Tender For Provision Of Borewell With Allied Services To Hq Cif (R) Under Age (I) Cif (R)
Tender Overview
Project Description
Tender for Provision Of Borewell With Allied Services To Hq Cif (R) Under Age (I) Cif (R)
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-Oct-2026 | Corrigendum No 01 | Date | 24-Oct-2026 |
| 2 | 17-Oct-2026 | Corrigendum No 02 | Date | 31-Oct-2026 |
| 3 | 22-Oct-2026 | Corrigendum No 03 | Date | 03-Nov-2026 |
| 4 | 22-Oct-2026 | Corrigendum No 04 | BOQ | 03-Nov-2026 |
| 5 | 17-Oct-2026 | Corrigendum No 02 | Date | 31-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Supply & laying and testing cable XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 11000 volts (earthed) grade cross sectional area 95 sqmm, 3 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed.Note:- Excavation, removal, return filling, protection for cable work with brick work shall be measured and paid separately. |
| 2 | Supply & laying and testing cable XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 150 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed.Note:- Excavation, removal, return filling, protection for cable work with brick work shall be measured and paid separately. |
| 3 | Supply & laying and testing cable XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 95 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed.Note:- Excavation, removal, return filling, protection for cable work with brick work shall be measured and paid separately. |
| 4 | Supply & laying and testing cable XLPE insulated, screened, PVC bedded galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 16 sqmm, 4 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed.Note:- Excavation, removal, return filling, protection for cable work with brick work shall be measured and paid separately. |
| 5 | Supply and fix HT overhead line of 11KV on 11 meter steel poles with continuous GI earth wire, including earthing of poles cross arms, insulators etc and ACSR conductor steel reinforced (ferret) all as specified and directed. |
| 6 | Material & Labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (09 meters long) and applying two coats of aluminum paint over a coat of red oxide primer,the embeded portion shall be applied with two coats bituminous paint complete all as specified and directed.Note : PCC & Earth work will be measured and paid seperately. |
| 7 | Material & Labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 meters long) and applying two coats of aluminum paint over a coat of red oxide primer,the embeded portion shall be applied with two coats bituminous paint complete all as specified and directed.Note : PCC & Earth work will be measured and paid seperately. |
| 8 | Material & labour for Switch Air Break Gang Operated for 11 KV grade, Triple pole vertically mounted having 12 insulator and fitted on steel frame suitabe for, current rating 400 Amps, mechanically operated mechanism consisting of Operating Rod of GI Pipe 25mm bore (dia) ‘light grade’ of suitable Length worked From Ground Level and with Locking Arrangement Mild Steel Flat Iron Clamp 50x6mm including Expulsion Fuse, Single Pole, Channel type/ drop out type suitable as per Site requirement with Working Pressure 11 KV grade of capacity 50 to 100 Amps, complete all as specified and as directed. |
| 9 | S&F of Lightning Arrestor expulsion type complete with all Fittings Transmission Class discharge capacity 65 KA suitable for working pressure of 11000 Volts, complete all as specified and directed. |
| 10 | Supply and fix anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole as ordered, complete all as specified and directed. |
| 11 | Material & labour for cross arms, bracing, supports, clamps and back plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one primer coat and two coats of aluminium paint, complete all as specified and as directed. |
| 12 | M & L for Construction of Platform for installatiom of Transformer of size 3mX2.5mX1.25m with brick work in cement mortar 1:6 earth filling,300 mm thick PCC 1:5:10 type E2, 100 mm thick PCC 1:2:4 type B1 using 20 mm crushed stone aggregate in flooring , including XPM fencing (weight not less than 4 kg/sqm) with support of angle iron frame 50 x 50 x 6 mm at four corners with gate with locking arrangements and all steel surfaces well treated with two coats of synthetic enamel paint over a coat of red oxide primer complete all as per Drg No CEUZ/TD/1516/15 sheet 1/1 |
| 13 | Material & labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 11 KV 95 sqmm 3 core HT XLPE armoured aluminium conductor cable, complete all as specified and as directed. |
| 14 | Materials and labour for pin type porcelain , vitreous, white, brown or green insulator including one galvanized mild steel spindle, two G I washers and one G I nut, 150 mm height and 150 mm dia suitable for 11000 Volts grade complete all as specified and directed. |
| 15 | Supply and installation of transformer level-III, step up/down, out door type complete copper wound AC, 3 phase, 4 wire, 50 Hz, 315 KVA capacity, step down, outdoor 11000/433 volts (at no load) as per IS-1180, Part-1 : 2014 (Level -32) and BEE certified, copper wound, oil cooled with external cooling tubes/fins, core type consisting of following parts :- (a) 03 nos , percelain HV bushing with arching horns on HV side suitable fro 11 KV complete with bushing rod , nuts & washer. (b) One cable end box on LV side consisting of 04 Nos porcelain bushing suitable for LT armoured cable with bushing rod, glands, joints etc. (c) Oil conservator with filter type drain valve and oil gauge. (d) Dehydrating silica gel breather transparent type with first full of dehyderating agent/ silica gel. (e) Explosive vent. (f) Thermometer pocket on tank cover. |
| 16 | (g) One 3 No 100 mm dia thermometer vapour pressure type having range 0-120 Degree Centigrate with mnimum reading pointer, maximum temperature indicator and resetting device. (h) Rating plate with terminal marking. (i) Two earthing terminal on tank. (j) Oil level gauge. (k) Oil drain valve. (l) Lifting lugs. (m) Oil filter hole with cap/ plug incl connection. (n) Air release valve plug. (o) For playing solid cast steel detachable rollers. (p) Extra bushing for neutral outside cable box for providing independent earthing for neutral. (q) First fill of transformer oil confirming to relevent IS and tested upto 60 KV di-electric strength. (r) Ms channel of suitable size for embending in foundation as per manufacturer recommendation. (s) Off load changer +2.5% to +7.5% (t) Danger notice plate-01 |
| 17 | Supply, installation, commissioning and testing of Voltage Stabiliser fully automatic operation, unbalanced type (individual phase control), copper wound 415 V, 50 Hz confirming to BIS 9815 : Part 1 : 1994 reaffirmed 2009, IP-45, three phase naturally oil cooled, indoor type & designed for input variation between 300 volts to 480 volts with output voltage stabilised at 415 volt with accuracy ± 1.0% and speed of correction 15 volts per second of capacity 100 KVA including first filling of transformer oil having dielectric strength not less than 150 KV as per IS:335, 0-500 volts voltmeter, arrangment to check input voltage and output voltage, RYB indication lamp, high & low voltage cut off system, single phase preventor, time delay relay, servo byepass switch, overload & short circuit trip system, ammeter, oil level gauge& capacity overload 20% overload for one hour etc, complete all as specified & directed. |
| 18 | Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, size not less than 2.0X1.2X0.75 mtr, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 500 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (200Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:- (a) MCCB 200 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 02 Nos (Outgoing) (c) On Load changeover switch 100 amp 4 pole, 415 V, 50 Hz- 01 Nos (d) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (e) On Load changeover switch 63 amp 4 pole, 415 V, 50 Hz- 01 Nos Please Enable Macros to View BoQ information |
| 19 | Supply, installation, testing and commissioning of CPRI approved, factory made, LT panel board cubical, Outdoor type, size not less than 2.0X1.2X0.75 mtr, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15mm thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 600mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 500 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, 1100V Danger notice board on front of the panel & the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (200Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable etc., and comprising of the following:- (a) MCCB 200 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 36KA (Adjustable thermal & fixed magnetic release) - 01 Nos (Incomer) (b) MCCB 100 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16KA (Adjustable thermal & fixed magnetic release) - 02 Nos (Outgoing) (c) On Load changeover switch 100 amp 4 pole, 415 V, 50 Hz- 01 Nos (d) MCCB 63 amps, 4 pole, 415V, 50Hz, AC Supply with breaking capacity 16 KA (Adjustable thermal & magnetic release) - 01 Nos (outgoing) (e) On Load changeover switch 63 amp 4 pole, 415 V, 50 Hz- 01 Nos Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
CompletedCorrigendum-3 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysCorrigendum-4 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysCorrigendum-5 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender