Defence Statutory Bodies & Commissions/Committees Closing in 5 days TDR #57739251

Tender For special Repair Of E/M Internal Electrification Work Of Bldg No P-92, P-100 And P-380A And Provision Of 04 X Standalone Air Heating System For 14 Weu At Oaf, Srinagar Under Ge 970 Ews

Issued by Statutory Bodies & Commissions/Committees · Budgam, Jammu and Kashmir
Tender Value
16.19 Lakhs
Estimated cost
Bid Submission
22 Oct 2026
5 days left
EMD
32500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair Of E/M Internal Electrification Work Of Bldg No P-92, P-100 And P-380A And Provision Of 04 X Standalone Air Heating System For 14 Weu At Oaf, Srinagar Under Ge 970 Ews

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Oct-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-Oct-2026

BOQ

Name of Work:- SPL REPAIR OF E/M INTERNAL ELECTRIFICATION WORK OF BLDG NO P-92, P-100 AND P-380A AND PROVISION OF 04 X STANDALONE AIR HEATING SYSTEM FOR 14 WEU AT OAF, SRINAGAR UNDER GE 970 EWS
Sl. No. Item Description
1Taking down carefully copper/aluminium point wiring from wooden battan/ conduits or from the wall by chasing/cutting (light, fan, socket or power) completely including (fittings such as switches, ceiling roses, pendants, regulator, sockets etc. to be measured separately) and making good disturbed surfaces of walls, floor etc.
2Taking down old MCCB,TPN DBs , SPN DBs,SP MCB & Main Switch/enclosure box of any make and type from the site and making good surface complete all as specified and directed.
3Taking down old submain wiring of any size and make from the site and making good surface complete all as specified and directed.
4M&L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor drawn through new PVC conduit 20 mm dia medium grade ISI marked and all conduit accessories concealed in walls/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLSH as earth continuty, fabricated branded modular metal flush box duly make embossed, concealed in walls with suitable modular cover plate for housing of mudular switches , socket out let and fan regulators etc, complete all as specified and as directed for the followings:- (a) One light/fan point controlled by one way switch.
5All as per Ser Item No 4.00 above, but one 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
6All as per Ser Item No 4.00 above, but Same board.
7M&L One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete (socket and switches to be measured and paid separately)
8M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing through PVC conduit/ Casing/Capping on Surface mounted FRLS, medium grade, ISI marked ,teRMinal box of 1.6 mm thick and 3 mm thick hylam sheet cover for teRMinal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following : (a) One light/fan point controlled by one by one way switch (switch to be measured and paid separtely)
9All as per Ser Item No 8.00 above, One 5 pin socket outlet 5 hole 5 Amp independent including PVC unsheathed copper conductor 1.5 Sqmm cable as earth wire connected to common earth and to earth dully socket & switches to be measured and paid separately.
10All as per Ser Item No 8.00 above, but Same board.
11M&L One power point with insulated stranded copper conductor cable 4 Sqmm single core and PVC insulated FRLS 1100 Volts unsheathed copper conductor 4 Sqmm stranded conductor as earth wire connected to dolly complete (socket and switches to be measured and paid separately)
12M&L Submain wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 volts grade in and including PVC conduit ISI marked alongwith one run of 6 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main DB and testing on completion etc complete all as directed.
13S&F in Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit/Casing Capping and conduit accessories on surface of walls complete all as specified and directed.
14M&L in replacement Modular switch, 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
15M&L in replacement Modular switch, 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
16M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
17M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
18M&L ceiling rose 3 phase PVC polycorbonate,isolated body.
19Supply and fix LED batten luminaire surface mounted T-8, 4 feet system wattage of not less than 20 Watts with lifetime of 25000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
20Supply and fix LED batten luminaire surface mounted 2 feet system wattage of not less than 10 watts and not less than 1000 lm with life time of 25000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, Class - 1, SDCM <5 short circuit and over circuit protection, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥80 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
21S&F 70 W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 80lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<20%, High and low protection along with a surge protection of 4 KV including provision of sutable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
22Supply and fixing Exhaust fan heavy duty 380 mm sweep (steel Body), 1250 RPM, metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
23S&F LED 2 X 2 ft backlite surface mounted fitting 36 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>80, color temperature >5700k, IP 20, Power factor<0.95, THD<10%, 50000 burning hours, Ambient temperature 0 to 500 DegC, Driver should meet IEC complaint for safety, with voltage variation range of 150-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed.
24S&F Electric water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank should be glass line coated complete all as specified of capacity 25 ltr having heating element up to 2 KW and not less than 5 star rating. Against def
25Supply and fixing Ventilating Fan 250 mm sweep, 900 RPM, non metallic resin body, single phase 230 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
26M&L for breaking old existing wall and making a provn for fixing of 300 mm sweep exhaust fan/250 mm fresh air fan including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed.
27Supply, installing, testing and commissioning factory made and tested LT Pannel Out door / Indoor type, platfoRM mounted of size: 800 X 200 X 1200 mm ( LxWxH ) suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic Copper bus bars of capacity 250 Amps rating installed on DMC insulators with bus bar chamber. The panel shall be dust and veRMin proof, IP-42 and made out of 2.00 mm thick CRCA mild steel sheet Wall mounted type, front opening type with aprons for cable entry, with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade complete all as specified and directed by Engineer-in-Charge. The scope of work also comprising of the following:- BUS BAR CHAMBER:- (a) 250 Amp TPN, Copper conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.INSTRUMENT CHAMBER:- (i) Volt Meter,96mm,flush type rated 0-500V, Digital type with Volt Meter selector switch- 01 Set. (ii) Amp Meter,96mm,flush type rated 0-200A, Digital type with suitable size C.T's, and Amp Selector switch- 01 Set (iii) RYB Phase indicating light LED type with MCB 2A SP C Series- 1 Set of three. INCOMING:- (i) MCCB 160 Amps 25 KA , 4 Pole with adjustable theRMal magnetic release=01 No., Make of MCCB:- Siemens / Legrand/ Schneider.OUTGOING:- (i) MCB 2 Pole 63 Amps, 415 volts , 50Hz, 10 KA = 02 Nos., Make of MCB:- Siemens/ Legrand/ Schneider. (ii) MCB 2 Pole 16 Amps, 415 volts , 50Hz, 10 KA = 01 Nos. , Make of MCB:- Siemens/ Legrand/ Schneider. (v) Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring minimum 10 Sqmm flexible.Note :- (i) Marking of Flat Nos on outgoing feeders of LT Panel. (ii) Time duration for replacement of LT Panel should not be more than 4 Hours. (iii) Rate quoted are deemed to be inclusive of all the fixture /fittings cater above
28M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below noRMal ground level, connected to galvanized iron strip 25x4 mm size as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 15mm bore for protection of G.I. strip from earth electrode to the earth test point of galvanized Iron/steel of size 75 x 75 x 25 mm, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe Med grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
29S&F MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar, neutral link earth link complete all as specified and directed.
30S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 220 volts, 50 Hz, 10KA breaking capacity complete all as specified and directed.
31Supply and fixing ceiling fans complete with blade, down rods, electronic regulator and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM BEE five star rated voltage range 140 - 280 volts power factor > .9 and THD < 20 % with brushess direct current motor (BLDC) all as specified and directed by Engr in Charge. Note : Hook & Down rods length should be as per site requirement. Against Def
32Supply and fix MCB DP 32-40 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge
33Supply and fix in MCCB 160 Amps, FP 415 volts 36 KA 50 HZ with theRMal magnetic setting complete all as specified and directed by Engineer in charge.
34Supply and fix MCB SP 5-32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge
35Taking down old unservicable cable of any size or type from any description (trenches, walls, ceilings., etc) from various locations, including any short length, all as specified & directed.
36Supply and Laying jointing & testing XLPE insulated PVC sheathed aRMoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade, cross sectional area 35 Sqmm 4 core complete fixed to floor/walls/ceiling with suitable size of clamp/saddles complete all as specified and directed.
37Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including foRMing bottom surface for laying of pipes complete all as specified and directed.
38Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
39Removal of excavated material to a distance not exc 50 Meter and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed.
40Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected
41Supplying, laying sub class 'B' bricks old size with axis of the bricks perpendicular to the axis of the cable as in cable protection complete all as specified and directed.
42Supply & Fixing in replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed
43Taking out/taking down old unserviceable damaged GI/PPR pipe of 25 mm external dia from trenches/Wall/roof including removing of fittings all as directed fby Engineer in Charge.
44Supply & Fix 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having theRMal stability for hot & cold water supply of external dia 25 mm including all PP-R plain & brass threaded Polypropylene random fittings, band, elbow, union,nipplesand short pieces fixed complete to walls, ceilings or in floors etc.
45M&L Lagging on pipes of internal dia upto 32 mm, used in external water supply or plumbing all round with, 40mm thick bonded mineral wool prefoRMed ‘SNAP ON’ pipe sections of density 144 Kg/Cum confoRMing to IS 9842, provided with chicken mesh wire netting 25 gauze 20mm mesh and finally covering with plaster of pairs , complete, all as specified and directed.
46Supply & Fix PP-R Gate valves (brass insert) ISI marked of external dia 25 mm as per requirement of the site and as directed by Engineer-in Charge.
47Supply and install, testing and commissioning of standalone ai heating system for space heating of hot air capacity of 35000 Kcal/Hr suitable for indoor operation with heat exchanger disel or kerosene and fuel filter, burner, blower fan, automatic digital temeparture controller, control panel with visual controls, safety interlocks, over load relay, timers, suitable capacity of fuel tank with following features:- (a) Bottom Flow (Hot Air release from bottom side of machine) (b) Control panels are double insulated (c) Burning chamber is made of flame resistant mild steel (d) Fully automatic operation (e) electronic control board is not effected high temperature (f) The monoblock body is insulated by the fiberglass and the exterior protection is secured against corrosin by powder painted sheet metal (g) Heat converting pipes are made of finest quality mild steel (h) Environmental friendly (j) Self diagnosis (k) Auto restart (k) Lock (l) Instant Heat (m) ExteRMe temperature controlling capabilities at minus at 50˚C with its improved heating capacity it heat easily at sub zero temperature. (n) Stablizer free operation (o) Heat output - 35000 Kcal/Hr (p) Hot Air Tempertaure :40˚C (q) Temperature rise :90˚C max (r) TheRMal efficiency :80-90% (s) Electric Supply :220Volt, 50 Hz (t) Temperature control : Automatic (u) Fuel type : Diesel / kerosen (v) Burner : Riello/Ben-ton. Make: SupertheRM/ WestheRM/TheRMax/ Top mind Industries.
48M&L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH confoRMing to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including PVC casing caping white colour with all accessories of same grade,surface on wall/ceiling including teRMinated in to Modular switch board / Cast iron/pressed steel teRMinal box 60mm deep of required size made out of 2mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switch socket combination 5 and 15 Amp flush type on the independent board complete all as specified and as directed.
49S&F Switch Socket combination multipurpose 5/16 Amps 5in 1 flush type complete.
50S&F DB with sheet metal enclosure 240 volts, 4 way with 200 Amp rated bus bar single pole & neutral double door type for MCBs including mounting work as required in position .complete all as specified and as directed
51Supply and fixing MCB SPN 40 amps 240 volts C curve, 50 HZ AC 10 KA
52M&L for Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below noRMal ground level) connected to GI wire 4 mm dia by mens of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-I Connected to earthing ten point all as specified and including necessary earth pit PCC 1:3:6 chanber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover , watering arrangement shall be made with GI pipe medium grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia upto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57739251
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 16.19 Lakhs
LAST DATE 22-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair Of E/M Internal Electrification Work Of Bldg No P-92, P-100 And P-380A And Provision Of 04 X Standalone Air Heating System For 14 Weu At Oaf, Srinagar Under Ge 970 Ews
Basic Detail
Tender No GE 970 EWS-77(T)/2026-27
Bidding Type Tender
Location
City Budgam
State Jammu and Kashmir
Key Dates
Publish Date 15 Oct 2026
Submission Date 22 Oct 2026
Open Date 24 Oct 2026
Finance
Tender Value 16.19 Lakhs
Tender Fee 500
EMD 32500
Exemption Available
Document List
1c45674f-5fd8-41ab-b510-15f60c5177a0.html
BOQ_887122.xls
Tender77T_merged.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 22, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 5 days
Oct 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Oct 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

1c45674f-5fd8-41ab-b510-15f60c5177a0.html

xls

BOQ_887122.xls

pdf

Tender77T_merged.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender