Tender For Repair / Maintenance To Certain B/R And E/M Works To Certain Bldgs At Sqa(E) Varangaon Under Ge (S) Ahilyanagar
Tender Value
10 Lakhs
Estimated cost
Bid Submission
16 Oct 2026
12 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalgaon → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair / Maintenance To Certain B/R And E/M Works To Certain Bldgs At Sqa(E) Varangaon Under Ge (S) Ahilyanagar
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling asbestos cement sheet (corrugated or semi corrugated etc) including ridges in large patches as in roof covering complete all as specified and as directed.Note:- Dismantling existing wind tie and refixing the same where required for taking down of sheets shall deemed to be included in the unit rate quoted . |
| 2 | S&F prepainted galvalume aluminium zinc coated galvanised iron based corrugated steel sheets 0.5 mm thick of any colour having tensile strength 550 MPA as in roof covering or ridges with side lap and end laps, hips and straight flashing fixed with self taping screws (length & girth as fixed) complete all as specified and as directed. Note:- Colour & Pattern to be approved by Engineer-in-Charge. |
| 3 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed. |
| 4 | S&F Steel work in Rolled sections section as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates. Fe 410 -W (Gde- E- 250) quality- A complete all as specified and as directed. |
| 5 | S&F Expanded metal exc 4 Kg per Sqm, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members |
| 6 | M&L for brickwork with old size fly ash bricks straight or curved on plan with mean radius exc 6m built in CM 1:6 including demolition of brick/ block/ stone masonry built in cement mortar complete all as specified and directed. |
| 7 | M&L in repairs, for water proofing treatment to RCC roof slab, including parapet, comprising with the following treatment/specification from bottom to top:-(a) Taking down existing roof treatment of any type and any thickness including mud in roofs, plastering, leaping plaster of any thickness cutting & uprooting trees /roots / vegetation growth & removing the debris from the site premises outside MoD land.(b) Cleaning existing surface properly including roughening the old concrete slab by picking, sweeping clean and washing down with water to remove dust etc(c) Screed bed or bedding layer of 10 mm thick cement mortar 1:4 with mixing of WPC @ 3% by weight of cement or as per manufacturers instructions and surface finished even and smooth without using extra cement after applying a coat of cement slurry @ 3 kg/sqm for laying APP membrane. |
| 8 | (d) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.30 ltr /Sqm conforming to IS:3384-1986.(e) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 150 gms/Sqm) shall be applied over bituminous primer as specified above by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(f) Applying two coats of bituminous aluminium paint over APP membrane @ 0.11kg/sqm.Note: Water proofing compound shall be measured & paid separately. |
| 9 | M&L for Providing cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate in roof kerbs, parapets and railings coping ,kneelers , apex stones , bed plates ,water throughs and the like including weathering , slightly rounded or chemfered angles and throating including taking down loose plaster, concrete complete all as specified and as directed . |
| 10 | Taking down chowkats or frames with shutter (without taking out shutter from the frame), area n.exc 1.5 sqm each complete all as specified and as directed. |
| 11 | Taking down chowkhats or frames with shutter (without taking out shutter from the frame), area exc 1.5 sqm but not exc 4 sqm each all as specified and as directed. |
| 12 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 13 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 30 mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges 4 nos per leaf of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-in-Charge. |
| 14 | S&F in repair powder coated anodised aluminium ventilator having aluminium section weighing not less than 0.55 kg/m, including aluminium louvers, frosted 3mm thick glass, SS wire mesh, including arrangement for fixing of exhaust fan and necessary joining cleats,glazing clips,screws etc complete all as specified and as directed.Note : Shade and size shall be as approved by Engineer-in-Charge. |
| 15 | S&F 100mm size stainless steel butt hinges, medium weight and welded to existing mild steel pressed steel chowkat or fixed to wooden frame all as specified. |
| 16 | S&F 150mm size extruded aluminium alloy handles, fabricated type, anodised and fixed all as specified and as directed. |
| 17 | S&F 150mm size aluminium anodized barrel tower bolts of extruted section and fixed all as specified and as directed. |
| 18 | S&F 300mm long aluminium alloy anodised sliding door bolts with hasp, staple and fixing clip of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast- aluminium alloy all as specified and as directed. |
| 19 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thick (below or above ground level) all as specified and as directed. |
| 20 | Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing complete all as specified and as directed. |
| 21 | M&L for 75mm thick plain cement concrete 1:4:8, type D2 using 40 mm graded stone aggregate as in sub base finished even and fair complete all as specified and as directed. |
| 22 | M&L for non skid coloured ceramic 7-8mm thick (square or rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified & directed.Note: Color and shade shall be as approved by Engineer-in-charge |
| 23 | M&L for glazed ceramic tiles of size 450mm x 350mm x 7 mm thick on vertical surfaces, laid over and including 10 mm thick rendering in cement mortar 1:4, set & jointed in neat cement slurry and pointed in white or colour cement to match the colour of tiles complete all as specified and as directed. |
| 24 | Dismantling of stone slab and tiles laid bedded and pointed in any mortar description or thickness in floors, apron etc complete all as specified and as directed. |
| 25 | M&L for precast cement concrete interlocking tiles 80mm thick factory made, hydraulically pressed cemented tiles of grey cement with pigments, chamfered edge, with glossy finish of M-40 grade conforming to IS-15658-2006 and of approved colour, design, pattern, size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 25mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand complete all as specified and as directedNote : Size, shape & pattern of tiles shall be as approved by GE. |
| 26 | M&L for Plain cement concrete 1:3:6, Type C2, (using 40 mm graded corase aggregate) as in foundation , filling and mass concrete complete all as specified and directed |
| 27 | Taking down cement plaster on walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed. |
| 28 | M&L for rendering 15 mm thick on fair faces of brick work /concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement complete all as specified and as directed. |
| 29 | M&L for rendering 10 mm thick on fair faces of brick work or concrete suraces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and as directed |
| 30 | M&L for rendering 5mm thick in cement mortar (1:3) on concrete surfaces and in ceiling finished the surface even and smooth without using extra cement complete all as specified and directed. |
| 31 | M&L for newly plastered wall surfaces, preparation of surface and applying applying two coats of 100% premium exterior acrylic emulsion paint (weather coat) alkali & fungal resistance, dirt resistance of required shade over and including priming coat of exterior primer complete all as specified and as directed. |
| 32 | M&L for Preparation of newly plastered wall surfaces and applying a coat of average 1.5mm thick putty, sanding the surfaces till smooth finish is obtained and finally applying two coats of oil bound distemper over a coat of primer complete all as specified. |
| 33 | M&L for Preparation of newly plastered ceiling surfaces and applying two coats of oil bound distemper over a coat of primer complete all as specified. |
| 34 | M&L for complete removal of existing treatment on old surfaces of ceiling including cornices by scraping with steel scrapers or any other means and applying a coat of average 1mm thick putty and applying two coats of oil bound distemper over a coat of primer complete all as specified . |
| 35 | M&L for complete removal of existing treatment on old surfaces of wall including cornices by scraping with steel scrapers or any other means and applying a coat of average 1mm thick putty and applying two coats of oil bound distemper over a coat of primer complete all as specified . |
| 36 | Material & Labour for complete removal of existing treatment on old plastered or unplastered wall surfaces and applying Two coats of 100% Premium exterior acrylic emulsion paint weather coat paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed. Note : Cost of necessary scaffolding and safety measures is deemed to be included in the unit rate quoted |
| 37 | M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over one coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 38 | S&F in repairs of Hollow PVC Wall Panelling consisting of 5mm thick single side printed PVC sheets to be fixed on GI Frame (fixed to wall at 0.9m centre to centre in both horizontal and vertical directions to make square frame fixed to wall with screws) with necessary fixing arrangement as directed, solvent cement where necessary and making good the joints of sheets, edges and openings with PVC beading of matching pattern complete all as specified and as directed.Note: Colour and Pattern of Panelling shall be decided by Engineer-in-Charge/GE. |
| 39 | S&F laminated Gypsum tile board 8mm thick with textured white colour PVC film on the face side and metalized polyster (MPL) film on rear side in ceiling as per manufacturers instructions of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm |
| 40 | and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, including dismantling of existing false ceiling of any description complete all as specified and as directed. |
| 41 | S&F in repairs 15mm bore UPVC pipes Sch 40 including fittings, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 42 | S&F in repairs 20mm bore UPVC pipes Sch 40 including fittings, any length with fittings such as socket, elbow, bends, tees, reducer, union, caps plug, nipple etc complete laid in walls/ ceiling or laying in floor trench or fixed to walls complete all as specified and directed. |
| 43 | S&F in repairs, vitreous china wash down water closet (pedestal pattern) white, including connection to drain (or outgoing pipe) and flushing pipe, anti syphonage pipe, trap set and including white or black seat cover for pedestal pan with mild steel chromium plated aluminium hinging device, fixed to pan with suitable screws, etc. complete all as specified and as directed.Make: Cat No. S1053102 of CERA or equivalent model of makes specified. |
| 44 | S&F in repairs 10 ltr capacity PVC valve-less, syphonic action type flushing cistern, low level, white with inlet ball valve and handle including brackets complete all as specified and as directed.Make: Cat No. B1010110 of CERA or equivalent model of makes specified. |
| 45 | S&F in repairs vitreous China Half stall urinal, white with grating and union for discharge pipe (excluding flushing cistern) including urinal spreader of brass chromium plated for fixing with 15 mm dia pipe, PVC connection, 40mm PVC waste pipe & 40 mm waste coupling providing and fixing plugs, bedding urinal against wall in mortar 1:2, securing urinal to plug, with and including 60mm long screws, pointing around urinal back in cement, fixing flush pipe complete all as specified and as directed.Make: Cat No. S4020112 of CERA or equivalent model of makes specified. |
| 46 | S&F in repairs, rotational moulded polyethylene water storage tanks Triple layer (cylindrical vertical with closed top) of 1000 litres capacity hoisted and fixed in position, including 20 mm dia ball valve, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed to iron pipe and connecting all as specified and as directed. |
| 47 | S&F in repairs 20mm dia gun metal globe or gate valve, wheel head cast copper alloy screwed down light pressure with crutch or butterfly handle screwed both ends for iron pipe or for union, ISI marked complete all as specified & as directed |
| 48 | S&F in repairs, Health faucet (ABS Body) suitable for 15 mm dia pipe with 1 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.Make: Cat No. F8030111AB of CERA or equivalent model of makes specified. |
| 49 | S&F in repairs, bib tap 15mm dia, with wall flange and aerator screwed down for iron pipe or for brass ferrule complete all as specified and as directed.Make: Cat No. F1015151 of CERA or equivalent model of makes specified. |
| 50 | S & F in repairs, stop/ angle valves, 15mm dia, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or unions complete all as specified and as directed.Make: Cat No. F1015201 of CERA or equivalent model of makes specified. |
| 51 | S & F in repairs, PVC connections, 15 mm size with brass check nuts of length 600 mm complete all as specified and as directed. |
| 52 | S&F in repairs, 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated screws and cup washers complete all as specified and as directed. |
| 53 | S&F in repairs, 75 mm dia PVC(SWR) nahani trap with grating including jointing to waste pipe with solvent cement, fixed in cement concrete type (1:2:4) type B1 using 20mm graded stone aggregate all as specified and as directed. |
| 54 | S&F vitreous china wash hand basin, white flat back of size 515 mm x 410 mm including brackets, 32 mm waste coupling brass chromium plated suitable for wash hand basins, with long screwed shanks and fly nuts and PVC waste pipe15mm dia, PVC connection pipe 450mm long complete all as specified and as directed.Make: Cat No. S2040121 of CERA or equivalent model of makes specified. |
| 55 | S&F in repairs, 15 mm bore pillar taps, cast copper alloy with capstan heads, fancy type, chromium plated screwed down high pressure with or without lettered 'HOT' or 'COLD' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and as directed.Make: Cat No. F1015101 of CERA or equivalent model of makes specified. |
| 56 | S&F in repairs, 110mm bore, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed. |
| 57 | S&F in repairs, 110mm bore, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls all as specified and as directed. |
| 58 | S&F in repairs, 110mm bore PVC (SWR) branch piece, double (double Y) equal or unequal with oval access door all as specified and as directed. |
| 59 | S&F in repairs, 110 mm dia PVC (SWR) bends of any radius with oval access door complete all as specified and as directed |
| 60 | S&F in repairs, 75mm bore, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, fixed to walls all as specified and as directed. |
| 61 | S&F in repairs, 75mm bore, PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors all as specified and as directed. |
| 62 | S&F in repairs, 75 mm dia PVC (SWR) bends of any radius complete all as specified and as directed |
| 63 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, bell push, holders, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc and making good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed. |
| 64 | M & L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990, PVC insulated and unsheathed, FRLS cable drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC holding boards/bakelite sheets for mounting switches, sockets, fan Regulators, accessories etc as specified and directed for one light point or one fan point controlled by one, one way switch. |
| 65 | NOTE: 1. Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) 2. wiring shall be done as per complaints received from user only on reqired basis it is not necessary to do whole wiring of any whole bldg.3. All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc. |
| 66 | All as per serial item No. 62 here in before but one 6 Amp 3 pin socket outlet point on same board with other switches including earth wire as specified. |
| 67 | All as per serial item No. 62 here in before but on independent board. |
| 68 | All as per serial item No. 62 here in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 69 | All as per serial item No. 62 herein before but with 2.5 Sqmm, PVC copper stranded cable FRLS type for phase,Neutral and earth for one 15 Amp, 6 pin socket on independent board. |
| 70 | S&F switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish, all as specified & as directed. |
| 71 | S&F switch socket combination, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way, suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & as directed. |
| 72 | S&F switch socket combination, multipurpose, flush type, 2 in 1 type (3 pin ) 6/16 Amps, 230V, AC. all as specified & as directed. |
| 73 | S&F lamp holder, angle/ batten type, PVC/Polycarbonate type with back plate, suitable for batten fittings all as specified & as directed. |
| 74 | S&F in repairs, lamp LED 9/10 Watt, 230 volts 50 Hz AC complete all as specified and as directed. Make: HAVELLS Cat No. LHLDEUEEML8R0110 or equivalent model of makes specified. |
| 75 | S&F fancy type ceiling rose, surface PVC 50mm dia, 3 terminals including PVC mounting block white/ivory finish all as specified & as directed. |
| 76 | S&F bell push, flush type, 6 Amp, single pole, 230 volts, white finish all as specified & as directed. |
| 77 | S&F fan regulator, step type, electronic on existing phenolic laminated sheet, 5 step, socket type, 230 volts, suitable for ceiling fan 1200/1400mm sweep all as specified & as directed. |
| 78 | S&F bell, AC, 230 volts, single phase complete all as specified and as directed. |
| 79 | S & F in repairs Inverter LED batten 20W 6500K with square profile and polycarbonate channel, lithium-Ion battery with charging time 8hours-10 hours, back up time up to 4 hours and surge protection up to 4KV.Make : HAVELLS PRIDE PLUS INVERTER BATTEN Cat No. LHEXASP7IN1W020 or equivalent model of makes specified. |
| 80 | M & L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed FRLS cable conforming to IS-694, 1100 volts with copper conductor, multi stranded drawn in and including suitable size heavy grade casing caping (ISI marked) with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed FRLS copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduit complete all as specified and as directed. NOTE: 1. Proper colour coding shall adopted for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black)2. Three runs of 4 sq.mm cable and one run of PVC casing & caping shall be measured as one unit. |
| 81 | S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'c' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. |
| 82 | S&F in repairs, MCB SPN, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'c' series, making connection with suitable size of copper lugs etc complete all as specified and as directed. |
| 83 | S&F in repairs double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 8 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 84 | Supply and laying in trenches or fixing or passing through pipe, 1100 Volts grade, armoured, heavy duty LT UG cable of size 35 Sqmm, 3.5 core with XLPE insulated stranded aluminium conductor including cable gland, lugs, testing and commissioning complete including taking out old unserviceable cable from trenches/poles etc, alongwith protection covers all as specified and as directed. |
| 85 | M&L for heat shrinkable straight through cable joint kit suitable for 25 to 50 Sqmm 3.5 core LT XLPE cable 1100 Volts grade complete with jointing material and accessories and testing including necessary excavation / earth work complete all as specified and as directed. |
| 86 | Supply and laying Double Walled Corrugated (DWC) HDPE pipe of nominal bore 50mm including 90 degree bends with coupler and rubber ring, conforming to IS :16205 Part 24 Type 450N, laid in trenches for cable protection complete, all as specified and as directed. |
| 87 | Excavation in trenches not exc 1.50m wide and not exc 1.50m deep for foundation etc . or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and as directed |
| 88 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and as directed. |
| 89 | Removing excavated soil to distance not exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed |
| 90 | M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to GI earth strip 32 X 6 mm by means of nut bolts, check nuts and washer of the GI. Earth wire connected upto main earth point/DBs alongwith 40mm dia GI pipe, light grade protection pipe, including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. Note : Rate of GI strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in this item. |
| 91 | M & L for Taking out hermetically sealed compressor unit (uncut) from the Split/Window Air conditioner of any make & type of 1.5 TR capacity and replacing the sealed unit with new sealed unit as per existing makes complete including following work all as specified and as directed. (Existing Make:- Voltas/ Carrier/ Blue star/ Kirloskar/ Tuchmesh/ Usha/ Godrej/ Whirlpool/ LG/ Kenstar) (i) Connection to suction/discharge pipe with necessary repair and brazing. (ii) Replacing the capillary tubes of existing size and copper liquid filter. (iii) Flushing of entire system before gas charging. (iv) Gas charging and testing after complete repairs including installation of the machine at site and testing on full load for its smooth functioning complete. |
| 92 | S&F in repairs, relay for existing make and model of split type AC of capacity 2 TR single phase, 240 Volts, AC supply including connecting and testing of relay all as specified and as directed. |
| 93 | S&F in repairs, thermostat with switch for existing make and model of split type AC of capacity 2 TR all as specified and as directed. |
| 94 | S&F in repairs, starting capacitor 80/100 mfd or suitable capacity including necessary electrical connections, lugs, insulation tape etc for existing make and model of split type AC of capacity 1.5 TR all as specified and as directed. |
| 95 | S&F in repairs, PCB electronic circuit including LCD of indoor/ outdoor unit of 2 TR of existing make and model of split AC all as specified and as directed. |
| 96 | S&F in repairs, remote for existing make and model of split type AC of capacity 2 TR all as specified and as directed. |
| 97 | S&F in repairs, swing assembly complete made of PVC, heavy duty for existing make and model of split type AC of capacity 2 TR all as specified and as directed. |
| 98 | S&F in repairs, swing motor, single phase, AC supply, for indoor unit of existing make and model of split type AC of capacity 2 TR all as specified and as directed. |
| 99 | S&F in repairs, running capacitor 45/50 mfd including necessary electrical connections, lugs, insulation tape etc for existing make and model of split type AC of capacity 2 TR all as specified and as directed. |
| 100 | S&F in repairs, over load protector for existing make and model of split type AC of capacity 2 TR all as specified and as directed. |
| 101 | S&F in repairs, capillary tube and drier filter of any make of 2 TR split AC with brazing, nitrogen flushing, leak testing and gas charging complete.all as specified and as directed. Note:- Charging of gas as specified by manufacturer will be measured and paid under respective item . |
| 102 | Servicing of AC, split type, 1.5/ 2.0 TR capacity of any make, by cleaning the whole equipment, washing of filters, minor adjustments/repair, washing condenser unit, indoor and out door unit complete all as specified and as directed. |
| 103 | M&L for gas charging to compressors of AC, Split type, 2 TR capacity of any make installed machine/ equipment to its full capacity with specified grade (as per OEM recommended) with refrigerant including other connected process required for gas charging and testing complete all as specified and as directed. |
| 104 | Removal and Refixing in another location split AC of capacity 1.5/2.0 TR including making hole in the brick/ shelter/ stone walls and making connections, fixing of brackets and insulating pipe lines with nitrile rubber, brazing of copper tubes including testing/ commissioning complete as required at site, including shifting of service connection, metal clad box and voltage stabilizer to the new location all as required. SOP is to be followed by proper pumping down of refrigerant gas before dismantling all as specified and as directed. (i) Refrigerant pipes shall be measured and paid in respective item. |
| 105 | S&F in repairs, connecting and testing copper refrigerant pipes, along with proper insulation with nitrile rubber of suitable size for incoming and outgoing pipes complete all as required at site for 1.5/2.0 TR TR split AC all as specified and as directed. Note : One run of both copper pipes incoming and outgoing shall be measured as 01 RM unit for payment purpose |
| 106 | S&F in repairs, nylon pipe, cotton braided, size 15mm dia, suitable for drain of split type AC, capacity 1.5/2.0 TR all as specified and as directed. |
| 107 | S&F in repairs, mounting frame/ stand including fasteners and nut bolts suitable for outdoor unit of split AC of any size complete all as required at site all as specified and as directed. |
| 108 | S&F in repairs, sheet metal enclosure, single pole & neutral with two pin & earth plug and socket with one MCB and plug top, single pole 20 amp, 240 volts complete all as specified and as directed. |
| 109 | S&F in repairs, metalic plug top, 3 pin for AC point, 15 Amps single phase, 240 volts, AC ISI marked, all as specified and as directed. |
| 110 | Supply and fix in repairs foam insulation sheet 6 mm thick for duct covering of air cooling system complete all as specified and as directed. |
| 111 | Supply & fix exhaust fans PVC body AC single phase 230/ 240 V of size 250 mm sweep with, blades, and frame and louvers,50 HZ ,min1200 RPM including fixing ,by means of rugged bolts,nuts and washers etc,including 2 core copper conductor flexible cord of suitable size of required length from ceiling rose to the porcelain connector block of the exhaust fan including taking down old fan and depositing to E/M store complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysOct 19, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender