Tender For special Repair/ Replacement Of Dg Set & Servo Voltage Stabalizer Against Ber And Provn Of Two Sets Of 03 X Three Phase Power Supply Points With Earthing For Charging Of special Veh At Nams (3Rd Call)
Tender Value
41.89 Lakhs
Estimated cost
Bid Submission
10 Oct 2026
6 days left
EMD
83780
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
S.a.s Nagar → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair/ Replacement Of Dg Set & Servo Voltage Stabalizer Against Ber And Provn Of Two Sets Of 03 X Three Phase Power Supply Points With Earthing For Charging Of special Veh At Nams (3Rd Call)
BOQ
| Sl. No. | Item Description |
| 1 | Supply,installation, commissioning & testing of ECO friendly silent Diesel engine driven generating set against BER 250 KVA/200 KW output AC 415 volts 3 Phase 4 wire, 0.8 PF at NTP, speed 1500 RPM mounted on common base plate with flexible coupling and meeting the requirments of IS-4722/BIS -5514 specification with CPCB IV+ approved accoustic enclosure fabrictaed out CRCA sheet 2 mm thick and structual sheet metal base frame. Sound proofing of enclosure is done with high quality foam confirming to IS 8183 of 25 mm thickness and denasity 30 kg/M3 complete including PCC foundation in all respect complete as per manufactures recommendations:(a) Diesel Engine : Water cooled diesel engine of adequate capacity at 1500 RPM generally in accordance with latest BIS/IS specification, self starting including 01x12 Volts maintenance free battery of suitable capacity, charging dynamo/ alternator, air cleaner and all standard fitting/fixtures as per Manufacturing practice including. The engine shall be capable to take 10% extra overload for one hour for every 12 hours of running conforming to the environment (protection act 1986) ( 29 of 1986) and as amended vide Gazette of India notifications part -II Section -III sub section (I) dtaed 12 Jul 2004.(b) Engine Instructions Panel : All relevant information shall be displayed on a complete panel for easy monitoring of lubricant, Lub Oil temprature & pressure guages, water temprature guage, hours meter, starting switch etc & and Frequency meter (digital type) including safety automatic shut down in case of fault detection such as high water temp. low lubricattion on pressure, over speed and also including self starter alternator, cogged V belt, Fuel Tank with first fill of Lub Oil and Coolent (as applicable etc).(c) Fuel tank : In built fuel tank of adequate capacity with stop cock, drain plug and necessary fuel pipe complete as per manufactures recommendations. Fuel tank capacity not less then 12 Hours Run of DG set.(d) Alternator assembly :- Alternator assembly 250 KVA capacity AC 415/440 Volts, 3 phase 4 wire, 0.8 PF, 50 Hz, 1500 RPM, insulation class enclosure /SPDP self excited, self regulated brushless, complete with AVR with +-1% voltage regulation directly coupled to end match the above engine and confirming to relevant IS/BIS code as per latest manufacturing schedule. Please Enable Macros to View BoQ information |
| 2 | Supply,installation, commissioning & testing of ECO friendly silent Diesel engine driven generating set against BER 250 KVA/200 KW output AC 415 volts 3 Phase 4 wire, 0.8 PF at NTP, speed 1500 RPM mounted on common base plate with flexible coupling and meeting the requirments of IS-4722/BIS -5514 specification with CPCB IV+ approved accoustic enclosure fabrictaed out CRCA sheet 2 mm thick and structual sheet metal base frame. Sound proofing of enclosure is done with high quality foam confirming to IS 8183 of 25 mm thickness and denasity 30 kg/M3 complete including PCC foundation in all respect complete as per manufactures recommendations:(a) Diesel Engine : Water cooled diesel engine of adequate capacity at 1500 RPM generally in accordance with latest BIS/IS specification, self starting including 01x12 Volts maintenance free battery of suitable capacity, charging dynamo/ alternator, air cleaner and all standard fitting/fixtures as per Manufacturing practice including. The engine shall be capable to take 10% extra overload for one hour for every 12 hours of running conforming to the environment (protection act 1986) ( 29 of 1986) and as amended vide Gazette of India notifications part -II Section -III sub section (I) dtaed 12 Jul 2004.(b) Engine Instructions Panel : All relevant information shall be displayed on a complete panel for easy monitoring of lubricant, Lub Oil temprature & pressure guages, water temprature guage, hours meter, starting switch etc & and Frequency meter (digital type) including safety automatic shut down in case of fault detection such as high water temp. low lubricattion on pressure, over speed and also including self starter alternator, cogged V belt, Fuel Tank with first fill of Lub Oil and Coolent (as applicable etc).(c) Fuel tank : In built fuel tank of adequate capacity with stop cock, drain plug and necessary fuel pipe complete as per manufactures recommendations. Fuel tank capacity not less then 12 Hours Run of DG set.(d) Alternator assembly :- Alternator assembly 250 KVA capacity AC 415/440 Volts, 3 phase 4 wire, 0.8 PF, 50 Hz, 1500 RPM, insulation class enclosure /SPDP self excited, self regulated brushless, complete with AVR with +-1% voltage regulation directly coupled to end match the above engine and confirming to relevant IS/BIS code as per latest manufacturing schedule. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer