Tender For Addition Alteration And Special Repair To Certain Otm Accommodation , Offrs, Jcos & Ors Md Accn At Umroi Mil Stn
Tender Value
9.07 Crore
Estimated cost
Bid Submission
27 Oct 2026
24 days left
EMD
7.78 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ri Bhoi → Meghalaya
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Addition Alteration And Special Repair To Certain Otm Accommodation , Offrs, Jcos & Ors Md Accn At Umroi Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish of the premises complete all as directed |
| 2 | Demoltion laid bedded and pointed in any mortar of Stone slabs and tiles of any description or thickness in floors, aprons etc |
| 3 | Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc, Brushing neat cement slurry with 3.0kg of cement per sq. metre ® complete all as specified and directed by Engr in charge. |
| 4 | M&L Vitrified Ceramic tiles 10 mm thick double charged (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm and not exc. 0.42 sqm as in floor etc to receive in floor, set over and including 15mm thick screed bed/bedding layer in CM 1:4 set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor make as a specified. |
| 5 | M&L Vitrified Ceramic tiles 10 mm thick double charged (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm and not exc. 0.42sqm as in skirting etc, set over and including 10 mm thick screed bed/bedding layer in CM 1:3 set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor make as a specified. |
| 6 | Material and labour for coloured non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqm as in floors over and including 15mm thick screed bed/bedding layer in CM 1:4 set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor make as a specified. |
| 7 | Material and labour for coloured non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.18 sqm but not exc 0.38 sqm as in skirting over and including 10mm thick rendering in CM 1:3 set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing surface make as a specified. |
| 8 | Material and labour for coloured Glazed ceramic tiles in vertical surface 300X450X 7mm/ 600x300x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl 10 mm thick rendering in CM 1:3 complete all as specified and directed. |
| 9 | Material and labour for coloured non skid ceramics tiles 7 to 8mm thick (square/ rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors over and including 15mm thick screed bed/bedding layer in CM 1:4 set and jointed in neat cement slurry and pointed in white/coloured cement to match the existing floor make as a specified. |
| 10 | M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed base 1:3 laid and jointed with grey cement slurry misxed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed |
| 11 | M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screedbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 20 mm thick backing coat in CM (1:4) complete all as specified and directed. |
| 12 | M & L for Green Marble work 18 to 20mm thick (table rubbed and pre polished) in steps (in single piece), jambs, pillars, windowcills,cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble over a screed bed/backing coat of 15mm thick cement mortar 1:6 complete all as specified and as directed. |
| 13 | Taking down chowkats or frames exc 1.50 sqm but n.exc 4.00 sqm with shutters (without taking off shutters from the frame) complete all as specified and directed. |
| 14 | Taking down chowkats or frames n' exc 1.50 sqm with shutters (without taking off shutters from the frame)complete all as specified and directed. |
| 15 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35 mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutterand fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer- In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) complete all as specified and directed. |
| 16 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) ®, complete all as specified and directed. |
| 17 | S&F With Particle Board core Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified.Note : The rate incl the cost of the builders hardware material indicated in the drg. |
| 18 | S&F Pressed steel frames of frame size 105x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specifiedNote : Filling of hollow of frames with PCC (1:3:6) type C1 shall be measured and paid seperately. |
| 19 | S&F Pressed steel frames of frame size 125x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specifiedNote : Filling of hollow of frames with PCC (1:3:6) type C1 shall be measured and paid seperately. |
| 20 | Material & labour PCC cast-in-situ type C1 1:3:6 (20 mm graded agg.) for filling of hollow frame complete all as specified and directed. |
| 21 | Material & labour PCC cast-in-situ type B0 1:2:4 (12.5mm graded agg.) for fixing hold fasts, angle etc complete all as specified and directed. |
| 22 | S&F 35 mm thick Factory made 2nd class hard wood plain framed panelled shutter (two panels ) with lock rail and panel of 9mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces . The size of rail and stile as per IS:1003(Part-I) , klin seasoned and chemically pressure treated complete all as specified and directed. |
| 23 | M&L second class hardwood Glazed and skeleton shutters 35 mm thick open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chemfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20 (a); for doors supplied and fitted to chowkats complete all as specified and directed. |
| 24 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified. |
| 25 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a primer of coat of red oxide all as specified. |
| 26 | S & F 100 mm medium weight stainless steel butt hinges and fixed complete all as specified and directed. |
| 27 | S & F stainless steel handles size 150mm complete all as specified and directed. |
| 28 | S & F stainless steel barrel tower bolt 200mm size of extruded section and fixed complete all as specified and directed. |
| 29 | S & F 300 mm long stainless steel sliding door bolt (Aldrop) assembly, comprising an extruded section stainless steel sliding bolt, hasp, staples (bolt type), and fixing clips manufactured from sheet, cast, or extruded stainless steel sections. fixed complete all as specified and directed. |
| 30 | S & F mild steel helical door spring 300mm long incl roller and roller plate complete all as specified and directed. |
| 31 | S&F 140mm Floor door stopper of aluminium alloy body and tongue, anodised with hard draw steel spring complete all as specified & directed.. |
| 32 | S & F stainless steel 06 pin cloth hooks/ hanger, for hanging cloths, towel etc. complete all as specified and directed. |
| 33 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm),Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drillingof holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. (Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) (A) Area not exceeding 2.00 sqm each |
| 34 | Supply and fixing factory made uPVC white colour fixed glazed window/ventilator made of (small series) frame 47 x 50 mm mullion 47 x 68 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area upto 0.75 sqm.) comprising of uPVC multi-chambered frame and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I. fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Glass shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. |
| 35 | M&L Powder coated aluminium(minimum thickness of powder coating 50 micron) work for doors,windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket , etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 36 | S & F powder coated aluminium window and ventilator shutters, sliding type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc (minimum thickness of powder coating 50 micron) complete all as specified and as directed by the Engineer-in-Charge. |
| 37 | M&L for aluminium anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge. complete all as specified and as directed. |
| 38 | Supply & Fix 4mm thick plain/tinted sheet glass, ordinary quality, glazing in square/rectangle each pan with oil putty or aluminium beads fixed to steel/ Aluminium etc, complete all as specified and as directed. |
| 39 | Supply & Fix 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.50 sqm each pan with oil putty or aluminium beads fixed to steel / Aluminium etc, complete all as specified and as directed. |
| 40 | S & F stainless steel wire cloth , 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as spd by engr-in-charge. |
| 41 | S & F in repair curtain rails, mild steel, chromium plated with fixing brackets, steps, rollers complete all as specified and directed by Engr in charge. |
| 42 | Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets |
| 43 | M&L for aluminium anodised snap grid frame work for false ceiling including hangers 6 mm dia GI wire up to 1200 mm length , adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long complete all as specified and as directed. |
| 44 | S&F PVC ceiling board of superior quality of size 600mm x 600mm x 5mm thick fixed in aluminium snap grid frame work including fixing accessories complete all as specified and as directed.Note: (I) Frame work shall be measured and paid separately under respective item. (II) Colour and design PVC ceiling board shall be approved by GE. |
| 45 | S & F 18 mm thick WPC ( wood plastic composite) board for cupboard and simillar work. The minimum wood percentage is not less than 20% of total weight and inclusive of 3mm thick laminated fixed with necessary adhesive material complete all as specified and directed by Eng-in-Charge. Note-(i) The rate inclusive of necessary builder hardware as per design/sanded engineering practice.(ii) The rate inclusive of dismanteling existing board and making good to be disturb surfaces complete all as specified and directed by Eng-in-Charge. |
| 46 | Material and Labour for water proofing treatment with water base polyurethane modified dispersion shall be carried out all as specified as under: -(a) Mechanical cleaning of surface to make it free from any bituminous residue / dirt. Oil and grease etc all as directed by GE / Engineer-in-Charge.(b) Cracks treatment by cutting open cracks and cleaning it from dirt loose materials etc and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE / Engineer-in-Charge.(c) Applying water based polyurethane modified dispersion (single component cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same material after dilution of water at 50% or specific primer matching same material as per manufacturer specification and as directed by GE / Engineer-in-Charge.Properties of polyurethane based chemical shall be as follows: (i) Highly elastic(ii) UV resistance(iii) Adhesion to concrete > 1N/Sqmm.(iv) Tensile strength - not less than 2.0N/Sq.mm for free film.(v) Elongation - not less than 300%.(vi) Solid content by weight - not less than 60%.(vii) Air / water permeability BSEN 12390 at 5 bar - 72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0mm.(viii) Accelerated weathering (ASTM 453): Pass 1000 hours.(ix) Reaction to fire - non inflammable.Note: (i) To be applied by the manufacturer's authorized applicator only. Contractor has to provide manufacturer's test certificate for the above mentioned technical parameters and purchase Vouchers.(ii) Removal of existing treatment to be paid separately.(iii) Roof top to be ensured to avoid water ponding.(iv) For accessible terrace and inaccessible terrace, 300mm height of vertical surface / parapet wall to be treated with same specification of slab. |
| 47 | Up rooting of tree from walls of bldgs up to extranded root and spraying of acid of required quantity complete from any location of Bldg up to 4 storied and making good disturbed surfaces with cement mortar (1:4) or cement concrete type C1(1:3:6) using 20mm graded aggregate including necessary scafolding complete for tree of girth up to 5 to 10 CM area exc 1 Sqm but n exc 2 Sqm complete all as specified and directed by Engr in charge. |
| 48 | Dismantling plain, semi corrugated or corrugated steel sheeting any gauge , thickness, including Nainital or similar pattern coverings. |
| 49 | S&F Pre- painted galvalume aluminum zinc coating PPGL based corrugated/Trapezoidal steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed. |
| 50 | S&F Pre- painted galvalume aluminum zinc coating PPGL based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, eave board, fixed with self tapping screws, complete all as specified and directed. |
| 51 | M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint all as specified. |
| 52 | Supply & Fix PPGL Eaves Board plain 0.5 mm thick and 225 mm wide ( V jointed to give 20mm laps) and including replace old decayed boarding & including cutting out old pieces and removing dismantling boarding, complete all as specified and directed.Note:-(a) Qouted rate deemed to be inclusive of scafolding work upto 14.00 meter ht. |
| 53 | Supply & Fix trapezoidal color coated PPGL rain gutter/ runner drop for rain water drain in bldgs of size not exceeding 150 mm with firmly attached downpout of suitable size discharging storm water into PVC SWR pipe of 110 mm dia including taking down old unservicable rain gutter and similar works etc complete all as specified and directed. Note: the rate shall be inclusive of downpouts, drop outlet, Elbow, End cap, Straight connecter, brackets, downspout couple, splash block, out site corner, clamps as required at site as per standared Engineering practice. |
| 54 | S&F sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mmbowl size 410mm x 330mm x 160mm complete all as specified and as directed. |
| 55 | Supply and fix in repair brass chroimum plated sink mixer for mixing hot and cold water screwed down CPVC SDR-11 Pipe of outer dia 20 mm complete all as specified and as directed. |
| 56 | Supply and fix in repair Steel plate rack made out of 0.63 mm thick stainless steel sheet of overall size 900x1219X250mm with providing necessary partition shelves & hanging arrangement etc as per manufacturer trade pattern as approved by GE and fixed to wall with wooden plug with brass chromium plated screws complete all as specified and as directed. |
| 57 | S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. including taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 58 | S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11 and fittings as in walls, ceiling, floor, etc. including taking up or down steel tubing 25 mm bore and connections including cleaning for refixing or removal to store complete all as specified. |
| 59 | Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 20 cm girth in brick walls etc complete. |
| 60 | S&F Vitreous china white wash down water closet including PVC seat cover and connection to drain or out going pipe and to flushing pipe anti-syphonage pipe etc, fixed as in repair, complete all as specified. |
| 61 | Supply and fix toilet paper holder with flat recessed type stainless steel Complete all asspecified and directed.\\" |
| 62 | S & F in repair Vitreous China squatting pan 'Orissa' pattern size 630x450 mm white with integral foot rests , incl connection to trap and flushing pipe, anti-syphonage pipe etc.comlete making good to floor ,any pattern (excluding flushing cistern |
| 63 | Supply and fix in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making Sconnections and fixed in position complete in all respect as specified. |
| 64 | S&F in repair PVC valve less syphonic action flushing cistern 10 ltrs capacity with inlet, ball valve, float and handle including bracket, PVC connection of 15 mm dia and 450 mm inclduing , white colour of approved make complete all as specified and directed. |
| 65 | S&F in repair wash hand basin, white flat back of size 550 x 400mm excluding piller taps but including waste cupling, PVC connection of 15 mm dia of length 600 mm, 32mm waste coupling and bracket etc complete all as specified and directed. |
| 66 | Supply and fix brass chroimum plated bottle traps for wash basins with inlet and outlet screwed for pipeor connections including necessary packing union and cap and fixed complete all as specified and as directed. |
| 67 | Supply and fix brass chroimum plated central hole basin for mixing hot and cold water screwed down CPVC SDR-11 Pipe of outer dia 20 mm complete all as specified and as directed. |
| 68 | Supply and fix in repair cabinet mirror of overall size 550x350x120 mm complete all as specified and as directed. |
| 69 | S & F Soap dish chromium plated of size not less than 100mm, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed |
| 70 | Supply and fix in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and as directed. |
| 71 | S & F in repairs Tubular towel rail brass chromium plated, 20mm dia, 60cm long between flanges |
| 72 | S&F in repairs Shower Rose 125mm size Chromium plated with swivel joints, any size, including fixing to steel pipe or union all as specified. |
| 73 | S&F stop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 74 | S&F stop valve/Angl cock 15 mm dia CP fancy type, with long shank and cup cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 75 | S&F in repair Bib taps ,15 mm bore long/short body,chromium plated with crutch or butterfly handle, screwed for iron pipe or for brass ferrule and fixed. |
| 76 | Supply and fix brass chroimum plated wall mixer for mixing hot and cold water screwed down CPVC SDR-11 Pipe of outer dia 20 mm complete all as specified and as directed. |
| 77 | S&F 1000 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical verticle with closed top) hoisted and fixed in position including taking down old one complete all as specified and directed. |
| 78 | S&F 500 ltrs capacity rotational moulded polyethylene water storage tanks (Cylindrical verticle with closed top) hoisted and fixed in position including taking down old one complete all as specified and directed. |
| 79 | S&F PVC ball valve 25 mm high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball serewed for iron pipe fixed in repair complete all as specified and directed. |
| 80 | Supply and fix 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 81 | Taking down soil pipe/ rainwater pipes (any size or pattern ) , including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing (measured overall as fixed along the centre line over fitting and ( accessories) complete all as specified and directed. |
| 82 | S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including scafolding etc complete. |
| 83 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including scafolding etc complete. |
| 84 | S&F for 110mm dia pvc bend with access door etc fixed with rubbr ring complete all as specified and directed. |
| 85 | S&F for 75mm dia pvc bend with access door etc fixed with rubbr ring complete all as specified and directed. |
| 86 | S&F for 110mm dia pvc Junction double (double T) equal of unequal with access door etc fixed with rubbr ring complete all as specified and directed. |
| 87 | S&F for 75 mm dia pvc Junction double (double T) equal of unequal with access door etc fixed with rubbr ring complete all as specified and directed. |
| 88 | S&F PVC(SWR) floor trap 75mm dia plain with grating incl jointing with solvent cement complete all as specified and directed. |
| 89 | S&F PVC(SWR) floor trap 110 mm dia plain with grating incl jointing with solvent cement complete all as specified and directed. |
| 90 | Supply and fix PVC(SWR) Vent Cowl for pipe 110 mm dia complete all as specified and as directed. |
| 91 | Supply and fix PVC(SWR) Vent Cowl for pipe 75 mm dia complete all as specified and as directed. |
| 92 | M&L for repair and rendering 10mm thick in cm 1 :3 on chajjas, facia, roof projection, column sides, beam bottom and sides including throating after removing cracked plaster and concrete including cleaning of viisible reinforcement and treating with cement slurry also necessary repair to cracked concrete if any with cement concrete 1:2:4 Type B-0 using 12.5mm graded aggregate including necessary scafolding work for double/single storey bldgs all as directed . |
| 93 | Demolition of cement concrete above ground floor and pavings exc 15 cm thickness (below or above ground level ) unreinforced complete all as directed. |
| 94 | M&L for PCC 1:5:10 Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floor complete all as specified and as directed by Engineer-in-charge. |
| 95 | M&L sunken treatment of Toilet/Bathroom as in following steps: i) Top of RCC slab in sunken portion including peripheral beams shall be plastered with 15mm thick in cement mortar 1 : 3 using approved water proofing compound @ 3% by weight of cement finished even and smooth using extra cement, curved at the junctions. ii) Apply two coats of epoxy resin/polymer modified cementations coating both on floor & beams. iii) Sunken slabs to be given 1:20 slope outward 25mm GI pipe spout with 300 mm projection beyond outer surface of wall shall be provided. iv) Water tightness of sunken portion to be tested by ponding with water for 72 hours. In case of even a slight mark of seepage, the portion to be treated and ponding shall be carried out again to confirm the water tightness of sunken slab. Note : No cutting in roof slab/beam shall be allowed for passing of CI pipes & fittings.The stage of water proofing to sunken slab shall be passed by Eng-in-charge/GE. |
| 96 | Excavating in trenches, n.exc 1.50 m wide & n.exc 1.5 m in depth; for foundation etc. or for shaft , wells , cesspits, manholes, piers holes, etc. n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/loose soil, complete all as specified and directed. |
| 97 | Returning filling in incl spreading, levelling watering and well ramming in layers not exc 25 cm thick in soft/loose soil, complete all as specified and directed. |
| 98 | Removing excavation material n.exc 50 m and depositing where directed at a level n.exc 1.50m above the starting point including spreading and levelling, complete all as Specified and directed. |
| 99 | Demolition and breaking up drain pipes 150mm bore (salt glazed ware, AC or reinforced concrete) set in CM, complete all as specified and directed. |
| 100 | Supply and laying of 150 mm Nominal diameter HDPE of pressure rating of PN 4 as per IS 14333:1996 for sewage line in any length laid in trench complete all as specified and as directed. |
| 101 | M&L for concrete bed to drain pipes including pakcing under and haunching against the sides of pipe after they are laid and tested in cement concrete 1:3:6 type C2 for 150 mm bore of pipe, complete all as specified and directed. |
| 102 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided, complete all as specified and directed. |
| 103 | M&L for precast RCC type B-1, 1:2:4 (using 20 mm graded aggregate ) as in cover slab set in CM 1:4 including necessary form work if reqd, complete all as specified and directed. |
| 104 | M&L for Mild steel TMT bars 6mm to 8 mm dia cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 105 | M&L for MS deformed or twisted round bars 10mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 106 | Removing demolished material upto a distance exceeding 250m but not exceeding 500m complete all as specified and directed. |
| 107 | Demolition of cement concrete(un-reinforced) concrte in ground floors and paving not exc 15cm thickness (below or ground level) not otherwise specifically provided for etc complete. |
| 108 | M&L for 75 mm thick cement concrete type C2 1:3:6 using 40 mm graded aggregate as in plinth protection finished fair and even with using extra cement complete all as directed. |
| 109 | M&L for cement concrete type C2 1:3:6 using 40 mm graded aggregate in surface channels and drains, complete all as specified and as directed. |
| 110 | M & L PCC 1:4:8 type D - 2 in foundation, filling and mass concrete (using 40 mm graded crushed stone aggregate) complete all as specified and as directed. |
| 111 | M&L for 50 mm Cement concrete type B-2, 1:2:4 (40mm graded aggregate) as in levelling concrete complete all as specified and as directed. |
| 112 | M & L for screed Bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed. |
| 113 | M & L Chequered cement concrete tiles 20cm x 20cm x 22mm thick, set, jointed and pointed in neat cement slurry in floors (over plinth protection) with grey cement and no pigments complete all as specified and as directed. |
| 114 | Demolition of precast concrete block built in cement mortar complete all as specified and as directed. |
| 115 | M&L for precast PCC 1:3:6 type C1 ( 20 mm graded aggregate ) block masonry with solid blocks, exc 10 cm in width and setting in CM 1:6 complete all as specified and as directed. |
| 116 | M&L for 15 mm thick rendering in CM (1:4) in two layers mixed with water liquid water proofing compound as per manufacture instruction in top layer 5 mm thick finishing the surfaces with fair an complete all as specified and as directed.d even without using extra cement |
| 117 | M&L for 15 mm thick rendering in CM (1:4) in two layers mixed with water liquid water proofing compound as per manufacture instruction in top layer 5 mm thick finishing the surfaces with fair and even without using extra cement including Taking down of cement plaster of any description including racking out joints for key scrubing with water complete all as specified and directed. |
| 118 | Supply only integral WPC ( Integral waterproofing liquid admixture for cement mortar) and application as per manufacture instruction all as specified and directed by Engr-in-charge. |
| 119 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered wall surface, all as specified and directed |
| 120 | M&L for rendering 10 mm thick in cement mortar (1:6) internal surfaces on fair faces of brick work or concrete surfaces,making finished even and smooth without extra cement including taking down of cement plaster complete all as specified and directed. |
| 121 | M&L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over one coat primer including wall care putty minimum 1.0 mm thick, complete all as specified and as directed. |
| 122 | Material and labour for 5 mm thick rendering in cement mortar (1:3) on fair faces of exposed/non exposed concrete surfaces such as soffits of slabs, chajja,fasia and simillar work including mixing & application integral water proofing compound as per manufacture instruction of finishing the surfaces fair and even including Taking down of cement plaster of any description including racking out joints for key scrubing with water complete all as specified and directed. . |
| 123 | Material and labour for three coats of white wash on newly plastered surfaces of ceiling including preparation of new plastered surafaces, complete all as specified and directed. |
| 124 | M&L for Preparing newly plastered surfaces of ceiling and applying two coats of distemper oil emulsion over one coat primer including wall care putty minimum 1.0 mm thick wherever reqd complete all as specified and as directed. |
| 125 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over over old surfaces including complete removal of existing treatment and Washing, rubbing down and stopping of distempered and painted surfaces |
| 126 | Washing rubbing down and stopping of distempered surfaces any type of wall incl preperation of old surface and then apply two coats over one coat primer of oil bound distemper of any tint with 1mm wall care putty where ever required & specified by Engineer -in-ChargeNote: wall putty shall be measured and paid separately |
| 127 | Washing rubbing down and stopping of distempered surfaces any type of ceiling incl preperation of old surface and then apply two coats of oil bound distemper over one coat primer of any tint with 1mm wall care putty where ever required & specified by Engineer -in-ChargeNote: wall putty shall be measured and paid separately |
| 128 | Material and labour complete preparation of old surface and apply two coats of white wash surfaces of ceiling including preparation of surafaces, complete all as specified and directed Engr-in-Charge. |
| 129 | M&L for 1mm thick internal wall putty on wall/ ceiling complete all as specified and directed |
| 130 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed |
| 131 | M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 132 | M&L in repair for 18 mm thick plywood grade BWR, type BB fixed with screws to timber frame work, block boards, grade 2 quality, interior grade, commercial type , fixed with screws to timber framed work for kitchen cabinet, cupboard etc ISI marked and as per IS 710, complete all as specified and directed. |
| 133 | M&L in repair for 12 mm thick plywood grade BWR, type BB fixed with screws to timber frame work, block boards, grade 2 quality, interior grade, commercial type , fixed with screws to timber framed work for kitchen cabinet, cupboard etc ISI marked and as per IS 710, complete all as specified and directed. |
| 134 | M&L for 0.9 mm thick decorative laminate type I, of surface finish, colour and pattern as approved , fixed with approved adhesive as per manufacturer,s instructions all as specified and directed. |
| 135 | S&F for 50 mm size butt brass hinges, heavy weight, cold rolled mild steel type E-11 all as specified and directed. |
| 136 | S&F Ball catches with 8 mm dia steel ball, and brass body and striking plate including letting in and fixed all as specified and directed. |
| 137 | S&F for 100 mm long,Brass handles , cast type , polished bright cupboard cabinet etc. all as specified and directed. |
| 138 | Provision of Modular Kitchen in officer qtr as per the following specification and enclosed drawing (a) Inside the cabinet unit i.e. CARCASS : Supply & fix 18mm thick BWR 710 graded marine ply, including ONE side covered with 1mm thick laminated sheets fixed with approved adhesive as per manufacturer's instructions on water proof plywoods, to be fixed as specified and directed (b) Cabinet SHUTTER : Supply & fix 18.0/19.0mm thick BIRCH PLY 710 graded for front shutter to be used as door shutter AND DRAWER SHUTTER, including both sides covered with 1mm thick laminated sheets fixed with approved adhesive as per manufacturer's instructions on water proof plywoods with 2.0mm thick PVC lipping (edge band) of MATCHING shade , to be fixed as specified and as directed.(c) Over Head unit : Supply & fix 18.0/19.0mm thick BWR 710 graded marine ply for Top, Side & shelves including both sides covered with 1MM thick laminated sheets with inclined provision to give handle less look fixed with approved adhesive as per manufacturer's instructions on water proof plywoods including pressing of lippings with 2.0 mm thick PVC lipping (edge band), to be fixed with good o crank hinges complete all as specified and as directed . WALL SHUTTER FINISH WITH PU PAINT GROVINGS. (d) handles incluuded of rustproof and well coated 15 pcs and other hardwares used for the installation . Note :(i) If any damages caused to the existing structure shall be made good without any cost (II) The rate shall be inclusive of dismantling of existing kitchen cabinet and similar work . |
| 139 | Supply and fix stainless steel elegant perforated cutlery basket 530 x 505 x 100. rustproof material equivalent price and specification in hettich/hafale all as specified and directed. |
| 140 | Supply and fix stainless steel elegant plain drawer/basket of size 530 x 505 x 200mm made of rust proof material equivalent price and specification in hettich/hafale all as specified and directed. |
| 141 | Supply & fix stainless steel imported dishrack 500 mm with drip tray for water collection equivalent price and specification in hettich/hafale all as specified and directed. |
| 142 | Supply & fix multipurpose holder for detergent and soap made of stainless steel. equivalent price and specification in hettich/hafale all as specified and directed. |
| 143 | Supply & fix tandem drawers metallic silver channels of weight 40 kg capacity soft closing with railing rods equivalent price and specification in hettich/hafale all as specified and directed. |
| 144 | Supply & fix stainless steel popular 3-tier pull out 180 x 505 x 585 for pull out cabinet, three tiers. equivalent price and specification in hettich/hafale all as specified and directed. |
| 145 | Supply & fix of stainless steel popular fixed 2-tier sink pull out 215 x 505 x 455 for pull out cabinet, two tiers. equivalent price and specification in hettich/hafale all as specified and directed. |
| 146 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing (Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) ®, complete all as specified and directed. |
| 147 | Providing and fixing 30mm thick FACTORY MADE BOTH SIDE PRELAM SOLID PANEL PVC DOOR SHUTTER consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles & 15x15mm for top & bottom rails. M.S. frame shall have a coat of metal primer of approved make and manufacture. M.S. frame shall be covered with heat moulded prelam 'C' channel made from 5mm (±0.25) thick Prelam Sheet of 600 kg/cum Density Manufactured by an ISO-9001-2015 certified Company, heat moulded Prelam PVC ‘C’ channel of size 30mm thickness, 70mm width out of which 50mm shall be flat and 20mm shall be tapered in 45˚ angle on either side forming stiles; and 5mm (±0.25) thick, 95mm wide Rajshri Prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45˚ on the inner side to form top and bottom rail and 115mm wide Prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tapered on both sides to form lock rail. Top, bottom and lock rail shall be provided either side of the panel. An additional 5mm (±0.25) thick PVC strip of 20mm width is to be stuck on the inner side of the ‘C’ Channel using PVC solvent cement adhesive . Panelling of 5mm (±0.25) thick both side prelam PVC Sheet to be fitted inside the M.S. Frame welded/sealed to the stiles & rails with 7mm (5mm (±0.25)+2mm) thick x 20mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive . 10mm (5mm (±0.25) x 2nos) thick, 20mm wide cross PVC sheet shall be provided as gap insert for top rail & bottom rail. .Door to be fixed to frame with 3 nos. S.S butt hinges of size 100mm * 25mm * 2mm and 32 mm long steel screws drilled suitable to pass through both the walls of the M.S tube . Other hardware’s should be fixed with 19*6mm size steel screws etc. Complete as per direction of Engineer-in-Charge, manufacturer’s specification & drawing. |
| 148 | Supply and fix factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and naturalfibers (wood powder/ rice husk/wheat husk) and nontoxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flameof Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as specified and directed. |
| 149 | Providing and fixing windows fabricated from rolled formed sections made of galvanized steel colour coated/ powder coated based steel as per IS 513 'D' quality galvanized as per IS 277 with zinc of 120 gms per sqm with total thickness of 0.06 mm. Paint pre painted section should be with primer coat of epoxy primer of 527 microns thick. Finish painted with polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns of powder coated with pure polyester powder up to 50-60 microns thick.The frame & mesh section shutter should be cut to length and mitred and joined with corner bracket made of polypropylene glass shutter shall be mitred and joined with corner bracket crca electroplated mullion using nylon mullion cap Ethyl Propylene Daimine Minomer (EPDM) gasket shall be used all around glass in shutter, between frame and glazed shutter and both side of fixed glass clip section shall be used around stainless steel fly mesh to fix mesh in mesh shutter.Each glazed shutter and mesh shutter shall be provided with SS pivot hinge set (02 nos) PVC handle 01 no, and 75 mm long alu powder coating peg stay 01 no. Glazed shutter and fixed glass portion shall be provided with glass of 4 mm thick glass. all window in toilet/bathroom/WC/ sanitary annexure shall be provided with finished grounded glass as specified. Fly proof shutter shall be provided with stainless steel 32 gauge fly mesh of 304 grade with 144 holes per sq inch. Window shall be provided with enamal painted grill made up of 10 mm sq bar 150 mm c/c sq bars should be horizontally fised to vertical flat of 6x12 mm at both ends grill.Windows frame shall be fixed to brick/ concrete masonry by using nylon self expansion caps and driving MS electroplated 100/ 75mm long screws in to the caps through frames. all screws shall be stainless steel complete all as specified and directedRef TD drg No. CESZ/2018/TD/35 (SHEET NO 1/2, 2/2) |
| 150 | Providing and fixing ventilators fabricated from rolled formed sections made of galvanized steel colour coated/ powder coated based steel as per IS 513 'D' quality galvanized as per IS 277 with zinc of 120 gms per sqm with total thickness of 0.06 mm. Paint pre painted section should be with primer coat of epoxy primer of 527 microns thick. Finish painted with polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns of powder coated with pure polyester powder up to 50-60 microns thick.The frame & mesh section shutter should be cut to length and mitred and joined with corner bracket made of polypropylene glass shutter shall be mitred and joined with corner bracket crca electroplated mullion using nylon mullion cap Ethyl Propylene Daimine Minomer (EPDM) gasket shall be used all around glass in shutter, between frame and glazed shutter and both side of fixed glass clip section shall be used around stainless steel fly mesh to fix mesh in mesh shutter.Each glazed shutter and mesh shutter shall be provided with SS pivot hinge set (02 nos) PVC handle 01 no, and 75 mm long alu powder coating peg stay 01 no. Glazed shutter and fixed glass portion shall be provided with glass of 4 mm thick pin head glass. all ventilator in toilet/bathroom/WC/ sanitary annexure shall be provided with finished grounded glass as specified. Fly proof shutter shall be provided with stainless steel 32 gauge fly mesh of 304 grade with 144 holes per sq inch. Window shall be provided with enamal painted grill made up of 10 mm sq bar 150 mm c/c sq bars should be horizontally fised to vertical flat of 6x12 mm at both ends grill.Windows frame shall be fixed to brick/ concrete masonry by using nylon self expansion caps and driving MS electroplated 100/ 75mm long screws in to the caps through frames. all screws shall be stainless steel complete all as specified and directedRef TD drg No. CESZ/2018/TD/35 (SHEET NO 1/2, 2/2) |
| 151 | Taking down and refixing existing steel window shutter( n.exe 1 sqm each) of any description incl cutting existing hinges and fixing box type hinges( two numbers per each leaf) incl necessary grinding, welding and fixing to the existing steel window frame complete all as specified and directed.Note:(i) The rate incl of two coat of synthetic enamel paint to window frame, incl priming of the welded portion.(ii) The rate incl of refixing of glass/ mesh reqd at site .(iii) Job work incl of taking down adn repair of existing window shutter having ( two glazed shutter and two Guazed shutter)(iv) Replacement of glass/ mesh to be measured and paid respective item in the schedule. |
| 152 | Hacking out old broken glass (any thickness, size, quality or description) from wooden/steel frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads |
| 153 | M & L for Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screedbase laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 10mm thick backing coat in CM (1:3) complete all as specified and directed. |
| 154 | M&L for machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed base 1:6 laid and jointed with grey cement slurry misxed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed |
| 155 | S&F in repairs 15 mm dia fancy type pillar tap cast copper alloy, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe & fixed. |
| 156 | S&F in repairs 15 mm dia stop valve, cast copper alloy, screwed down , high pressure with crutch butterfly handle, sacrewed both ends for iron pipe or for union & fixed. |
| 157 | Supply & Fixing in repairs vitreous china urinal half stall type white including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws pointing around urinal back in cement fixing only flushing cistern with brackets including waste pipe etc. |
| 158 | S/F in repairs vitreous china 580x440 mm,\\"ORISSA PATTERN\\" with 'P' or 'S' trap size squatting pan (Exclusive flushing cistern and flush pipe) incl foot rest complete and provision of lime concrete bedding. |
| 159 | Supply and fix Bathroom Mirror rectangular size(exc 1 Sqm but n.exe 3.0 Sqm) , Matte Black/Silver/any other colour Wall Mirror with Metal Frame, Decorative type complete all as specified and directed. |
| 160 | M&L for floor trap with grating for 100mm dia outlet pipe, including making good distrubd area/surfaces with cement concrete/cement mortar 1:2:4 etc including taking down old unserviceable floor trap |
| 161 | S&F for 75mm dia PVC T fixed with rubbr ring fixed to wall including scafolding all as specified and directed. |
| 162 | Demolition of cement concrete(un-reinforced) Concrete of any description and in any position not otherwise specifically provided for etc compelete |
| 163 | Material and labour for complete/Partial removal of loose/ cracked RCC including cutting of reinforcement from RCC roof projection, chajja, fins, facia, railing etc complete all as specified and directed by Engr in charge..Note:- (1) reinforcement & RCC , form work will be measured and paid seperately under respective items,2) The rate shall be inclusive of Scaffolding if required up three storey. |
| 164 | Material and labour for RCC (1:1.5:3) type A0 using 12.5 mm graded aggregate)and applying bonding agent as per manufacture instruction as per and making good with the undisturbed portion and in any position finsihed the surface even and smooth with out using extra cement including necesary welding/binding of reinforcement if required, complete as directed by Engineer in charge.Rate shall be inclusive of bonding agent fosroc nitobond EP ,Sika hibond, Pidilite 301 pidicrete URP. The rate shall be inclusive of Scaffolding if required. |
| 165 | Material and labour for Formwork to chullah hoods, chajjas, troughs, railings and similar items including edges making fair finished surfaces complete all as specified and directed |
| 166 | M&L for Mild steel TMT bars 5 mm to 10 mm dia., cut to length, bent to shape required, in stirrups, spacers and binders and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed. |
| 167 | Demolition of brick work built in CM including all quoins,arches,pillars etc complete all as directed. |
| 168 | M&L for rendering 10mm thick in cement mortar (1:6) internal surfaces fair faces of brick work or concrete surfaces making finished even and smooth without extra cement complete all as specified and directed |
| 169 | M&L for prepartion of new surface of wall for applying two coats of distemper alkali resistant primer incl 1mm thick putty complete all as specified and as directed by the Engineer-in-Charge. |
| 170 | M&L for preparartion of old surface by washing, rubbing down and stopping of distemperd and painted surface and apply one coat of distemper on wall complete all as specified and as directed by the Engineer-in-Charge. |
| 171 | M&L for preparing old external wall surfaces of existing treatment by washing, rubbing down and stopping of weather proof paint and painted surfaces of external wall and applying two coat of antifungal paint incl priming coat of exterior primer including necessary scafolding work for double/single storey bldgs all as directed . |
| 172 | Taking down carefully old copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified. |
| 173 | Material and labour for concealed Modular point wiring with 1.5 Sqmm PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable in and incl rigid PVC conduit concealed /PVC surface conduit with modular cover plate and sunken box of adequate size incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed. Note: a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed |
| 174 | Material and labour for concealed Modular point wiring with 1.5 Sqmm PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable for socket outlet point 5 Amp on same board in and incl rigid PVC conduit concealed /PVC surface conduit with modular cover plate and sunken box of adequate size incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed. Note: a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed |
| 175 | Material and labour for concealed Modular point wiring with 1.5 Sqmm PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable for one light point controlled by two way switch in and incl rigid PVC conduit concealed /PVC surface conduit with modular cover plate and sunken box of adequate size incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed. Note: a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed. |
| 176 | Material and labour for concealed Modular point wiring with 2.5 Sqmm PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable for socket outlet point 5 Amp on Independent board in and incl rigid PVC conduit concealed /PVC surface conduit with modular cover plate and sunken box of adequate size incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed. Note: a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed. |
| 177 | Material and labour for concealed Modular point wiring with 4 Sqmm PVC insulated and sheathed multi stranded (FRLSH) flexible copper conductor cable for 3 pin 15 Amps switch socket outlet (Power point) in and incl rigid PVC conduit concealed /PVC surface conduit with modular cover plate and sunken box of adequate size incl 1.5 Sqmm (FRLSH) PVC insulated and unsheathed multi stranded flexible copper conductor cable as earth wire(green colour) to common earth dolly complete all as specified and directed. Note: a) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc(b) On RCC roof ceiling PVC conduit shall be provided on surfaces for fan etc with proper fixing clips all as directed. |
| 178 | Supply and fixing modular switch 1 way 6Amp, 1 module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 179 | Supply and fixing modular Fan step regulator, 120W - 2 module , 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 180 | Supply and fixing modular Type Bulb Holder 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 181 | Supply and fixing modular bell push 1 way 6Amp, 1 module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 182 | Supply and fixing modular switch 2 way 6Amp, 2 module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 183 | Supply and fixing modular sockets 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 184 | Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 185 | Supply and fixing modular switch 16A 1 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, c with cover plate omplete all as specified and directed. |
| 186 | S & F Modular cover plate with frame & flush box of 8 modules, complete all as specified and as directed. |
| 187 | S & F Modular cover plate with frame & flush box of 6 modules, complete all as specified and as directed. |
| 188 | S & F Modular cover plate with frame & flush box of 4 modules, complete all as specified and as directed. |
| 189 | S & F Modular cover plate with frame& flush box of 3 modules, complete all as specified and as directed. |
| 190 | S & F Modular cover plate with frame & flush box of 2 modules, complete all as specified and as directed. |
| 191 | S & F Modular cover plate with frame & flush box of 1 module, complete all as specified and as directed. |
| 192 | S & F Modular Blanking plate of 1 module, complete all as specified and as directed. |
| 193 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified. |
| 194 | Supply and fixing call bell ding dong, AC, 230 V, Single pole ISI marked all as specified and directed. |
| 195 | Taking down old unserviceable LED fittings any type ,Supply and fixing LED lights fitting 1x 18W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete. |
| 196 | Taking down old unserviceable LED fittings any type ,Supply and fixing LED lights fitting 1x 10W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete. |
| 197 | S & F Wall bracket decorative LED light Light fitting with lamp 1x9/1x10 Watt bulk head luminaries including LED light driver holder connecting up with three core flexible copper conductor ,metalic housing complete with necessary connection including taking down old unserviceable one complete all as specified and directed. |
| 198 | M&L for cutting of circular hole at any type of wall suitable size for fixing of exhaust fan of size 300mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including,making good to disturbed surfaces of wall to match as per the existing colour complete as directed and specified by engineer-in-charge. |
| 199 | M&L for cutting of Square hole at any type of wall suitable size for fixing of exhaust fan of size 250mm sweep, grouting 04 Nos 100mm long 12mm dia stud bolt including,making good to disturbed surfaces of wall to match as per the existing colour complete as directed and specified by engineer-in-charge. |
| 200 | Taking down existing Exhaust fan of any capacity and refixing the same all as directed by Engr-in-Charge |
| 201 | Supply & fix exhaust fans AC single phase 230/ 240 V of size 250 mm sweep Fiber body with louvers complete all as specified and directed |
| 202 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m copper winding four metal blades BEE approval/ISI Marked air delivery shall not be less than 1600 CMM aT 1400 rpm M mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt single phase 50 cycle per second AC supply and connecting up using flexible cord wire 3 core using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable fixed in position as recomended by manufacture complete all as specified and directed. |
| 203 | Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc includng fixing of bolts , nuts grouted into the wall , and necessary cement work , making good of disturbed surface of wall , giving electric and water connection and testing after installation complete all as specified and as directed. |
| 204 | Taking down existing water heater of any capacity and refixing the same all as directed by Engr-in-Charge |
| 205 | Taking down fan, sealing cable end, dismantling blades and removing fan and blades to MES E/M store etc |
| 206 | Supply and installation testing and commissioning of 1200 mm sweep BEE 5 star rated ceiling fan with brush less Direct current (BLDC) motor class of insulation B power factor not less than 0.9 service value (CMM/W) minimumn 6.85 Air delivery not less than 230 CMM 350 RPM (tolerance as per IS: 374-2019), THD less than 10% including remote or electronic regulator unit for speed control and all remaining accessories including safety pin unts bolts washers temparature rise 75 degree C maximam insulation resistance more than 2 mega Ohm suitable for 230 V 50 Hz single phase ACD supply complete all as specified directed |
| 207 | Supply and fix in32mm dia GI tubing light grade bracket all over 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32mmx5mm 2 nos with suitable size of nuts bolts and washers including two coats of synthetic enamel paint over a coat of redoxide primer on the surface of MS clamp for street BLdg secuiri light fings after taking down old existing unserviceable brackets and light fittings complete all as directed. |
| 208 | Supply and fix in replacement Bldg security light fittings 35 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed. |
| 209 | Supply and fix in replacement MCB TPN DB 4 way vertical sheet metal enclosure suitable for fixing MCCB of appropriate capacity as incomer and SP for outgoing ,415 volts, 50 Hz, with IP-43 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified. . (Note : MCB SP/MCCB shall be measured and paid seperately under appropriate items of this schedule . Note : Copper thimble shall be used for connection of cable . complete all as specified and directed. |
| 210 | Supply and fix in replacement MCB Distribution board , 240 volts single pole and neutral ,double door, 12 way sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down complete all as specified and directed. |
| 211 | Supply and fix in replacement MCB Distribution board , 240 volts single pole and neutral ,double door, 12 way sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down complete all as specified and directed. |
| 212 | Supply and fix in replacement MCCB Vertical Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down complete all as specified and directed. |
| 213 | Supply and fix MCB SP 40 to 63 Amps, 16KA breaking capacity 415 Volts complete all as specified and directed including taking down old one complete all as specified and directed by Engr-in-charge. |
| 214 | Supply and fix MCB TPN 63 Amps, 16KA breaking capacity 415 Volts complete all as specified and directed including taking down old one complete all as specified and directed by Engr-in-charge. |
| 215 | Supply and fix RCBO with earth leakage, over load and short circuit proptection, DP, 240 Volts, 32 Amps, 30 mA senstivity complete all as specified and directed including taking down old one complete all as specified and as directed by Engr-in-charge. |
| 216 | Supply and fix in replacement MCB, single pole 240 volts 6 to 32 Amps capacity fixed complete all as specified and as directed by Engr-in-Charge. |
| 217 | Taking down aluminium submain wire along with damaged casing caping /PVC conduite pipe from the wall roof or floor and making good distrubed surface complet all as specified and directed by Engr-in charge |
| 218 | M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.NOTE: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit and cutting chases & making good shall be measured as one RM |
| 219 | M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 25 mm dia concealed on wall/ceiling in ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion inculding taking down old wiring etc complete all as directed.NOTE: Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit and cutting chases & making good shall be measured as one RM. |
| 220 | Material and labour for earthing in replacement complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways and one handle for lifting made out of 8 mm dia TMT bar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.all as specified and directed by Engr-in-Charge. |
| 221 | Supply and fixing/laying 40mm bore, steel tubings, galvanised, light grade with all fitting laid across road , in trenches or across PCC drain or along electric pole or floor/wall etc for protection of cable complete all as specified and as directed. |
| 222 | Supply & laying Sand coarse dry as in cushioning of underground electric cable in trenches, laid to a uniform thickness of 23cm (15cm under the cable & 8cm over the cable ) and gently punned down to 18cm thickness all complete as specified and as directed. Note :- Only punned down sand shall be measured. |
| 223 | M&L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed |
| 224 | S& F Energy Efficient Integrated Solar Street light 36 watt including GI Octagonal pole duly painted with aluminium paint 5.5 mtr long , made with High Efficiency Mono Crystalline Solar PV Module, lithium Ferro Phosphate Batteries with in Built BMS Technology , high Efficacy LED, MPPT Solar Charge Controller and Aluminium extruded body & is Specially Programmed to automatically control, Dusk to Dawn Operation, Working temperature: (-) 10C to (+) 55C, Weight: 18–20 kg incl housing for connection of incoming cable and outgoing, PCC foundation and foundation Bolts with adjustable MS clamp suitable for pole/wall mounting, having Protections: Short Circuit, overload, Reverse polarity and battery protections all as directed and Specified by Engr-in-Charge . |
| 225 | Taking down old unserviceable under ground LT XLPE/PVC cable of any size from trenches/wall/roof/.road/pipe/pole/aDB including taking out of brick layer of cable protection complete all as directed. |
| 226 | Supply, lay in trenches, floors ,fix on wall/pole, passing through pipes etc.,LT UG cable , 1100 volts grade, PVC/ XLPE insulated , with multistranded aluminium conductors, armoured with galvanised steel wire or tape ,gland, lugs etc , of size 25 Sq.mm 4 core , confirming to IS specifications |
| 227 | Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP-R pipes SDR 6 (PN-20) and PP-R plain fittings in trenches/walls/cellings or laying in floors complete of size outer dia 32 mm, including fittings all as specified and as directed |
| 228 | S&F PPR gate valve 32mm size all as specified and as directed |
| 229 | M&L for MCCB 125A capacity suitable with VTPN all as specified and as directed |
| 230 | Taking down carefully MCB DBs SP/TP with existing iron box cover by unscrewing from main switch boards/cut out boxes and removing materials to store for keeping in safe custody for reuse at site or for taking credit including sealing the cable ends and making good disturbed surface of wall etc as per existing finishes complete all as specified and directed. |
| 231 | M&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper FRLS conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed cable 1100 volts grade, ISI-694 marked with valid CML No. for one 3 Pin 5 Amps socket out let point on independent board in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), , including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following all as specified & directed by Engr-in-Charge. |
| 232 | Supply and fix in repairs of MCB TPN DB 6 way double door,IP 43 protection,isolated neutral bar,insulated bus bar assembly,mechanical strength of IK09, fix with concealed wall incl. make good wall surface by plastering and civil workcomplete all as specified and directed. |
| 233 | Supply and fix in repairs of MCB SP 6 to 32 Amps 'B' Series 10 KA,240 volts complete all as specified and directed. |
| 234 | supply and fix surge protection device(SPD) single phase 230volt 50Hz T-2 limb lmax 20KA per pole complete fixed in distribution board and making connection complete all as directed |
| 235 | Supply and fixing LED fitting 1x18 watts including Tube rod, 230 Volts, bipin holders connector block etc.complete with all accessories internally pre-wired and including provision of PVC round block 7.5cm dia and 2 cm in depth (2 Nos) for mounting the fittings and electrically connecting with three single core 23.0.0076 PVC insulated multistranded copper conductor flexible cable from ceiling rose to light fitting, complete all as specified and directed. |
| 236 | Material & labour for Sub main wiring with two runs of single core 6 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh into PVC casing caping including PVC insulated stranded copper conductor nominal cross section area as under as contineous earth continuity wire complete all as specified. Two run of 6 Sqmm cable one run of 6 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 237 | Material & labour for Sub main wiring with two runs of single core 4 Sqmm (Nominal Area) FRLS PVC insulated and unsheathed multi standed copper conductor cable LT 1100 volts grade drawn thorugh into PVC casing caping including PVC insulated stranded copper conductor nominal cross section area as under as contineous earth continuity wire complete all as specified. Two run of 4 Sqmm cable one run of4 Sqmm earth continuity wire for connection to DBs/dolly shall be deemed to be included in this item and shall be measured as one run complete all as specified and directed. |
| 238 | S&F XLPE Al cable 50 sqmm 3.5core complete all as specified and as directed |
| 239 | S&F for 32 mm dia GI tubing light grade bracket over all 1.2 mtr length with cutting as required and bend to shape with flat iron clamp of size 32 mm 2 Nos, suitable size of nut bolts and washers complete for fixing street light fittings on electric poles including taking down old unsv / fully rusted existing unsv one complete all as specified and directed. |
| 240 | S&F Sleek design 18 W LED warm white Ceiling light having wide voltage protection (160V-300V) and Surge protection, complete all as specified and as directed . |
| 241 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. |
| 242 | Supply & filling sand cushioning to the under ground cable 8 cm before laying the electric cable and 15 cm after laying the cable complete all as specified considering as per SSR 1991 of part -I complete all directed. |
| 243 | M&L for common burnt clay building bricks (locally available best quality), sub-class ‘B’ designation 75 of size 230x115x75 mm to cover LT underground cables , laid dry and flat complete all as specified and directed. |
| 244 | S&F GI light grade tube of size 40 mm dia for laid in trenches/ wall for protection of cable complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 28, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysOct 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender