Tender For Repair Maintenance Of External Water Supply Installation And Pipeline At Tech And Non Tech Area Under Ge (I) (Cg) Goa
Tender Value
20 Lakhs
Estimated cost
Bid Submission
17 Oct 2026
14 days left
EMD
40000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
goa → Goa
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Maintenance Of External Water Supply Installation And Pipeline At Tech And Non Tech Area Under Ge (I) (Cg) Goa
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in soft/ disintegrated rock for taking up/relaying LT UG cable/ pipe complete all as specified and as directed. |
| 2 | Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard/ dense soil for taking up/relaying LT UG cable/ pipe complete all as specified and as directed. |
| 3 | Returning and filling including spreading levelling watering and well ramming in layers not exceeding 25 cm thick using hard/dense soil complete all as specified and as directed. |
| 4 | Removing excavated material not exceeding 50 metre and depositing where directed at all level not exceeding 1.50 metre above the starting point complete all as specified and as directed. |
| 5 | Taking down old PPR pipe connection of 63/50/40/32 mm bore sizes complete all as specified and as directed. Note :- Excavation and earth work shall be measured and paid separately under relevant items of Schedule |
| 6 | Supply and laying 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stabilised and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings (union, elbow, socket) , flanges,nut and bolts laid in trenches complete all as specified and as directed of the following sizes :- |
| 7 | (a) 63mm bore size |
| 8 | (b) 50mm bore size |
| 9 | (c) 40mm bore size |
| 10 | (d) 32mm bore size |
| 11 | All as per Item No 6.00 described here-in-before but with fixed to wall/Ceiling or laid on floor with all fitting (union, elbow, socket) , flanges,nut and bolts complete all as specified and as directed of the following sizes :- |
| 12 | (a) 50 mm bore size |
| 13 | (b) 40 mm bore size |
| 14 | (c) 32 mm bore size |
| 15 | Taking down old GI tubing and connection of any sizes complete all as specified and as directed for the following sizes :- Note :- Excavation and earth work shall be measured and paid separately under relevant items of Schedule |
| 16 | Supply and laying GI tube medium grade with all fitting (union, elbow, socket) , flanges,nut and bolts laid in trenches complete all as specified and as directed of the following sizes :- |
| 17 | (a) 80 mm bore size |
| 18 | (b) 50 mm bore size |
| 19 | (c) 40 mm bore size |
| 20 | (d) 32 mm bore size |
| 21 | (e) 25 mm bore size |
| 22 | All as per Item No 9.00 described here-in-before but with fixed to wall/Ceiling or laid on floor with all fitting (union, elbow, socket) , flanges,nut and bolts complete all as specified and as directed of the following sizes :- |
| 23 | (a) 50 mm bore size |
| 24 | (b) 40 mm bore size |
| 25 | (c) 32 mm bore size |
| 26 | (d) 25 mm bore size |
| 27 | Taking down old CPVC pipe SDR 11 and Plain CPVC SDR 11 connection of any size complete all as specified and as directed for the following sizes :- Note :- Excavation and earth work shall be measured and paid separately under relevant items of Schedule |
| 28 | Supply and laying CPVC pipe SDR 11 and Plain CPVC SDR 11 of 50/40/32 connection with all fitting (union, elbow, socket) , flanges,nut and bolts laid in trenches complete all as specified and as directed of the following sizes :- |
| 29 | (a) 50 mm bore size |
| 30 | (b) 40 mm bore size |
| 31 | (c) 32 mm bore size |
| 32 | (d) 25 mm bore size |
| 33 | All as per Item No 12.00 described here-in-before but with fixed to wall/Ceiling or laid on floor with all fitting (union, elbow, socket) , flanges,nut and bolts complete all as specified and as directed of the following sizes :- |
| 34 | (a) 50 mm bore size |
| 35 | (b) 40 mm bore size |
| 36 | (c) 32 mm bore size |
| 37 | (d) 25 mm bore size |
| 38 | Supply and fix in repairs gun metal gate valve with iron head wheel screwed both ends for iron pipe, fixed in repairs with ISI mark complete all as specified and as directed of the following sizes :- |
| 39 | (a) 50mm size |
| 40 | (b) 40mm size |
| 41 | (c) 32 mm size |
| 42 | (d) 25 mm size |
| 43 | Supply and Fix in repairs PP-R gate valve (brass insert) as per requirement of the site with ISI mark including taking down complete all as specified and as directed of the following sizes :- |
| 44 | (a) 63mm size |
| 45 | (b) 50 mm size |
| 46 | (c) 40mm size |
| 47 | (d) 32 mm size |
| 48 | Material and labour in repair leakage of ductile iron joint like DI socket flange, Mechanical joint collar, coupler including all accessories, relaying and jointing on wall of OH tank of min height 18m, rectification where leaking by changing rubber gasket joint etc. suitable for 100/150 mm dia bore size of pipe complete all as specified and as directed |
| 49 | Material and labour for cutting existing steel tubing for alteration or addition (Each cut measured) of the sizes and screwing existing steel tubing for alteration of size 40/50mm bore size complete all as specified and as directed |
| 50 | Making connection of PP-R distribution branch with PP-R main by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and as directed of the following sizes :- |
| 51 | (a) 16 to 40mm outer dia of pipe |
| 52 | (b) 50 to 75mm outer dia of pipe |
| 53 | Supply and fix high density polyethylene pipes (HDPE) 50mm bore of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors or bore well including taking down complete all as specified and as directed. |
| 54 | Supply and fix in repairs 150 mm bore ductile iron pipes with spigot and socket ends centrifugally cast class LA, in any length laid in trenches including taking down complete all as specified and as directed. |
| 55 | Material and labour for repair of leakages in galvanised iron pipes 40/50/80mm size with all accessories as required on ground complete all as specified and as directed |
| 56 | Material and labour for repair of leakages in PPR 32/40/50/63mm pipe of size with all accessories as required on ground complete all as specified and as directed |
| 57 | Supply and fix in repairs to existing pipe line unions brass to connect to iron and fixed bore diameter of pipe 50mm including taking down complete all as specified and as directed. |
| 58 | Supply and fix in repairs to existing pipe line Elbow, brass both ends screwed bore diameter of pipe 50mm including taking down complete all as specified and as directed. |
| 59 | Supply and fix in repairs to existing pipe line socket, brass both ends screwed bore diameter of pipe 50mm including taking down complete all as specified and as directed. |
| 60 | Supply and fix in repair to existing pipe line GI socket 40 /50 mm size medium grade including taking down complete all as specified and as directed. |
| 61 | Supply and fix in repair to existing pipe line GI socket 80 mm medium duty size including taking down complete all as specified and as directed. |
| 62 | Supply and fix in repairs to existing pipe line GI reducer 50mm to 25mm including taking down complete all as specified and as directed. |
| 63 | Supply and fix in repairs of reducing Tee 50 mm to 25mm dia fitting all size including taking down complete all as specified and as directed. |
| 64 | Supply and fix in repairs of end cap 25/32/40mm including taking down complete all as specified and as directed. |
| 65 | Supply and fix in repairs of end cap 50/80mm including taking down complete all as specified and as directed. |
| 66 | Repair of valve chamber by cleaning and removing small bushes inside and surrounding the valve chamber and necessary brick works, plastering in cement mortar 1:4, painting with antifungal paint of 2 coats inside and out side including dismantling of unserviceable MS sheet cover, supply and fix new MS sheet cover of 3.15mm thick with 2 coats of synthetic enamel paint over a coat of red oxide to steel surface and locking arrangements, including necessary welding 60 cm x 60 cm x 60 cm of suitable size handle hinges etc. complete all as specified and as directed. |
| 67 | All as per Item No 32.00 described here-in-before but with of size 90x90x90 cm (internal dimension) complete all as specified and as directed. |
| 68 | Material and labour for providing cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in roof kerbs or mud stops, base for valve pit, making good the road cutting and like, rounded or chamfered on edges complete all as specified and as directed. |
| 69 | Supply and fix in repair fully automatic star-delta starter in sheet metal enclose, AC-3 phase, 415 Volts, 50 Hz, with-over load protector, single phase protection relay and electronic timer, including taking out old unserviceable one of motor upto 15 HP capacity complete all as specified and as directed. |
| 70 | Supply and fix in repair DOL/ submersible starter in sheet metal encloser, AC-3 phase, 415 Volts, 50 Hz, including taking out old unserviceable one complete all as specified and as directed of the following capacity :- |
| 71 | (a) For Motor upto 5 to 7.5 HP Submersible Starter, AC, 3 Phase, 415 Volts |
| 72 | (b) For Motor 10 to 15 HP, submersible starter, AC, 3 Phase, 415 Volts |
| 73 | Repairs to AC, 3 phase, 415 Volts, 50 Hz electric monoblock 5 to 7.5 HP pumping motor including rewinding of starter of the motor, transport burnt motor to civil work shop, removing burnt / unserviceable windings completely including insulation material and rewinding stator with super enamelled copper wire of standard specification with standard insulation material complete and fixing back to original position and testing, commissioning etc. including replacing defective bushes, bearing by new one complete and the contractor has furnished a 6 month warranty for all parts and rewinding complete all as specified and as directed. |
| 74 | Repairs to AC, 3 phase, 415 Volts, 50 Hz Electric monoblock 10 to 15 HP pumping motor including rewinding of starter of the motor, transport burnt motor to civil work shop, removing burnt / unserviceable windings completely including insulation material and rewinding stator with super enamelled copper wire of standard specification with standard insulation material complete and fixing back to original position and testing, commissioning etc. including replacing defective bushes by new one complete all as specified and as directed. |
| 75 | Material and labour for removing existing centrifugal pump set from base frame after disconnecting suction and delivery lines replacing bearings, repairing and grinding the shaft etc. complete and reassembling and fixing back to original position and testing, commissioning etc. complete all as specified and as directed for the capacity of 5 to 7.5HP pump set Notes :- (1) Replacement of major parts will be measured and paid separately (2) Any minor part if required will be provided by contractor without any extra cost. |
| 76 | Material and labour for removing existing centrifugal pump set from base frame after disconnecting suction and delivery lines replacing bearings, repairing and grinding the shaft etc. complete and reassembling and fixing back to original position and testing, commissioning etc. complete and the contractor has furnished a 6 month warranty for all parts and rewinding complete all as specified and as directed for the capacity of 10 to 15 HP pump set Notes :- (1) Replacement of major parts will be measured and paid separately (2) Any minor part if required will be provided by contractor without any extra cost. Please Enable Macros to View BoQ information |
| 77 | Material and labour for removing existing centrifugal pump set from base frame after disconnecting suction and delivery lines replacing bearings, repairing and grinding the shaft etc. complete and reassembling and fixing back to original position and testing, commissioning etc. complete and the contractor has furnished a 6 month warranty for all parts and rewinding complete all as specified and as directed for the capacity of 10 to 15 HP pump set Notes :- (1) Replacement of major parts will be measured and paid separately (2) Any minor part if required will be provided by contractor without any extra cost. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 26, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysOct 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender