Educational and Research Institute Boards / Undertakings / PSU Closing in 21 days TDR #57724445

Tender For Rate Contract Of Cardiac Items

Issued by Boards / Undertakings / PSU · Udaipur, Rajasthan
Tender Value
2 Crore
Estimated cost
Bid Submission
21 Oct 2026
21 days left
EMD
4 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Udaipur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Rate Contract Of Cardiac Items , Rate Contract Of Cardiac Items :- , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiograp Hy Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Usfda/Pmda Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Ce Approved , · Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Dcgi Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Usfda/Pmda Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Ce Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Dcgi Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Usfda/Pmda Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Ce Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Dcgi Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System • Usfda /Pmda Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System • Ce-Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System Dcgi -Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle • Usfda /Pmda Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle • Ce- Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle Dcgi -Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Usfda /Pmda Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Ce-Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Dcgi - Approved • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Usfda/Pmda Approved , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Ce -Approved , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Dcgi - Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Usfda /Pmda Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Ce- Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Dcgi - Approved , Abdominal Aortic Aneurysm- Covered Stent • Usfda /Pmda Approved , Abdominal Aortic Aneurysm- Covered Stent • Ce - Approved , Abdominal Aortic Aneurysm- Covered Stent • Dcgi - Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Usfda /Pmda Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Ce - Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Dcgi - Approved , Covered Stent Grafts- Various Lengths And Diameter • Usfda /Pmda Approved , Covered Stent Grafts- Various Lengths And Diameter • Ce - Approved , Covered Stent Grafts- Various Lengths And Diameter • Dcgi - Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Usfda /Pmda Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Ce - Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Dcgi - Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Usfda /Pmda Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Ce Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Dcgi - Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal Usfda/Pmda Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal • Ce - Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal • Dcgi - Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Usfda/Pmda Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Ce- Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Dcgi - Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Usfda/Pmda Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Ce -Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Dcgi - Approved , • Ivc Filter • Various Sizes • With All Accessories • Usfda/Pmda Approved , • Ivc Filter • Various Sizes • With All Accessories • Ce -Approved , • Ivc Filter • Various Sizes • With All Accessories • Dcgi - Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Usfda/Pmda Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Ce -Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Dcgi - Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Usfda/Pmda Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Ce -Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Dcgi- Approved , • Inj. Tirzepatide • Usfda/Pmda Approved , • Inj. Tirzepatide • Ce -Approved , • Inj. Tirzepatide • Dcgi- Approved , • Inj. Cangrelor • Usfda/Pmda Approved , • Inj. Cangrelor • Ce -Approved , • Inj. Cangrelor • Dcgi- Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Usfda/Pmda Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Ce -Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Dcgi- Approved , Coronary Covered Stent

BOQ

Name of Work:- RATE CONTRACT OF CARDIAC ITEMS
Sl. No. Item Description
1RATE CONTRACT OF CARDIAC ITEMS :-
2• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy.• Inner diameter of 4 Fr.= 1.03 mm, 5Fr. = 1.20 mm, 6 Fr.=1.30 mm or more with flow rates of 12, 21,25 ml per second respectively. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiograp hy catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) Amplatz left & right, (AL1 & 2, AR 1 & 2) multipurpose, hockey stick, IMA, pigtail- 4Fr.-5Fr.-6Fr.• USFDA/PMDA approved
3• Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy. • Inner diameter of 4 Fr.= 1.03 mm, 5Fr. = 1.20 mm, 6 Fr.=1.30 mm or more with flow rates of 12, 21,25 ml per second respectively. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) Amplatz left & right, (AL1 & 2, AR 1 & 2) multipurpose, hockey stick, IMA, pigtail- 4Fr.-5Fr.-6Fr. • CE approved
4· Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy • Inner diameter of 4 Fr.= 1.03 mm, 5Fr. = 1.20 mm, 6 Fr.=1.30 mm or more with flow rates of 12, 21,25 ml per second respectively. • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) Amplatz left & right, (AL1 & 2, AR 1 & 2) multipurpose, hockey stick, IMA, pigtail- 4Fr.-5Fr.-6Fr. • DCGI approved
5PTFE Angiography Wire • Guide wire with V stick, with choice of stainless steel core or nitinol core • Must have 250 cm to 300 cm of length and .018” to .038” diameter • With silicon coated tip and bevel indicator • USFDA/PMDA approved
6PTFE Angiography Wire • Guide wire with V stick, with choice of stainless steel core or nitinol core • Must have 250 cm to 300 cm of length and .018” to .038” diameter • With silicon coated tip and bevel indicator • CE approved
7PTFE Angiography Wire • Guide wire with V stick, with choice of stainless steel core or nitinol core • Must have 250 cm to 300 cm of length and .018” to .038” diameter • With silicon coated tip and bevel indicator • DCGI approved
8Two port manifold set with pressure line 200 cm, luer lock 10cc syringe and IV set.• USFDA/PMDA approved
9Two port manifold set with pressure line 200 cm, luer lock 10cc syringe and IV set.• CE approved
10Two port manifold set with pressure line 200 cm, luer lock 10cc syringe and IV set.• DCGI approved
11Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters )With delivery system • USFDA /PMDA approved
12Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters )With delivery system • CE-approved
13Coil pusher wire for 0.014/0.018” coils, (compatible with the quoted micro catheters ) With delivery systemDCGI -approved
14Pediatric FemoralSheath 4 Fr. • Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock • Optimized catheter manoeuvrability with minimal leakage • Cannula made of two (thinner) layers of polyethylene • Color codes for easy french size identification • 0.21’’ Guide wire compatible • Diameter: 4 Fr • Lengths: 11 cm • with 21G needle • USFDA /PMDA approved
15Pediatric FemoralSheath 4 Fr.• Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock• Optimized catheter manoeuvrability with minimal leakage• Cannula made of two (thinner) layers of polyethylene• Color codes for easy french size identification• 0.21’’ Guide wire compatible• Diameter: 4 Fr• Lengths: 11 cm • with 21G needle• CE- approved
16Pediatric FemoralSheath 4 Fr.• Removable cap which has hexacuspid valve • Excellent kink resistant • Sideport extension with 3-way stopcock• Optimized catheter manoeuvrability with minimal leakage• Cannula made of two (thinner) layers of polyethylene• Color codes for easy french size identification• 0.21’’ Guide wire compatible• Diameter: 4 Fr• Lengths: 11 cm • with 21G needleDCGI -approved
17Catheters for paediatric intervention • Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy.• Inner diameter of 4 Fr.= 1.03 mm, • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) multipurpose, IMA, pigtail- 4Fr.• USFDA /PMDA approved
18Catheters for paediatric intervention • Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy.• Inner diameter of 4 Fr.= 1.03 mm, • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) multipurpose, IMA, pigtail- 4Fr.• CE-approved
19Catheters for paediatric intervention • Angiographic Catheter comprised of a two-layer construction featuring double braided stainless-steel two-ply mesh sandwiched between layers of polyurethane and polyamide elastomers allowing 1:1 torque transmission. • Transfemoral Angiography catheter – Judkin Left and Right, (JL3-JL5,JR3-JR5) multipurpose, IMA, pigtail- 4Fr.• DCGI - approved• The shaft inner layer and outer layer contain barium sulfate for visibility and contrast under fluoroscopy.• Inner diameter of 4 Fr.= 1.03 mm, • Diagnostic catheter comes with anti-kinking protector, with non-braided tip shaft (distal -2 cm) offering soft & round tip with co-axial alignment.
20INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titanium nitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (2-4 mm)• USFDA/PMDA approved
21INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titanium nitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (2-4 mm)• CE -approved
22INTRAVASCULAR RETRIEVER-Micro SNARE(‘AMPLATZ GOOSENESK’ TYPE)-Snare kit should include with all accessories like sheath etc.• A snare and its compatible sheath• Should have nitinol shaft • Titanium nitride coated tungsten loop • Should have 90 degree preformed snare loop• Radiopaque marker at distal tip • Variable size of loop (2-4 mm)• DCGI - approved
23Micropuncture set needle set 5F 7Cm needle• USFDA /PMDA approved
24Micropuncture set needle set 5F 7Cm needle• CE- approved
25Micropuncture set needle set 5F 7Cm needle• DCGI - approved
26Abdominal aortic aneurysm- covered stent • USFDA /PMDA approved
27Abdominal aortic aneurysm- covered stent• CE - approved
28Abdominal aortic aneurysm- covered stent • DCGI - approved
29Abdominal aortic aneurysm- non covered stent • USFDA /PMDA approved
30Abdominal aortic aneurysm- non covered stent• CE - approved
31Abdominal aortic aneurysm- non covered stent• DCGI - approved
32Covered stent grafts- various lengths and diameter • USFDA /PMDA approved
33Covered stent grafts- various lengths and diameter• CE - approved
34Covered stent grafts- various lengths and diameter• DCGI - approved
35Non Covered stent grafts- various lengths and diameter• USFDA /PMDA approved
36Non Covered stent grafts- various lengths and diameter• CE - approved
37Non Covered stent grafts- various lengths and diameter• DCGI - approved
38Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• USFDA /PMDA approved
39Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• CE approved
40Peripheral self expanding drug eluting stent-• Paclitaxel eluting self-expanding stent with a polymer that releases paclitaxel over 12 month with lowest dose density of 0.167ug/mm2 for SFA and PPA• Triaxial delivery system• Hybrid cell architecture with open and close celldesisn• Easy deployment with thumbwheel & pull grip• 6F sheath compatibility• Dia-6 &10 mm• Length – 40,60,80,100,120 mm• DCGI - approved
41• IVL. Catheter and Connector cable • Intravascular lithotripsy intuitive catheter with Rx system for treating highly Calcified lesions• Integrated 12mm SC balloon • NP- 6 ATM • RBP – 10ATM• Diameter – 2.5,3.0,3.5,4.0mm• 2 Emitters( 80 Pulses per Catheter )• Registry with minimum 300 patients published in a peer reviewed journal USFDA/PMDA approved
42• IVL. Catheter and Connector cable • Intravascular lithotripsy intuitive catheter with Rx system for treating highly Calcified lesions• Integrated 12mm SC balloon • NP- 6 ATM • RBP – 10ATM• Diameter – 2.5,3.0,3.5,4.0mm• 2 Emitters( 80 Pulses per Catheter )• Registry with minimum 300 patients published in a peer reviewed journal• CE – approved
43• IVL. Catheter and Connector cable • Intravascular lithotripsy intuitive catheter with Rx system for treating highly Calcified lesions• Integrated 12mm SC balloon • NP- 6 ATM • RBP – 10ATM• Diameter – 2.5,3.0,3.5,4.0mm• 2 Emitters( 80 Pulses per Catheter )• Registry with minimum 300 patients published in a peer reviewed journal• DCGI - approved
44• Mitral Clip • Trans catheter edge to edge repair (TEER) System• Cobalt chromium covered with polyester fabric and national graspers • Clip arm- 3-7 mm• Clip arm length – 9 and 12 mm • With guide catheter and delivery system and all accessories • USFDA/PMDA approved
45• Mitral Clip • Trans catheter edge to edge repair (TEER) System• Cobalt chromium covered with polyester fabric and national graspers • Clip arm- 3-7 mm• Clip arm length – 9 and 12 mm • With guide catheter and delivery system and all accessories • CE- approved
46• Mitral Clip • Trans catheter edge to edge repair (TEER) System• Cobalt chromium covered with polyester fabric and national graspers • Clip arm- 3-7 mm• Clip arm length – 9 and 12 mm • With guide catheter and delivery system and all accessories • DCGI - approved
47• Tricuspid valve- THV• Balloon expandable THV system• Hybrid honey comb cell design• Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 mm • 14 Fr Python sheath • Navigator THV delivery system • Mammoth predication balloon • Crimping tool • USFDA/PMDA approved
48• Tricuspid valve- THV• Balloon expandable THV system• Hybrid honey comb cell design• Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 mm • 14 Fr Python sheath • Navigator THV delivery system • Mammoth predication balloon • Crimping tool • CE -approved
49• Tricuspid valve- THV• Balloon expandable THV system• Hybrid honey comb cell design• Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 mm • 14 Fr Python sheath • Navigator THV delivery system • Mammoth predication balloon • Crimping tool • DCGI - approved
50• IVC filter • Various sizes • With all accessories • USFDA/PMDA approved
51• IVC filter • Various sizes • With all accessories • CE -approved
52• IVC filter • Various sizes • With all accessories • DCGI - approved
53• Peripheral drug coated balloon • 0.035” Compatible • Diameter 4 to 6 mm • Length 60-150mm• USFDA/PMDA approved
54• Peripheral drug coated balloon • 0.035” Compatible • Diameter 4 to 6 mm • Length 60-150mm• CE -approved
55• Peripheral drug coated balloon • 0.035” Compatible • Diameter 4 to 6 mm • Length 60-150mm• DCGI - approved
56• Inj. Iodixanol 100 ml• Iso- osmolar, Non ionic, dimeric, iodine containing contrast agent• USFDA/PMDA approved
57• Inj. Iodixanol 100 ml• Iso- osmolar, Non ionic, dimeric, iodine containing contrast agent• CE -approved
58• Inj. Iodixanol 100 ml• Iso- osmolar, Non ionic, dimeric, iodine containing contrast agent• DCGI- approved
59• Inj. Tirzepatide• USFDA/PMDA approved
60• Inj. Tirzepatide • CE -approved
61• Inj. Tirzepatide • DCGI- approved
62• Inj. Cangrelor• USFDA/PMDA approved
63• Inj. Cangrelor• CE -approved
64• Inj. Cangrelor• DCGI- approved
65• Inj. Tirofiban 5 mg/ 100ml.• USFDA/PMDA approved
66• Inj. Tirofiban 5 mg/ 100ml.• CE -approved
67• Inj. Tirofiban 5 mg/ 100ml.• DCGI- approved
68Coronary covered stent Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57724445
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 2 Crore
LAST DATE 21-10-2026
Authority
Authority Name Rabindranath Tagore Medical College
Work Description Tender for Rate Contract Of Cardiac Items , Rate Contract Of Cardiac Items :- , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiograp Hy Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Usfda/Pmda Approved , • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Ce Approved , · Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy • Inner Diameter Of 4 Fr.= 1.03 Mm, 5Fr. = 1.20 Mm, 6 Fr.=1.30 Mm Or More With Flow Rates Of 12, 21,25 Ml Per Second Respectively. • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Amplatz Left & Right, (Al1 & 2, annual repair 1 & 2) Multipurpose, Hockey Stick, Ima, Pigtail- 4Fr.-5Fr.-6Fr. • Dcgi Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Usfda/Pmda Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Ce Approved , Ptfe Angiography Wire • Guide Wire With V Stick, With Choice Of Stainless Steel Core Or Nitinol Core • Must Have 250 Cm To 300 Cm Of Length And .018 To .038 Diameter • With Silicon Coated Tip And Bevel Indicator • Dcgi Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Usfda/Pmda Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Ce Approved , Two Port Manifold Set With Pressure Line 200 Cm, Luer Lock 10Cc Syringe And Iv Set. • Dcgi Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System • Usfda /Pmda Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System • Ce-Approved , Coil Pusher Wire For 0.014/0.018 Coils, (Compatible With The Quoted Micro Catheters ) With Delivery System Dcgi -Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle • Usfda /Pmda Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle • Ce- Approved , Pediatric Femoral Sheath 4 Fr. • Removable Cap Which Has Hexacuspid Valve • Excellent Kink Resistant • Sideport Extension With 3-Way Stopcock • Optimized Catheter Manoeuvrability With Minimal Leakage • Cannula Made Of Two (Thinner) Layers Of Polyethylene • Color Codes For Easy French Size Identification • 0.21 Guide Wire Compatible • Diameter: 4 Fr • Lengths: 11 Cm • With 21G Needle Dcgi -Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Usfda /Pmda Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Ce-Approved , Catheters For Paediatric Intervention • Angiographic Catheter Comprised Of A Two-Layer Construction Featuring Double Braided Stainless-Steel Two-Ply Mesh Sandwiched Between Layers Of Polyurethane And Polyamide Elastomers Allowing 1:1 Torque Transmission. • Transfemoral Angiography Catheter - Judkin Left And Right, (Jl3-Jl5,Jr3-Jr5) Multipurpose, Ima, Pigtail- 4Fr. • Dcgi - Approved • The Shaft Inner Layer And Outer Layer Contain Barium Sulfate For Visibility And Contrast Under Fluoroscopy. • Inner Diameter Of 4 Fr.= 1.03 Mm, • Diagnostic Catheter Comes With Anti-Kinking Protector, With Non-Braided Tip Shaft (Distal -2 Cm) Offering Soft & Round Tip With Co-Axial Alignment. , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Usfda/Pmda Approved , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Ce -Approved , Intravascular Retriever-Micro Snare (‘Amplatz Goosenesk Type)- Snare Kit Should Include With All Accessories Like Sheath Etc. • A Snare And Its Compatible Sheath • Should Have Nitinol Shaft • Titanium Nitride Coated Tungsten Loop • Should Have 90 Degree Preformed Snare Loop • Radiopaque Marker At Distal Tip • Variable Size Of Loop (2-4 Mm) • Dcgi - Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Usfda /Pmda Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Ce- Approved , Micropuncture Set Needle Set 5F 7Cm Needle • Dcgi - Approved , Abdominal Aortic Aneurysm- Covered Stent • Usfda /Pmda Approved , Abdominal Aortic Aneurysm- Covered Stent • Ce - Approved , Abdominal Aortic Aneurysm- Covered Stent • Dcgi - Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Usfda /Pmda Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Ce - Approved , Abdominal Aortic Aneurysm- Non Covered Stent • Dcgi - Approved , Covered Stent Grafts- Various Lengths And Diameter • Usfda /Pmda Approved , Covered Stent Grafts- Various Lengths And Diameter • Ce - Approved , Covered Stent Grafts- Various Lengths And Diameter • Dcgi - Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Usfda /Pmda Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Ce - Approved , Non Covered Stent Grafts- Various Lengths And Diameter • Dcgi - Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Usfda /Pmda Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Ce Approved , Peripheral Self Expanding Drug Eluting Stent- • Paclitaxel Eluting Self-Expanding Stent With A Polymer That Releases Paclitaxel Over 12 Month With Lowest Dose Density Of 0.167Ug/Mm2 For Sfa And Ppa • Triaxial Delivery System • Hybrid Cell Architecture With Open And Close Celldesisn • Easy Deployment With Thumbwheel & Pull Grip • 6F Sheath Compatibility • Dia-6 &10 Mm • Length - 40,60,80,100,120 Mm • Dcgi - Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal Usfda/Pmda Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal • Ce - Approved , • Ivl. Catheter And Connector Cable • Intravascular Lithotripsy Intuitive Catheter With Rx System For Treating Highly Calcified Lesions • Integrated 12Mm Sc Balloon • Np- 6 Atm • Rbp - 10Atm • Diameter - 2.5,3.0,3.5,4.0Mm • 2 Emitters( 80 Pulses Per Catheter ) • Registry With Minimum 300 Patients Published In A Peer Reviewed Journal • Dcgi - Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Usfda/Pmda Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Ce- Approved , • Mitral Clip • Trans Catheter Edge To Edge Repair (Teer) System • Cobalt Chromium Covered With Polyester Fabric And National Graspers • Clip Arm- 3-7 Mm • Clip Arm Length - 9 And 12 Mm • With Guide Catheter And Delivery System And All Accessories • Dcgi - Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Usfda/Pmda Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Ce -Approved , • Tricuspid Valve- Thv • Balloon Expandable Thv System • Hybrid Honey Comb Cell Design • Size 20,21.5,23.0,24.5,26.0,27.5,29.0,30.5,32.0 Mm • 14 Fr Python Sheath • Navigator Thv Delivery System • Mammoth Predication Balloon • Crimping Tool • Dcgi - Approved , • Ivc Filter • Various Sizes • With All Accessories • Usfda/Pmda Approved , • Ivc Filter • Various Sizes • With All Accessories • Ce -Approved , • Ivc Filter • Various Sizes • With All Accessories • Dcgi - Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Usfda/Pmda Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Ce -Approved , • Peripheral Drug Coated Balloon • 0.035 Compatible • Diameter 4 To 6 Mm • Length 60-150Mm • Dcgi - Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Usfda/Pmda Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Ce -Approved , • Inj. Iodixanol 100 Ml • Iso- Osmolar, Non Ionic, Dimeric, Iodine Containing Contrast Agent • Dcgi- Approved , • Inj. Tirzepatide • Usfda/Pmda Approved , • Inj. Tirzepatide • Ce -Approved , • Inj. Tirzepatide • Dcgi- Approved , • Inj. Cangrelor • Usfda/Pmda Approved , • Inj. Cangrelor • Ce -Approved , • Inj. Cangrelor • Dcgi- Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Usfda/Pmda Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Ce -Approved , • Inj. Tirofiban 5 Mg/ 100Ml. • Dcgi- Approved , Coronary Covered Stent
Basic Detail
Tender No 65/25.09.2026
Bidding Type Tender
Location
City Udaipur
State Rajasthan
Key Dates
Publish Date 26 Sep 2026
Submission Date 21 Oct 2026
Open Date 21 Oct 2026
Finance
Tender Value 2 Crore
Tender Fee 500
EMD 4 Lakhs
Exemption Available
Document List
46b79d00-41ec-4007-9b49-f84306a0cd84.html
BOQ_1064832.xls
cardio_sep_DOC.pdf
Tendernotice_1 (79).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days
Oct 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
html

46b79d00-41ec-4007-9b49-f84306a0cd84.html

xls

BOQ_1064832.xls

pdf

cardio_sep_DOC.pdf

pdf

Tendernotice_1 (79).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders