Project Description

Tender for Special Repair Of Roof Top Of Bldg No P-11 At New Cantt And Constr Of Pathway Near Block No 1 Near Bldg No P-5 At Staging C , New Cantt Prayagraj

BOQ

Name of Work:- SPECIAL REPAIR OF ROOF TOP OF BLDG NO P-11 AT NEW CANTT AND CONSTR OF PATHWAY NEAR BLOCK NO 1 NEAR BLDG NO P-5 AT STAGING C , NEW CANTT PRAYAGRAJ
Sl. No. Item Description
1Dismantling of brick tiles or terracing tiles single layer on roof & disposal of retrived material upto a distance not exc 100 mtr complete all as specified and directed
2Demolition of mud in roof, any thickness including plastering and leaping ( where full thickness recoved or only a part there of disposal off rubbish upto a distance n.exc 100m, where directed complete all as specified and directed
3M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in roof curbing, padding over roof slab complete all as specified and directed. Note : Average thickness shall not exceed 40mm complete all as specified and directed.
4M&L for rendering 10 mm thick on concrete surface when concrete is green on roof surface in cement mortar 1:3 complete all as specified and directed
5M&L for water proofing treatment on roof slab consisting with following operation complete all as specified and directed :-(i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wire brushes and dusting.(ii) Applying a layer of bitumen primer conforming to IS 3384 @ 0.4Ltr/sqm on the surface.(iii) Laying 3mm thick APP membrane having non-woven polyster matt at core and under surface coated with plastic polythene film. Laying shall be done using butane torch maintaining 100mm i.e overlap & 150mm end overlap, sealing all overlaps complete including treatment at all junctions & corners. The membrane shall be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor.(iv) The Membrane shall have tensile strength of 700N/5cm in longitudinal direction and 450N/5cm in transverse direction at 23 degree celcious, Flow resistance > 120 degree celcious dimensional stability, <0.5% when fested as per ASTM D 5147. The laying of the membrane shall be done through authorized applicator of the manufacturers\\".(v) Applying two coats of bituminous aluminium paint @ 0.30 ltr per sqm over APP membrane on non accessible roof area.
6Removing demolished material to a distance exceeding 250 mtr but not exceeding 500 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
7Dismantling of PVC water storage tank exc 500 ltrs and not exc 1000 ltrs capacity and removing to store complete all as specified and directed.
8S&F 1000 ltrs capacity Rotational moulded polythene water storage tanks in three layers (cylindrical vertical with close top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified and as directed.
9S&F 20mm dia ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe fixed complete all as specified and directed.
10S&F Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipes for 20mm bore of pipe complete all as specified and directed.
11Demolition of stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors, aprons etc complete all as specified and directed
12M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundation, filling and mass concrete complete all as specified and directed
13M&L for heavy duty pavement tiles 400mm x 400mm x 10mm thick coloured for floor/pavement etc & jointed in neat cement slurry and pointed with white cement fixed with colour pigment to match colour of tiles including 15mm thick screed bed in CM 1:4 complete all as specified and directed
14Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillets complete all as specified and directed
15S&F 4mm thick E-boards tiles (Make : Everest) false ceiling with powder coated GI snap grid frame work (Make : Armstrong/Saint Gobain or equivalent as approved) including cutting holes in brick wall built in cement mortar & making good in cement concrete 1:2:4 type BO/Cement mortar 1:3 complete all as specified and directed including all necessary drilling and necessary arrangement to fix electrical items as under complete all as specified and directed:- (a) 25mm x 25mm x 1.6mm thick GI angle powder coated duly plugged @ 600mm centre to centre along perimeter of wall. (b) 25mm x 25mm x 1.5mm thick GI tee powder coated as main and cross runners suspended with 1.6mm dia GI wire suspenders with adjustable clamps and dash free fastners plugging in RCC slab placed @ 600mm centre to centre from perimeter of wall. (c) Fixing of 4mm thick E-boards tiles of size 595mm x 595mm of approved texure and finished complete with two coats of oil emulsion distemper on ceiling.Note : The complete ceiling work shall be done as per manufactures instruction and as directed.
16S&F 10mm thick plaster of paris ceiling (Gypsum false ceiling) to flat/curved surfaces including sunk or raised moulding with POP and finishing complete all as specified over GI frame work including all necessary drilling, cutting to fix electrical items with followings complete all as specified and directed :-(a) GI sheet channel made to shape 0 x 25 x 20mm of 24 gauge fixed with rowel plug with screw 450mm centre to centre along with perimeter of walls. (b) GI sheet channel make to shape 50 x 40mm x 40mm of 24 gauge placed at 600mm centre to centre from perimeter of wall except long wall (in one span). (c) GI sheet intermediate runner of size 45mm x 10mm x 10mm of 24 gauge fixed at 1200mm c/c leaving frame of one side wall (in other span)(d) GI sheet 25mm wide and 20mm gauge suspenders fixed with the screw steel fasteners to roof ceiling @ 1200mm c/c including plugging in RCC slab(e) GI wire mess fixed to framework.
17S&F in repair stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed.
18Taking up or down steel water tubing and connections of 15mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and directed
19Taking up or down steel water tubing and connections of 20mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and directed
20Taking up or down steel water tubing and connections of 25mm bore, fixed in walls, ceiling, floors, trenches etc complete all as specified and directed
21S&F GI Steel water tubes medium grade, ISI marked, galvanised, 15mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.
22S&F GI Steel water tubes medium grade, ISI marked, galvanised, 20mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.
23S&F GI Steel water tubes medium grade, ISI marked, galvanised, 25mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed.
24Cutting chases pinning in making good to facing where required for concealed water tubing and making good cutting not exc 10cm girth in brick walls complete all as specified and directed
25Dismantling structural steel work including doors, gates but excluding framed trusses etc complete all as specified and directed
26M&L for structural steel work with rolled mild steel sections conforming to Gde Fe- 290 Gde E-165) 'A' quality as in main and cross beams, hip and jack rafters, purlins, MS pipe hollow sections where connected to common rafters and running rails & guides for sliding doors, fixed with angle cleats or other connecting plates complete all as specified and directed.
27M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, including dismantling of old sheets of any description complete all as specified and directed
28M&L pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, including dismantling of old sheets of any description complete all as specified and directed
29M&L for preparation of new or previously untreated surfaces of steel or iron of any description over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
30Demolition and breaking up (salt glazed ware, AC, PVC) drain pipes of 100mm dia set in cement mortar complete all as specified and directed
31S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls, 110mm bore complete all as specified and directed
32S&F 75 mm bore PVC (SWR) pipe single socket in any length with rubber ring joints fixed to walls complete all as specified and directed.
33S&F PVC (SWR) Bend 75mm dia complete all as specified and directed.
34S&F PVC (SWR) Bend 110mm dia complete all as specified and directed.
35Demolition of brick work built in cement mortar and removing rubbish complete all as specified and directed
36M&L for Brick work with fly ash old size bricks, straight or curved on plan to any radius in built in cement mortar 1:4 complete all as specified and directed
37Taking down cement plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
38M&L rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface mixed with water proofing compound @ 3% by weight of cement or as per manufacturer's instructions, finished even and fair without using extra cement complete all as specified and directed. Note : WPC shall be measured & paid separately.
39Supply only liquid water proofing compound ISI marked complete all as specified and directed
40M&L for 1 mm thick wall care putty on internal wall over old/new plastered/ unplastered or newly plastered surfaces complete all as specified and directed.
41M&L for preparation of old decorated plastered or unplastered surfaces of walls and applying two coat of oil bound distemper Including cleaning of entire surface complete all as specified and directed.
42M&L for preparation of old decorated plastered or unplastered surfaces of walls and applying one coat of oil bound distemper Including cleaning of entire surface complete all as specified and directed.
43M&L for preparation of old decorated plastered or unplastered surfaces of walls and applying one coat of plastic emulsion paint Including cleaning of entire surface complete all as specified and directed.
44M&L for preparation of new plastered surafces of wall and applying two coats of water based preimum acrylic smooth exterior emulsion of approved colour complete all as specified and directed
45M&L for preparation of old plastered surafces of wall and applying two coats of water based preimum acrylic smooth exterior emulsion of approved colour complete all as specified and directed
46M&L for preparation of old plastered surafces of wall and applying one coat of water based preimum acrylic smooth exterior emulsion of approved colour complete all as specified and directed
47Dismantling, floor hearth or wall tiling inclduing cement mortar bedding and removing rubbish off the premises complete all as specified and directed.
48S&F exterior finish designer wall tiles, coloured, superior quality, not exc 1.00 Sqm each , 8-10mm thick as in wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
49S&F in repair aluminium composite panel sheet 3mm thick fixed with screws and necessary aluminium tube of size 25mm x 38mm x 1.5mm thick duly filled joints silicon as in ceiling, columns or making sign board with fixing steel letters complete all as specified and directed
50Excavation in trenches not exc 1.50 mtr wide and not exc 1.50 mtr depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc not exc 10 Sqm on plan and not exc 1.5 mtr in depth and getting out in soft/loose soil complete all as specified and directed.
51M&L for hard core of gauge not exc. 63mm of broken stone deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
52M&L sand cushion for paver blocks complete all as specified and directed.
53M&L for 80mm thick M-35 grade factory made cement concrete coloured interlocking paver block (yellow, red or both in combination) any shape and size conforming to IS 15658-2006 with grey cement and no pigment complete all as specified and directed.
54M&L for brick work with fly ash brick built in cement mortar (1:4) straight or curved on plan exc 6m mean radius for man holes complete all as specified.
55M&L for providing cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in coping on edges of tiles, rounded or chamfered on edges complete all as specified and directed.
56Removing of surplus excavated soil to a distance not exceeding 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point all as specified.
57Schedule of Credit (MINUS) Rs. 42,205.00 B/F from Serial Page No. [Note : Details of items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57739292
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 38.70 Lakhs
LAST DATE 17-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair Of Roof Top Of Bldg No P-11 At New Cantt And Constr Of Pathway Near Block No 1 Near Bldg No P-5 At Staging C , New Cantt Prayagraj
Basic Detail
Tender No 8973/E8
Bidding Type Tender
Location
City Prayagraj
State Uttar Pradesh
Key Dates
Publish Date 26 Sep 2026
Submission Date 17 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 38.70 Lakhs
Tender Fee 500
EMD 77400
Exemption Available
Document List
07978838-5308-46a6-b728-616981f9f66e.html
BOQ_887224.xls
TenderDocus_8973.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days