Tender for Carrying out the Work Reapiring and Overhauling of 11 kv Different Make vcb Complete/control Panel in all Electrical/mechanical Works at Installed Various 33/11 kv Substation Under Eudd-technical, 33 kv Line & Sub-station-expressway, Noida in t
Tender Overview
Project Description
Tender for Carrying out the Work Reapiring and Overhauling of 11 kv Different Make vcb Complete/control Panel in all Electrical/mechanical Works at Installed Various 33/11 kv Substation Under Eudd-technical, 33 kv Line & Sub-station-expressway, Noida in the Juridiction of Eudc-technical, Noida for the Period of 06 Months.
BOQ
| Sl. No. | Item Description |
| 1 | REAPIRING AND OVERHAULING OF 11 KV DIFFERENT MAKE VCB COMPLETE IN ALL ELECTRICAL/MECHANICAL WORKS INCLUDING REPAIRING & SETTING OF DEFECTIVE SYSTEM WITH SPARE PARTS & LEVERS FOR SMOOTH & PROPER OPERATIONS AND REMOVAL OF ELECTRICAL / MECHANICAL DEFECT OF 11 KV VCB FROM SWITCHGEARS INCLUDING MAKING BURNT WIRING, CHECKING PROPER & OK TRIPPING SYSTEM FROM RELAY OF 11 KV VCB WITH PANEL AT INSTALLED VARIOUS 33/11 KV SUB-STATIONS AT INSTALLED VARIOUS 33/11 KV SUBSTATION AS PER FOLLOWING :-NOTE: - THE REPAIR WORK SHALL BE INVOLVED IN CARRYING OUT THE REPAIR WORKS VCBs THE MAIN ITEMS / PARTS (DAMAGE / UNSERVICEABLE) SHALL BE PROVIDED BY THE DEPARTMENT FOR REPLACEMENT OF THE SAME & GEARS, BEARINGS, STUDS, INDICATOR LAMPS, FLEXIBLE COPPER WIRE LUGS, TIE, BAKELITE SOCKET, NUTS & BOLTS ETC. SHALL BE PROVIDED BY THE CONTRACTOR. |
| 2 | PROVIDING AND REPLACEMENT OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING. |
| 3 | PROVIDING AND REPLACEMENT OF 11KV VCB SPRING CHARGING MOTOR OF APPROPRIATE RATING/STANDARD MAKE. |
| 4 | PROVIDING AND REPLACEMENT OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING. |
| 5 | PROVIDING AND REPLACEMENT OF DEFECTIVE/BURNT AUXILLIARY SWITCH OF APPROPRIATE RATING. |
| 6 | PROVIDING AND REPLACEMENT OF DEFECTIVE ANTIPUMPING RELAY. |
| 7 | PROVIDING AND REPLACEMENT OF DEFECTIVE SPOUT R.Y.B. PHASE INCOMING & BUS BAR SIDE. |
| 8 | PROVIDING AND REPLACEMENT OF DEFECTIVE JAW (MALE / FEMALE) FOR 11 KV VCB TROLLEY. |
| 9 | PROVIDING AND REPLACEMENT OF DEFECTIVE AMPERE METER. |
| 10 | PROVIDING AND REPLACEMENT OF DEFECTIVE TNC SWITCH. |
| 11 | PROVIDING AND REPLACEMENT OF DEFECTIVE LOCAL/REMOTE SWITCH. |
| 12 | REPLACEMENT & SUPPLY OF DEFECTIVE CLOSING COIL (24 VDC). |
| 13 | IN CASE OF EMERGENCY BREAKDOWN VCB REPAIRING ETC WORK LINE CLEANING AND REFITTING AFTER REMOVAL OF FAULT WITH IN 1 HOUR AFTER GETTING INFORMATION AND WARRANTY PERIOD WILL BE SIX MONTH. |
| 14 | PROVIDING & REPLACEMENT OF DAMAGE HEATER WITH ENERGATION COMPLETE. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender