Tender For repair maintenance Electrical & Mechanical Services At Mahatma Gandhi Institute For Combating Climate Change (Govt. Of Nct Of Delhi), Bakoli, Alipur, Delhi-110036 During 2026-27.
Tender Value
9.14 Lakhs
Estimated cost
Bid Submission
03 Oct 2026
5 days left
EMD
18287
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for repair maintenance Electrical & Mechanical Services At Mahatma Gandhi Institute For Combating Climate Change (Govt. Of Nct Of Delhi), Bakoli, Alipur, Delhi-110036 During 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | SH:- I ( Maintenance & Operation) Providing services for day to day maintenance & upkeep of all EI & Fans, Compound light/street light, DBs, MCBs, LT Panel & all switch gears i/c attending and rectifying the complaint and operation of drinking water pump sets in one shift on all days excluding Sunday and Saturday & up keep all E & M services healthy, functional i/c neat & clean always etc as reqd. by deploying following staff in general shift and as per attached terms and conditions as per reqd.a) Wiremen cum operator -1 No.b) Khallasi -1 No. |
| 2 | SH:- II (EI Work)Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. |
| 3 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS /HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 1.5 sq. mm |
| 5 | 3 x 4 sq. mm |
| 6 | 3 x 6 sq. mm |
| 7 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 8 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia. (OD 63 mm & ID 51 mm Nominal) |
| 9 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 11 | Supply of one number XLPE insulated and PVC sheathed aluminium conductor, armoured underground power cable of 1.1 KV grade of following size complete etc. as required.2 x16 sq.mm |
| 12 | 4 x16 sq.mm |
| 13 | Lifting of existing submersible bore well / open well 3 HP to 10 HP capacity Pump set from the bore well with the help of chain pulley block & tripod stand i/c cartage charge at site from the work shop. |
| 14 | Lowering of 3 HP to 10 HP capacity bore well/open well pumpset in the bore well with the help of chain pulley block and tripod stand i/c cartage charge pump set from work shop to site. |
| 15 | Repairing of following capacity of submersible/monobloc Pumpset i/c replacement of mechanical seal TC/TC upper, mechanical seal TC/TC lower, ball bearing, 'O' Ring, stamping repairing, including dismantling, assembling, commissioning and testing the same on load after making electric connections at site i/c site visit by Engineer and to and fro from site to workshop & back to site etc. complete with credit of dismantle etc as required.Above 3 HP and upto 5 HP |
| 16 | Rewinding of following capacity 3 phase multi-stage submersible / mono-submersible pump-set with suitable size water proof copper conductor wire i/c brazing metalling turning & polishing of shaft, replacement of GM bearing bush, thrust bush, thrust plate, necessary sleeves, pads etc. i/c buy back of dismantled material and making connection, testing and commissioning etc. complete as reqd.Above 3 HP and upto 5 HP |
| 17 | Comprehensive maintenance & Servicing of following capacity Window/Split AC and water cooler installed at the above mentioned site i/c replacement, defective i.e. blower motor, PCB, remote, Plug Top, Starting Capacitor, Running Capacitor, Starting Relay,Thermostat, Propeller Fan, Over load Relay i/c condenser unit, i/c refrigerant gas pipe with insulation, lead wire, etc complete as per terms and conditions attached:-a) Window type AC/ Split type AC of 1.5 TR to 2 TR capacity. (20 Nos. for 8 Months- 160 Jobs (Anual maintenance shall be considere after 1st servicing ) |
| 18 | Supplying & Charging of R 22/410A refrigerent gas for top-up of gas in the existing Split AC i/c leakage testing i/c rectification of leackage complete etc complete as required. |
| 19 | SH:- III (Supply of material)Supply of following materials:-S.P. 5/6 A, one way modular switch, ISI marked |
| 20 | S.P. 15/16 A, one way modular switch, ISI marked |
| 21 | 3 pin 5/6 A modular socket outlet, ISI marked |
| 22 | 6 pin 15/16 A modular socket outlet, ISI marked |
| 23 | Stepped type Modular Fan regulator (2 module) |
| 24 | Modular base & cover plate for 8 module |
| 25 | Modular base & cover plate for 12 module |
| 26 | 6 A, to 32 A, ratings, SP MCB, \\"C\\" curve, 10 KA breaking capacity |
| 27 | 12-15 Watt LED recessed/surface down lighter (Round/Square /Rectangular) SMD Type (System lumen efficacy ≥ 105 < 120 lm/Watt ), Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector complete etc as reqd. |
| 28 | 36 Watt LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) |
| 29 | 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req |
| 30 | 40 Amp DP MCB 10 kA rating \\"C\\" Curve |
| 31 | 63 Amp FP MCB 10 kA rating \\"C\\" Curve |
| 32 | 100 Amp FP MCB 10 kA rating \\"C\\" Curve |
| 33 | 3 pole MCCB, 125A, 16kA Ics=100% Icu and Operational Voltage 690V |
| 34 | 3 pole MCCB, 250A, 25kA Ics=100% Icu and Operational Voltage 690V |
| 35 | 3 pole MCCB, 315A, 35kA Ics=100% Icu and Operational Voltage 690V |
| 36 | 400 mm Wall fan with minimum air delivery 80 m3/min and 1300 rpm etc complete as req. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysOct 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender