Tender For Rate Contract Of Cardiac Items
Tender Overview
Project Description
Tender for Rate Contract Of Cardiac Items , Rate Contract Of Cardiac Items :- , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiograp Hy Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Usfda/Pmda Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Ce Approved , · Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Dcgi Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Usfda/Pmda Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Ce Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Dcgi Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Usfda/Pmda Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Ce Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Dcgi Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System • Usfda /Pmda Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System • Ce-Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System Dcgi -Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle • Usfda /Pmda Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle • Ce- Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle Dcgi -Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Usfda /Pmda Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Ce-Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Dcgi - Approved • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Usfda/Pmda Approved , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Ce -Approved , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Dcgi - Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Usfda /Pmda Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Ce- Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Dcgi - Approved , Abdominal Aortic Aneurysm- Covered Stent • Usfda /Pmda Approved , Abdominal Aortic Aneurysm- Covered Stent • Ce - Approved , Abdominal Aortic Aneurysm- Covered Stent • Dcgi - Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Usfda /Pmda Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Ce - Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Dcgi - Approved , Covered Stent Grafts- Various Lengths And Diameter • Usfda /Pmda Approved , Covered Stent Grafts- Various Lengths And Diameter • Ce - Approved , Covered Stent Grafts- Various Lengths And Diameter • Dcgi - Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Usfda /Pmda Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Ce - Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Dcgi - Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Usfda /Pmda Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Ce Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Dcgi - Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal Usfda/Pmda Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal • Ce - Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal • Dcgi - Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Usfda/Pmda Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Ce- Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Dcgi - Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Usfda/Pmda Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Ce -Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Dcgi - Approved , • Ivc Filter • Various Sizes • With All Accessories • Usfda/Pmda Approved , • Ivc Filter • Various Sizes • With All Accessories • Ce -Approved , • Ivc Filter • Various Sizes • With All Accessories • Dcgi - Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Usfda/Pmda Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Ce -Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Dcgi - Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Usfda/Pmda Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Ce -Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Dcgi- Approved , • Inj. Tirzepatide • Usfda/Pmda Approved , • Inj. Tirzepatide • Ce -Approved , • Inj. Tirzepatide • Dcgi- Approved , • Inj. Cangrelor • Usfda/Pmda Approved , • Inj. Cangrelor • Ce -Approved , • Inj. Cangrelor • Dcgi- Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Usfda/Pmda Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Ce -Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Dcgi- Approved , Coronary Covered Stent
BOQ
| Sl. No. | Item Description |
| 1 | RATE CONTRACT OF CARDIAC ITEMS :- |
| 2 | • Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy.• Inner diameter of 4 Fr.= 1.03 mm, 5Fr. = 1.20 mm, 6 Fr.=1.30 mm or more with flow rates of 12, 21,25 ml per second respectively. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiograp hy catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) Amplatz left & right, (AL1 & 2, AR 1 & 2) multipurpose, hockey stick, IMA, pigtail- 4Fr.-5Fr.-6Fr.• USFDA/PMDA approved |
| 3 | • Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Inner diameter of 4 Fr.= 1.03 mm, 5Fr. = 1.20 mm, 6 Fr.=1.30 mm or more with flow rates of 12, 21,25 ml per second respectively. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) Amplatz left & right, (AL1 & 2, AR 1 & 2) multipurpose, hockey stick, IMA, pigtail- 4Fr.-5Fr.-6Fr. • CE approved |
| 4 | · Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy • Inner diameter of 4 Fr.= 1.03 mm, 5Fr. = 1.20 mm, 6 Fr.=1.30 mm or more with flow rates of 12, 21,25 ml per second respectively. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) Amplatz left & right, (AL1 & 2, AR 1 & 2) multipurpose, hockey stick, IMA, pigtail- 4Fr.-5Fr.-6Fr. • DCGI approved |
| 5 | PTFE Angiography Wire • Guide wire with V stick, with choice of stainless steel core or nitinol core • Must have 250 cm to 300 cm of length and .018” to .038” diameter • With silicon coated tip and bevel indicator • USFDA/PMDA approved |
| 6 | PTFE Angiography Wire • Guide wire with V stick, with choice of stainless steel core or nitinol core • Must have 250 cm to 300 cm of length and .018” to .038” diameter • With silicon coated tip and bevel indicator • CE approved |
| 7 | PTFE Angiography Wire • Guide wire with V stick, with choice of stainless steel core or nitinol core • Must have 250 cm to 300 cm of length and .018” to .038” diameter • With silicon coated tip and bevel indicator • DCGI approved |
| 8 | Two port manifold set with pressure line 200 cm, luer lock 10cc syringe and IV set.• USFDA/PMDA approved |
| 9 | Two port manifold set with pressure line 200 cm, luer lock 10cc syringe and IV set.• CE approved |
| 10 | Two port manifold set with pressure line 200 cm, luer lock 10cc syringe and IV set.• DCGI approved |
| 11 | Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters )With delivery system • USFDA /PMDA approved |
| 12 | Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters )With delivery system • CE-approved |
| 13 | Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters ) With delivery systemDCGI -approved |
| 14 | Pediatric FemoralSheath 4 Fr. • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • 0.21’’ Guide wire compatible • Diameter: 4 Fr • Lengths: 11 cm • with 21G needle • USFDA /PMDA approved |
| 15 | Pediatric FemoralSheath 4 Fr.• Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock• Optimized catheter manoeuvrability with minimal leakage• Cannula made of two (thinner) layers of polyethylene• Color codes for easy french size identification• 0.21’’ Guide wire compatible• Diameter: 4 Fr• Lengths: 11 cm • with 21G needle• CE- approved |
| 16 | Pediatric FemoralSheath 4 Fr.• Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock• Optimized catheter manoeuvrability with minimal leakage• Cannula made of two (thinner) layers of polyethylene• Color codes for easy french size identification• 0.21’’ Guide wire compatible• Diameter: 4 Fr• Lengths: 11 cm • with 21G needleDCGI -approved |
| 17 | Catheters for paediatric intervention • Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy.• Inner diameter of 4 Fr.= 1.03 mm, • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) multipurpose, IMA, pigtail- 4Fr.• USFDA /PMDA approved |
| 18 | Catheters for paediatric intervention • Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy.• Inner diameter of 4 Fr.= 1.03 mm, • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) multipurpose, IMA, pigtail- 4Fr.• CE-approved |
| 19 | Catheters for paediatric intervention • Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) multipurpose, IMA, pigtail- 4Fr.• DCGI - approved• The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy.• Inner diameter of 4 Fr.= 1.03 mm, • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. |
| 20 | INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titanium nitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (2-4 mm)• USFDA/PMDA approved |
| 21 | INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titanium nitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (2-4 mm)• CE -approved |
| 22 | INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titanium nitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (2-4 mm)• DCGI - approved |
| 23 | Micropuncture set needle set 5F 7Cm needle• USFDA /PMDA approved |
| 24 | Micropuncture set needle set 5F 7Cm needle• CE- approved |
| 25 | Micropuncture set needle set 5F 7Cm needle• DCGI - approved |
| 26 | Abdominal aortic aneurysm- covered stent • USFDA /PMDA approved |
| 27 | Abdominal aortic aneurysm- covered stent• CE - approved |
| 28 | Abdominal aortic aneurysm- covered stent • DCGI - approved |
| 29 | Abdominal aortic aneurysm- non covered stent • USFDA /PMDA approved |
| 30 | Abdominal aortic aneurysm- non covered stent• CE - approved |
| 31 | Abdominal aortic aneurysm- non covered stent• DCGI - approved |
| 32 | Covered stent grafts- various lengths and diameter • USFDA /PMDA approved |
| 33 | Covered stent grafts- various lengths and diameter• CE - approved |
| 34 | Covered stent grafts- various lengths and diameter• DCGI - approved |
| 35 | Non Covered stent grafts- various lengths and diameter• USFDA /PMDA approved |
| 36 | Non Covered stent grafts- various lengths and diameter• CE - approved |
| 37 | Non Covered stent grafts- various lengths and diameter• DCGI - approved |
| 38 | Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• USFDA /PMDA approved |
| 39 | Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• CE approved |
| 40 | Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• DCGI - approved |
| 41 | • IVL. Catheter and Connector cable • Intravascular lithotripsy intuitive catheter with Rx system for treating highly Calcified lesions• Integrated 12mm SC balloon • NP- 6 ATM • RBP – 10ATM• Diameter – 2.5,3.0,3.5,4.0mm• 2 Emitters( 80 Pulses per Catheter )• Registry with minimum 300 patients published in a peer reviewed journal USFDA/PMDA approved |
| 42 | • IVL. Catheter and Connector cable • Intravascular lithotripsy intuitive catheter with Rx system for treating highly Calcified lesions• Integrated 12mm SC balloon • NP- 6 ATM • RBP – 10ATM• Diameter – 2.5,3.0,3.5,4.0mm• 2 Emitters( 80 Pulses per Catheter )• Registry with minimum 300 patients published in a peer reviewed journal• CE – approved |
| 43 | • IVL. Catheter and Connector cable • Intravascular lithotripsy intuitive catheter with Rx system for treating highly Calcified lesions• Integrated 12mm SC balloon • NP- 6 ATM • RBP – 10ATM• Diameter – 2.5,3.0,3.5,4.0mm• 2 Emitters( 80 Pulses per Catheter )• Registry with minimum 300 patients published in a peer reviewed journal• DCGI - approved |
| 44 | • Mitral Clip • Trans catheter edge to edge repair (TEER) System• Cobalt chromium covered with polyester fabric and national graspers • Clip arm- 3-7 mm• Clip arm length – 9 and 12 mm • With guide catheter and delivery system and all accessories • USFDA/PMDA approved |
| 45 | • Mitral Clip • Trans catheter edge to edge repair (TEER) System• Cobalt chromium covered with polyester fabric and national graspers • Clip arm- 3-7 mm• Clip arm length – 9 and 12 mm • With guide catheter and delivery system and all accessories • CE- approved |
| 46 | • Mitral Clip • Trans catheter edge to edge repair (TEER) System• Cobalt chromium covered with polyester fabric and national graspers • Clip arm- 3-7 mm• Clip arm length – 9 and 12 mm • With guide catheter and delivery system and all accessories • DCGI - approved |
| 47 | • Tricuspid valve- THV• Balloon expandable THV system• Hybrid honey comb cell design• Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 mm • 14 Fr Python sheath • Navigator THV delivery system • Mammoth predication balloon • Crimping tool • USFDA/PMDA approved |
| 48 | • Tricuspid valve- THV• Balloon expandable THV system• Hybrid honey comb cell design• Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 mm • 14 Fr Python sheath • Navigator THV delivery system • Mammoth predication balloon • Crimping tool • CE -approved |
| 49 | • Tricuspid valve- THV• Balloon expandable THV system• Hybrid honey comb cell design• Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 mm • 14 Fr Python sheath • Navigator THV delivery system • Mammoth predication balloon • Crimping tool • DCGI - approved |
| 50 | • IVC filter • Various sizes • With all accessories • USFDA/PMDA approved |
| 51 | • IVC filter • Various sizes • With all accessories • CE -approved |
| 52 | • IVC filter • Various sizes • With all accessories • DCGI - approved |
| 53 | • Peripheral drug coated balloon • 0.035” Compatible • Diameter 4 to 6 mm • Length 60-150mm• USFDA/PMDA approved |
| 54 | • Peripheral drug coated balloon • 0.035” Compatible • Diameter 4 to 6 mm • Length 60-150mm• CE -approved |
| 55 | • Peripheral drug coated balloon • 0.035” Compatible • Diameter 4 to 6 mm • Length 60-150mm• DCGI - approved |
| 56 | • Inj. Iodixanol 100 ml• Iso- osmolar, Non ionic, dimeric, iodine containing contrast agent• USFDA/PMDA approved |
| 57 | • Inj. Iodixanol 100 ml• Iso- osmolar, Non ionic, dimeric, iodine containing contrast agent• CE -approved |
| 58 | • Inj. Iodixanol 100 ml• Iso- osmolar, Non ionic, dimeric, iodine containing contrast agent• DCGI- approved |
| 59 | • Inj. Tirzepatide• USFDA/PMDA approved |
| 60 | • Inj. Tirzepatide • CE -approved |
| 61 | • Inj. Tirzepatide • DCGI- approved |
| 62 | • Inj. Cangrelor• USFDA/PMDA approved |
| 63 | • Inj. Cangrelor• CE -approved |
| 64 | • Inj. Cangrelor• DCGI- approved |
| 65 | • Inj. Tirofiban 5 mg/ 100ml.• USFDA/PMDA approved |
| 66 | • Inj. Tirofiban 5 mg/ 100ml.• CE -approved |
| 67 | • Inj. Tirofiban 5 mg/ 100ml.• DCGI- approved |
| 68 | Coronary covered stent Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender