Tender For Special Repair To 04 Offrs Accommodation Bldg No T-104, T-105, T-106 And T-107 At Fire & Fury Offrs Mess (14 Cesr) Under Age B/R-Ii Of Ge 865 Ews, Leh
Tender Value
36.86 Lakhs
Estimated cost
Bid Submission
19 Oct 2026
15 days left
EMD
73800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To 04 Offrs Accommodation Bldg No T-104, T-105, T-106 And T-107 At Fire & Fury Offrs Mess (14 Cesr) Under Age B/R-Ii Of Ge 865 Ews, Leh
BOQ
| Sl. No. | Item Description |
| 1 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling all as specified and directed. |
| 2 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling all as specified and directed. |
| 3 | S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates and similar work conforming to grade Fe 410- W (Gde-E-250 quality A), complete all as specified. |
| 4 | Dismantling structural steel work including doors and gates of any description. |
| 5 | Dismantling wall and ceiling boards (Fiber, pulp, insulation, blankets) any thickness including covered fillets and supporting members. |
| 6 | M & L for providing and fixing Gypsum boards 9 mm thick PVC film on the face side and other side metalised polyster flim as in ceilings fixed with screws as per manufacturers instructions including anodised aluminium powder coated snap grid frame work of size 605 x 605 mm with anodised aluminium channel supports/ angles/ 'T' (Main tee 35 x 25 x 1.5 mm, cross tee 25 x 25 x 1.4 mm and wall angle 32 x 32 x 2 mm) fixed with screws/ plugs etc including GI suspenders of 4 mm dia upto 1200 mm length adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3 mm size as per approved pattern and design complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for 8mm thick teak wood finish laminated wooden flooring interlocked with each others and its size as directed,over 6 micron polyethylene sheeting over the concrete to minimize moisture migration from the concrete including demolition complete all as specified and directed .. |
| 8 | S&F 2nd class soft wood clean sawn as in scantling fixed with nails including dismantling. |
| 9 | M&L 6mm (5 ply) thick veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on one face, fixed with nails to timber frame work, including dismantlng complete all as specified and as directed. |
| 10 | S&F fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5mm thick tinted glass and partly panelled with 12mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150mm size, aluminium barrel tower bolt 200mm size, including hydrolic door closer all as specified and directed. (a) Frame ( top & side) section shall of size 101.60 x 44.75 x 2.4mm (Section No 14021) (b) Vertical Members of shutter section shall be of size 85.00x44.45x2.00mm (section No 19560) (c) Top Members of shutter Section shall be of size 83.50 x 44.45 x 2.00mm (section No 19581) (d) Lock rail (Middle member) of shutter section shall be of size 150.00x44.45x3.00mm (section No 19596) (e) Bottom Members of shutter section shall be of size 150.00x44.45x3.10mm (section No 19584) (f) Glazing clip for securing glass of shutters shall be of 0.80mm thick (section No 19370), including taking down existing complete as directed. |
| 11 | S&F Anodised aluminium powder coated window with Aluminium gril and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.), including taking down existing complete as directed. |
| 12 | S&F 150mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed |
| 13 | S&F in 150mm long anodized aluminum door handle cast type. |
| 14 | M&L for plain sheet glass 4.00mm thick ordinalry quality and glazing with oil putty or wooden beads in square or fixed with aluminium section including rubber beads not exc 0.50 sqm in each pane complete all as specified and as directed by Engr-in-Charge. |
| 15 | Taking down chowkats/frames with shutters (without taking off shutters from the frames) area n'exc 1.5 Sqm each complete all as specified and directed. |
| 16 | Demolition brick work / block masonry or stone/ boulder masonry, built in built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 17 | Material and Labour precast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonry with solid blocks,exc.10cm in width and setting in cement mortar 1:6, complete all as specified and/or directed. |
| 18 | M&L rendering 15mm thick in CM 1:4 on fair faces of concrete or brick surfaces as in wall finishes even and smooth w/o using extra cement complete all as specified and as directed by Engr-in-Charge. |
| 19 | M&L rendering 15mm thick in CM 1:6 on other than fair faces of concrete or brick surfaces as in wall finishes even and smooth w/o using extra cement complete all as specified and as directed by Engr-in-Charge. |
| 20 | M&L for Preparing newly plastered surfaces of walls and applying two coats of acrylic emulsion paint over a coat of primer over a coat of wall care putty applied till the surface is smooth etc. complete all as specified and/or as directed . |
| 21 | M & L for Preparing newly plastered surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer including 1mm thick birla wall care putty complete all as specified and directed |
| 22 | Demolition of cement concrete (un reinforced ) in ground floors and pavings n.exc 15cm thick (below or above ground level ) all as specified and removing debris ouside MD land. |
| 23 | Material & Labour 25mm thick PCC 1:2:4 type B-0 using12.5mm graded crushed stone aggregate as in flooring and finished surface as in received tiles complete all as specified and as directed. |
| 24 | S&F PVC coated mild steel conduit pipe 25 mm bore (Drapper rod) with a pair of PVC coated MS clamps to hold drapers rod and decoractive attachment at one or both ends of drapers rod, fixed to opening of door/windows (each opening n.exc 1.50m, contained with a pair of clamps and pair of side ornamented attachments) including taking down , complete all as specified and directed. |
| 25 | M&L for 75mm thick PCC 1:3:6 type C2 (using 40mm graded crudhed stone aggregate) in alternate bay as in plinth protection 1.20 Sqm each, 12mm wide and 5 cms deep joints shall be formed between the bays and shall be filled with mastic filling comprising a mixture of one part of heated blown bitumen VG-10 and two parts of heated coarse sand (by volume) incl dismantling, all as specified. Note:- The unit rate include for use of form work (straight or curved). |
| 26 | S&F Rotational moulded polyethylene water storage tank (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I of capacity 1000 litres Iincluding dismantling of water tanks and remove to store, complete all as specified. |
| 27 | M&L for coloured non skid ceramic tiles 7 to 8mm thick (Square/rectangular) area of each tile exc 0.18 sqm but n.exc 0.38 sqm, laid in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed in CM 1:6 including taking down all as directed. |
| 28 | S&F for glazed ceramic tiles coloured of size 450x300x7mm thick fixed in verticle surfaces, set and jointed in neat cement slurry and pointed in white and colour cement to match incl 10mm thick screed bed in CM 1:4 incl taking down all as directed. |
| 29 | S&F 25mm bore 3-layer PP-R Polypropylene random copolymer concealed pipes SDR 7.4 (PN 16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass treaded polypropylene incl all random fittings fixed complete to walls, ceilings or in floors etc. including taking down old tubing complete all as specified. |
| 30 | Dismantling of 75 / 110mm bore cast iron ,PVC or reinforced concrete pipes jointed in cement mortar and taking out of trenches if reqd of any dia |
| 31 | S&f 75 mm bore PVC (SWR) pipe single socketed , in any length with rubber joints laid in trenches or in floors. |
| 32 | S&f 110 mm bore PVC (SWR) pipe single socketed , in any length with rubber joints laid in trenches or in floors. |
| 33 | S&f 75mm bore PVC (SWR) pipe bends any radius |
| 34 | S&F PVC (SWR) 110mm bore bends any radius, complete all as specified |
| 35 | S&F PVC (SWR) 110mm bore junction single (single T), complete all as specified |
| 36 | S&F 75mm bore PVC (SWR) junction single, (Single T) equal or unequal |
| 37 | M&L 75 mm bore PVC (SWR)) multi floor trap with grating including jointing with solvent cement |
| 38 | S&F PVC (SWR) 'S' trap 110mm bore for EWC/IWC |
| 39 | S&F in repairs Vitreous china water closet pan (pedestal pattern), white including fixing bolts etc including fixing of plastic water closet seat cover, black/white closed pattern with flat bottom and cover and mild steel chromium plated hinging device, flushing cistern etc. |
| 40 | S&F in repairs for viterous china wash hand basin flat back size 550x400 mm including taps, waste coupling, wate pipe , pillar tap , plug and porcelain stopper incl brackets, complete all as specified. |
| 41 | M & L for providing cement concrete type B0 1:2:4 (12.5 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges including demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for |
| 42 | S&F in repairs 20mm bore stop cock fancy type chromium plated cast copper alloy screw down under high pressure with handle screwed both ends for iron pipe or brass ferrule. |
| 43 | S&F in repairs Bib tap chromium plated with crunch or butterfly handle , screwed for iron pipe or for brass pipe and fixed. |
| 44 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge. |
| 45 | Point wiring complete with 1.5 Sq.mm nominal area of copper conductor multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed multistranded 1.5 Sqmm copper conductor cable as continuous earth lead all as specified and directed for the followings:- |
| 46 | One light/exhaust fan point controlled by one way switch |
| 47 | One bell point controlled by one bell push on independent board. |
| 48 | One 3 pin switch socket combination 5 Amp on independent board complete all as specified and directed. |
| 49 | One 3 pin socket out let 5 Amp on the same board with other switches complete all as specified and directed. |
| 50 | All as item No 45 above, but using cables 2.5 Sq mm size for 15 Amps socket point. |
| 51 | Supply and replacement of lamp holder insulated body with back plate. |
| 52 | Supply and fixing of Switch piano flush button single pole 6 Amps 230 volts one way complete all as directed. |
| 53 | Supply and fixing of switch Socket combination 5 pin 5 & 15 Amps flush type.230 volts complete all as directed. |
| 54 | Supply and fixing of switch Socket combination flush type 3/5 pin 5/6 Amps 230 volts complete all as directed. |
| 55 | Supply and fixing of Ceiling rose, surface Bakelite three terminals complete all as directed. |
| 56 | Supply and replacement of bell push single pole 230 volt complete all as directed. |
| 57 | M & L in repair for bell ding-dong single pole complete all as directed. |
| 58 | Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 4 Ways all as specified and directed by Engr-in-Charge. |
| 59 | Supply and fix in replacement of MCB SPN 40 to 63 Amp 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge. |
| 60 | Supply and fix in replacement of MCB SP 6-32 Amps C curve. 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 61 | Supply and fix in replacement of MCB SP 6-32 Amps C curve. 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysOct 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender