Road Transport and Highways Government Departments Closing in 9 days TDR #57734385

Tender For Interlocking Blocks On Vulnerable Location Between Km 249/180 To 250/080 Rhs In Village Talwara & Installation Of Street Light, High Mast Light And Divider And Other Road Safety Works On Nh- 927A Km. 151/400 To 256/000

Issued by Government Departments · Banswara, Rajasthan
Tender Value
5.33 Crore
Estimated cost
Bid Submission
26 Oct 2026
9 days left
EMD
10.66 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Banswara → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Interlocking Blocks On Vulnerable Location Between Km 249/180 To 250/080 Rhs In Village Talwara & Installation Of Street Light, High Mast Light And Divider And Other Road Safety Works On Nh- 927A Km. 151/400 To 256/000

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Oct-2026 SBD Technical Bid 26-Oct-2026

BOQ

Name of Work:- Interlocking blocks on vulnerable location Between Km 249/180 to 250/080 RHS in village Talwara & Installation of Street light, high mast light and Divider and other road safety works on NH- 927A Km. 151/400 To 256/000
Sl. No. Item Description
1Providing and erecting a \\"W\\" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ ground level, fixed on CRC rolled channel vertical post, 150 x 75 x 5 mm spaced 2 mm centre to centre, 1.8 m high, 1.1 m below ground / road level, all steel parts and fitments to be galvanized by hot dip process, all fittings to conform to IS: 1367 and IS: 1364 , metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per MoRTH specification Clause 811.3.
2Providing & fixing letters/ borders from reflective tape ofapproved quality of standard width (MORTH SpecificationClause 800) P & F Borders (50mm wide
3Earth work in excavation for foundation of structure complete with all lift, dewatering shoring and shuttering etc. .including refilling of trenches in 25.mm layers, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical specification.in hard soil [MoRTH Specification : Clause : 301] ITEM NO. 12.1.2.2 above 3 to 6m depth
4Earth work in excavation for foundation of structure complete with all lift, dewatering shoring and shuttering etc. .including refilling of trenches in 25.mm layers, ramming, watering and disposal of surplus soil within a lead of 1000 meters, as per drawing and technical specification.in ordinary/soft rock [MoRTH Specification : Clause : 301] ITEM NO. 12.1.3.2 .if blasting is not resorted to
5Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification. [MoRTH Specification : Section 1700(N)&1500(N)]. Using Batching Plant, Transit Mixture, and Concrete Pump.P.C.C.M-15 grade ITEM NO 12.7.1
6Cement concrete for plain/reinforced concrete in open foundation as per drawing and technical specification. [MoRTH Specification : Section 1700(N)&1500(N)]. Using Batching Plant, Transit Mixture, and Concrete Pump.P.C.C.M-25 grade
7Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces new surface ITEM NO. 8.76.1
8Supply and erection of Galvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular/ Conical cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have hinged lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 for Octagonal & P-02 for Conical with base plate and foundation bolt on the Existing cement concrete foundation. To ensure quality of product it's entire manufacturing process starting from sheet cutting to galvanization sould be done under one premises. Poles with Octagonal/Conical Cross Section ITEM NO 18.1.1 , Mtr.(in staggered of 25.0 M interval) ITEM NO 18.1.1.7 9
9Supply and Fixing of Pole OEM fabricated hot dipped galvanised M.S. Overhang (48.3 X 3.25 mm) with cap ( 250x 88.9 / 114.3 x 3.25 mm) over the existing poles. Single arm overhang ITEM NO 18.2.1
10Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles as per Drawing attach at Table P-05 with Following ProcedureA) Excavation of Pit for Foundation Size upto required depth from Ground level B) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-20 grade in Footing and Pedestal including Curing the foundation for minimum 7 days.Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr ITEM NO 18.8.2
11Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing and secondary lens on each LED/ integrated lens diffuser without cover & should be High power LED of 3 to 5 watt each . The System efficacy >=135 lm/ wt and integrated metal case potted driver & has a unique BIS R number ( as per IS 15885) with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC & Low Voltage cutoff @>=90 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . LED driving output current <750mA. The luminaire shall be BIS certified (Fitting & driver both have separte BIS R number) and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs as required.LED Street Light fixture with Minimum lumen output 12150 lm ITEM NO 18.12.6
12Supply, Installation, Testing and Commissioning of Smart Lighting Controller in existing feeder panels which includes, Inbuilt energy metering with 3 nos CT, Three phase power supply with withstanding capability up to 500 VAC, Instant mode, Fixed Mode, Astronomical Mode, Hybrid Mode, Interval Mode, Offset in Sunset and Sunrise Timing for scheduling. Provision for measurement of all three phase electrical parameters like voltage, current, power factor, power, frequency, energy with atleast class 1 accuracy and compliant with IS13779 standard, UV-OV protection, backup battery 4 hrs, Andriod/iOS app and software to operate form computer, provision to add display device externally, support for RS485 communiction , inbuilt GSM/GPRS 4G modem with 2G fallback, Real time GPS based clock, calender, lithium ion battery backup for RTC clock, Three relay output, Minimum Ninety days data memory inbuilt backup facility, Controller shall be type tested with NABL approved lab for EFT or burst testing for conducted immunity in accordance with IEC 610000-4-4, Software application should utilize a Low-Code/No-Code platform to simplify development and customization. It must be hardware-agnostic and compatible with other IoT-based smart city applications. Software should have undergone a \\"Vulnerability Assessment and Penetration Testing (VAPT)\\" as per OWASP Top 10 2021 and 2022, SANS CWE 24 & CERT-In Standard.Dedicated IoT communication GSM/GPRS SIMCard (with minimum 3 years of recharge)for 4G Communication with software application. 3 Years Data Hosting & Server Charges to be included with software.
13Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.25.0 Sq. mm ITEM No. 11.2.5, 3.5 core item no 11.2.5.3
14Providing & Laying XLPE insulated & P.V.C. sheathed Armoured Aluminium cable confirming to IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing commissioning etc. as required of following size.70.0 Sq. mm Item no 11.2.8, 3.5 core item no 11.2.8.4
15P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). 50mm item no 12.13.1,
16P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of trench, CC Haunching, Back filling of Earth with compaction is to be Paid Extra). 90mm item no 12.13.4
17SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a) Thickness of CRCA sheet shall not be less than 1.6 mm upto 450 mm length/ width of any compartment and be 2.0 mm above 450 mm, load bearing structure shall be 2.0 mm thick sheet supported by base M.S. channel if required, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b) complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side(Inner & Outer side) of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d) Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e) All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f) Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI type Test certificates for Temp. rise test, Short circuit test for 50 kA and IP test is to be submitted)
18Providing & Fixing of Electromechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. One day reserve (Electromechanical type ) item no 8.22.1
19Providing & Fixing of Electromechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. One day & week reserve (digital type ) item no 8.22.2
20SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation from 50 to 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle ( to be paid extra) , including making connections etc. as required. OEM shall have submit NABL / CPRI / ERDA/ Intertek accrediated lab type test certificate.4 pole MCCB With Microprocessor based release with adjustable O/L & S/C setting with Inbuilt Instantaneous and Ground fault Protection item no 9.3.4, Upto 160 Amp , 50 kA item no 9.3.4.1
21Plate Earthing as per IS:3043 with copper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying 3 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, Heavy duty weather proof poly-propylene earth inspection chamber as per requirement of IS/IEC 62305 and tested as per IEC 62561-5 with lockable Jam free lid suitable for safe working load 60 kN of round / square size 250 mm, and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required.
22Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping double the width of strip and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.20mm x 3mm G.I. ( Hot Dipped ) Strip item no 14.6.13
23Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. Single pole MCB (With B / C curve tripping characteristics) item no 6.1.1, 0.5 A to 5 A rating item no 6.1.1.1 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57734385
AUTHORITY Government Departments
TENDER VALUE 5.33 Crore
LAST DATE 26-10-2026
Authority
Authority Name ministry of road transport and highways
Work Description Tender For Interlocking Blocks On Vulnerable Location Between Km 249/180 To 250/080 Rhs In Village Talwara & Installation Of Street Light, High Mast Light And Divider And Other Road Safety Works On Nh- 927A Km. 151/400 To 256/000
Basic Detail
Tender No NIT 2/2026-27 EE PWD NH Dn Banswara
Bidding Type Tender
Location
City Banswara
State Rajasthan
Key Dates
Publish Date 09 Oct 2026
Submission Date 26 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 5.33 Crore
Tender Fee 10000
EMD 10.66 Lakhs
Exemption Not Available
Document List
BOQ_975122.xls
c64a0019-b3ce-4981-be6e-f22da1e112af.html
NIT2BSW.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 9 days
Oct 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_975122.xls

html

c64a0019-b3ce-4981-be6e-f22da1e112af.html

pdf

NIT2BSW.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender