Tender For Maintenance & Operation Of Street Light Under Pwd Emd South East, New Delhi During. 2026-27.(Sh:- Supply Installation Testing and Commissioning of Poles With Led Fittings Near Jasola & Sarita Vihar Area Under Sub Division Emsd-Iii, Sunligh
Tender Overview
Project Description
Tender for Maintenance & Operation Of Street Light Under Pwd Emd South East, New Delhi During. 2026-27.(Sh:- Supply Installation Testing and Commissioning of Poles With Led Fittings Near Jasola & Sarita Vihar Area Under Sub Division Emsd-Iii, Sunlight Colony, New Delhi.)
BOQ
| Sl. No. | Item Description |
| 1 | Supplying & erection of flange mounted hot dip galvanized octagonal poles of 8 mtrs. height made from 4 mm thick HT steel plate having bottom dia of 150 mm & top dia of 70mm complete with window with flash cover at a height of 0.5 mtrs from the base for cable termination block etc. and galvanized base plate of size 240 mm x 240 mm x 16 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination : a) Supply & fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 Nos. GI strip 4 mm thick of suitable length and having suitable size tapped holes - 10 Nos as reqd.b) Supply and fixing 63 amps. terminal block suitable for 25 sq. mm conductor- 4 Nos. & shorting links - 5 Nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length - 1 Nos. on the existing laminated sheet. c) Supply & fixing of 6 amp. SP MCB 'C' characteristics Curve - 1 Nos, earth stud - 1 Nos, welded at suitable height two nos washers, springs washers & nuts. d) Cable support clamp sutiable for 4 Nos. of 4 x 16 sqmm cable. |
| 2 | Supplying & erection of flange mounted hot dip galvanized octagonal poles of 10 mtrs. height made from 4 mm thick HT steel plate having bottom dia of 200 mm & top dia of 100mm complete with window with flash cover at a height of 0.5 mtrs from the base for cable termination block etc. and galvanized base plate of size 320 mm x 320 mm x 20 mm thick on the existing cement concrete pedestal as required i/c supplying and fixing of the following in the window box provided for cable termination : a) Supply & fixing 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 Nos. GI strip 4 mm thick of suitable length and having suitable size tapped holes - 10 Nos as reqd.b) Supply and fixing 63 amps. terminal block suitable for 25 sq. mm conductor- 4 Nos. & shorting links - 5 Nos. on DIN channel i/c pdg. and fixing DIN channel of suitable length - 1 Nos. on the existing laminated sheet. c) Supply & fixing of 6 amp. SP MCB 'C' characteristics Curve - 1 Nos, earth stud - 1 Nos, welded at suitable height two nos washers, springs washers & nuts. d) Cable support clamp sutiable for 4 Nos. of 4 x 16 sqmm cable. |
| 3 | Fabrication, supplying & fixing of Double arm galvanized iron bracket of 1mtr long arm of suitable dia on the existing pole with tightening bolts etc. as reqd. (As per approved Drawing.) |
| 4 | Providing and laying in position 1:2:4 reinforced cement concrete foundation of size 650mm (L) X 650mm wide and 1400mm deep i/c excavation of earth, providing , cutting, bending and placing in position, reinforcement of cold twisted bars of 12mm dia - 1400mm long (approx)-10 Nos. and reinforcement ring of cold twisted bar of 8mm dia - 1600mm (approx) - 10 nos. (with 150mm spacing) as required with positioning of foundation bolts (as per item below) as shown in the item below and providing 75 mm. (O.D.) DWC, HDPE pipe for cable entry & exit as required. |
| 5 | Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR -15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin),SDCM (Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 6 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 7 | a) 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Providing, laying, testing & commissioning of 'B' class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 9 | a) 50 mm |
| 10 | Supplying and laying of one number XLPE insulated & PVC sheathed & armoured aluminium conductor cable of 1.1 KV grade of following size on surface/recess etc as reqd. |
| 11 | a) 4x25 sqmm |
| 12 | Supplying and laying of one number XLPE insulated & PVC sheathed & armoured aluminium conductor cable of 1.1 KV grade in the existing RCC/ HUME/ METAL pipe as required. |
| 13 | a) 4x25 sqmm |
| 14 | Providing, boring and laying HDPE pipes (ISI Marked) of 120 mm O.D. confirming to IS:4984- 1995 as amended up to date with pressure rating of 4 Kg./Sq.c.m. by trenchless technology with no dig method by making bore hole in horizontal direction across the road as per direction of Engineer-In-Charge with mauling equipment i/c jointing cleaning, rodding of pipe. Providing, suitable covers on mouth of pipes, excavation of pits of required size at appropriate depth but not less than 0.6 mtr. etc. complete as reqd. |
| 15 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 16 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required. |
| 17 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 18 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 19 | supplying and drawing of 3core 1.5sqmm size PVC insulated PVC sheathed copper conductor (flexible) muiltcore cable in the existing upto 8mtr poles and bracket from cable termination connection to the fitting i/c providing suitable copper lugs connections etc as reqd. |
| 20 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge. |
| 21 | a) Nominal concrete 1:4:8 or leaner mix (including equivalent design mix) |
| 22 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level |
| 23 | a) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size de rived from natural sources) |
| 24 | Supplying, fabrication & installation of outdoor type cubical feeder pillar of size not less than 1.56 sqmtrs.(face area) depth not less than 30 cm, made out of M.S. sheet 2mm thick (14 SWG) duly compartmentalized having 4 strip aluminium busbar of 300 Amp capacity double door with locking arrangement for protection from rain, dust, duly fixed on MS angle iron frame work of size 50mm x 50mm x 6mm (NS) 90 cm long legs out of which 45 cm duly grouted in cement concrete 1:2:4 (1 cement : 2 sand :4 stone aggrete 20mm) and arrangement for fixing of following accessories mouted inside the cubical panel i/c making connection, inter connection with aluminium thimbles, earthing with two nos. earth studs duly Powder coated complete etc. as reqd. (Drawing of Feeder Pillar should be approved by Engineer-in-Charge before installation at site) i/c supplying & fixing of following accessorries in the existing cubical panel board/feeder pillar including connection testing etc. as reqd. (i) 200 Amp, 25 KA FPMCCB -1No.(Ics=100% Icu) (ii) 63 Amp, TPMCCB, 25 KA - 4 Nos.(Ics=100% Icu) (iii) Voltmeter 0-500 Volt 96 sqmm flush type with selector switch. -1No. (iv) Ammeter 0-200 Amp 96 sqmm flush type with selector switch & 200/5 Amp ratio CT's. -1No. (v) LED Indication lamps (RYB) with 2 Amp. SPMCB fitting- 3 Nos. (vi) Power Contactor 3 pole -200 Amp-1No. (vii) Digital Timer-1No. (viii) Danger Notice plate- 2 Nos. (ix) Godown Lock-3 Steps- in Front door- 2 Nos. |
| 25 | Supplying and fixing of 100amp 3pole power contractor rating 125-150amp in the existing street light panel i/c connection with thimble wire etc complete as reqd. |
| 26 | Supplying and fixing of FM1/Quartz timer switch, 150Hrs battery backup working for , 110VAC - 240VAC base and din mounting suitable for ON/OFF operation of street light in existing feeder pillar complete etc as reqd. |
| 27 | Credit for dismantle materials |
| 28 | Assorted : LED Post Top Fitting/Street light/flood light fitting |
| 29 | Assorted : cable |
| 30 | Assorted : Pole Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender