Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #57739247

Tender For Repair/Maint/Replacement Of Lt Oh Lines, Lt Ug Cables, Lt Panel, Feeder Pillar Boxes And Other Connected Items At Old C Area Under Ge Babina

Issued by Statutory Bodies & Commissions/Committees · Jhansi, Uttar Pradesh
Tender Value
47.91 Lakhs
Estimated cost
Bid Submission
17 Oct 2026
0 days left
EMD
95820
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jhansi → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair/Maint/Replacement Of Lt Oh Lines, Lt Ug Cables, Lt Panel, Feeder Pillar Boxes And Other Connected Items At Old C Area Under Ge Babina

BOQ

Name of Work:- REPAIR/MAINT/REPLACEMENT OF LT OH LINES, LT UG CABLES, LT PANEL, FEEDER PILLAR BOXES AND OTHER CONNECTED ITEMS AT OLD C AREA UNDER GE BABINA
Sl. No. Item Description
1Excavation in trenches in soft/loose soil not exc 1.5 mtrs wide and not exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed.
2Excavation in trenches in any type of soil not exc 1.5 mtr wide and exc 1.5 mtr in depth for laying of pipe/ cables/ poles etc and getting out complete all as specified and as directed.
3Returning filling in any type of soil including spreading leveling watering and well ramming in layers n.exc 25 cm complete all as specified and as directed.
4Removing excavated soils to a distance n.exc. 50 mtr and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and as directed.
5Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable incl spreading, levelling, watering and consiolidation complete all as specified and directed. Note:- Punned thickness of sand shall be measured for payment purpose
6Supply and laying PCC cable cover of size 250 x150 x 40 mm, laid in trench flat for protection of cable complete all as specified and directed by Engr in charge.
7Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 63mm, inner dia 50 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge.
8Material and labour for Double wall corrugated HDPE pipe,PN-10 ISI marked of outer dia 105 mm, inner dia 95 mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts including taking down of u/s existing HDPE pipes complete all as specified and directed by Engineer-in-Charge.
9M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in coping etc including form work for poles all as specified and directed by Engr-in-Charge.
10M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete for poles all as specified and directed by Engr-in-Charge.
11M&L for PCC 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete including form work for poles all as specified and directed by Engr-in-Charge.
12Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 300Sqmm 3.5 core as per IS:7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed.
13Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 240Sqmm 3.5 core as per IS: 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed. Havells/Paragon/SCI/Polycab/Plaza
14Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 150Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed.
15Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 120Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed.
16Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 70Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed.
17Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 50Sqmm 3.5 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed.
18Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 25Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed.
19Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 16Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed.
20Supply, laying and testing in repair/replcement of XLPE insulated cable, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) 1100V grade with multistranded aluminium conductor of size 10Sqmm 4 core as per IS 7092 Pt -I including connecting with suitable size of aluminium lugs/thimble and taking down old unservieable LT cable of any size complete all as specified and directed.
21Supply & fixing GI tube 50 mm bore light grade with all fittings for laid in trenches/fixed along with poles/walls & floor of buildings etc under crossing of road for protection of cables including demolition and taking down of the old existing pipe including repair of the floor/wall and matching with the existing surface if required complete as directed by Engineer-in-Charge.
22S & F and replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel sections including nuts & bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size and inclusive of one red oxide primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
23M&L for painting of steel tubuler 11/9 mtr poles any type complete including flat iron clamps, D clamps, Stay clamps, earth wire clamps, bracing, cross arm with two coat aluminium paint including prepration old painted surface initally & applying one coat of red oxide, applying two coat of aluminum paint over the red oxide, marking with alternate white and red strips 30 cm height 5 Nos strips with two coat of synthetic enamel paint (Ist quality of manufacturer )and also including numbering of poles with white paint are located on different locations complete all as specified and directed .
24M & L for cutting of road up to 0.75m deep suitable for laying underground cable/MS tubes of any size/dia including GI pipe of 50mm dia and making good the disturbed area to match with the existing level with cement concrete including removing the surplus soil to a distance upto 50mtrs complete all as specified and directed.
25Trimming of tree branches touching to over head lines, upto 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearence of HT/LT pole and sub station premises all as directed by Engg-in-charges. Note: (i) Trimming of all branches of trees falling under one span between two pole shall be shall be considered as as one span only. (ii) Contractor have to arrange all T&P , safty equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishapning occured due to negelency of safty aspects. Please Enable Macros to View BoQ information
26Trimming of tree branches touching to over head lines, upto 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearence of HT/LT pole and sub station premises all as directed by Engg-in-charges. Note: (i) Trimming of all branches of trees falling under one span between two pole shall be shall be considered as as one span only. (ii) Contractor have to arrange all T&P , safty equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishapning occured due to negelency of safty aspects. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57739247
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 47.91 Lakhs
LAST DATE 17-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maint/Replacement Of Lt Oh Lines, Lt Ug Cables, Lt Panel, Feeder Pillar Boxes And Other Connected Items At Old C Area Under Ge Babina
Basic Detail
Tender No 8577/E8
Bidding Type Tender
Location
City Jhansi
State Uttar Pradesh
Key Dates
Publish Date 26 Sep 2026
Submission Date 17 Oct 2026
Open Date 22 Oct 2026
Finance
Tender Value 47.91 Lakhs
Tender Fee 500
EMD 95820
Exemption Available
Document List
28021af2-b372-402b-8375-19fb81742a04.html
8577E8_CreditSchedule_1.pdf
8577Tenderdoc.pdf
BOQ_887175.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

28021af2-b372-402b-8375-19fb81742a04.html

pdf

8577E8_CreditSchedule_1.pdf

pdf

8577Tenderdoc.pdf

xls

BOQ_887175.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender