Defence Statutory Bodies & Commissions/Committees Closing in 27 days TDR #57724576

Tender For Addn/Altn & special Repair Of Park View Offrs Md Accn At Comd Hosp (Ec) Complex Kolkata

Issued by Statutory Bodies & Commissions/Committees · Kolkata, West Bengal
Tender Value
4.64 Crore
Estimated cost
Bid Submission
24 Oct 2026
27 days left
EMD
5.39 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Addn/Altn & special Repair Of Park View Offrs Md Accn At Comd Hosp (Ec) Complex Kolkata

BOQ

Name of Work:- ADDN/ALTN & SPL REPAIR OF PARK VIEW OFFRS MD ACCN AT COMD HOSP (EC) COMPLEX KOLKATA
Sl. No. Item Description
1NOTE (Applicable for all items) :-(i) The bidders/contractors are advised to read tender document & all corrigendum / amendments and General conditions of contracts before entrying/quoting the rates.2. It is highlighted that the certain condition of General Condition of Contracts (IAFW-2249) has been modified as per direction of MoD i.e. inclusssion of Performance Security, deletion of Risk & Cost Provisions and increase in defect liability period all as per tender documents. The tenderers should keep in mind while quoting their offer.
2(Bldg Part)Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. (Upto 4th storey)
3All as per item No.01 above but from 5 storied to 8 storied of building complete all as specified and as directed.
4Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition). (Upto 4th storey)
5All as per item No.03 above but from 5 storied to 8 storied of building complete all as specified and as directed.
6M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers,lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for flat rough finished surface of concrete.(Upto 4th storey)
7All as per item No.05 above but from 5 storied to 8 storied of building complete all as specified and as directed.
8M&L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20mm graded aggregate) in Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. (Upto 4th storey)
9All as per item No. 07 above but from 5 storied to 8 storied of building complete all as specified and as directed.
10M&L for Cement concrete in saucer drains Type B1 1:2:4 (40 mm graded aggregate) slope maintained as per site requirement complete in all respect as specified.
11M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggte as in plinth protection / paving, surface finished even & smooth with using extra cement as complete as specified and directed.
12M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.(Upto 4th storey)
13All as per item No. 11 above but from 5 storied to 8 storied of building complete all as specified and as directed.
14Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders (Upto 4th storey)
15All as per item No. 13 above but from 5 storied to 8 storied of building complete all as specified and as directed.
16M&L for brick work with flyash old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. (Upto 4th storey)
17All as per item No. 15 above but from 5 storied to 8 storied of building complete all as specified and as directed.
18M&L for brick work with flyash old size bricks, straight or curved on plan to any radius in half brick thick walling built in cement mortar 1:4 complete all as specified and directed.(Upto 4th storey)
19All as per item No. 17 above but from 5 storied to 8 storied of building complete all as specified and as directed.
20Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water complete all as specified and as directed.(Upto 4th storey)
21All as per item No. 19 above but from 5 storied to 8 storied of building complete all as specified and as directed.
22M&L for plaster on ceiling 5 mm thick in cement mortar (1:3) on concrecte surface , surface complete all as specified and directed.(Upto 4th storey)
23All as per item No. 21 above but from 5 storied to 8 storied of building complete all as specified and as directed.
24M&L for 20mm thick (in two layer) plastering on fair face of Brick surface with CM (1:4) mixed with WPC finish surface even and smooth with out using extra cement complete all as specified and directed.(Upto 4th storey)
25All as per item No. 23 above but from 5 storied to 8 storied of building complete all as specified and as directed.
26M&L for 15mm thick cement plaster with CM (1:6) on other than fare face of brick wall finsh even and smooth without using extra cement complete all as directed.(Upto 4th storey)
27All as per item No. 25 above but from 5 storied to 8 storied of building complete all as specified and as directed.
28Dismantling removing all unsound concrete, plastered material by chipping/chiseling gently at all effected and adjoining areas of concrete etc till sound surface is reached all various locations in building subsequently cleaning the surfaces by hair brush and air blower and removing rubbish off the premises and disposing at the dumping site as approved by local authorities including hoisting assembling and fixing of double layer steel scaffolding to external perimeter of building complete all as specified and directed . (Upto 4th storey)
29All as per item No. 27 above but from 5 storied to 8 storied of building complete all as specified and as directed.
30Removing of concrete all around reinforcement bar upto 12 mm dia and over from behind the reinforcing bars average 25mm (but not less than 15mm air gap)by manual methods (using wire brushing ,chiseling etc) and applying chloride free rust removing chemical on rusting steel reinforcement bar and removing all rust from steel reinforcement bar by emery paper and cleaning the area thoroughly by water and allow it to dry and totally rust free of reinforcement bar all as complete as per manufacturer's instruction as specified. Make( Rust removing chemical ):- Reebaklens RR of FOSROC or equivalents solutions SIKA/STP. (Upto 4th storey)
31All as per item No. 29 above but from 5 storied to 8 storied of building complete all as specified and as directed.
32Material , labour and preparation of existing reinforcement surface by brush and application of two component epoxy zincrich primer on existing reinforcement surface of minimum specific gravity 1.75, adhesive bond strength with steel is 1.50N/mm2 and maximum coverage area 5.00 Sqm per litre. complete all as specified. Make- Nitozinc primer of FOSROC or equivalents.(Upto 4th storey)
33All as per item No. 31 above but from 5 storied to 8 storied of building complete all as specified and as directed.
34Material and labour for introducing new reinforcement bars upto 12 mm dia and over for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified.(upto 4 storied bldg)
35All as per item No. 33 above but from 5 storied to 8 storied of building complete all as specified and as directed.
36M&L for supply, mixing and placement of micro-concrete cement based prepacked single component chloride free, sulphate free, non-shrink, free flow. elf compacting, ready to use after mixing water in specified proportion of Sika Rep Microconcrete-4 or renderoc-RG of Fosroc in required thickness over a coat of epoxy bonding agent as per manufacture's instruction and all as directed. Compressive strength (ASTN C 109,cm cube) of 35 MPa at 28 days including necessary form work complete all as per manufactures specification.(upto 4 storied bldg)
37All as per item No. 35 above but from 5 storied to 8 storied of building complete all as specified and as directed.
38M&L for providing and applying at two component structural grade polymer modified reinforcement mortar Fosroc Renderoc S2 or equivalent product of SIKA upto a thickness of 30 mm over a coat of epoxy resin bonding agent Nitobond EP. The cured mortar shall achieve a minimum compressive strength of 12N/mm2 in a day & 45 N/mm2 in 28 days with Flexural strength 8N/mm2 in 28 days Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. in addition to this percentage of water absorption should be 0.45 after 24 hours in immersion test at various locations in Bldgs complete all as per manufacture's specification.(upto 4 storied bldg)
39All as per item No. 37 above but from 5 storied to 8 storied of building complete all as specified and as directed.
40Material , labour for applying of high efficiency polymeric resin base film forming curing agent/compound over concrete surface and maximum coverage area 5.00 Sqm per litre as per manufacturers instruction complete all as specified. Make:- Concure LP90 of FOSROC or equivalents solutions SIKA/STP/ Maruti / Choksey chemicals.(upto 4 storied bldg)
41All as per item No. 39 above but from 5 storied to 8 storied of building complete all as specified and as directed.
42M&L for providing and applying a flexible expansion joint membrane of minimum 150mm wide and 1mm thick, expoband one of FOSROC or equivalent over the prepared joint using a two part epoxy adhesive nitobond PC 40 of Fosroc or equivalent. The minimum tensile strength of the membrane should be more than 12 N/mm2 and elongation at break should be more than 400%. The installation of the membrane should be carried out as per manufactures specification.(Upto 4th storey)
43All as per item No. 41 above but from 5 storied to 8 storied of building complete all as specified and as directed.
44M & L for providing and inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete for drilling suitable holes in RCC Slab/ wall/ column/ beams toa depth as directed for anchoring steel reinforcement bars including washing with water inserting lokfix 'E' of Fosroc or equivalent in the holes at various location in Bldgs complete all as per manufactures specification .(Upto 4th storey)
45All as per item No. 43 above but from 5 storied to 8 storied of building complete all as specified and as directed.
46Material & Labour for applying Anti carbonation coating as per manufacturer's specification of approved brand, manually using brushes on the hardened concrete/plastered surfaces after cleaning the surface and removing all loose particles, deposits etc complete including one coat of primer and two coats coatings as directed. (Upto 4th storey)
47All as per item No. 45 above but from 5 storied to 8 storied of building complete all as specified and as directed.
48Material & Labour for Carbon Fibre Wrapping - Nitowrap CWS – 450 GSM Providing and carrying out Fosroc make carbon fibre wrapping Nitowrap CWS (450 GSM) - High Performance high strength, carbon fibre system for structural strengthening to R.C. members. Surface Preparation : Proper surface preparation to be carried out including cleaning, removal of loose material, dust etc, executing required repairing like epoxy injection grouting, polymer modified mortar, epoxy touching Putty , rounding off edges of structural members to 25mm etc . Application : Prepared substrate shall be primed with Nitowrap 30 epoxy primer supplied in pack size 4 Lit (Base-4.1 kg and Hardener -0.46 kg) at a coverage of 8-10 m2/litre/coat, allow the primer to cure for 24 hours followed by application of first coat of saturant Nitowrap 410 supplied in pack size 5kg ( Base - 3kg and hardener - 2kg) (having Tensile strength >30 MPa; Elongation > 2.1% ; Fibre strength > 4900 MPa ; Fibre E-Modulus >230 GPa & Flexural Modulus > 1700 MPa when tested as per ASTM D638 Type I and ASTM D 790 & Glass Transition Temperature > 50 °C as per ASTM E 1356) to be carried out at a coverage of 3.5 to 4 m2/lit/Coat at around 250 microns WFT, cutting of Nitowrap CWS (available in standard roll width of 500 mm and roll length of 50 mtr & 100 mtr) in required size and wrap over wet saturant keeping minimum 150 mm overlap, rolling the same using hard roller to impragnent saturant and again applying second coat of saturant using suitable bush or roller etc, completing as per specification and as directed by Engg.-in-charge. Nitowrap CW fabric used shall exhibit the following properties - fiber density of 1.8 g/cc, dry fibre thickness 0.40mm and shall have tensile strength > 4900 MPa ; tensile modulus > 230 GPa and ultimate elongation of 2.1%.The adhesion of the entire system(FRP Sheet, Saturant and primer combined) with concrete shall be > 3.5 MPa with concrete failure as per ASTM D 4541 complete as per specification and as directed. (Upto 4th storey)
49All as per item No.47 above but from 5 storied to 8 storied of building complete all as specified and as directed.
50M&L for bore packing of all the Spouts to be done with grouting admixture mixes with Cement Concrete / Mortar @225 ml per bag of Cement or as manufactured specification complete all as specified and as directed.
51All as per item No. 49 above but from 5 storied to 8 storied of building complete all as specified and as directed.
52Taking down chowkhats or frame with shutter (without taking off shutters from the frame) exc 1.5 sqm n.exe 4 sqm each.
53All as per item No. 51 above but from 5 storied to 8 storied of building complete all as specified and as directed.
54Taking down rusted steel windows/ventilators/pvc/flush/skelton door of any description and size n exc 1.5 sqm including shutters complete all as specified and as directed.(Upto 4th storey)
55All as per item No. 53 above but from 5 storied to 8 storied of building complete all as specified and as directed.
56S & F factory made 2nd H/W plain solid straight chowkhats,wrought framed rebated on the solid,rounded or chamfered put together with glue pinned at joints complete all as specified and directed. (Upto 4th storey)
57All as per item No.55 above but from 5 storied to 8 storied of building complete all as specified and as directed.
58M&L for Factory made 30 mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on one sides with one face covered with decorative face veneer with lipping/frame to match complete all as specified and directed.(Upto 4th storey)
59All as per item No.57 above but from 5 storied to 8 storied of building complete all as specified and as directed.
60S&F for Factory made, 2nd class Hard wood of thickness 35 mm, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated with sash bars, any numbers, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.24 (a) supplied and fitted to chowkats complete all as directed. (upto 4 storied bldg)
61All as per item No. 59 above but from 5 storied to 8 storied of building complete all as specified and as directed.
62S&F for Factory made single extruded WPC(Wood polymer composite) solid door Frames of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N(Face) & 1100 N (Edge), mimimum compressive strength of 58 N/Sqmm and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof & fire retardant & fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as directed. (upto 4 storied bldg)
63All as per item No. 61 above but from 5 storied to 8 storied of building complete all as specified and as directed.
64S&F for Factory made single extruded WPC(Wood polymer composite) solid flush door shutter of 30mm size comprising of virgin PVC polymer of K value 58-60(Suspension grade), calcium carbonate & natural fibres and non-toxic additives fabricated with mitre joints after applying PVC solvent cement and screwd with full body threaded star headed SS screws having minimum density of 650 Kg/cum, screw withdrawal strength of 1800 N(Face) & 900 N (Edge), mimimum compressive strength of 50 N/Sqmm, modulas of elasticity 850 N/sqmm & resistance to spread of flame of class A category with property of termite/borer proof , water/moisture proof & fire retardant & fixing with SS butt hinges of required size with necessary full body threaded star headed counter sunk SS screws, all as per dirns of EIC. (upto 4 storied bldg).
65All as per item No. 63 above but from 5 storied to 8 storied of building complete all as specified and as directed.
66Supply and fix aluminium anodised (powder coated) Three track sliding window frame with shutters with (2 nos glazed and one wire gauzed shutter) including all necessary joining cleats, hold fast, EPDM gasket, snap beading and locking arrangements fixed with screws to wall etc. complete with glazing and including 5.50 mm thick tinted glass to aluminium frame work using push type gasket and including stainless steel wire cloth of 0.36 mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers as specified with the following section of frame and shutter:- (A) Sections for shutter :- (i) \\"H' section 38 x 20 x 1.50 mm thick. (ii) 'Interlock' section 38 x 20x 1.50 mm thick. (iii) 'Edge & Bottom' section 41 x 20 x 1.50 mm thick.(B) Section for frame :- (i) Top & Sides 92.36 X 29.70X 1.50mm thick. (ii) Bottom 92.36 X 29.70X 1.50mm thick complete all as specified and directed (upto 4 storied bldg).
67All as per item No. 65 above but from 5 storied to 8 storied of building complete all as specified and as directed.
68S&F Anodised powder coated aluminum Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specifiedr and including dismantling of existing unserviceable Aluminium window complete all as specified and as directed by the Engr-in-Charge (upto 4 storied bldg).
69All as per item No. 67 above but from 5 storied to 8 storied of building complete all as specified and as directed.
70Supply and fixing in repair 18/19mm thick plywood with decorative laminated sheet (mica) fixed with waterproof adhesive to timber frame work including second class hard wood beading on cutting exposed edges complete all as specified and as directed. (upto 04 storey High of building)
71All as per item No. 69 above but from 5 storied to 8 storied of building complete all as specified and as directed.
72Supply and fixing decorative laminate sheet (mica) of 1.00 mm thickness fixed with waterproof adhesive to HDHMR board including necessary PVC edging (if required) complete all as specified and as directed. (upto 04 storey High of building)
73All as per item No. 71 above but from 5 storied to 8 storied of building complete all as specified and as directed.
74Supply and fixing 18mm thick high density, high moisture resistance board (HDHMR) including 2.00mm thick PVC edge bending fixed with screwes, solvent cement /adhesive to make modular kitchen cabinet and cupboard shutters or drawer including dismantling of old existing cabinet complete all as specified and directed. (upto 04 storey High of building)
75All as per item No. 73 above but from 5 storied to 8 storied of building complete all as specified and as directed.
76Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-incharge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) Note : Cutlery basket minimum wt. 1.50 kg, Plain basket minimum wt 2.00 kg, Thali or plate basket minimum wt 3.00 kg.
77All as per item No. 75 above but from 5 storied to 8 storied of building complete all as specified and as directed.
78Supply and fixing 6mm thick high density, high moisture resistance board (HDHMR) fixed with screwes, solvent cement /adhesive to make kitchen cabinet and cupboard shutters or drawer including dismantling of old existing cabinet complete all as specified and directed. (upto 04 storey High of building)
79All as per item No. 77 above but from 5 storied to 8 storied of building complete all as specified and as directed.
80S&F 5.50 mm thick sheet glass ordinary quality, frosted on one side fixed to aluminium frame work exc 0.5 Sq. m in each pane complete all as specified & as directed (upto 4 storied bldg).
81All as per item No. 79 above but from 5 storied to 8 storied of building complete all as specified and as directed.
82M&L for WPC perforated jali 25mm-30mm thick CNC cut , rounded hole of dia 12mm staggered type c/c spacing 25mm with necessary WPC frame fixing on beam and column with cleat and screws of required size including dismantling of old RCC jallies complete all as specified and as directed. (upto 04 storey High of building) Note:- Shape / Design of jallies as appoved by GE)
83All as per item No. 81 above but from 5 storied to 8 storied of building complete all as specified and as directed.
84S&F in repair sinks with drainage board made of stain less steel 1mm thick, kitchen with plugs, washer and wastes; Including bedding in cement mortor to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mmx160mm complete all as specified and as directed. (upto 12 storied bldg)
85S&F in repair sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes;including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.(upto 12 storied bldg)
86S&F magnetic door catcher of high quality stainless steel with strong permanent magnet for holding door in open or closed position complete all as specified & as directed. (upto 4 storied bldg).
87All as per item No. 85 above but from 5 storied to 8 storied of building complete all as specified and as directed.
88S&F aluminium 4 levers Mortice lock, vertical type, size 100 mm complete all as specified & as directed (upto 4 storied bldg).
89All as per item No. 87 above but from 5 storied to 8 storied of building complete all as specified and as directed.
90S&F Stainless steel handles 150mm long, bright polished Complete all as specified and as directed (upto 4 storied bldg).
91All as per item No. 89 above but from 5 storied to 8 storied of building complete all as specified and as directed.
92S&F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed (upto 4 storied bldg).
93All as per item No. 91 above but from 5 storied to 8 storied of building complete all as specified and as directed.
94S&F Stainless steel handles 200 mm long, bright polished Complete all as specified and as directed (upto 4 storied bldg).
95All as per item No. 93 above but from 5 storied to 8 storied of building complete all as specified and as directed.
96S&F 200mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed (upto 4 storied bldg).
97All as per item No. 95 above but from 5 storied to 8 storied of building complete all as specified and as directed.
98S&F Stainless steel 300mm long sliding door bolts with hasp stapple (bolt type) complete all as specified and as directed (upto 4 storied bldg).
99All as per item No. 97 above but from 5 storied to 8 storied of building complete all as specified and as directed.
100S&F 300mm long aluminium alloy, anodised sliding door bolt with hasp, staple (bolt type) and fixing clip of sheet,cast or extruded section and fixing bolt of extruded section or cast aluminium alloy and fixed complete all as specified and directed (upto 4 storied bldg).
101All as per item No. 99 above but from 5 storied to 8 storied of building complete all as specified and as directed.
102S&F Stainless steel barrel tower bolts of extruded section with 200 mm long bolt, complete all as specified and as directed (upto 4 storied bldg).
103All as per item No. 101 above but from 5 storied to 8 storied of building complete all as specified and as directed.
104S&F 200mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed (upto 4 storied bldg).
105All as per item No. 103 above but from 5 storied to 8 storied of building complete all as specified and as directed.
106S&F Stainless steel barrel tower bolts of extruded section with 150 mm long bolt, complete all as specified and as directed (upto 4 storied bldg).
107All as per item No. 105 above but from 5 storied to 8 storied of building complete all as specified and as directed.
108S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed (upto 4 storied bldg).
109All as per item No. 107 above but from 5 storied to 8 storied of building complete all as specified and as directed.
110S&F stainles steel bearing hinges 100mm, cast brass, with Stainless steel hinge pin, bright polished and fixed, typeB-11 complete all as specified and as directed (upto 4 storied bldg).
111All as per item No. 109 above but from 5 storied to 8 storied of building complete all as specified and as directed.
112S&F 100mm MS Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed (upto 4 storied bldg).
113All as per item No. 111 above but from 5 storied to 8 storied of building complete all as specified and as directed.
114S&F for Stainless steel wire cloth having 0.36 mm nominal dia of wire and average width of appreature 1.40 mm and fixed with stainless wire staples complete all as specified and as directed (upto 4 storied bldg).
115All as per item No. 113 above but from 5 storied to 8 storied of building complete all as specified and as directed.
116S&F in repair aluminium (extruded section) body door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed (upto 4 storied bldg).
117All as per item No. 115 above but from 5 storied to 8 storied of building complete all as specified and as directed.
118S&F floor door stopper overall length of cover plate 150mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and as directed (upto 4 storied bldg).
119All as per item No. 117 above but from 5 storied to 8 storied of building complete all as specified and as directed.
120S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), clamps; hold fasts; wall ties; and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed (upto 4 storied bldg).
121All as per item No. 119 above but from 5 storied to 8 storied of building complete all as specified and as directed.
122Dismantling floor , earth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises, all as specified (upto 4 storied bldg).
123All as per item No. 121 above but from 5 storied to 8 storied of building complete all as specified and as directed.
124M&L non-skid joint free ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.18sqm but n.exceeding 0.36 sqm in toilet/bath floor etc.set and jointed with adesive and pointed in epoxy grout with spacers including Screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed.(upto 4 storied bldg)
125All as per item No. 123 above but from 5 storied to 8 storied of building complete all as specified and as directed.
126M&L for glazed ceramic (coloured) tiles of size 450x300x6-7mm thick as in vertical surface/dado set and jointed in adesive and pointed in white or coloured cement to match over 10mm thick screed bed in CM (1:3) complete all as specified and directed.(upto 4 storied bldg)
127All as per item No. 125 above but from 5 storied to 8 storied of building complete all as specified and as directed.
128M&L for double charged Vitrified tiles 8-9 mm thick (Sqr/ rectangular) Polished, area of each tiles exc. 0.42 sqm but n.exc 1.00 sqm, in floors etc. set and jointed with adesive and pointed in epoxy grout with spacers complete all as specified and directed.(upto 4 storied bldg)
129All as per item No. 127 above but from 5 storied to 8 storied of building complete all as specified and as directed.
130M&L for double charged Vitrified ceramic tiles 9-10 mm thick (Sqr/ rectangular) Polished, area of each tiles exc. 0.42 sqm but n.exc 1.00 sqm, in skirting etc. set and jointed with adesive and pointed in epoxy grout with spacers including screed bed or bedding layer 10 mm thick in cement mortar (1:4) for laying floor finishes complete all as specified and directed.(upto 4 storied bldg)
131All as per item No. 129 above but from 5 storied to 8 storied of building complete all as specified and as directed.
132Dismantling of stone slabs and tiles of any description or thickness in floors,aprons etc laid, bedded & pointed in any mortar(upto 4 storied bldg).
133All as per item No. 131 above but from 5 storied to 8 storied of building complete all as specified and as directed.
134M & L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, indow-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed (upto 4 storied bldg).
135All as per item No. 133 above but from 5 storied to 8 storied of building complete all as specified and as directed.
136Mirror polishing on marble/granite/kota stone/stone work where-ever required to give high gloss finish complete all as specified and as directed. (upto 4 storied bldg).
137All as per item No. 135 above but from 5 storied to 8 storied of building complete all as specified and as directed.
138Rounding to edges of stone slabs one edge, such as in steps, cooking platform, window sill and other similar situations (upto 4 storied bldg).
139All as per item No. 137 above but from 5 storied to 8 storied of building complete all as specified and as directed.
140M&L for Machine cut kota stone slab flooring in stair case including riser and tread with single piece slab of 20-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, including over 20 mm thick screed bed in CM (1:6) all as specified and directed.(upto 4 storied bldg)
141All as per item No. 139 above but from 5 storied to 8 storied of building complete all as specified and as directed.
142M&L for screed bed or bedding layer of mortar 20 mm thick in CM (1:6) for laying floor finishes.(upto 4 storied bldg)
143All as per item No. 141 above but from 5 storied to 8 storied of building complete all as specified and as directed.
144Demolition of cement concrete above ground floor n.exe 15cm thickness(below or above ground level). (upto 4 storied bldg).
145All as per item No. 143 above but from 5 storied to 8 storied of building complete all as specified and as directed.
146M&L for 25mm thick cement concrete type B-0, (1:2:4) using 12.5mm graded aggregate complete all as specified (upto 4 storied bldg).
147All as per item No. 145 above but from 5 storied to 8 storied of building complete all as specified and as directed.
148M&L for PCC (1:5:10) Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floor complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
149All as per item No. 147 above but from 5 storied to 8 storied of building complete all as specified and as directed.
150Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster including backfilling of sunken. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency). Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm.( Fosroc/Elantas beck/Kunal conchem) ( Make : SIKA/FOSROC/Hindcon ) (upto 4 storied bldg).
151All as per item No. 149 above but from 5 storied to 8 storied of building complete all as specified and as directed.
152Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing etc., and making good, cutting not exc 10 cm girth (upto 4 storey bldg).
153All as per item No. 151 above but from 5 storied to 8 storied of building complete all as specified and as directed.
154Taking up or down 20mm bore steel water tubing and connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed (upto 4 storey bldg).
155All as per item No. 153 above but from 5 storied to 8 storied of building complete all as specified and as directed.
156Taking up or down 25mm bore steel water tubing and connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed (upto 4 storey bldg).
157All as per item No. 155 above but from 5 storied to 8 storied of building complete all as specified and as directed.
158Taking up or down 40mm bore steel water tubing and connections,including cleaning for removal to store(GI Pipe) complete all as specified and as directed (upto 8 storey bldg).
159Taking down UPVC pipe 50 mm bore with fittings complete all as specified and directed.(upto 8 storey bldg).
160Supply and fixing of rotational moulded polythene water storage tank 1000 litre capacity ISI marked (cylindrical, vertical, double layered with closed top) hoisted and fixed in position including PVC float valve 20mm bore weight not less than 210gms Complete including dismantling of old unserviceable water tank, removing from site.(8th storied bldg)
161All as per item No 159 above but capacity 2000 litre.(8th storied bldg)
162Dismantling of 110mm pvc (swr) pipes, jointed in cement mortar complete all as specified and directed (upto 4 storey bldg).
163All as per item No. 161 above but from 5 storied to 8 storied of building complete all as specified and as directed.
164S&F 20 mm bore (Outer dia) CPVC pipes of SDR 11and plain CPVC SDR 11 fitting fixed on wall or floor (concealed ), ceiling or laying in floors complete all as directed.(upto 4 storey bldg).
165All as per item No. 163 above but from 5 storied to 8 storied of building complete all as specified and as directed.
166S&F in 25 mm bore (Outer dia) CPVC pipes of SDR 13.5 and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as directed. (upto 4 storey bldg).
167All as per item No. 165 above but from 5 storied to 8 storied of building complete all as specified and as directed.
168S&F in 40 mm bore (Outer dia) CPVC pipes of SDR 13.5 and plain CPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as directed. (upto 8 storey bldg).
169S&F 50 mm bore (Outer dia) UPVC pipes of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors complete all as directed. (upto 8 storey bldg).
170Supply and installation of galvanized steel railing, fabicated from mild steel railing, fabricated from mild steel sections, hot and dip galvanized as per standard specifications, complete with all ftiitings, fixtures, welding, grinding and finishing including anchoring and installation at site complete in all respect as specified (upto 4 storey bldg).
171All as per item No. 169 above but from 5 storied to 8 storied of building complete all as specified and as directed.
172S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls (upto 4 storey bldg).
173All as per item No. 171 above but from 5 storied to 8 storied of building complete all as specified and as directed.
174S&F 20 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA)(upto 4 storey bldg).
175All as per item No. 173 above but from 5 storied to 8 storied of building complete all as specified and as directed.
176S&F 25 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA)(upto 4 storey bldg).
177All as per item No. 175 above but from 5 storied to 8 storied of building complete all as specified and as directed.
178S&F 20mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA)(upto 4 storey bldg).
179All as per item No. 177 above but from 5 storied to 8 storied of building complete all as specified and as directed.
180S&F 25mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA)(upto 4 storey bldg).
181All as per item No. 179 above but from 5 storied to 8 storied of building complete all as specified and as directed.
182S&F 40 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA)(upto 8 storey bldg).
183S&F 40 mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA)(upto 8 storey bldg).
184S&F 50 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA)(upto 8 storey bldg).
185S&F 50 mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA)(upto 8 storey bldg).
186S&F PVC (SWR) bends 110 mm dia (upto 8 storey bldg).
187S&F PVC (SWR) junction single, (Single T) equal or unequal 110 mm dia.(upto 8 storey bldg).
188S&F PVC (SWR) junction double, (Double T) equal or unequal 110 mm dia.(upto 8 storey bldg).
189S&F for 110mm dia PVC (SWR) vent cowl any radius complete all as specified and directed(upto 8 storey bldg).
190S&F Brass chromium plated brackets complete all as specified and directed(upto 8 storey bldg).
191Supply and Application of 5 Layer SHR Waterproofing Coating System as per manufacturer application procedure on leaking concrete roof surface by thorough surface preparation with high pressure water jet min. 125 bars, opening the cracks, followed by one absorption coat of nano-tech enhanced elastomeric waterproofing (NEEWP) emulsion having UV resistance and min. 50% solids, filling and sealing the cracks, then over coating with 2 Coats of NEEWP + Cement mixture as waterproofing coat having +450% Elongation. The surface is then to be tested for water tightness with ponding test for min. 2 days and then top-coated with 2 Coats of SHR Coating - pure acrylic based, UV resistant, non-yellowing, bio-organism resistant (anti-fungal, anti-bacterial) conforming to *BIS STD IS 17218:2019* with Pull off Adhesion 2.8 Mpa, passes *2500 hrs* accelerated durability test, SRI 102 and other tests as specified, suitable for all types of cementitious surfaces, white colour, matt, surface coverage 3.25 SQM/Ltr/2 Coats, DFT 120 +/- 20 microns using brush, roller, airless spray gun as applicable. The generic product should be GRIHA certified and tested at NABL approved lab. The application is to be done by company approved applicator only\\" (upto 8 storied bldg).
192S&F in repairs vitreous china squatting pan of “Orissa” pattern of size 580 mmx 440mm white with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified and as directed.(upto 4 storey bldg).
193All as per item No. 191 above but from 5 storied to 8 storied of building complete all as specified and as directed.
194Preparing surfaces of wood and wood based materials, steel and iron work, new or old, of any description and girth, not otherwise described, and treated with tar or coal tar black paint areatarred exc 0.1 sq. m but n exc 0.5 sq. m each complete all as specified and directed.(upto 4 storey bldg)
195All as per item No. 193 above but from 5 storied to 8 storied of building complete all as specified and as directed.
196S&F in repairs vitreous china wash hand basin, white, flat back, size 550mm x 400mm, exc chain and plug and porcelain stopper but including cutting for and pinning in ends of and including brackets, waste pipe & CP brass waste coupling of 32mm dia complete all as specified and directed.(upto 4 storey bldg).
197All as per item No. 195 above but from 5 storied to 8 storied of building complete all as specified and as directed.
198S&F in repairs 32mm Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed(upto 4 storey bldg).
199All as per item No. 197 above but from 5 storied to 8 storied of building complete all as specified and as directed.
200S & F in repairs 15 mm Dia CP angular cock , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed . (upto 4 storey bldg).
201All as per item No. 199 above but from 5 storied to 8 storied of building complete all as specified and as directed.
202S&F 15mm bore in repair Brass CP bib cock with crutch or butterfly handle chromium plated complete in all respect as specified.(upto 4 storey bldg).
203All as per item No. 201 above but from 5 storied to 8 storied of building complete all as specified and as directed.
204S&F in auto hinges/slip on cabinet hinges by making adequate hole in 18 mm board from inside and fixed to cupoard shutter and frame by screw, complete all as specified and as directed.(upto 04 storey High of building) Make:- Hettich/Godrej/Hafele
205All as per item No. 203 above but from 5 storied to 8 storied of building complete all as specified and as directed.
206S & F in repairs 15 mm Dia CP stop cock(concealed type) , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed .(upto 4 storey bldg).
207All as per item No.205 above but from 5 storied to 8 storied of building complete all as specified and as directed.
208S&F in repairs 15 mm bore CP single lever basin mixer with 305 mm extended body and 600mm braided connection pipe, screwed down for pipe, high pressure ,complete all as specified and directed.(Make:-Cera or Equivalent) (upto 4 storey bldg).
209All as per item No. 207 above but from 5 storied to 8 storied of building complete all as specified and as directed.
210S & F in repairs 25 mm Dia brass gun metal gate valve , with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed . (upto 4 storey bldg).
211All as per item No. 209 above but from 5 storied to 8 storied of building complete all as specified and as directed.
212S&F in repairs Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.(Make:-Cera Cat-2024, Cat No-F1018402 or Equivalent) (upto 4 storey bldg).
213All as per item No. 211 above but from 5 storied to 8 storied of building complete all as specified and as directed.
214S&F in repair 15 mm bore CP Sink mixture swan neck long complete all as specified and directed. (upto 4 storey bldg).
215All as per item No. 213 above but from 5 storied to 8 storied of building complete all as specified and as directed.
216S&F in repairs Health faucet mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mtr long flexible tube and wall hook including making connections and fixed in position complete in all respect as specified.
217All as per item No. 215 above but from 5 storied to 8 storied of building complete all as specified and as directed.
218S&F in repair 600 mm PVC connection pipe 15 mm size with PTMT nut of following length complete all as specified and directed .(upto 4 storey bldg)
219All as per item No. 217 above but from 5 storied to 8 storied of building complete all as specified and as directed.
220S & F in repair 90/110 mm floor trap fixed in floor with grating incl jointing with solvent 1:2:4 cement concrete,complete all as spd and directed(upto 4 storey bldg)
221All as per item No. 219 above but from 5 storied to 8 storied of building complete all as specified and as directed.
222S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete in all respect as specified and directed.(upto 12 storey High of building)
223All as per item No. 221 above but from 5 storied to 8 storied of building complete all as specified and as directed.
224S&F in repair brass CP Shower roses in repair with or without swivel joints, 125mm size, including fixing to steel pipes or union complete in all respect as specified.(upto 4 storey bldg)
225All as per item No.223 above but from 5 storied to 8 storied of building complete all as specified and as directed.
226S&F in repairs Chromium plated Soap dish, fixed to plugs with chromium plated brass screws complete in all respect as specified. (upto 12 storey High of building)(upto 4 storey bldg)
227All as per item No. 225 above but from 5 storied to 8 storied of building complete all as specified and as directed.
228S&F in replacement stainless steel curtain rails with decorative type drappery Rod along with dooms and all fittings of 25 mm dia complete all as specfied and directed. (upto 4 storey bldg)
229All as per item No. 227 above but from 5 storied to 8 storied of building complete all as specified and as directed.
230S&F in repair brass CP Tubular towel rack, 600 mm long between flanges complete all as specfied and directed.(Make:-Cera or Equivalent) (upto 4 storey bldg)
231All as per item No. 229 above but from 5 storied to 8 storied of building complete all as specified and as directed.
232S&F in repair PVC valveless, symphonic action type low level flushing cistern white with inlet ball valve, float and handle including brackets, 10 ltr capacity complete with flush pipe(Long bend) 32mm dia of make as approved by GE complete all as specified & directed. (upto 4 storey bldg)
233All as per item No. 231 above but from 5 storied to 8 storied of building complete all as specified and as directed.
234S&F UPVC louvers type ventilator assembled partially with PVC exhaust fan of 200mm sweep and partially fixed with frosted glass of area n.exc 0.5 sqm including all necessary fittings complete all as specified and directed (upto 4 storied bldg) .
235All as per item No. 233 above but from 5 storied to 8 storied of building complete all as specified and as directed.
236S&F brass in repair CP toilet Paper Holder with flap guard complete all as specfied and directed.(Make:-Cera or Equivalent)(upto 4 storey bldg)
237All as per item No. 235 above but from 5 storied to 8 storied of building complete all as specified and as directed.
238S&F Corner glass shelf with 2 racks complete all as specfied and directed.(Make:-Cera or Equivalent)(upto 4 storey bldg)
239All as per item No. 237 above but from 5 storied to 8 storied of building complete all as specified and as directed.
240Providing and fixing stainless steel peg set (six pin) including all necessary fittings complete all as per manufacturer's instructions and all as specified and as directed by the Engr-in-Charge.(upto 4 storey bldg)
241All as per item No. 239 above but from 5 storied to 8 storied of building complete all as specified and as directed.
242S&F Stainless Steel Silver chrome Door Handle 100mm long, suitable for fixing of Brass screws inside of the board etc, complete all as specified and as directed.(upto 04 storey High of building)
243All as per item No. 241 above but from 5 storied to 8 storied of building complete all as specified and as directed.
244S&F in repairs 15 mm bore CP pillar taps, with capstan heads, chromium plated, Fancy type screwed down for pipe, high pressure ,complete all as specified and directed.(upto 12 storey High of building)
245All as per item No. 243 above but from 5 storied to 8 storied of building complete all as specified and as directed.
246Dismantling of roof tiling including cement mortar bedding and remove the tiles/rubbish outside the MOD land, complete all as specified and as directed. (upto 8 storied bldg).
247Demolition of cement concrete on roof n.exe 15cm thickness and remove the malba/rubbish outside the MOD land, complete all as specified and as directed. (upto 8 storied bldg).
248Taking out/Stripping of old Roof treatment membranes/Tar felt incl layer of cement mortar of any thickness type carefully from roof surfaces (without damaging roof ) and incl preparation of old roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust & receive new treatment and removing rubbish from MOD land complete all as specified and directed. (8th storied bldg)
249Material and labour for carry out waterproofing treatment to sound, moisture free concrete surface using Nitoproof 600PF - Liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm. System includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound etc., and application of Nitoproof WB Primer, Water dispersible epoxy primer followed by two coats of Nitoproof 600PF coverage @ 2.0 kg/m2 to achieve 1.5 mm WFT in two coats followed by laying of separation layer of 120 gsm non-woven geotextile layer before carry out protection screed etc. complete including all tools and tackles as per manufacturer’s specification. Nitocote 600PF cured material shall be having crack bridging of 2 mm, Elongation (ASTMD 412) – >600 %, Tensile Strength (ASTM D412) –2.5 N/mm2, Recovery from Elongation (ASTM D412) – 95 %, 85% Solid Content, Tear Resistance (ASTM D624) – 15 Kn/m, Shore A Hardness (ASTM D2240) – 60, Water vapour transmission- 0.6 g/m2/hr, Water Permeability @ 5 Bar (BS EN 12390)-Nil, Service Temperature – -40°C to 70°C, Flash Point > 70 °C, Viscosity-60p, Specific Gravity-1.5. The item rate shall be including of all kinds of labour, tools & tackle, machineries, lead & lift, mathadi charges, curing, wastages, consumable, cleaning, shifting of debris outside the site premises, surface preparation, etc. complete as per design, drawing & instructions of EIC. Cost of 120 gsm non-woven geotextile and 40mm Screed concrete Shall be paid separately. (8th storied bldg)
250Supply & Laying Geotextiles of 120 Gsm over the waterproofing coating to avoid damage during screed casting complete as per specification and as directed. (8th storied bldg)
251Supply & laying of maximum 40 mm thick (at RW outlet) protective screed over the waterproof coating at proportion of (1:2:4) admixed with suitable integral waterproofing compound conforming IS 2645:2003 @ 200ml per bag of cement and reinforced with PP fibres with proper slope towards RW pipes. Green stage saw cutting on the screed will be done in panels (3m X 3m) with a groove size of 10mm X 15mm Complete as per specification and as directed. (8th storied bldg)
252Taking down old rusted u/s steel collapsible gates or rolling shutters any size including taking out holdfasts/anchorages and other fixtures complete all as specified complete all as specified and directed.(8th storied bldg)
253S&F collapsible steel gates, top hung consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with hold fasts and brackets, complete all as specified and directed.(8th storied bldg)
254Dismantling of old Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings compete all as specified.(upto 4 storey bldg)
255All as per item No. 253 above but from 5 storied to 8 storied of building complete all as specified and as directed.
256Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.(upto 4 storey bldg)
257All as per item No. 255 above but from 5 storied to 8 storied of building complete all as specified and as directed.
258S&F for Pre painted galvalume aluminium zinc coating GI based corugated steel sheet 0.50mm thick Hi-Rib colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.(upto 4 storey bldg)
259All as per item No. 257 above but from 5 storied to 8 storied of building complete all as specified and as directed.
260S & F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Confirming to IS-1161-1979, Gde-E-250 quality-A complete all as specified and directed.(upto 4 storey bldg)
261All as per item No. 259 above but from 5 storied to 8 storied of building complete all as specified and as directed.
262S & F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes of Fe 410-W (Gde-E250) quality-A complete all as specified and directed.(upto 4 storey bldg)
263All as per item No. 261 above but from 5 storied to 8 storied of building complete all as specified and as directed.
264S & F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
265All as per item No. 263 above but from 5 storied to 8 storied of building complete all as specified and as directed.
266M&L for Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete as specified and directed.(upto 4 storey bldg)
267All as per item No. 265 above but from 5 storied to 8 storied of building complete all as specified and as directed.
268Material and labour for Providing cement concrete type B-1 1:2:4 (using 12.5 mm graded stone aggregate) as in benching concrete,coping etc complete all as specified and directed.(upto 8 storey bldg)
269Complete removal of existing treatment by using electric sander machine or steel wire brushing to remove all dust and loose scale etc of wall surfaces & prepare to receive wall care putty complete all as specified & directed.(upto 4 storey bldg)
270All as per item No. 268 above but from 5 storied to 8 storied of building complete all as specified and as directed.
271M&L for preparation of new plastered surfaces of wall and applying two coat of acrylic distemper over a coat of primer over 2 mm thick wall care putty complete in all respect as specified.(upto 04 storey High of building).
272All as per item No. 270 above but from 5 storied to 8 storied of building complete all as specified and as directed.
273M&L for preparation of old plastered surfaces of wall and applying two coat of acrylic distemper over a coat of primer over 2 mm thick wall care putty complete in all respect as specified.(upto 04 storey High of building).
274All as per item No. 272 above but from 5 storied to 8 storied of building complete all as specified and as directed.
275M&L for preparation of new plastered surfaces of ceiling and applying two coat of acrylic distemper over a coat of primer over 2 mm thick wall care putty complete in all respect as specified.(upto 04 storey High of building).
276All as per item No. 274 above but from 5 storied to 8 storied of building complete all as specified and as directed.
277M&L for complete removal of old plastered surfaces of ceiling and applying two coat of acrylic distemper over a coat of primer over 2 mm thick wall care putty complete in all respect as specified.(upto 04 storey High of building).
278All as per item No. 276 above but from 5 storied to 8 storied of building complete all as specified and as directed.
279Material & Labour for applying Two coats of 100% Premium acrylic exterior emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and as directed.(upto 4 storey bldg)
280All as per item No. 278 above but from 5 storied to 8 storied of building complete all as specified and as directed.
281Material & Labour for Complete removal of existing treatment by using electric sander machine or steel wire brushing to remove all dust and loose scale etc of wall surfaces and applying Two coats of 100% Premium exterior acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces complete all as specified and as directed.(upto 4 storey bldg)
282All as per item No. 280 above but from 5 storied to 8 storied of building complete all as specified and as directed.
283M&L for preparing of new steel surfaces & applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and as directed(upto 4 storey bldg).
284All as per item No. 282 above but from 5 storied to 8 storied of building complete all as specified and as directed.
285M&L for Two coats of synthetic enamel paint on New wooden surface exc 10cm width or girth including preparation complete all as specified and as directed(upto 4 storey bldg).
286All as per item No. 284 above but from 5 storied to 8 storied of building complete all as specified and as directed.
287Supply only Intregal water proofing compound(upto 8 storey bldg).
288S&F Stainless steel handles 100mm long, bright polished complete all as specified .(upto 4 storied bldg)
289All as per item No. 287above but from 5 storied to 8 storied of building complete all as specified and as directed.
290S&F magnet catcher fixed in cabnet shutter (one portion) and wooden frame (other portion) with screw complete all as specified and directed.(upto 4 storied bldg)
291All as per item No. 289 above but from 5 storied to 8 storied of building complete all as specified and as directed.
292S&F Continuous (Piano) hinges, mild steel, bright finished or electro galvanized, width of flaps (When open) 30 mm at any storey of building complete all as specified & as directed. (upto 04 storey High of building)
293All as per item No. 291 above but from 5 storied to 8 storied of building complete all as specified and as directed.
294Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per direction of Engineer- in-charge.
295All as per item No. 293 above but from 5 storied to 8 storied of building complete all as specified and as directed.
296S&F 32 mm PVC waste pipe 900 mm long with complete all as specified.(upto 08 storey High of building)
297S&F waste coupling of PTMT (half or full threaded) bore dia of 40mm (Minimum weight 32mm- 45gms/40mm-60 gms)(upto 08 storey High of building).
298S&F in repair 450 mm PVC connection pipe 15 mm size with PTMT nut of following length complete all as specified and directed .(upto 4 storey bldg)
299All as per item No. 297 above but from 5 storied to 8 storied of building complete all as specified and as directed.
300M&L for non-skid ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.11 sqm but n.exceeding 0.18 sqm in floor etc.set and jointed with adesive and pointed in epoxy grout with spacers over screed bed 15 mm(1:6) complete all as specified & as directed incl .(upto 4 storied bldg)
301All as per item No. 299 above but from 5 storied to 8 storied of building complete all as specified and as directed.
302M&L non-skid ceramic (coloured) tiles 7-8mm thick area of each tiles exeeding 0.11sqm but n.exceeding 0.18 sqm in skirting etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match over screed bed 10 mm(1:4) complete all as specified & as directed.(upto 4 storied bldg)
303All as per item No. 301 above but from 5 storied to 8 storied of building complete all as specified and as directed.
304S&F 15 mm bore CPVC Male Brass Threaded Adaptor (MTA/ MBTA).(upto 08 storey High of building)
305S&F 15 mm bore CPVC Female Brass Threaded Adaptor (FTA/ FBTA).(upto 08 storey High of building)
306Dismantling of 75 mm pvc (swr) pipes jointed in cement mortar and taking out of trenches, if required .(upto 08 storey High of building)
307S&F 75mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete in all respect as specified.(upto 08 storey High of building)
308S&F 75mm bore PVC(SWR) pipe bend single socket complete in all respect as specified.(upto 08 storey High of building)
309S&F PVC (SWR) 75 mm bore junction single, (Single T) equal or unequal complete in all respect as specified.(upto 08 storey High of building)
310S&F for 75mm dia PVC (SWR) vent cowl any radius complete all as specified and directed. (upto 08 storey High of building)
311S&F in repair stainless steel kitchen rack / plate rack of size 36\\"x31\\"x10\\" , made of stainless steel sheet 0.63 mm thick etc complete all as specified and as directed by Engineer-in-charge.(upto 08 storey High of building)
312M&L for Machine cut kota stone slab flooring 20-22mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete, including over 20 mm thick screed bed in CM (1:6) all as specified and directed.(upto 4 storied bldg)
313(Spcl Item Part)S&F in repairs one piece EWC (640 X 350 X725 mm) Snow white, with slim soft close seat cover and S-Trap 220 mm , including connection to drain ( or outgoing pipe) complete complete all as specified. (Make:-Cera Cat-2024, Cat No-S1013208VS or Equivalent)(upto 4 storey bldg).
314All as per item No. 312 above but from 5 storied to 8 storied of building complete all as specified and as directed.
315S & F in repairs 15 mm Dia CP Bib taps (Two-in-one), with wall flange and aerator ,fancy type with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed . (Make:-Cera Cat-2024, Cat No-F1018163 or Equivalent) (upto 4 storey bldg).
316All as per item No. 314 above but from 5 storied to 8 storied of building complete all as specified and as directed.
317S&F wall mounted foldable cloth dryer/rack made of high-quality stainless steel with rust-proof finish, suitable for indoor and outdoor use. The dryer shall consist of multiple drying rods with sturdy wall mounting brackets, capable of carrying wet clothes load without bending or deformation. The unit shall be foldable/sliding type for space-saving operation and easy handling including all necessary fittings complete all as specified and directed.(upto 4 storey bldg)
318All as per item No. 316 above but from 5 storied to 8 storied of building complete all as specified and as directed.
319Providing and applying 2 coats of high-quality acrylic emulsion-based texture paint on prepared wall surfaces,ceiling surfaces etc including surface cleaning, putty application, primer coat, and creation of approved textured finish using suitable tools and materials. The work shall include all labor, materials, scaffolding, surface preparation, application of texture coat, finishing coat, curing, and cleaning complete as per manufacturer’s specifications and engineer-in-charge approval.(upto 04 storey High of building)
320All as per item No. 318 above but from 5 storied to 8 storied of building complete all as specified and as directed.
321M&L for 2mm thick wall care putty on external wall including rubbing with sand paper to achieve a smooth surface & sharp straight edges etc. complete all as specified & as directed.(upto 4 storied bldg).
322All as per item No.320 above but from 5 storied to 8 storied of building complete all as specified and as directed.
323Dismantling of stone slabs and tiles of any description or thickness in floors,aprons etc laid, bedded & pointed in any mortar(upto 4 storied bldg).
324All as per item No. 322 above but from 5 storied to 8 storied of building complete all as specified and as directed.
325M&L for green marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade complete all as specified and directed (upto 4 storied bldg).
326All as per item No. 324 above but from 5 storied to 8 storied of building complete all as specified and as directed.
327(Road Path Culvert Part)M&L for 60 mm thick machine pressed precast interlocking paver block of M-35 Grade any shape and size with grey cement and pigment confirming to IS 15658-2006 complete all as spd and directed.
328Material and labour for pre-polished cement concrete designed coloured chequered tiles glossy finish of area n exc 0.16 sqm as in floor set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of the tiles and laid over and including 15 mm thick screed bed in cement mortar (1:6) over 40mm PCC (1:2:4) type B-0, complete all as specified and as directed.
329M&L PCC (1:4:8) type D-2 (using 40mm graded aggregate) as in sub base complete all as specified and as directed.
330Hard core of gauge in exc. 63mm broken stone boulders deposited and spred and leveled in layers in.exc. 15mm thick complete all as specified and directed.
331M&L for sand filling under floor or in floor or paving, laid in including watering and consolidation true surface for laying paver block.
332M&L for precast cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) kerbs stone rounded or chamfered on edges as in edge of path, hard standing built in cement mortar (1:6) complete all as specified and as directed.
333(E/M Part)Taking down carefully aluminium/copper point wiring (light/fan/bell/socket /power) with complete fittings such as steel terminal boxes, switches, ceiling roses, pendents, regulators, sockets etc and removing the material including making good the distrubed surfaces of the wall flooring ceiling etc to match the existing surface all as specified and directed by Engr-in-Charge.
334M&L for concealed point wiring complete with stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable drawn through concealed PVC conduit and including replacement of unserviceable pressed steel terminal boxes with Modular steel terminal boxes factory made including white cover modular plate with frame suitable for modular switches, modular sockets, modular fan regulators etc of required size complete including 1.5 sqmm copper cable earth continuity wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one 5 Amp switch one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing) .Note :- The rate is inclusive cutting/chasing and making good disturbed surface with CM 1:3 and same surface finishs with the adjoining surface of disturbed area with OBD/Colour wash/white wash complete.
335All as per item No 333 above but 5 Amp socket outlet on same board.
336All as per item No 333 above One socket outlet 5 Amps on independent board.
337All as Item No 333 above but for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing complete.
338All as Item No. 333 above but for one light point controlled by two 2-way switches with cable 1.5 Sqmm size.
339M&L for concealed point wiring complete with stranded copper conductor 4 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable drawn through concealed PVC conduit complete including 4 sqmm copper cable earth continuity wire to common earth and connected to earth dolly complete all as specified for one socket outlet for modular AC Box on Independent board with cables 4.0 sqmm size for phase and neutral and 4 Sqmm for earthing complete. Note:- the rate is inclusive cutting /chasing and making good the disturbed surface with cm 1:3 and same surface finishes with the adjoining surface of disturbed area with OBD/colour wash/white wash complete
340S&F switch modular type, 1 way 6A, 1module.
341S&F switch, Modular switch 2 way 6A, 1 module.
342S&F Modular Socket, 6A - 2/3 pin 2 module.
343S&F switch modular type 1way 16A, 1module with indicator
344S&F Socket 6A/16A - 2/3 pin combined .
345S&F Modular Bell push 6A 1 module
346S & F in replacement ,Decorative wall light mounting suitable for LED Lamp upto 15 Watt complete with all connections all as specified and directed. Make :- Crompton Model no WALLGLOW-C-E27 or equivalent in Havells, Phillips.
347S&F in replacement Wall mounted LED Integrated Batten features a durable extrudex aluminium body IP40, 20 Watt - 4Ft White, indoor decorative LED battern complete all as specified and as directed. Make :- Crompton Model CCC-100-20-65-HL2-DP-NWE or equivalent in Havells, Phillips.
348S&F in replacement Wall mounted LED Integrated Batten 10 Watt-2 Ft White, indoor decorative PVC extruded LED batten, complete. Make :- Crompton Model CCS-103-10-65-SL-DP-NEW or equivalent in Havells, Phillips.
349S&F Modular AC starter unit consisting of one 25 Amp capacity starter with 2 module, complete all as specified and directed.
350S&F in replacement of lamp holder Angle/ Batten type bakelite insulated body with back plate all as specified and directed.
351S&F LED bulb 12 Watt complete all as specified and directed. Make of LED Bulb
352S&F of electric bell Ding Dong type AC, 230 volts single phase all as specified.
353S&F ceiling rose surface Bakelite 65x25mm two to three terminals complete all as specified.
354S&F in replacement of building security light fitting 35W LED 5000K new Powder coated pressure die cast aluminium compact LED Street light including pole of dia 40 mm of bracket duly fixed with clamps, nut, bolts & washers etc and all as directed.
355S&F in replacement of VTPN DB 4 way, 4Pole double door,415V vertical type for fixing MCCB up to 250 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as of approved make by the GE.
356S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used TPN, 4 Way, 240V complete as per site requirement and as directed by Engr-in charge.
357S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-12 Way, 240V complete as per site requirement and as directed by Engr-in charge.
358S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-08 Way, 240V complete as per site requirement and as directed by Engr-in charge.
359S&F in replacement of MCCB 3 Pole .415 V. fixed type, 250 Amps with breaking capacity 36kA all as directed.
360S&F in replacement MCB TPN 100 Amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc.
361S&F in replacement MCB SPN 40 to 63 Amps 'C' series, breaking capacity 10 Ka, 'C' curve 240 volts, 50 Hz including necessary incoming and out going electric connection with suitable size of copper lugs etc.
362S&F for MCB SP 63 Amps 240 Volts, 10kA, `C' curve all as per site requirement and as directed.
363S&F for MCB SP 6 to 32 Amps 240 Volts, 10kA, `C' curve all as per site requirement and as directed.
364M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI strip 32 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 40 mm dia upto 7.5 M, GI watering pipe 20 mm dia medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 5 of SSR Part I, including earth test point upto panel board, all as specified or indicated including testing on completion.
365Taking down and re fixing pre paid meter in meter box with consultation with pre paid meter authorities including necessary connections of incoming and out going cables for light and power as specified and directed by Engr-in-charge.
366Taking down unserviceable sub main wiring twin core of any size complete and making good disturbed surface complete all as specified and directed.
367M&L for Sub Main wiring using single run PVC Cable FRLS grade Insulated unsheathed, multistrand copper conductor cable 4 runs of 10 Sqmm for phase and neutral and 1 run of 10 Sqmm for earth wire drawn through concealed PVC conduit wiring in wall not less than 25mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and all as directed by Engr-in-charge. (Note:- Phase should be of Red /Yellow/Blue, neutral should be of back and earthing wire should be of green colour. 4 runs of cable for phase/ neutral and 1 run for earth will be measured and paid as one unit length).
368M&L for Sub Main wiring using single run PVC FRLS grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 06 Sqmm for phase and neutral and 1 run of 06 Sqmm for earth wire drawn through concealed PVC conduit wiring in wall not less than 25mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and all as directed by Engr-in-charge. (Note:- Phase should be of Red /Yellow/Blue, neutral should be of back and earthing wire should be of green colour. 2 runs of cable for phase/ neutral and 1 run for earth will be measured and paid as one unit length).
369M&L for Sub Main wiring using single run PVC FRLS grade Insulated unsheathed, multistrand copper conductor cable 2 runs of 04 Sqmm for phase and neutral and 1 run of 04 Sqmm for earth wire drawn through concealed PVC conduit wiring in wall not less than 25mm dia with all fittings like tees, bends, junction/ terminal boxes etc as per site requirement and all as directed by Engr-in-charge. (Note:- Phase should be of Red /Yellow/Blue, neutral should be of back and earthing wire should be of green colour. 2 runs of cable for phase/ neutral and 1 run for earth will be measured and paid as one unit length).
370S&F wall mounted fully automatic domestic type Electric chimney in size range from 60 cm to 90 cm hood for 2-4 gas burners of suction capacity 700-1200 mtr cube/hr, touch , gesture control, filterless autoclean including all connecting accessories,fitting and fixtures complete all as specified and directed by engr-in -charge..Note:- work for fitting of chimney including hole of suitable size for outlet will be done by contractor without any extra cost.
371S&F Exhaust Fan 250mm wall mounted high efficiency motor, strong air delivery, low noise operation,complete withsturdy Engineering plastic body with louvers shutter fixing with all connecting accessories, fitting and fixtures complete all as specified and directed by engr-in -charge.Note:- work for fitting of Ex Fan including hole of suitable size for outlet will be done by contractor without any extra cost.
372Supply, laying and testing cable XLPE insulated screened PVC bedded ,galvanised steel strip armoured ,electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size 16 sqmm, 4 core complete all as specified and directed by Engr-in-Charge.
373Taking Down of ceiling fan 1200/1400 mm sweep and re-fixing all fans must have 1.5 Sq mm copper cunductor multicore twin twisted wire of 01 Mtr length complete all as specified and as directed.
374Taking Down of Exhaust Fan 300mm Sweep and deposet to MES store yard complete all as specified and as directed.
375Taking Down of Geyser of capacity 25 ltrs and re-fixing all geyser must have 1.5 Sq mm copper cunductor multicore twin twisted wire of 01 Mtr length complete all as specified and as directed. complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57724576
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 4.64 Crore
LAST DATE 24-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Addn/Altn & special Repair Of Park View Offrs Md Accn At Comd Hosp (Ec) Complex Kolkata
Basic Detail
Tender No 89128/E8
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 26 Sep 2026
Submission Date 24 Oct 2026
Open Date 31 Oct 2026
Finance
Tender Value 4.64 Crore
Tender Fee 2000
EMD 5.39 Lakhs
Exemption Available
Document List
a7415c6d-47d6-4d2c-9830-650e4e03330a.html
BOQ_887195.xls
Tenderdocuments89128.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days
Oct 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 34 days

Tender Documents

Download All (ZIP) ↓
html

a7415c6d-47d6-4d2c-9830-650e4e03330a.html

xls

BOQ_887195.xls

pdf

Tenderdocuments89128.pdf

pdf

Tendernotice_1.pdf

Disclaimer