finial made of 25mm dia 600 mm long GI pipe ( B-class) having single prong at top with suitable size GI base plate and Hylam sheet including holes etc.as required. |
| 5 | Supplying & fixing of GI / MS clamp of suitable size for fixing on surface of wall/on tower pole for running earth strip & Elec cables etc as required |
| 6 | Supplying & fixing of suitable size RED color DMC/ SMC insulator for 25x5mm GI strip on surface of wall/ on wall Clamp with suitable screws/bolt nuts etc as required. |
| 7 | S&F of 25x5 mm GI strip on surface / in recess/ in ground for connections as required ( Horizontal/Vertical run) |
| 8 | Supplying & fixing of 3 chamber Outdoor Panel ( min size : 75cm (H) x 75 cm (W)x 30 cm (D)) made up of 16 G MS sheet for housing 1Ph/3Ph Energy Meter ( direct type)-1NO, 100A Fuse cutout-3nos with Neutral link/ MCBs and 63A ON Load Changeover switch -1No on existing MS angle iron frame/on surface of Wall, painting complete as required. (Panel specification : a) Panel shall be Made up of 16G MS sheet b) All 3 chambers shall be individually separated, shall have Individual doors with locking arrangement. c) Meter chamber shall have opening with Glass provision for meter reading from outside d) change over Switch chamber shall be double door. e) All chambers shall have suitable holes & rubber seals for cable entry. f) Panel shall be powder coated. g) suitable size hylam sheet & DIN rail shall be provided inside panel chambers wherever necessary for fixing Meter/ fusecutouts/ MCBs etc, ) |
| 9 | Supply and making of MS stand made up of 50mm x 50mm x 5mm MS Angle for fixing above OD meter panel above 1.0 mtrs height above ground level including welding, making holes, cement concrete foundation, transportation etc complete as required. |
| 10 | Supplying & fixing additional GI sheet roof of suitable size for OD meter-fuse box made up of 25x5 GI strip supports & 24G L-shaped GI sheet to the existing Iron frame as required. |
| 11 | Supplying & laying of single core 25 Sq.mm weather proof Aluminium power cable of 1.1 KV grade in Existing PVC/ MS conduit/open/loop/existing GI Wire support as required. |
| 12 | Supplying & laying 10 SWG GI wire for support of OH service cable as required. |
| 13 | Supplying & Laying of 4C 16Sqmm PVC/XLPE insulated 1.1KV grade armored Aluminium cable for extending of supply on surface/in existing PVC/ soil as required. |
| 14 | Supplying & fixing of the following size rigid PVC pipe (ISI Make) on surface of wall/ recess as reqd. a) 40 mm dia Rigid PVC pipe |
| 15 | b) 25mm dia Rigid PVC Pipe |
| 16 | c) 40mm dia B-class GI pipe |
| 17 | d) 50 mm dia Rigid PVC pipe |
| 18 | S/F of GI busbar of size 300mm x 50mm x 6mm thick on suitable size insulators as reqd. |
| 19 | Supplying and fixing suitable size modular Box with cover plate on surface or in recess, including providing and fixing 3 Pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 20 | Supplying & fixing of following electrical items on surface of wall/ in existing Power panel complete as required . a) 100A Fuse Cut Outs with extended busbar links |
| 21 | b) 100A Neutral Link/Busbar link |
| 22 | Supplying & fixing of 4 pole 63A Onload changeover switch suitable for 415V, 3 Phase AC power supply in the existing power panel as required. ( Make : HPL) |
| 23 | Fixing charges for the APCPDCL 3 phase / 1 PH energy meter on existing hylum/wooden sheet by co-ordination with CPDCL staff, testing complete as required. |
| 24 | Supplying and laying of 3 core 1.5 sq. mm PVC insulated copper conductor cable as required. |
| 25 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a)2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 26 | Suppplying & fixing of prewired 20W LED batten type light fitting on surface of wall with suitable wooden/PVC blocks and ceiling rose making connections testing etc complete as required. ( Make: Crompton / Bajaj/ SS make) |
| 27 | Supplying & fixing of following MCB DB/ MCBs suitable for 240V/415V, 50Hz Supply etc as required.(M/s Legrand) a) 63A 4P MCB (C Curve) |
| 28 | b) 2/4 Way MS Enclosure |
| 29 | c) 6-32A SP MCB (C Curve) |
| 30 | Supplying and laying of the 10 Sqmm size PVC insulated FR copper conductor cable including terminations in the existing PVC pipe as reqd. ( M/s. Polycab/ equivalent make) |
| 31 | Transportation of 1 No telephone pole from TE Narakoduru and errection of the same at requisite place near tower/APCPDCL meter for running service wire including labour for digging, lifting, loading/unloading etc as required. |
| 32 | Supplying & fixing of PVC Enclosure (min 400mm x 400mm) with hinged door for outdoor use for housing , 4 way enclosure with 63A FP MCB- 1no, 2Way Enclosure - 1 No & 15A Power plug and sufficient space for cable termination on surface of wall as required |
| 33 | Dismantling of the existing split AC Unit complete with indoor unit, outdoor unit along with OD stand, refrigerant piping, shifting the dismaltled items to a safe place in exchange premises and handing over to the incharge etc as required. |
| 34 | Dismantling of following electrical items, placing the dismantled items in the exchange premises and handing over to the incharge etc as required.a) MV Panel i/c removal/cutting of cable connectionsb) EB Meter Board and Fusecutouts panelc) Any other electrical fittings/items |
| 35 | Supplying & fixing of shading/ roof for above outdoor box made up of 25x25x3mm L angle brackets -2nos & suitable size Gi sheet (Approx 2 ft x 1.5 ft) (on L-Angle brackets) on wall surface i/c bending, painting, Silicon Gel for sealing gaps complete as required. |
| 36 | Providing CC plinth /bed for EA set of suitable size with cement, sand & 20 mm stone aggregate cement in 1:2:4 ratio, sand cushion bed at bottom of bed, plastering of all sides for neat finishing with cement mortar complete as reqd |
| 37 | Shifting of 15 kVA Capacity accoustic DG set with all accessories like Exhaust pipe, Control Panel etc at Old BTS site Narakoduru old location to new BTS location by suitable transport vehicle, using Crane / Tripod arrangement for loading/ unloading at the above station, towing the DG set with labour where crane is inaccessible and placing the DG set on existing CC plinth at new BTS location complete as required. |
| 38 | Installation, testing and commissioning of the 15 KVA E/A set with all equipments, accessories and associated items on the existing cement concrete floor / foundation, tightening of bolts and nuts,including Fuel line connections, errection of Silencer & Exhaust pipe, making cable & Earth connections, checking of Engine/ alternator parameters etc as required. |
| 39 | Providing Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. without charcoal/ coke and salt as required. ( For DG neutral) Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select, Excess (+), Less (-) 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysOct 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender