BOQ
| Sl. No. | Item Description |
| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (AF) SHILLONG ZONE, SHILLONG. Name of Work: CONSTRUCTION OF WATCH TOWERS AND OTHER SECURITY RELATED WORKS AT AFS TEZPUR Contract No: CE(AF)SZ/TEZ/ OF 2026-2027 File No: 88642/TEZ/E8 Bidder Name : PRICE SCHEDULE : BOQ(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SL No ITEM DESCRIPTION Item Code / Make QTY UNIT ESTIAMTED RATE Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE IN FIGURES TO BE ENTERED BY THE BIDDER RS. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT IN WORDS Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Sch 'A' Part-I (BUILDING WORK)Construction of integral Watch Tower with room in triple storey configuration with RCC framed structure with permanent specification complete all as specified and as shown in drawing. |
| 3 | Construction of Sub Guard Room with toilet in single storey configuration with RCC framed structure with permanent specification complete all as specified and as shown in drawing. |
| 4 | Construction of Waiting room with toilet cum bath in single storey configuration with RCC framed structure with permanent specification complete all as specified and as shown in drawing. |
| 5 | Construction of Store room in single storey configuration with RCC framed structure with permanent specification complete all as specified and as shown in drawing. |
| 6 | Total amount of Such 'A' Part-II (SITE CLEARENCE, SITE DEVELOPMENT AND EARTH WORK)Details of prepriced Schedule is given in tender documents |
| 7 | Total amount of Such 'A' Part-III (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents |
| 8 | Total amount of Such 'A' Part-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents |
| 9 | Total amount of Such 'A' Part-V (ROAD/PATH/CULVERT) Details of prepriced Schedule is given in tender documents |
| 10 | Total amount of Such 'A' Part-VI (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents |
| 11 | Total amount of Such 'A' Part-VII (SEWAGE DISPOSAL)Details of prepriced Schedule is given in tender documents |
| 12 | Total amount of Such 'A' Part-VIII (SECURITY WALL) Details of prepriced Schedule is given in tender documents |
| 13 | Total amount of Such 'A' Part-IX (RETAINING WALL) Details of prepriced Schedule is given in tender documents |
| 14 | Total amount of Such 'A' Part-X (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents |
| 15 | Total amount of Such 'A' Part-XI (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents |
| 16 | Total amount of Such 'A' Part-XII (VIEW CUTTER)Details of prepriced Schedule is given in tender documents |
| 17 | Total amount of Such 'A' Part-XIII (MS GRILL WORKS)Details of prepriced Schedule is given in tender documents |
| 18 | Total amount of Such 'A' Part-XIV (INCINERATOR)Details of prepriced Schedule is given in tender documents |
| 19 | Total amount of Such 'A' Part-XV (SHED OVER MAIN GATE & BOMB WAY GATE)Details of prepriced Schedule is given in tender documents |
| 20 | SCHEDULE \\"A\\" PART -XVI (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col.' F ' signifies this fact only. |
| 21 | INTERNAL ELECTRIFICATIONS & F of LED light fitting 2 feet, 1X10 W, 220 V AC, batten features a durable extruded aluminium body with a high quality PC diffuser for uniform illumination with slim integrated design ensurers easy installation, with efficacy (> 120 Lm/W) optional enhance energy efficiency including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 22 | INTERNAL WATER SUPPLYS&F of brass Angle stop cock CP fancy type (Matching with Bib tap and pillar cock) high pressure with capstan head long sunk screwed down 15mm dia bore, complete all as specified and as directed. |
| 23 | Bringing approved earth for Roads/Path/Culvert and Retaining WallBringing approved earth from outside MOD land, distance beyond 5 KM but not exc 10 KM and depositing, levelling, rolling and compacting complete all as specifed and as directed. |
| 24 | SEWAGE DISPOSALM&L for construction of septic tank 10 users capacity including excavation in soft/loose soil, foundation in PCC (1:2:4) Brick work in CM (1:4), RCC slab cover including RCC precast manholes cover having 6mm plate embedded all around / fibre re-inforced cover with angle iron frame vent saft and sludge chamber etc complete all as shown on TD drawings and all as specified and as directed. |
| 25 | M&L for Soakage Wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonary with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia x 3 M efefctive depth complete all as shown on TD drawings and all as specified and as directed. |
| 26 | SECURITY WALLS&F of Concertina coil (reinforced punched barbed tape single layer) for fencing work complete all as per following specification and as directed : (i) Diameter of concertina coil: 1050 mm (ii) Number of turns in concertina : 50 to 53 turns (iii) weight to each coil : 15 kg (Approx) (iv) Coverage per coil : 6 RM (v) Central core wire : Made from high tensile spring steel core wire conforming to IS-4454 dut hot dipped galvanished ( conforming to IS-2629) with dia 2.59 mm (+/- 5%), UTS 145-160 Kg/Sqmm, Zinc Coating 250-300 gms/Sqm (vi) Strips : Electro galvanished steel strip 0.5 mm (+/- 0.02 mm) thick conforming to IS-1573, Zinc coating- 120 gm/ Sqm and bituminished dipped, width or barbs 11 mm (+/- 5%), pitch of barbs 24 mm (=/- 0.5 mm) (vii) Clips : AISI 304-1.5 mm thick C and U clips 'C' Special type for fixing coil and RBT wire, 'U' clips special type for joining one coil to another coil and RBT wire to RBT wire jointing (viii) No of clips 125 for each coil (ix) handle and spikes to be provided as required complete all as specified and as directed. |
| 27 | RETAINING WALLSupply only 80 mm dia PVC (HDPE) pipe for weep hole complete all as specified and as directed. |
| 28 | EXTERNAL WATER SUPPLYM&L for reconstruction of brick masonry valve pit of size 90cm x 90cm x 90cm (internal dimension) with one brick thick PCC 1:4:8 type D-2 (using 20mm graded crashed stone aggregate) as in foundation concrete incl PCC (1:3:6) type Cl (using 20mm graded crashed stone aggregate) as in bedding and coping 10mm thick cement plaster in Cement mortar (1:4) internally & externally upto 15cm below ground level providing valve pit 50x50x6mm angle iron frame all round the fixed point by means of 4 Nos hold fast 150mm long made out of flat iron 40 x 6 mm embedded in PCC block (1:2:4) type B-I (using 20mm graded crashed stone aggregate) of size 230 x 200 x 100mm incl provn of hing welded with angle iron frame and Mild Steel cover 3mm thick, Mild steel handle of suitable and size welded with Mild steel cover & suitable locking arrangement & applying two coats of synthetic enamel paint over a coat of red-oxide primer incl necessary excavation work in soft/loss soil complete all as specified and as directed. |
| 29 | EXTERNAL ELECTRIFICATIONM&L for brick sub class B locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and as directed. |
| 30 | Supply & fixing of 1x1000W HPSV, Weather Proof, manualy operated 360 degree rotable as well as 45 degree tilting arrangement, sealed with range of minimum 700m, carbon aluminium alloyed body, mirror back glass reflector with SS side reflector, toughend front clear glass scaled with neoprene gasket, fireproof ceramic lamp holder, control gear, locking arrangement, lamp holder etc. along with under deck control arrangement. search light shall be fitted on roof of the watch tower at a height of 1 meter and suitable length of operating handle shall be provided for easy operation from the watch tower cabin below the roof. Gunmetal bushes, SS hardware shall be used. Metal parts shall be powder coatde. The search light shall be suitable for outdoor installation with IP:65 degree protection and type tested by NABL approved Govt. Testing Laboratory as per relevant IS, complete all as specified and as directed. |
| 31 | S&F cable junction box 155 x 210 x 92mm in size, made out of thermoplastic sheet having IP 66/69 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-Nos) fixed on poles with flat aluminium strip clamps of size 25 x3mm, nuts, bolts, washers etc complete all as specified and as directed. |
| 32 | S&F of cubical housing cabinet type LT feeder pillor box outdoor type, platform mounted factory made, totally enclosed dust and vermin proof openable from both front and rear side made out of 3.15mm thick CRCA MS Sheet of overall size 1000 mm (height) x 1000 mm(width) x 600 mm (depth) and built upon suitable size angle iron frame work , having front and rear hinged doors,GI earthing strips at rear side , bottom detachable gland plate complete with suitable size zinc plated and passivated nut, bolts , spring and washers. The cabinet and all members should be chemically treated with MSR solution for anticorrosive treatment and apply powder coated paint (RAL-7032) The panel should be suitable for 415 volts , 50Hz, 3 phase 4 wire system and internal connection should be provided with aluminium strips of suitable size and necessary foundation work and comprising following:- (Feeder Pillar No. 01)BUS BAR CHAMBER(a) Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TP&N solid aluminium bus bars, rated 200 amps supported at required intervals sleeved with heat shrinkable PVC sleevings. The bars shall be colour coded at required intervals for identification - SET OF 4, 1 No. INCOMER (a) MCCB of 4 pole of capacity 40 amps with breaking capacity of 16 KA (Thermal setting 100%, Magnetic setting upto 70%) |
| 33 | M&L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for pipe upto 100mm dia suitable for 0.4 mpa working pressure complete all as specified and as directed. |
| 34 | Earthing for internal and external electrification M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x 6mm thick electrode and 4 mm dia galvanised iron wire as earthing lead buried directly in ground vertically (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to GI wire 4mm dia as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connected to board / panel test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type B1 cover slab 50cm x 50cm x 5cm reinforced with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 18mm GI tubing light grade for protection, test point, testing on completion all as shown in Electrical Plate No 3 of SSR Part-I (2009) complete all as specified and as directed. |
| 35 | Material and labour for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not ness than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth late surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32 x 6mm dia by means of bolts, nuts, check-nuts and wahsers of galvanized iron pipe light grade with funnel and wire mesh complete including excavation and earth work, RCC chamber and cover in cement concrete 1:2:4 type C-1 using 20mm graded stone aggregate etc all as specified and shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion and directed complete all as specified and as directed. |
| 36 | Note:- Schedule of credit (Sch 'A' Part- XVII) amount of Rs 49,542.50 shall be deducted from the total quoted amount of BOQ. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 23 daysNov 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender