Tender For Conservation, Renovation And Restoration Of Office Main Building At Shf Kanyakumari
Tender Value
46.66 Lakhs
Estimated cost
Bid Submission
14 Oct 2026
11 days left
EMD
47000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kanniyakumari → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Conservation, Renovation And Restoration Of Office Main Building At Shf Kanyakumari
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling Flat & Pan Tiles or Mangalore Tiles over Flat Tiles without roof timbers |
| 2 | Dismantling Wrought & Putup framed timbers in roofs/floors rafter |
| 3 | Dismantling Country wood false ceiling |
| 4 | Dismantling Plain Cement Concrete |
| 5 | Dismantling Brick masonry in Cement mortar walls under 3m high |
| 6 | Clean removal of Cement Plaster from walls |
| 7 | Dismantling RCC by manual/ by using deploying machineries |
| 8 | Thorough scrapping of old plastered surface |
| 9 | Doors and windows including removal of frames, hinges and fastenings |
| 10 | Earthwork excavation and depositing on the bank with initial lead and lift of 10 metres and initial lift of 2 metres in hard stiff clay stiff block cotton hard red earth murram, gravel stoney earth and earth mixed with small size boulders and hard gravelly soils (SS 20B) etc., compete as per standard specification - 1 Cum for Drainage |
| 11 | Supply, collection and filling of Gravel from approved quarry including all cost and conveyance to site, stacking them on road side to departmental gauge for the take premeasurement. Each layer not more than 15cm thick and consolidation properly etc complete. |
| 12 | Cement concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15cm thick well rammed, consolidated and including curing etc., complete complying with standard specification and as directed by the departmental officers. - Mixing by Manual means |
| 13 | Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 8 3/4\\" x 4 1/4\\" x 2 3/4\\" with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. |
| 14 | In Cement Mortar 1:5 |
| 15 | For Foundation and Basement |
| 16 | Brick partition walls of 11.50cm thickness using best quality Burnt Clay Brick of size 9\\" x 4 1/2\\" x 3\\" with class designation of 7.5 conforming to IS 1077-1992 in Cement Mortar 1:3 (One Cement and Three CS Sand) using hoop iron reinforcement if found necessary including Cost of Mortar Plasticizer, curing etc. complete complying with standard specification and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) |
| 17 | Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, Sill slabs etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid with silver oak joists of size 10cm x 5cm & 7.5cm x 5cm as support runner, vertical stiffener, side support and Top Horizontal stiffener spaced at about 60cm to 90cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). |
| 18 | Supplying and erecting centering for plane surfaces such as RCC Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks etc.. with necessary supports and strutting above 4.90m upto 5.50m height in all floors with all cross bracings using MS Sheets made of 10 gauge thickness welded with MS angle of Size 25mm x 25mm x 3mm for boarding laid over Steel adjustable Span of Size 2m x 2m(expandable upto 3.60m) and Silver Oak Joists of Size 10 x 5 cm spaced at 50cm to 60cm c/c and supported by Steel Adjustable Telescopic Props of Size 3.0 x 3.0m (expandable upto 5.50m) made with outer steel pipe with dia 50mm (3.60mm thick) and inner steel pipe with dia 40mm (2.90mm thick) Spaced at not more than 50 to 60cm c/c and with Cross bracings provided at two levels at a spacing of 1.80m etc complete complying with standard specifications. Steel adjustable span and Steel Adjustable telescopic props shall be provided as directed by the departmental Officers.(Payment for centering shall be given after the concrete is laid). |
| 19 | Reinforced Cement Concrete 1:1-1/2:3 (One Cement, One and a half crushed stone sand and Three hard broken stone jelly) using 20 mm gauge hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges centering and shuttering but including Super Plasticiser, mixing charges for machine mix,laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary and bearing surfaces of walls, beams etc. shall be finished smooth with Cement Mortar 1:3 (One Cement and Three Sand) and kraft paper laid over it without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers - machine mix |
| 20 | Foundation and Basement |
| 21 | For Ground floor |
| 22 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) |
| 23 | upto plinth/Basement level |
| 24 | Add Additional labour for works above plinth Basement level in every upper floor over the preceding floor or Below Ground level of every 3.50m depth |
| 25 | Supplying and fixing of Teakwood rafter etc complete complying with standard specification as per directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on work) |
| 26 | Supplying and fixing of Palmyrah rafter etc complete complying with standard specification as per directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on work) |
| 27 | Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 28 | Polishing the teak wood work with two coats of best French (Lac) polish with approved quality and brand over a coat of bee's waxing including preparing the wooden surface to receive polishing, etc., complete complying as per the standard specifications and as directed by the departmental officers. (The make, quality and colour of french polish, bees vax should be got approved by the Executive Engineer before use on works.) |
| 29 | Laying of roofing with Mangalore tiles over plain galvanised iron sheet 0.8mm (22 gauge) set in Teak wood reepers of size (50x12mm) using pollachi lime in all floors for Brick masonry band with mangalore tiles, including teak wood reepers of size (50x12mm) complete complying with standard specification as directed by the departmental officers. (The rate included the cost of all materials like Mangalore tiles, Galvanised sheet and labour charges for laying of Mangalore tiles with Galvanised sheet roof in Position) |
| 30 | Supplying and fixing of Ridge tiles etc., complete complying with standard specification and as directed by the departmental officers |
| 31 | Supplying and fixing T.W.false ceiling etc complete complying with standard specification and as directed by the departmental officers |
| 32 | Bordering with lime mortar 1:2 (one lime: two M.sand) etc., complying with standard specification and as directed by the department officers above roof |
| 33 | Providing and fixing eaves board of size 15cmx2cm made of TW with design as per standard specification |
| 34 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand) 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc, complete complying with standard specification and as directed by the departmental officers |
| 35 | New wall outer Plastering CM 1:5 12mm thick |
| 36 | New wall inner Plastering CM 1:5 12mm thick |
| 37 | Clean removal of Cement Plaster from walls |
| 38 | Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used, hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. |
| 39 | Making, Supplying and fixing of Panelled window shutter with Teak wood styles and rails of thickness of 0.04m both vertcal and horizontal and intermediate frames and the panels should be covered with 25mm thick Teak wood planks, all are to be done in the existing clues including labour charges for wrought put up and fixing the shutter in position with necessary furniture fittings such as Aluminium Butt hinges 125x30mm - 3 Nos Aluminium Hooks or eyes - 6\\" - 2 Nos and tower bolt 3\\" - 1 No including finishing the shutter with one coat of primer and finishing neatly etc complete complying with standard specification and as directed by the departmental officers |
| 40 | Supplying and fixing Mild steel grills for windows, ventilators etc., complete complying with standard specifications and as directed by the departmental officers |
| 41 | Solid PVC door shutters using 19 gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets. Shutter using 5mm thick solid PVC sheets for Panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mmx30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mmx30mm. The over all size of frames shall be 50mmx45mm with suitable rabate for housing the shutter. |
| 42 | Manufacturing, Supplying and fixing Precast Reinforced cement concrete slabs of following thickness in RCC 1:2:4 (one Cement, two crushed stone sand and four aggregates) using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers |
| 43 | Relaying of flooring with new athangudi tiles of size 25.4cmx 25.4cmx 1.90cm (10\\"x10\\"x3/4) with cement mortar 1:2 (one of cement and two of sand) base mortar over the existing slab/floor wherever necessary laying in position and pointing with cement mixed with colouring pigment at the rate of 0.3 kf/sqm etc complete complying with standard specification as per directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on work) |
| 44 | Flooring with following ceramic tiles of size 305x305x6mm laid over 20mm thick cement mortar 1:3 (one cement and three sand) base mortar over the existing slab/floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3kg/sq.m etc., complete complying with standard specification (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 45 | Dadooing walls with following best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick and pointing the joints with white cement mixed with colouring pigments at the rates of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 46 | Paving the floor with best approved quality fine polished Kota stone slabs of size 600 x 600 and above 20mm thick with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., complete complying with standard speicification and as directed by the departmental officers. (The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work) |
| 47 | Terrace flooring with Hydraulic pressed tiles of size 2020x2 cm laid in CM 1:3 (one cement and three sand) mixed with crude oil 10% by weight of cement and pointed with same oiled mortar etc |
| 48 | Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 49 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed Exterior (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 50 | Painting Old Plastered Wall Surface with Two finishing coats of ready mixed Interior (Emulsion) of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 51 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with “P” or “S” trap conforming to BIS with crushed stone sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 52 | Supplying and fixing in position Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works). |
| 53 | Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 54 | Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) |
| 55 | Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). |
| 56 | Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works). |
| 57 | Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap / Swan neck tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 58 | Supply and fixing PVC tank 1000 Litre capacity |
| 59 | Supply and fixing of gun gate valve -25mm |
| 60 | Supplying and fixing in position best quality 110mm PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 61 | PVC 110mm elbow |
| 62 | PVC 110mm door elbow |
| 63 | PVC 110mm Tee |
| 64 | PVC 110mm bend |
| 65 | PVC 110mm Y |
| 66 | Supplying, laying and jointing 25mm PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply above ground level. |
| 67 | For inlet pipe - 25mm |
| 68 | PVC 25mm dia coupler |
| 69 | PVC 25mm dia Elbow |
| 70 | PVC 25mm dia bend |
| 71 | PVC 25mm dia Tee |
| 72 | PVC 25mm dia End Cap |
| 73 | PVC 25mm x 20mm reducer |
| 74 | Supplying and fixing fine polished cuddapah slab of following thickness for cupboard arrangements including laying to correct alignment with necessary cement mortar and black powder etc., complete complying with standard specification and as directed by the departmental officers |
| 75 | Heavy Fiber Reinforced Polymer - FRP 5 Ton load capacity for high traffic and heavy duty application 600x600 mm manhole cover for chamber |
| 76 | Supply and fixing of Solid core Flush shtters with teakply on both side with teakwood lipping alround 35mm thick |
| 77 | Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive of giving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12\\"to a depth of 8\\" in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc |
| 78 | Wiring with 2x1.5sq.mm. PVC insulated unsheathed FRLSSC copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with PVC accessories with TW switch box with 5AFT switch in flush with wall covered with hylum sheet of 3mm thick with painting of suitable colour for open PVC light/ fanpoint (forelectronicregulator) (5pointspercoil) (SD 22) |
| 79 | Wiring with 2x1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5AFT switch with painting of suitable colour for open PVC light point / fan point (for electronic regulator) (6 points per coil) (SD 20) |
| 80 | Supply and fixing of 4 Feet LED 20W Fitting with LED 20W tube (Higher End complete with TW round blocks on wall or ceiling with PVC unsheathed FRLS Copper leads from terminals to the fitting (SD 443) |
| 81 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18\\") (SD 471) |
| 82 | Supply and fixing of WT bulk head fitting with guard suitable with 7W / 9W LED bulb (SD 84) |
| 83 | Supplyand fixing of 3Nos. 5A (3pin and 2pin combined flush type wall socket with control switches concealed in suitable TW box covered with hylem sheet in flush with wall with earth connection (for computer plug socket) (SD 142) |
| 84 | Supply and fixing of 5A/15A 3pin combined flush type wall socket with 15A flush type switch concealed in suitable MS box flush with wall with painting (SD 140) |
| 85 | Supply and fixingof 20A Flush type Wall Socket 32 ADP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) (SD 144) |
| 86 | Supply and fixing of 300mm (12\\") sweep (light duty) AC exhaust fan complete without provision of hole in the wall (SD 115) |
| 87 | Supply and fixing of light trap arrangements for 300mm (12\\") sweep (light duty) AC exhaust fan (SD 122) |
| 88 | Supply and fixing of 48W LED street light fitting with LED (Higher end) with 32mm dia. GI pipe (class B) with 1 no.32 mm dia GI bend complete on the existing post/ on wall with PVC unsheathed FRLS copper leads with MS clamps and with painting (SD 457) |
| 89 | Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 3 nos. 32A 3P MCB, 15 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End (SD 586) |
| 90 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 6 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End (SD 516) |
| 91 | Supply and fixing of sheet steel enclosure suitable for Double Pole MCB's with 32A DP MCB complete set in flush with wall with earth connection |
| 92 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. (SD 347) |
| 93 | Supply and run of 2 of 4 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4sq.mm copper wire with painting of suitable colour (SD 56) |
| 94 | Supply and run of 4 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable PVC rigid pipe on wall and ceiling with continuous earth Wire connection of 6 sq.mm copper wire with painting of suitable colour (SD 62) |
| 95 | Supply and run of 4 x 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V on 7/20 GI bearer wire for service connection mains (SD 68) |
| 96 | Supply and run of 4 x 6 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in 32mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron up right and end supports for mains (SD 73) |
| 97 | Supply and fixing of TNEB meter board suitable for 3 phase 63A service connection made up of suitable angle iron frame work of size 2 feet x1-1/2 feet using angle iron of size 1-1/2\\"x1-1/2\\"x1/4\\" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 63A fuse units (500V), 1No. neutral link, copper earth flatof size 1\\"x1/4\\"with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with 1No63 Amp 30 MA Four Pole RCD/RCCB (Lower End)with suitable necessary connection with earth connection complete (SD 132) |
| 98 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD 221) |
| 99 | Supply and Run of 1 of No.8 SWG copper wire for earth connection (SD 371) |
| 100 | GST at 18 percentage Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysOct 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender