Tender For Special Repair To Building No T-128 And Allied Works At Osq Under Cijw School Vairengte
Tender Overview
Project Description
Tender For Special Repair To Building No T-128 And Allied Works At Osq Under Cijw School Vairengte
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Oct-2026 | Sch of credit revised | Other | 17-Oct-2026 |
| 2 | 01-Oct-2026 | BOQ revised | BOQ | 17-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | B & R Division Items |
| 2 | Demolition of un-reinforced cement concrete in ground floor and paving not exceeding 15 cm thick (below or above ground level) complete all as specified and directed. |
| 3 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 4 | Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to stores and rubbish off the premises. |
| 5 | Dismantling plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding, etc.including all necessary staging / scaffolding, etc. as required complete all as specified and as directed. |
| 6 | Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 7 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work complete all as specified and directed. |
| 8 | Dismantling boarding any description fixed in any position with nails all as specified. |
| 9 | Demolition and breaking up 100/110mm bore drain pipes, salt glazed ware, AC or reinforced concrete set in cement mortar complete all as specified and directed. |
| 10 | Dismantling of 75mm bore cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 11 | Demolition of reed lathing, single or double including battens and plaster or chiken wire lathing all as specified. |
| 12 | Taking down cement plaster including raking out joints, hacking for key scrubing down with water etc complete all as specified and as directed. |
| 13 | Taking down chowkhats or frame with shutters (without taking off shutters from frame) each not exceeding 1.50 Sqm each complete all as specified. |
| 14 | Taking down Chowkhats or frames with shutters exceeding 1.5 Sqm but not exceeding 4 Sqm each (without taking off shutters from the frame) complete all as specified. |
| 15 | Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 16 | Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 17 | Excavation in trenches, n exc 1.50 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loose type of soil complete all as specified and directed. |
| 18 | Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as specified. |
| 19 | Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as specified. |
| 20 | M&L for PCC (1:4:8), Type D2 using 40 mm graded stone aggregate as in foundations, sub-base,filling and mass concrete complete all as specified. |
| 21 | M & L for 75mm thick cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in sub base to floors/path and pavement complete all as specified and directed. |
| 22 | M & L Plain Cement concrete (1:3:6), type C-1 using 12.5mm graded stone aggregate as in filling of hallow steel chowkhats, bed block, fixing of holdfast and similar likes including necessary formwork complete all as specified. |
| 23 | Use and waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 24 | Use and waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete all as specified and directed. |
| 25 | Use and waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide all as specified and directed. |
| 26 | M & L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in foundation including rafts, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and directed. |
| 27 | M & L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in column, pillars, piers, posts, and struts complete all as specified and directed. |
| 28 | M & L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in beams, cantilever, lintels over 1.5m complete all as specified and directed. |
| 29 | M & L for Reinforced Cement Concrete M-25 (design mix) using 20 mm graded aggregate as in cill band and similar items like complete all as specified and directed. |
| 30 | M & L for Mild steel TMT Bars 10mm dia and over, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 31 | M & L for Mild steel TMT Bars 6mm to 8mm dia, cut to length bend to shape as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 32 | M & L for Mild Steel TMT Bar 6mm dia and over up to 10 mm dia as in stirrups, spacers and binders as required including cranking, hooking etc and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed |
| 33 | M & L for brickwork with subclass 'B' straight or curved on plan exc 6 m mean raduis, built in CM (1:6) complete all as specified and directed. |
| 34 | M & L for half brick work with Subclass ‘B’ old size, straight or curved on plan to radius built in cement mortar (1:4) complete all as specified . |
| 35 | M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick wall or concrete surfaces, finished the surfaces even and fair without using extra cement complete all as specified. |
| 36 | M & L for rendering 15 mm thick cement mortar 1:4 on fair faces of brick wall or concrete surfaces & water proofing compound mixed @ 2% finished fair and even complete all as specified. (Note :WPC measured separately). |
| 37 | Supply only integral water proffing compound WPC complete all as specified. |
| 38 | M & L light vitrified ceramic tiles coloured 7 to 8mm thick (square/ rectangular) area of each tile not exceeding 0.36 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile over including 15 mm thick screed bed or bedding layers in cement mortar 1:6 for tile over brushing with neat cement slurry as specified |
| 39 | M & L light vitrified ceramic tiles coloure ceramic tiles 7 to 8mm thick ( square/rectangular) area of each tiles exc 0.18 sqm but not exc 0.36 sqm as in vertical surfaces of skirting/bdado etc over 10 mm thick rendering in cm (1:4) as backing coat for tile complete all as specified. |
| 40 | M & L for Non Skid ceramic tiles coloured 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tile including 15 mm thick screed bed or bedding layers in cement mortar 1:6 over brushing with neat cement slurry complete all as specified. |
| 41 | M & L Glazed ceramic coloured tiles in vertical surface size 450mm x 350mm x & ( 6mm to 7mm )mm thick set skirting/dado and jointed in neat cement slurry and pointed in white or colour cement to match over & including 10mm thick screed bed or backing coat in cement mortar 1:4 laying of skirting/dado on walls all as specified and directed. |
| 42 | S & F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 43 | S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 44 | S & F Framed work such as grills, gratings, etc.. with ends of bars or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 45 | S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers,hold fasts, bands, straps, wall ties, plain angle cleats, eaves board frame and similar articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 46 | S & F structural steel work in tubular/hollow sections trusses , Purlin , posts, rafter etc including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as as specified and directed. |
| 47 | S & F Solid PVC door frame of size 50mm x 47mm made of 5 mm plain colour PVC sheet reinforced with mild steel square tube , supplying & fixing in opening as per specification & drawing complete all as specified . |
| 48 | S & F factory made single extruded WPC solid door/ window/ ceostrdoor frame of size 50mm x 95mm made of 5 mm single sidev plain colour PVC sheet reinforced with mild steel square tube , supplying & fixing in opening as per specification & drawing complete all as specified . |
| 49 | S & F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, S & Fing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified. Make: Rajshri or equivalent as approved. |
| 50 | S & F Factory made wire gauzed PVC moulded door shutter 30 mm thick (style) wire gauzed i.e. panel will be of wire gauze in lieu of wood grain printed PVC sheet panel. The wire gauze shall be wrapped on an additional square 8mm M.S. Solid tube and this tube shall be welded to M.S. tubes. The wire gauge shall be stretched to tighten firmly consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain printed PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing. |
| 51 | S & F Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick prelaminated Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified. |
| 52 | S & F 3 ways sliding anodized aluminium glazed window shutter with frame with the following specification all as specified & directed.(a) Window frame 3 track of size 95mm × 25mm × 1.5mm thick.(b) Stiles and rails of size 35mm × 25mm × 1.5mm.(c) 35mm × 35mm × 1.5mm T section mullion.(d) PVC gasket with 4mm thick tinted glass, incl. aluminium handles with necessary locking arrangement for 02 Nos glazed shutter.(e) Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm, fixed with stainless steel wire staples, incl. aluminium handles with necessary locking arrangement for 01 No gauzed shutter.Note: Measurement to be taken as overall width and height of window. No shutter or frame to be measured separately. All necessary accessories including tinted glass and stainless steel wire cloth required for assembling and fixing window at proper place complete are deemed to be inclusive. |
| 53 | S&F 100mm long SS Butt hinges (ISI marked) with SS screws complete all as specified. |
| 54 | S & F 150 mm long aluminium alloy handles extruded section cast type anodised complete all as specified & directed . |
| 55 | S & F 150 mm long aluminum anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 56 | S&F 150mm extruded brass handles, fabricated type polished complete all as specified and directed. |
| 57 | S & F 200 mm long brass tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed. |
| 58 | S & F 250mm Brass, sliding door bolt with sand or die-cast brass hasp, staple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified. |
| 59 | S & F as in repair stainless steel curtain rods with brackets including fixing stops, rollers bracket etc with harrison rails all as specified and directed . |
| 60 | S & F, as in repair, vitreous china wash basin, white flat back size 550 x 400 mm, excluding taps, waste chain, plug and porcelain stopper but including 32mm waste coupling, brackets, cutting for and pinning in ends of bracket or erecting stand complete all as specified. |
| 61 | S&F in repair for single piece vitreous china wash down water closet pan of pedestal pattern, white, with P or S trap including plastic water closet seat cover, white, close pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device, jointed in white cement, complete all as specified and directed.Make: Hindware Cat Part No. 20125 with Cistern fittings or equivalent make as approved list of make. |
| 62 | S & F as in repair soap dish chromium plated standerd quality fixed on wall with brass screw complete all as specified. |
| 63 | S & F in repair PVC connections 15mm size with PTMT nuts of length 450 m complete all as specified. |
| 64 | S&F in repair 15mm chromium plated two way bib taps long body with flange fixed in 15mm bore of pipe, cast copper alloy, with crutch or butter fly handle, screwed down for iron pipe complete all as specified and directed. |
| 65 | S & F in repair 15mm bore angular stop cock, cast copper alloy cromium plated fancy type screwed for 15 mm bore GI pipe or for unions complete all specified and directed. |
| 66 | S & F in repair 15mm brass CP for mixing hot or cold water screwed down iron pipes and fixed complete all specified and directed. |
| 67 | S & F in repair 15mm brass CP wall mixer, 3 in 1, of approved design, for mixing hot or cold water screwed down iron pipes and fixed complete all specified and directed. |
| 68 | S & F in repair chromium plated Towel ring fixed with and including CP brass screw and wooden/plastic cleat ( Minimum weight 90gms) complete all as specified. |
| 69 | S & F in repair Towel rail, 20mm dia brass chromium plated, 600mm long with fancy type brass chromium plated brackets on both sides and fixed with steel screws and wooden/rawl plugs complete all as specified. |
| 70 | S&F in repairs toilet paper holder with flat recessed type stainless steel fixed to wall with chromium plated brass screws complete in all respect as specified |
| 71 | S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 72 | S & F in repair Chromium plated shower roses with swivel joints and wall bracked, any size including fixing to steel pipe or union complete in all respect as specified. |
| 73 | S&F in repair sheet glass shelf assembly complete all as specified and directed. |
| 74 | S&F in repair glass shelf with bracket, fancy type with stainless steel railing fixed to wall with rawl plugs and chromimum plated screws complete all as specified and directed. |
| 75 | S & F as in repair 600mm X 450mm bevelled edge mirror of selected quality glass, mounted on 9mm thick AC building board or commercial plywood and PVC moulding frame fancy type complete all as specified and directed. |
| 76 | S & F 150mm bore PVC (SWR) pipes single socketed with rubber joint, in any length, for eves gutter complete all as specified. |
| 77 | S & F 110mm bore PVC (SWR) pipes single socketed with rubber joint, in any length, with rubber ring joints, laid in trenches or in floors complete all as specified. |
| 78 | S & F 75mm bore PVC (SWR) pipes single socketed with rubber joint, in any length fixed to walls / floors or in trenches complete all as specified. |
| 79 | S & F in repairs 110mm bore PVC (SWR) bend suitable for pipe complete all as specified. |
| 80 | S & F in repairs 75mm bore PVC (SWR) bend suitable for pipe complete all as specified. |
| 81 | S & F 150mm bore PVC (SWR) bend suitable for pipe complete all as specified. |
| 82 | S & F in repairs 150mm bore PVC (SWR) tee any radius complete all as specified. |
| 83 | S &F in repair PVC(SWR) floor trap, 75mm dia outlet, plain with grating including jointing with solvent cement complete all as specified. |
| 84 | Supply & Fixed in repair 150mm square size Grating PTMT (minium wt 100 gms) complete all as specified. |
| 85 | S & F 15mm bore galvanised iron water tubes medium grade with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified. |
| 86 | S & F 20mm bore galvanised iron water tubes medium grade with all fitting and fixed to wall, ceiling or laid in floor and trench complete all as specified. |
| 87 | Providing & fixing false ceiling with semi perforated 12 mm thick micro tegular edged or 10 mm thick square edge at all heights with GRG (Glass Fiber Reinforced Gypsum) false ceiling tiles of size 595 × 595 mm of approved texture design and pattern having moisture content less than 2%, humidity resistance of 99%, NCR 0.50 to 0.75 as per IS 8225 : 1987, non-combustible as per BS 475 (Part-IV) 1970 and light code description Unit Rate No. 429, Sub Head 26.0 – New Technologies and Material, reflectance of 85% minimum, laid in true horizontal level, suspended on interlocking metal T-grid of hot dipped galvanized iron section of 0.33 mm thick (galvanized @ 120 gms/sqm including both sides) comprising of: Main T runner of size 15 × 32 mm, length 3000 mm.Cross T of size 15 × 32 mm, length 1200 mm.Secondary intermediate cross T of size 15 × 32 mm, length 600 mm.To form grid module of size 600 × 600 mm, suspended from ceiling using galvanized metal sheet item (galvanized @ 80 gms/sqm), i.e. 50 mm long, 8 mm outer diameter M-6 fasteners, 6 mm dia fully threaded hanger rod up to 1000 mm length, and L-shape level adjusters of size 85 × 25 mm, galvanized iron perimeter wall angle of size 24 × 24 × 0.40 mm, length 3000 mm, to be fixed on perimeter of wall/partition with the help of plastic rawl plugs at 450 mm centre to centre and 40 mm long drywall screws.The work shall be carried out as per specification, drawing and as per direction of Engr-in-Charge |
| 88 | M & L for complete removal of existing treatment on walls including washing rubbing down & stopping of cement base, distempered and other painted surface complete all as specified and directed. |
| 89 | M & L for applying two coats of acrylic distemper over one coat of alkali resistant primer including preparation of newly plastered surfaces all as specified and directed |
| 90 | M & L for preparation of new surface and applying wall care putty in two coats of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified. |
| 91 | Material & Labour for preparation of new plastered surface applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm using roller complete all as specified and directed. |
| 92 | M & L preparation of old steel surfaces of any description over 10cm width or girth not otherwise described and applying one coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 93 | Preparation of new steel surfaces surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer of surfaces complete all as specified. |
| 94 | E & M Division items |
| 95 | Taking down carefully copper/aluminium point wiring (light, fan, buzzer, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc including removing from site for taking credit and making good to disturbed surface of walls, floors etc as per existing specification complete all as specified and as directed. |
| 96 | Taking down carefully submain wiring including all accessories without disturbing existing wiring fittings fixtures etc and making good to the disturbed surfaces all as directed and as specified in any type and size all as directed. |
| 97 | Dismantling old unserviceable main switches, sheet metal enclosures DB including MCBs etc and removing from site for taking credit incl making good to disturbed surface of wall as per existing specification complete all as specified and as directed. |
| 98 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty,PVC conduit including all accessories etc ISI marked, with modular metal flush box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One light point controlled by one switch. |
| 99 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One fan point/exhaust fan point controlled by one, one way switch . |
| 100 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on the same board. |
| 101 | M & L for point wiring with FRLSH stranded copper conductor 1.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 1.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for One 3 pin 5 Amp socket outlet point controlled by one switch on independent board. |
| 102 | M & L for point wiring with FRLSH stranded copper conductor 2.5 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, PVC Conduit including all accessories etc ISI marked, with GI sunken box suitable for fixing switches, sockets and regulators including PVC insulated stranded copper conductor 2.5 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent |
| 103 | M&L for point wiring with FRLSH stranded copper conductor 4.0 sqmm (nominal area), two single core, PVC insulated cable 1100 volts grade, ISI-694 marked in and including heavy duty, concealed PVC Conduit concealed type of suitable size including all accessories etc ISI marked, with GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover for fixing switches, sockets and regulators including PVC insulated FRLSH stranded copper conductor 4.0 sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for 3 pin, 15 Amp socket outlet, independent.Note: The point wiring will be done from DBs to the switch sockets of any size with three wires running independently for each point and with no tappings. |
| 104 | S&F modular switch 1 way 6A/10A, 1 Module complete all as specified and directed. |
| 105 | S&F modular switch 1 way 16A/20A, 1 Module complete all as specified and directed. |
| 106 | S&F modular socket 6A/10A, 2/3 pin combined 2 module complete all as specified and directed. |
| 107 | S&F modular socket 16A/20A, 2/3 pin combined 2 module complete all as specified and directed. |
| 108 | S&F ceiling rose surface bakelite with three terminals all as specified and directed |
| 109 | S&F ceiling fan regulator socketed, step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified. |
| 110 | S&F lamp holder insulated body with back plate for batten fitting complete all as specified and directed. |
| 111 | S & F bell push modular 6amp single pole, one way 1 module complete all as specified and directed.. |
| 112 | S & F in repair bell multi musical type AC 230 volt, single pole (ISI marked) complete all as specified and directed.. |
| 113 | S&F modular white cover plate 4 module with frame ISI marked complete all as specified and directed.Make- Havells SAP code AHLPLCWV04 or equivalent make of Anchor/Legrand) |
| 114 | S&F modular white cover plate 6 module with frame ISI marked complete all as specified and directedMake- Havells SAP code AHLPLCWV04 or equivalent make of Anchor/Legrand) |
| 115 | S&F modular white cover plate 8 module with frame ISI marked complete all as specified and directedMake- Havells SAP code AHLPLCWV04 or equivalent make of Anchor/Legrand) |
| 116 | M & L for submain wiring with two single core 4.0 sqmm PVC insulated unsheathed cable multi-strand copper conductor FRLSH drawn through and including PVC non metallic rigid PVC Conduit with all fittings and fixing accessories on roof, walls, ceiling etc including 1 x 4.0 sqmm PVC insulated unsheathed multi strand copper conductor earth wire FRLSH connecting earth including cutting groove for concealed wiring, making good to disturb surface of wall/floor with cement mortar and finishes to match existing complete all as specified and directed. Note: Two run of single core cable, one run earth wire and one run PVC Conduit will be measured as one length. |
| 117 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed. |
| 118 | S&F 600 x 600 mm LED type down lighter 36 watt complete with drivers connecting accessories and provision of fixing arrangement in false ceiling complete all as specified and directed. |
| 119 | S & F surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including Lamp 1X20 Watt, (4 feet) fixed properly on wall surface and connecting complete from ceiling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit complete all as specified and directed.. |
| 120 | S&F bldg security light, LED luminaire 25 watt IP 66 LED lamp, driver etc with all accessories complete all as specified and directed. Bajaj or equivalent make of Havells/M/S Jaquar & Company Pvt Ltd. |
| 121 | S&F plastic body exhaust fan 250mm sweep complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding and connecting to ceiling rose with flexible copper cable including making holes on the wall and making good to the disturbed surfaces complete all as specified and as directed. |
| 122 | S&F BLDC ceiling fan 1200mm sweep complete with blades, down rods and accessories, 230 V, min air delivery 210 CFM with service value 6.00 BEE 5 star rated & provn of ‘S’ type fan hook including taking down of old UNSV one and depositing to MES storeyard for keeping in safe custody complete all as specified and directed including one step type electronic regulator. |
| 123 | S&F metal plug socket with MCB SP 20 Amp, 240 V enclosure for AC/equipment with neutral and earth point complete all as specified and directed. |
| 124 | S&F sheet metal enclosure powder coated single phase DB for fixing of MCBs, 8 way double door with Aluminum bus bar 100 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 125 | S&F sheet metal enclosure powder coated three phase and neutral (TPN) DB for fixing of MCBs, 4 way double door with aluminum bus bar 100 Amp including grouting on the wall by means of screws and rawal plugs and making good disturbed surfaces complete all as specified and directed. |
| 126 | S&F MCB TPN of capacity 63 Amps, 240 V, 10 KA 'B' curve complete all as specified and directed. |
| 127 | S&F MCB SPN of capacity 40-63 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed. |
| 128 | S&F MCB SP of capacity 5-32 Amps, 240 V, 10 KA 'C' curve complete all as specified and directed. |
| 129 | Supply, fixing, commissioning & testing of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, Electric power cable (heavy duty) with aluminium conductors, 1100 volts, grade cross sectional area 25 sqmm 3.5 core laid in trenches/fixed to wall/under road/pipe etc with copper cable glands & copper thimbles complete all as specified and directed. |
| 130 | S & F PVC connection pipe complete all as specified and directed. |
| 131 | Taking down and re-fixing electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection pipe etc complete all as specified and as directed. |
| 132 | Taking out old existing earthing and M & L for new earthing with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm dia GI wire protected by 20 mm bore light grade galvanised iron pipe and other end connected to test point as directed including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternaterlayers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover 10mm thick hinged to CI frame and 6mm MS rod for handle, necessary excavation and earth wok in hard/dense soil and disposal of spoil to a distance n exc 50 m and necessary testing complete all as shown in electrical plate No 3 of SSR part-I complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 13 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender