BOQ
| Sl. No. | Item Description |
| 1 | Excavation over areas not exc. 1.50 m deep and getting out in soft / loose soil complete all as specified and directed. |
| 2 | Excavation over areas exc. 1.50 m but not exc. 3.0 m deep and getting out in soft / loose soil complete all as specified and directed. |
| 3 | Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for manholes, cesspits, shafts, laying of cable etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed. |
| 5 | Removing surplus excavated soil to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed. |
| 6 | M&L for earth filling (approved earth brought from out of defence land), spreading, leveling & compecting n exc. 30 cm thick in Layers, watering, well ramming/rolling and finishing to required size, shape,etc.n exc. 1.5m high from base complete all as specified and directed.Note : Mixing of approved earth filling and excavated soil shall not be allowed. Payment shall be made of compacted earth with 90% compaction |
| 7 | M & L for hard core free from dust and vegetation of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken bricks complete all as specified and directed. |
| 8 | M & L for provding PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in copings, bed plates, plinth courses, parapets and the like including weathering, slightly rounded or chamfered angles and throating including use and waste of necessary form work etc complete all as specified and directed. |
| 9 | M & L for providing plain cement concrete, type D-2, 1:4:8 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 10 | M & L for providing precast cement concrete in door or window cills, lintel, bressumers, bed plat, apex stone, pintle blocks, bonders and similar items with plain faces including chamfers, weathering, throating etc. in cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate and setting in cement mortar 1:4 complete all as specified and directed. |
| 11 | M & L for brushing neat cement slurry with 3.0 Kg/Sqm over roof slab complete all as specified and directed. |
| 12 | M & L for providing plain cement concrete, type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges with and including necessary form work as required complete all as specified and directed. |
| 13 | M & L for cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in surface channel or drain complete all as specified and directed. |
| 14 | M & L for extra forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitered / stopped ends etc. complete all as specified and directed. |
| 15 | M & L for providing pre-cast reinforcement cement concrete landing, cover slabs, chullah hoods, chajjas, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed.Note:- Reinforcement shall be measured & paid separately. |
| 16 | M & L for RCC 1:1½ :3 type A1 using 20 mm graded crushed stone aggregate as in foundation including rafts, footing, foundation beams, plinth beams, base of columns and the like complete all as specified and directed. |
| 17 | M & L for RCC 1:1½ :3 type A1using 20 mm graded crushed stone aggregate, as in columns, pillars, piers, posts, struts and the like complete all as specified and directed. |
| 18 | M & L for RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate, as in beams, cantilevers, bressummers, lintels over 1.50 m span and the like complete all as specified and directed. |
| 19 | M & L for RCC type B-1 (1:2:4) using 20 mm graded crushed stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed. |
| 20 | M & L brick work with fly ash bricks, straight or curved on plan exc 6M mean radius, old size brick built in cement mortar 1:6 complete all as specified and as directed. |
| 21 | Ditto all as per item No 5 above but except bricks.Note : Old bricks retrived from demoltion shall be used. |
| 22 | M&L for brick work with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 23 | M & L for use and waste of form work to sides of concrete foundation, footing, bases of columns, raft & raft beams, sides and soffits (if any) of foundation and plinth beam and similar works in rough finished flat surface of concrete complete all as specified and directed. |
| 24 | M & L for use and waste of form work to sides of pillars, posts, struts, piers, columns and stanchions in rough finished surface of concrete complete all as specified and directed. |
| 25 | M & L for use & waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc. also splayes between floors and beams in rough finished surface of concrete complete all as specified and directed. |
| 26 | M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed. |
| 27 | Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 28 | Taking down cement or cement lime plaster including tiles if exists, from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. including removing of rubbish off the premises complete all as specified and directed |
| 29 | S & F of solid PVC door frame of size 50mm x 47mm made out of 5 mm thick prelam PVC sheet and edges will be painted to match with prelam sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed. |
| 30 | S & F of 28 to 30 mm thick (style thickness) factory made solid PVC moulded with particle board core, door shutter with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face and 2mm plain colour PVC sheet on back face as per specification and drawing given on MES schedule Part-II (2010) complete all as specified and directed. |
| 31 | S & F 100mm butt hinges stainless steel, ISI marked and fixed complete all as specified and directed. |
| 32 | S & F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 33 | S & F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 34 | M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 35 | M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 36 | M & L for mild steel TMT bars 6 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 37 | S & F steel window / ventilator glazed and gauged (combination) with side hung / top hung shutters including box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame including guard bars and necessary closer arrangement in window complete all as specified and directed. |
| 38 | M & L for providing false ceiling with 4 mm thick E-board white prelaminated set embossed reinforced designer ceiling board of approved texure fixed with GI imposed grid frame work of size not more than 600 x 600 mm having 24 mm wide T- section, runner made of 0.33 mm GI sheet and angle made of 0.45 mm GI sheet, suspended with 4 mm dia GI wire complete all as specified and directed. |
| 39 | S & F aluminium anodized 50 micron powder coated door shutters, with frame of section 100x44x1.60 to1.8 mm thick, aluminium sections for shutter anodised aluminum powder coated shutter, Glazing shall be of 4.8 mm thick tinted sheet glass, fixed with rubber gasket and aluminum glazing clips, section of aluminum shutter of following sizes:- (i) Styles 85 x 44.45 x 3 mm thick section No- 4526(ii) Top rail 95.25 x 44.45 x 1.7 mm thick section No-4553 (iii) Middle/lock rail 83.50 x 44.45 x 1.7 mm thick section No-4565(iv) Bottom rail 114.3 x 44.45 x 2.82 mm thick section No-4529(v) Glazing clip 0.70 mm thick section N0-4407 all as directed (vi) Handle: Aluminum handle 100mm girth and as per sample(vii) Tower bolt: 9.90 mm dia sheet and section Ano-4002 7, 200 mm long(viii) Mortic lock: 100 mm size 4 lever. Note : Cost of 4.8mm thick tinted sheet glass and above mentioned all builder hardware fittings shall be deemed inclusive in quoted unit rate. |
| 40 | S & F of alumium anodized powder coated glazed window shutter sliding type using 1.80 mm thick aluminium open three track section having size of style & top rails 83x44mm, bottom rails 100x44mm including necessary joining cleats, glazing clips, rubber packing, anodized aluminium snap beading screws, anodised aluminium fittings and including glazing by using 5mm thick plain sheet glass and stainless steel wire mess of dia 0.36mm and aperture 1.4mm, complete all as specified and as directed. Note : Cost of sheet glass, stainless steel wiremess and other required fittings and fixture shall be deemed inclusive in quoted unit rate. |
| 41 | S & F of aluminium anodised grill (anodised transparent or dyed to required shade according to IS:1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws , including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and as directed. |
| 42 | S & F of aluminium anodized powder coated sections (minimum thickness of powder coating 50 micron) for partitions (Fixed portions) with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides partition and glazing shall be of 4.8mm thick sheet glass or board as required including EPDM rubber / neoprene gasket complete all as specified and as directed. Note : Cost of sheet glass / board and other required accessories shall be deemed inclusive in quoted unit rate. |
| 43 | M & L for roof/sunken treatment with polymeric water proofing mem breane with certain specification given below as under complete all as specified & directed(a) M&L plastering 10mm in CM 1:4 using 100% course sand on roof including WPC @ 3% by weight of cement.(b) Applying a coat of bitumenous primer @ 0.50 LTRs /Sqm and allow to dry(c) Applying a coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm. (d) Supply and laying APP based polymeric water proofing membrane, weight not less than 3.00 kg/sqm and and minimum 3 mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) sealed the side laps with spread temper (e) applying a tack coat of hot blown bitumen grade 85/25 @ 1.20 Kg/Sqm |
| 44 | M & L for roughening the surface of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 45 | M & L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in sub floor of floor finishes, finished even and rough complete all as specified and directed. |
| 46 | M & L for 50mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in sub floor of floor finishes and finishing top surface even and smooth with using extra cement complete all as specified and directed. |
| 47 | M & L for providing 75mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade crushed stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed. |
| 48 | M & L for providing 100mm thick cement concrete 1:4:8 type D-2 (using 40 mm grade crushed stone aggregate) as in sub floor, sub base of floor finished even and rough complete all as specified and directed. |
| 49 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removing the rubbish off the premises complete all as specified and directed. |
| 50 | M & L for Non-skid ceramic coloured tiles jointless premium quality 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. |
| 51 | M & L for Glazed ceramic tiles (coloured) premium quality jointless in vertical surfaces 600x300x7-8mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 52 | M & L for 18 to 20mm thick granite (of any type or any shade) work (table rubbed and polished ) in steps, jambs, pillars, window -cills, cooking platforms and like pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including rounding of edge laid over and including 15mm thick screed bed in CM (1:6) including rounding of edges of stone slabs one edge smooth round with polishing to match the finish of granite at top such as in steps, cooking platform, and other similar situations complete all as specified and directed. |
| 53 | M & L for rendering 15mm thick on fair faces of brick work in CM1:4, finished even and fair complete all as specified and directed |
| 54 | M & L for 15mm thick rendering in cement mortar (1:4) mixed with water proofing compound @3% by weight of cement on fair faces of brick work or concrete surfaces, finished even and fair complete all as specified and directed.Note : WPC shall be measured and paid separately. |
| 55 | M & L for rendering 15mm thick on other than fair faces of brick work in CM1:6, finished even fair complete all as specified and directed |
| 56 | Supply only integral waterproofing compound complete all as specified and directed. |
| 57 | M & L for rendering 10mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished even and fair complete all as specified and directed. |
| 58 | M & L 5mm thick rendering in cement mortar in CM (1:4) on ceiling finished even and fair complete all as specified and directed. |
| 59 | M & L for preparation of newly plastered wall surfces and applying three coats of white wash complete all as specified and directed. |
| 60 | M & L for preparation of newly plastered surfaces of walls and finishing premium weather proof acrylic smooth exterior paint with Silicone additives of required shade in two coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm over and including a coat of 1mm thcik wall care putty complete all as specified & as directed. |
| 61 | M & L for preparation newly plastered ceiling surfaces and applying three coat of white wash complete all as specified and directed. |
| 62 | M & L for preparation of newly plastered surfaces and applying two coats of oil emulsion distemper (OBD) over and including 2-3mm wall care putty & primer on wall of approved shade/tint complete all as specified & as directed. |
| 63 | M & L for preparation of newly plastered surfaces of wall of any description and applying Two coats of Plastic emulssion paint over and including a coat of primer complete all as specified and directed. |
| 64 | M & L for complete removal of existing treatment of surfaces of walls and preparation of old surfaces and applying two coats of oil emulsion distemper of approved shade / tint complete all as specified and directed. |
| 65 | Material & Labour for preparation of newly plastered surfaces of finished walls applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. Note- Primer and emulsion to be carried out through air less spray machine (Mechanical means |
| 66 | M & L for preparation of old treated surface of wall / ceiling and applying two coats of oil bound distemper with roller complete all as specified and directed. |
| 67 | Complete removal of existing treatment on wall / roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean, free from dust, loose paint etc complete all as specified and directed. |
| 68 | M & L for applying 2-3mm thick wall care putty over prepared surface to achive the surface even and smooth for painting complete all as specified and directed. |
| 69 | S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of apertature 1.40mm and fixed with tinned tacks or stainless steel wire staples all complete all as specified and directed. |
| 70 | S & F 3mm thick figured glass, pin head type and glazing with oil putty in square n. exc 0.50 Sqm in each pane complete all as specified and directed. |
| 71 | M & L for preparation of new or previously untreated wood and wood based surfaces of any description not otherwise descriped over 10cm width girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 72 | M & L for preparation of new steel and iron surfaces of any description over 10CM width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 73 | S & F 15mm GI water tubing(concealed type), medium grade, galvanised with all fittings fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 74 | S & F 20mm GI water tubing, medium grade, galvanised with all fittings and fixed to walls, ceiling or laid in floors/ trenches complete all as specified and directed. |
| 75 | S & F triple layered rotational moulded polyethylene water storage tanks of capacity 1000 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position including lid cover complete all as specified and directed. |
| 76 | S & F ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe of 20mm dia and fixed (minimum weight 210 gms) complete all as specified and directed. |
| 77 | S & F tubular towel rail, chromium plated brass 20mm dia 'D\\" type 60cm long between flanges complete all as specified and directed. |
| 78 | S & F brass chromium plated shower rose of 125mm size with swivel joints, including fixing to steel pipe or union of 15mm bore complete all as specified and directed. |
| 79 | S & F PVC valve less, syphonic action type flushing cistern, 10 Litre capacity, low level, white with inlet, ball vlave float, handle including PVC rigid pipe 32mm bore as flush pipe fixed on walls by drilling holes and using PVC rawl plug of suitable size complete all as specified and directed. |
| 80 | S & F wash hand basins vitreous china, coloured flat back size 550 x 400mm fixed including bracket complete all as specified and directed. |
| 81 | S & F CP grating doom 100 mm dia chromium plated complete all as specified and directed. |
| 82 | S & F health faucet(ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 m long flexible metal tube and ABS wall hook/holder including macking connections and fixed in position complete all as specified and directed |
| 83 | S & F CP brass jet spray with hand hold arrangement including 1.5 m long flexible pipe with hook of superior quality complete all as specified and directed |
| 84 | S & F glass corner self assembly, fancy type, made of 6 to 7mm thick toughened glass of size 250x250mm, fixed with CP brackets complete all as specified and directed. |
| 85 | S & F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 86 | Supply and fixing 15mm bore brass CP mixer valve wash basin for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 87 | S & F of 15mm bore cast copper alloy chromium plated bib tap with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and directed. |
| 88 | S & F of angle valves 15mm bore , cast copper alloy chromium plated with long sunk and cap (Concealed type), screwed down high pressure screwed both ends for iron pipe or for unions and fixed etc complete all as specified and directed. |
| 89 | S & F of PVC connection, heavy duty 15mm bore, 45cm long with 2 Nos PTMT nuts of approved quality complete all as specified and directed. |
| 90 | S & F of vitreous China \\"Orissa pattern\\" size 580 x 440mm\\" coloured, with intergral foot rests with vitreous china 'P' or 'S' trap front or back inlet including connection to trap and to flushing pipe, anti syphnage pipe and making good the floor to match the existing complete all as specified and directed. |
| 91 | S & F of 110mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including PVC clamps complete all as specified and directed. |
| 92 | S & F of 75mm PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall or laid in floors / trenches with & including PVC clamps complete all as specified and directed. |
| 93 | S & F of 110mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed. |
| 94 | S & F of 75mm PVC (SWR) junction single, (Single T) equal or unequal with access door with cement joint complete all as specified and directed. |
| 95 | S & F of 110mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 96 | S & F of 75mm bore PVC (SWR) bend / shoe of any radius with access door, complete all as specified and directed. |
| 97 | S & F of PVC (SWR) floor trap 75mm, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 98 | S & F of PVC (SWR) reducers 75/110mm bore complete all as specified and directed. |
| 99 | S & F of vitreous China urinals, half stall type (flat back), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including spreader, 60mm long brass screws, pointing around urinal back in cement; fixing with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed. |
| 100 | S & F of 32 mm bore Low density PVC flexible pipe for Wash hand basin/sink etc complete all as specified and directed. |
| 101 | Demolition and breaking up drain pipes of 150 mm bore (salt glazed stoneware, AC or reinforced concrete) set in cement mortar complete all as specified and directed. |
| 102 | Supply and laying of underground PP/PE Double Wall Corrugated (DWC) anti-rodent pipes of 150mm bore, stiffness class SN-8, conforming to IS: 16098-2013, having smooth inner surface and corrugated outer surface, including all fittings and accessories, jointing with rubber ring joints as per manufacturer’s specifications, laid to required slope and alignment complete all as specified and directed.Note : Excavation & earth work shall be measured and paid seprately. |
| 103 | Supply and laying of underground PP/PE Double Wall Corrugated (DWC) anti-rodent pipes of 200mm bore, stiffness class SN-8, conforming to IS: 16098-2013, having smooth inner surface and corrugated outer surface, including all fittings and accessories, jointing with rubber ring joints as per manufacturer’s specifications, laid to required slope and alignment complete all as specified and directed.Note : Excavation & earth work shall be measured and paid seprately. |
| 104 | M & L for 150 mm bore salt glazed stoneware drain pipes grade 'A' laid in trenches and jointed in cement sand mortar 1:1 with spun yarn complete all as specified and directed. |
| 105 | M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 150 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 106 | M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 200mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed. |
| 107 | M & L for constrction of soakage wells of size 3.6 M dia X 6.0 M with effective depth including earth work in any type of soil, foundation in PCC 1:3:6, well wall shall be constrcuted in honey combed bricks work in CM (1:4) with top ring and slab of RCC M-25 concrete including necessary form work and TMT reinforcment and filling with filled with brick bats including intercepting chamber and screen chamber made of Brick masonary in CM 1:4 including, RCC cover slab, and inter connecting pipes of RCC/DWC complete all as specified and directed.Note : Cost of excavation & other earth work including connection to sewage pipe line shall be deemed inclusive in quoted unit rate. |
| 108 | M & L for construction of RCC Septic tank for 100 Users having effective depth of 1.5 meter and overall depth of 3 meter designed With UPFLOW FILTER to carry sewage and sullage water including earthwork in any type of soil, PCC 1:4:8 below foundation, RCC M-30 Design Mix in Walls, Base Slab, Baffle walls and Roof Slab including beams etc including necessary form work and TMT reinforcment with Vent shaft, manhole openings with cover connection etc complete all as specified and directed.Note : Cost of excavation & other earth work including connection to sewage pipe line shall be deemed inclusive in quoted unit rate. |
| 109 | Cutting openings, through brick walls for door, window and other openings or enlarging existing openings. converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks to store and removal of rubbish not exc 50m distance complete all as specified and directed. |
| 110 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) or of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 111 | Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed. |
| 112 | Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed. |
| 113 | M & L for cutting into existing manhole for connecting new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100/150mm dia pipe complete all as specified and directed. |
| 114 | S & F of pre cast SFRC (Steel Fibre Reinforced Concrete) of approved make, man hole cover / drain 75mm thick cover with cover frame of requisite size including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M-30 grade concrete by vibro compression process, medium duty confirming to IS-12592 including fixing on manhole complete all as specified and directed. |
| 115 | M & L for drilling 300mm dia borehole by DTH cum rotary at any depth below the ground level in any kind of soil incl hard stone/boulders incl electronic logging, MS cap, MS flt iron clamp, reducing socket etc up to 150 m depth incl disposal of surplus soil to a distance exc 5 km away complete all as directed and specified. Note- The depth of drilling bore shall be upto water table and will be directed by Engr-in-charge |
| 116 | S & F self perforated unplasticised PVC pipes 200mm dia of pressure rating 10kg/Sqcm fixed complete to wall or ceiling or in floors complete all as specified. Note-The rates quoted in above items is deemed to be inclusive of all T&P equipments and labour required for execution of this item at site including transportation charge for the said T&P equipments and no extra cost shall be paid for the same. |
| 117 | Supply, installation and testing of UPVC pipe for Air vent-200mm dia (SCH-40) with all necessary fittings including jointing and jointing materials complete all as specified and directed. |
| 118 | M & L for loose filling with broken stone aggregates of guage 40 to 80mm in pits, wells complete all as specified and directed. |
| 119 | M & L for pea Gravel/moorum/red bajri filling in floors or pavings spread and levelled in layers not exc 15 cm thick, watered and rammed to true surface complete all as specified and directed. |
| 120 | M&L for sand filling (200 mm thick in layers) under floors or in foundations including watering and consolidation complete all as apecified and directed. |
| 121 | S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed. |
| 122 | M&L for uPVC rain water gutter pipes of size 150/110mm/75mm bore pipes of 3mm thick (4 Kg/cm2) as required at site fixed with suitable clamps in roof projections / roof outlet including bends,reducer, water filter gratings, of sizes 150mm/110mm/75mm bore fixed with joint sealing adhesive composite complete on wall / along the roof projections complete all as specified and as directed by Engr-in-charge. |
| 123 | M&L for point wiring with 1100 Volts grade PVC insulated FRLS multi-stranded copper conductor cable 1.5 sqmm including PVC insulated FRLS copper earth continuity conductor 1.5 sqmm, colour-coded as per IS, drawn through and including concealed rigid non-metallic PVC conduit, medium grade, ISI marked, ivory colour of size not less than 25 mm dia with all necessary conduit fittings and accessories such as bends, tees, couplers, junction boxes etc including concealed sunken modular GI metal boxes of minimum 1.0 mm thickness with modular mounting cover plates and frames of approved colour, suitable for mounting modular switches, sockets, regulators, etc complete all as specified and directed for the following:– One light point controlled by one switch. |
| 124 | All as per item No above 123 One socket outlet 6 Amp controlled by one switch on the same board with other switches. |
| 125 | All as per item No above 123 One socket outlet 6 Amp controlled by one switch on indepdendent board. |
| 126 | M & L for point wiring with 1100 Volts grade PVC insulated FRLS multi-stranded copper conductor cable 2.5 sqmm, including PVC insulated FRLS copper earth continuity conductor 2.5 sqmm, colour-coded as per IS, drawn through and including concealed rigid non-metallic PVC conduit, medium grade, ISI marked, ivory colour, of size not less than 25 mm dia, with all necessary conduit fittings and fixing accessories, including sunken GI metal box of minimum 1.0 mm thickness with modular mounting cover plate and frame of approved colour, suitable for mounting modular accessories, complete for one 6A or 16 A socket outlet point controlled by one switch on independent board complete all as specified and directed. |
| 127 | S&F Switch Modular type 6A single pole, one way, 1 module complete all as specified and as directed |
| 128 | S&F Switch Modular type 16A single pole, one way, 1 module complete all as specified and as directed |
| 129 | S&F Modular type Socket, 6A - 2/3 pin combined 2 module complete all as specified and as directed |
| 130 | S&F Modular type Socket 6A/16A - 2/3 pin combined 2 module complete all as specified and as directed |
| 131 | S&F Modular White cover plate with frame, 12 module complete all as specified and as directed |
| 132 | S & F Modular White cover plate with frame, 8 module complete all as specified and as directed |
| 133 | S&F Modular White cover plate with frame, 3 module complete all as specified and as directed |
| 134 | S&F Modular White cover plate with frame, 2 module complete all as specified and as directed |
| 135 | Supply and fix in replacement LED tube light fittings 1200 mm,20 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed. |
| 136 | Supply and fix in replacement LED tube light fittings 600 mm, 10 W higher energy saving decorative ultra slim square profile LED lighting fixture with extruded aluminum housing enviromental friendly, energy efficient complete all as specified and directed. |
| 137 | Supply and fix ceiling rose, 6 Amp, 250 volt, AC, ISI marked with three equal size terminals and PVC / Polycarbonate insulated body of 50 x 25 mm size complete all as specified & directed. |
| 138 | M & L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable using colour coding drawing into and including concealed rigid non metallic PVC conduit 25 mm dia, medium grade, ISI marked ivory colour along with accessories of nominal sizes 2x6 sqmm + 1x6 sqmm earth wire complete all as specified and directed. Note : (i) Cost of cutting & chasing for concealltion of conduit and making good as existing to distrubed surface shall be deemed inclusive in quoted unit rate. (ii) Three runs of 6 sqmm copper conductor and 01 run of PVC conduit shall be measured as one unit. |
| 139 | M & L for submain wiring alongwith earth continuity conductor with PVC insulated FRLS multistranded copper conductor cable using colour coding drawing into and including concealed rigid non metallic PVC conduit 25 mm dia, medium grade, ISI marked ivory colour along with accessories of nominal sizes 2x4sqmm + 1x4 sqmm earth wire complete all as specified and directed. Note : (i) Cost of cutting & chasing for concealltion of conduit and making good as existing to distrubed surface shall be deemed inclusive in quoted unit rate. (ii) Three runs of 4 sqmm copper conductor and 01 run of PVC conduit shall be measured as one unit. |
| 140 | Supply and fixing of AC modular box with modular 20 Amp MCB SPN suitable for Geyser and AC complete with and including MCB, SP, AC, 240 volt of 20 Amp, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete all as specified & directed. |
| 141 | Supply and fix in replacement factory made powder coated distribution board 4 way TPN DB Double door with metal double door (IP-43 protection IK -09) fabricated of CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps bus bar, Neutral bar, Standard din rail,earth bar and cable ties for cable management, top and bottom removable gland plates with provn for MCB TPN / RCCB as incomer and 12 SP MCBs outgoing after fixing making good surface with fine plastering, finishing and colouring with existing colour matching complete all as specified & directed. |
| 142 | Supply and fix in replacement of MCB, SP, AC, 240 volt of 06 to 40 Amp capacity \\"C\\" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. |
| 143 | Supply and fix in replacement of MCB, TPN, AC, 415 volt of 63 Amp capacity \\"C\\" curve, 10 kA breaking capacity and making connections by using suitable copper lugs complete all as specified & directed. |
| 144 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level steel earth plate connected with GI wire 04 mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15 mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150 mm thick around GI earth plate, GI pipe medium grade 20 mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40 mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6 mm dia at the rate of 75 mm centre to centre both way with 12 mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40 mm x 40 mm x 3 mm frame for pit cover including testing on completion complete all as specified and directed.Note : (a) Cost of excavation & other earth work shall be deemed inclusive in quoted unit rate.(b) Earth wire upto 7.5 RM from test point shall be deemed inclusive in quoted unit rate. |
| 145 | S&F of exhaust fan single phase, 230/240 Volt heavy duty of size 300 mm sweep 1400 RPM including suitable louvers and making connection with twisted copper flexible wire 23/0.076mm all as specified and directed. |
| 146 | Supply and fixing in replacement LED Bldg security light fitting LED 35 watt with SPD, PF not less or equal 0.9,epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 incl with bracket, clamps, nuts, bolts protection complete all as specified and directed and directed. |
| 147 | Supply, laying and testing cable XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25sqmm 3.5 core complete all as specified and directed. |
| 148 | Supply and filling of river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified.Note : Punned thickness of sand shall be measured & paid only. |
| 149 | Supply and laying well burnt old size bricks, sub class \\"B\\" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender