Tender For Repair/Replacement Of Internal Electric Wiring, Fittings, Fixtures And Connected Electrical Items At Otm Accn, Adm Accn, Tech Accn, Nursing College, Certain Messes, E/M Installation And Other Misc Area In Afmc Under Ge (Central) Pune
Tender Overview
Project Description
Tender for Repair/Replacement Of Internal Electric Wiring, Fittings, Fixtures And Connected Electrical Items At Otm Accn, Adm Accn, Tech Accn, Nursing College, Certain Messes, E/M Installation And Other Misc Area In Afmc Under Ge (Central) Pune
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old unserviceable/deteriorated batten/PVC conduit point wiring Aluminium/Copper from existing place i.e. light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets, bell push, ceiling rose, pendants, holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match/finish new surface as the existing surface either by using same colour distemper, putti or White/colour wash complete all as specified and directed. |
| 2 | M&L for concealed point wiring in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with Earth dolly and Bakelite laminated sheet ISI marked for fixing of switches/sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching/finishing of new surfaces either by means of plaster of Paris/putti or distemper/colour wash with same existing colour surfaces complete all as specified and directed.(a) One light/fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 3 | (b) One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 4 | (c) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 5 | (d) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horzintal plane. |
| 6 | All as per srl item No 2 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable as continuous Earth Lead complete all as specified and directed. |
| 7 | All as per srl item No 2 above but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 8 | M&L for concealed point wiring in wall and floor with necessary fixing arrangements with PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit including accessories/fittings such as junction boxes, bends, tee, elbow etc alongwith modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc including PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching/finishing of new surfaces either by means of plaster of Paris/putti or distemper/colour wash with same existing colour surfaces complete all as specified and directed.(a) One light/fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 9 | (b) One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 10 | (c) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 11 | (d) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 12 | All as per srl item No 8 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable as continuous Earth Lead complete all as specified and directed. |
| 13 | All as per srl item no 8 above but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 14 | M&L for surface point wiring on wall/ceilng with necessary fixing arrangements with PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia/PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of suitable thickness with Earth dolly and Bakelite laminated sheet ISI marked for fixing of switches/sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching/finishing of new surfaces either by means of plaster of Paris/putti or distemper/colour wash with same existing colour surfaces complete all as specified and directed.(a) One light/fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 15 | (b) One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 16 | (c) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 17 | (d) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 18 | All as per srl item No 14 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable as continuous Earth Lead complete all as specified and directed. |
| 19 | All as per srl item No 14 above but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 20 | M&L for surface point wiring on wall/ceiling with necessary fixing arrangements with PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic PVC conduit medium grade ISI marked not less than 20 mm dia/PVC Casing & Caping not less then (20 x 12 ) mm including all accessories/fittings such as junction boxes, bends, tee, elbow etc alongwith required size modular sunken boxes including modular frame and cover plate suitable for mounting switches/sockets etc including PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar and for matching/finishing of new surfaces either by means of plaster of Paris/putti or distemper/colour wash with same existing colour surfaces complete all as specified and directed.(a) One light/fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 21 | (b) One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 22 | (c) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 23 | (d) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 24 | All as per srl item No 20 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable as continuous Earth Lead complete all as specified and directed. |
| 25 | All as per srl item No 20 above but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 26 | Taking down old unserviceable/deteriorated point wiring Aluminium/Copper (excluding PVC conduit/casing & caping & GI/PVC switch box any type and size) from existing place for light light, fan, socket or power points complete with any type of unserviceable fittings such as switches, sockets, bell push, ceiling rose, pendants, holders sunken box, etc and making good all disturbed surface to wall, floor etc by means of cement mortar or plaster of Paris and to match/finish new surface as the existing surface either by using same colour distemper, putti or White/colour wash complete all as specified and directed. |
| 27 | M&L for drawing the wire in existing conduit steel/PVC casing & caping any type and size, complete with point wiring with PVC-FRLS insulated and unsheathed Copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade along with one single run of same size and type of Copper wire as continuous Earth wire to common Earth dolly in old existing sunken terminal boxes pressed MS/GI/PVC boxes of any type and size for mounting switch, socket etc along with screw and cup washers with all accessories and making good to disturbed surface with cement mortar and matching surface with existing White/colour wash, oil bound or cement base paint etc to match with existing surface complete all as specified and directed.(a) One light/fan/Bell point controlled by one switch 6/5 Amp one way single pole. |
| 28 | (b) One 3 pin socket outlet 6/5 Amps controlled by one switch on the same board with other switches. |
| 29 | (c) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board. |
| 30 | (d) One 3 pin 6/5 Amp socket outlet controlled by one switch independent board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 31 | All as per srl item No 27 above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable and 1.5 Sqmm PVC-FRLS insulated, unsheathed, Copper conductor, stranded 1100 volt grade cable as continuous Earth Lead complete all as specified and directed. |
| 32 | All as per srl item No 27 above but for One 3/5 pin 15 Amp socket outlet controlled by one switch indep board but below/side the switch board of light point in same vertical/horzintal plane complete all as specified and directed. |
| 33 | S&F in repair modular switch 6A SP one-way 230V White/Ivory or other approved colour complete all as specified and directed. |
| 34 | S&F in repair modular switch 16A SP one-way 230V White Ivory finish complete all as specified and directed. |
| 35 | S&F in repair modular socket outlet 2/3 pin 6 amps, multipurpose 2 module 230 Volts, White/Ivory or other approved colour single pole one way suitable for plug tops, complete all as specified and directed. |
| 36 | S&F in repair modular socket outlet 2/3 pin 16 amps, multipurpose 2 module 230 Volts, White/Ivory or other approved colour single pole one way suitable for plug tops, complete all as specified and directed. |
| 37 | S&F in repair modular type stepped electronic fan regulator, 80 watt, 230 V AC, 50 Hz complete all as specified & directed. |
| 38 | M&L in replacement for modular bell push, White/Ivory or other approved colour single pole, one way, 6 Amp suitable for 1 module complete all as specified & directed. |
| 39 | S&F in repair modular switch 6A SP two-way 230V White/Ivory or other approved colour finish complete all as specified & directed. |
| 40 | M&L in replacement for modular White/Ivory or other approved colour cover plate with frame and flush box for 1 to 4 Module complete all as specified & directed. |
| 41 | M&L in replacement for modular White/Ivory or other approved colour cover plate with frame and flush box for 6 to 12 module complete all as specified & directed. |
| 42 | S&F in replacement medium step type fan regulator 80 Watt, 240 Volt AC, socket size, medium step\\" ISI marked complete all as specified and directed. |
| 43 | S&F in replacement switch piano flush type (ISI marked), single pole, one way 6 Amp, 240 Volts complete all as specified and directed. |
| 44 | S&F in replacement switch piano flush type (ISI marked), single pole, one way 16/15 Amps, 240 Volts including complete all as specified and directed. |
| 45 | S&F in replacement socket outlet 3 pin, 6 Amp piano flush type including complete all as specified and directed. |
| 46 | S&F in replacement socket outlet, 2 in 1, 3/5 pin 6/16 Amp, piano flush type complete all as specified and directed. |
| 47 | S&F in replacement bell push 5/6 Amps SP flush type complete all as specified and directed. |
| 48 | S&F in replacement Ding dong sound door call bell electric AC 240 volt, 50 Hz ding dong type including taking down unserviceable complete all as specified and directed. |
| 49 | S&F in replacement Angle lamp/batten holder fixed on wall/ceiling complete all as specified and directed. |
| 50 | S&F in replacement ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and directed. |
| 51 | S&F in repair metal clad socket outlet with single pole and nuetral enclosure with two pin and Earth plug socket complete with one single pole MCB 20 Amps complete all as specified and directed. |
| 52 | S&F ceiling fan AC single phase 230 volts for size 1200 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable Copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV fan any type and size and deposited it in MES Store yard or complete all as spd and directed by the Engineer in Charge (EIC). |
| 53 | M&L in repair for sub main wiring with two single core 2.5 sqmm, 1100 volts grade, PVC insulated, stranded Copper conductor FRLS cable with continuous Copper Earth conductor of 2.5 sqmm in and including PVC conduit/Casing caping incl accessories complete all as specified and directed. Note:- (i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 2.5 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length. |
| 54 | M&L in repair for sub main wiring with two single core 4 sqmm, 1100 volts grade, PVC insulated, stranded Copper conductor FRLS cable with continuous Copper Earth conductor of 4 sqmm in and including PVC conduit/casing caping incl accessories complete all as specified and directed. Note:-(i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 4 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length. |
| 55 | M&L in repair for sub main wiring with two single core 6 sqmm and one core of 6 sqmm Earth wire, 1100volts FRLS grade, PVC insulated, stranded Copper conductor cable with continuous Copper Earth conductor in and including PVC Conduit/casing caping including accessaries complete all as specified and directed.Note:-Making good of disturbed surfaces will be done by contractor without any claims.(ii) 3 runs of 6 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length. |
| 56 | S&F in replacement of MCCB 63 Amps TP/FP16 KA with fixed thermal magnetic release frame F2 optim 1.0, 4 pole complete all as specified and directed. |
| 57 | S&F in replacement of 3 pin plug top 16A, White/Black 240V 3 pin top complete all as spd and directed. |
| 58 | S&F in repair LED Tube light fittings 18/20 W White/warm White surface and wall mounted LED batten, 6500K colour temparature. Soft & uniform light, instant start electronic driver efficiency >85%, complete including all accessories internally pre-wired in and including connecting up with twisted flexible Copper conductor cable of suitable size from ceiling rose to connector complete all as specified and directed. |
| 59 | S&F in replacement of LED light fittings 2'x2' of capacity 35/36 watts White/warm White LED surface/reccess environmental friendly, new genereation, aesthetically designed, ultra modern recess mounting luminaire with high brightness glare free soft illumination, White powder coated housing with LEDs, seamless front frame with flat White acrylic cover, 230 volts with all accessories internally pre wired and necessary mounting arrangements complete all as specified and directed. |
| 60 | S&F in replacement of surface/ceiling mounted with in-built driver, power factor > .9 operating voltage 230 V, round/square/rectangular shape 6 to 10 watts LED downlighter of White/neutral White/warm White color temperature, of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed. |
| 61 | S&F in replacement of surface/ceiling mounted with in-built driver, power factor > .9 operating voltage 230 V, round/square/rectangular shape 12 to 15 watts LED downlighter of White/neutral White/warm White color temperature, of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed. |
| 62 | S&F in replacement of surface/ceiling mounted with in-built driver, power factor > .9 operating voltage 230 V, round/square/rectangular shape 18 to 22 watts LED downlighter of White/neutral White/warm White color temperature, of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed. |
| 63 | S&F in repair LED street/building light with pressure die-cast housing along with prismatic polycarbonate diffuser and LEDs with secondary optics and IP 65 protection 30 watt complete with all accessories and wall mounting bracket of suitable size including clamps, nut bolts etc. prewired 3 core flexible wire complete all as specified directed. |
| 64 | S&F in replacement of LED light fitting surface and wall mounted LED batten with PVC housing & integrated electronic sensor complete in all respect of 10W cap complete all as specified and as directed |
| 65 | S&F in replacement of LED bulk head light fitting surface and wall mounted LED batten with complete in all respect and as per sample approved by EIC of 10W cap complete all as specified and as directed |
| 66 | Supply & fix as in repair electric storage water heater of capacity 25 Ltr, 230 V energy efficient complete all as specified and directed. |
| 67 | Man and material for removing of Stage lighting like COB/RGBW/Spot/Beam/flood light along with its connecting cable from a hight upto 12 Mtr by removing is all electricial/data cable connection along with connected accessories from light and its digital lighting console (management system) along with its power cable safely and handed it over to the AGE E/M store yard complete all as specified and directed. |
| 68 | S&F in replacement of COB light,operating voltage 230 V, round shape 9-12 watts LED downlighter of White/neutral White/warm White color temperature, of size as per site requirement etc along with 3 core prewired and all accessories complete all as specified and directed. |
| 69 | Man and Material for installation serviceable stage lighting like COB/RGBW/Spot/Beam/flood light at a hight upto 12 Mtr, securing necessary equipment for safely reaching heights of up to 12 meters, such as scaffolding or ladders deemed to be included in the job duly ensuring proper positioning and alignment of the light fitting, providing safe and secure electrical connections for each light fixture incl making any necessary extensions to the power cables and perform any cutting or taping work required. Connecting light to the digital lighting management system (console) as per the user's requirements. Ensuring the entire setup is safe, functional, and in line with the provided specifications. The entire job will be supervised by an authorized stage lighting technician, Each installed light will be provided with suitable ADDRESS to connect with spliter and console any type and make complete all as specified and directed. |
| 70 | Provide labor and materials for the replacement of the existing GI structure used for stage lighting of any type and size. The job involves dismantling the current structure and rearranging it using GI pipes, clamps, nuts, bolts, washers, and welding as required. The new structure will be fastened securely and grouted properly to ensure it can support the weight of the complete lighting system. The structure will be designed to hold the weight of approximately 35 or more stage lights like COB, RGBW, spotlights, beam lights, and floodlights etc. The job includes surface preparation, application of primer, and two coats of paint to protect the structure complete all as specified and directed. Note: All work will be carried out as per specifications and instructions provided by the Engineer in Charge (EIC). |
| 71 | Removal and Replacement of ceiling Lighting any type and size by providing labor and material from an existing ceiling lighting of any type and kind, including its connecting accessories, from a height of up to 12 meters. This includes disconnecting all electrical connections. Supply and install new downlights of any type and size in the existing false ceiling, ensuring proper connections and functionality as before. Securing the necessary equipment, such as scaffolding or ladders, for safely reaching heights up to 12 meters is included in the job. The contractor is responsible for the safety of all personnel and materials during the execution of the job. Any new or serviceable lights will be provided under their respective columns complete all as spd and directed by the Engineer in Charge (EIC). |
| 72 | Comprehensive maintenance of Stage Lighting Console (DMX 512 Compatible or any other model/make) by providing labor and materials for the upgradation, resetting, and reprogramming of a DMX 512 compatible stage lighting console. This includes configuring and integrating the system with a Digital DMX Splitter (HQ), ensuring compatibility and seamless communication between lighting fixtures. The job also involves Full integration of the DMX 512 console with the digital DMX splitter, the stage lighting console will be reprogrammed to ensure control of all lighting elements, any necessary firmware updates, software calibration, and system optimization to enhance performance. Note: The extra set of program backup will be provided. All work will be carried out according to the technical specifications complete all as specified and directed by the Engineer in Charge (EIC). |
| 73 | S&F exhaust fan AC single phase 230 volts for size 300 mm sweep, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable Copper wire from ceiling rose complete all as spd and directed inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC. |
| 74 | S&F exhaust fan AC single phase 230 volts for size 200 mm sweep Plastic body along with louvers, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable Copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC. |
| 75 | S&F exhaust fan AC single phase 230 volts for size 250 mm sweep plastic body along with louvers, including fixing arrangement including nut, bolts, washer etc, with necessary eletric connection with suitable Copper wire from ceiling rose complete all as spd and directed. inluding removing and dismentaling of old UNSV ex fan any type and size and deposited it in MES Store yard or as directed by EIC. |
| 76 | S&F in repair vertical 4 way TPN double door, recess mounted/wall mounted, MCCB as incomer and outgoing MCB SP/TP is 3 pole V-Tec of 100A rating & 16KA breaking capacity, MCCB is pre-fitted at factory & including price of MCCB complete all as spd and directed. (Note : Empty space shall be covered by blanking plate and connect with lugs without any extra cost ) |
| 77 | S&F in repair MCB TPN DB 4 way double door with 200 amps rated busbar 415 V, complete all as specified and directed. |
| 78 | Supply & fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type Copper bus bar, Din rail, Earth bar of 8 way complete all as specified and directed. |
| 79 | Supply & fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type Copper bus bar, Din rail, Earth bar of 12 way complete all as specified and directed. |
| 80 | Supply & fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type Copper bus bar, Din rail, Earth bar of 4 way complete all as specified and directed. |
| 81 | Supply & fixing in replacement of DB by SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type Copper bus bar, Din rail, Earth bar of 2 way complete all as specified and directed. |
| 82 | S&F in replacement of MCCB 100 Amps TP/FP16 KA with fixed thermal magnetic release frame F2 optim 1.0, 4 pole complete all as specified and directed. |
| 83 | S&F in replacement MCB SPN, 5 to 40 Amps 240 volts, AC, 10 KA breaking capacity 'C' Series, complete all as specified and directed. |
| 84 | S&F in replacement MCB SP, 06 to 40 Amps 240 volts, AC, 10 KA breaking capacity 'C' Series,\\"ISI marked complete all as specified and directed. |
| 85 | S&F in replacement of MCB TPN, 63 Amps 415 volts, AC, 10 KA breaking capacity 'C' Series,\\"ISI marked and complete all as specified and directed. |
| 86 | S&F in replacement of MCB Tripple pole of rated capacity 40/63 amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified and directed. |
| 87 | Material and labour to perform core drilling on brick/masonry walls with a thickness of up to 18 inches, drilling shall crate holes with a diameter ranging from 2 to 4 inches, using suitable machinery and equipment. The contractor shall provide all necessary materials, labour, and eqpt reqd to perform the work. The contractor shall ensure that the drilling prices is executed without damaging the surrounding structure, any scaffolding, ladders, or additional support structures necessary to perform the job shall be arranged by the contractor under the job complete all as spd and directed by the EIC. |
| 88 | M&L in in replacement for earthing with galvanised steel Earth plate electrode 60cmx60cmx 6.3 mm buried directly in ground Earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and incl GI wire 4 mm dia and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing Lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover and MS angle iron frame, watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit incl excavation and Earth work in any type of soil and testing on completion etc complete all as specified and directed. (NOTE:-GI Earth wire and protection pipe beyond 7.5m will be measured and paid separately) |
| 89 | M&L in replacement for earthing with GI Electrode 3 Mtr long consist of GI pipe outer dia 76mm and GI pipe inner dia 32mm, inner space should be compacted with dry chemical compound for enhancing conductivity all including boring installation, transportaion, concrete pit including excavation and Earth work in any type of soil and sufficient quantity of ground enhancing backfil compound testing of soil condition, PVC pit cover and GI strip 32 x 6mm up to 7.5 Mtrs long etc and testing on completion etc complete all as specified and directed. |
| 90 | S&F in repair service connection with twin core 10 Sqmm 240 volt heavy duty un armured PVC insulated solid Aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connection in replacement of old unseriveable conductor cable complete all as specified and directed. |
| 91 | S&F in repair service connection with twin core 6 Sqmm 240 volt heavy duty un armured PVC insulated solid Aluminium conductor cable served with inner sheathing of PVC tape and overall PVC sheathed in service connectionin replacement of old unseriveable conductor cable complete all as specified and directed. |
| 92 | S&F in replacement of old sketch fitting/any type by decorative wall mounted LED lamp (White/warm) complete all as specified and directed. |
| 93 | Comprehensive maintenance of Fasad Lighting system consisting of RGBW liner LED wall washer luminaire, M15 female connector, M15, extension connector, CS junction box 3 way, DMX controller system expandable from 2 to 4 DMX 512 universes by providing technician labour and routine maintenance materials for the upgradation, resetting, and reprogramming of a DMX 512 compatible Facade lighting . The job also involves Full integration of the DMX 512 console with all the Fasad lights and its connected assessories. All work will be carried out according to the technical specifications and as directed by the Engineer in Charge (EIC). |
| 94 | S&F in replacement of decorative wall mounted LED lamp (White/warm) for main gate complete all as specified and directed as per sample approved |
| 95 | Supply, installation, testing and commissioning of single phase energy meter, 50 Hz, 230 Vols, including necessary connection from DB to meter board complete along with removing old UNSV meter and deposit it to MES Store yard, complete all as specified and directed. |
| 96 | Supply, installation, testing and commissioning of three phase energy meter, 50 Hz, 440 Vols, including necessary connection from DB to meter board complete along with removing old UNSV meter and deposit it to MES Store yard, complete all as specified and directed. |
| 97 | Taking down old UNSV panel any type and shape/size and supply, installation, testing and commissioning as in replacement of indoor type LT panel board cubical with double door, floor mounted CPRI approved with MS angle iron base frame made out of 40x40x6mm angle, with angle iron Stand made out of 50x50x6 mm thick having 4 Nos legs of 2.5 feet height of size as required at site,grouted in PCC 1:3:6 type C-1 using 20 mm graded mechanically crushed stone aggregates for fixing panel board with and including necessary fixing arrangements,totally enclosed dust and vermin proof, front opening with locking arrangement, suitable for AC 415V, 3 phase, 50 Hz system, Red, Yellow, Blue and Black coloured insulated Aluminium bus bar of suitable size to carry 450 amps four Nos of suitable length and internal wiring with aluminum strip of suitable size duly painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer of any tint and marking wiring circuits, complete all as specified and directed.duly comprising of the following accessories inclusive of MCCBs Spreder,Terminals Kit, nut, bolt and washers, handle and any other assessories required for its connection and operation etc complete all as specified and direced by EIC :-(a) Voltmeter flush mounted 0-400 V square digital type-01 No.(b) Ammeter flush mounted 0-400 A, CTs operated, square digital type-01 Nos.(c) Phase indicating lamp set (RYB) industrial LED type-01 Set. (d) MCCB, AC, 415 Volt, 250 Amps breaking capacity 36 kA at 415 volt, 4 pole (Adjustable Thermal & Adjustable Magnetic-01 Nos (f) MCCB, AC, 415 Volt, 63 Amps breaking capacity 25 kA at 415 volt, 4 pole (Adjustable thermal & Fixed magnetic)-04 Nos |
| 98 | M&L for Servicing/testing of Metering indoor building Panels, 03/01 Phase, 415/230 Volts complete all as specified and directed.(i) Repair/replacement of damaged hinges and locks/latches of each compartment.(ii) Cleaning of existing bus bars with CTC applying with red solution, providing bus bar insulation & refixing with new nuts/bolts/washers etc.(iii) Replacement of damaged Copper cable and fixing new Copper cable for incoming and outgoing connections of each MCCB/MCBs switches, terminals to bus bars including connector.(iv) Replacement of damaged cable protection pipe and damaged/wornout cable lugs of any size for incoming & outgoing cables(v) Replacement of neoprene gasket and transparent acrylic sheet 3 mm for all doors of panel board.(vi) Repainting of panels after removing the rusting, scrapping, cleaning and drying the surfaces complete.(vii) Running welding wherever required(viii) Replacement of unsv MCCB/MCBs.(MCCB/MCB shall be measured & Paid separately)(ix) Removing, cleaning and refixing of elctric meter including connection of concerned accn complete |
| 99 | M&L in repair for sub main wiring with two single core 1.5 sqmm,1100 volts grade, PVC insulated, stranded Copper conductor FRLS cable with continuous Copper Earth conductor of 1.5 sqmm in and including PVC conduit/Casing caping incl accessories complete all as specified and directed. Note:-(i) Making good of disturbed surfaces will be done by contractor without any claims. (ii) 3 runs of 1.5 Sqmm conductor and one run of PVC conduit/casing caping shall be measured as one unit length.Note for all above :-(a) Contractor/his rep/his electrician will attend the complaint cell perodically all as directed by EIC, any ladder/eqpt/necessary electrical tools to check and troubleshoot electrical complaints for various location of AFMC is all inclusive .(b) Complaint related to no lights, replacing of switches, sockets,, replacing burnt MCB, short circuit, voltage fluctuation due to internal wiring, repair to faulty earthing etc will be attended within 8 hour of raising complaint.(c) The complaint can be registered Telephonic/complaint slip, WhatsApp and any other mode of communication. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender