Defence Government Departments Closing in 12 days TDR #57724433

Tender For Improvement Of Existing Panel/ Switchgear At Bop Kulidor, Bop Kutterbasa & Bop Ranibari Of 97 Bn Bsf Under Shq Bsf Panisagar.

Issued by Government Departments · tripura, Tripura
Tender Value
Ref. Documents
Estimated cost
Bid Submission
08 Oct 2026
12 days left
EMD
11914
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Improvement Of Existing Panel/ Switchgear At Bop Kulidor, Bop Kutterbasa & Bop Ranibari Of 97 Bn Bsf Under Shq Bsf Panisagar.

BOQ

Name of Work:- Improvement of existing panel/ switchgear at BOP Kulidor, BOP Kutterbasa & BOP Ranibari of 97 Bn BSF under SHQ BSF Panisagar.
Sl. No. Item Description
1Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
2Providing and laying earth connection from earth electrode with 6 SWG dia G.I. wire in 15 mm dia G.I pipe from earth electrode including connection with G.I thimble excavation and re-filling as required.
3Supplying & laying of one number PVC insulated and PVC sheathed Armoured / XLPE power cable of 1.1 KV grade of size 3.5 x 70 sqmm, direct in ground in the trench in one tier horizontal formation including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering Conf. to IS:7098 part - I (make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T)
4Supplying & laying of one number PVC insulated and PVC sheathed Armoured / XLPE power cable of 1.1 KV grade of size 3.5 x 25 sqmm, direct in ground in the trench in one tier horizontal formation including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering Conf. to IS:7098 part - I (make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T)
5Supplying & laying of one number XLPE insulated and PVC sheathed Armoured power cable of 1.1 KV grade of size 3.5 x 70 sq mm in the existing RCC/ HUME/ METAL pipe/surface as required Conf. to IS:7098 part - I of ( make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T)
6Supplying & laying of one number XLPE insulated and PVC sheathed Armoured power cable of 1.1 KV grade of size 3.5 x 25 sq mm in the existing RCC/ HUME/ METAL pipe/surface as required Conf. to IS:7098 part - I of ( make KEI/ Polycab/Havells/ Finolex/ Plaza/L&T)
7Supplying & laying of G.I. pipe of 40 mm dia (medium duty ) G.I pipe in floor/wall/road for protection of UG cable including cutting the wall/floor/metalled road and making good the same as required. Make Jindal/ TATA/ Bansal/ Hindustan/equivalent.
8SITC of outdoor type feeder piller, double door made out of 16 SWG CRCA sheet of size not less then 1200 mm x 1000 mm x 350 mm deep having 200 amps, 04 nos insulated aluminium bus bars, suitable size of angle iron frame with 04 nos 600 mm long legs and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required. (i) 100 Amps, 4 pole, 415 volts, 25 kA, 50 Hz MCCB make L&T/Havells/C&S/HPL/equivalent - 2 Nos (ii) 100 Amps, 4 pole, 415 volts, 50 Hz changeover make L&T/Havells/C&S/HPL/equivalent -01 Nos (iii) 63 Amp, 4 pole, MCCB, 10 kA, 415 V, 50 Hz make L&T/Havells/C&S/HPL/equivalent - 02 Nos(iv) 63 Amp, Double pole, MCB, 10 KA, C curve, 415 V, 50 Hz make L&T/Havells/C&S/HPL/equivalent - 06 Nos(v) Cu wire lead a) 16 sq mm. (vi) Thimble suitable size (vii) Phase indicator LED Lamp (R,Y,B) -03 Nos
9SITC of outdoor type feeder piller, double door made out of 16 SWG CRCA sheet of size not less then 1000 mm x 900 mm x 350 mm deep, having 200 amps, 04 nos insulated aluminium bus bars, suitable size of angle iron frame with 04 nos 400 mm long legs and to accommodate following accessories, front & back door openable and P & F of internal connection with suitable size of cu wires, arrangement for incoming / outgoing cabling / cable termination, earthing, locking, interconnection etc. as required. (i) 100 Amps, 4 pole, 415 volts, 50 Hz MCCB make L&T/Havells/C&S/HPL/equivalent -01 Nos (ii) 63 Amp, 4 pole, MCCB, 415 V, 50 Hz make L&T/Havells/C&S/HPL/equivalent - 02 Nos (iii) 63 Amp, Double pole, MCB, c curve, 415 V, 50 Hz make L&T/Havells/C&S/HPL/equivalent - 06 Nos(iv) Cu wire lead a) 16 sq mm. (v) Thimble suitable size (vi) Phase indicator LED Lamp (R,Y,B) -03 Nos Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57724433
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 08-10-2026
Authority
Authority Name Border Security Force
Work Description Tender for Improvement Of Existing Panel/ Switchgear At Bop Kulidor, Bop Kutterbasa & Bop Ranibari Of 97 Bn Bsf Under Shq Bsf Panisagar.
Basic Detail
Tender No 94/SHQ(/PSR/AE(E)/NIT/2026-27
Bidding Type Tender
Location
City tripura
State Tripura
Key Dates
Publish Date 26 Sep 2026
Submission Date 08 Oct 2026
Open Date 09 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 11914
Exemption Not Available
Document List
94bopranibariandkulidore97bn.pdf
a1f52333-aecc-4c3d-ba45-10f8bf70544b.html
BOQ_975032.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 26, 2026
11:30 IST

Tender Published

Tender notice published.

Today
Oct 08, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Oct 09, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
pdf

94bopranibariandkulidore97bn.pdf

html

a1f52333-aecc-4c3d-ba45-10f8bf70544b.html

xls

BOQ_975032.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders