Tender For Shifting Of Dg Sets And Other Associated Works At Various Bts/Hub Sites/Exchanges Under Ba Varanasi.
Tender Value
8.18 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
0 days left
EMD
16379
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Varanasi → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Shifting Of Dg Sets And Other Associated Works At Various Bts/Hub Sites/Exchanges Under Ba Varanasi.
BOQ
| Sl. No. | Item Description |
| 1 | Shifting of following capacity DG set from one site to another i/c dismantling , loading / unloading and installation of DG set at new location etc. complete as reqd . ( Upto 30 Km distance ).(a) Upto 25 KVA DG set |
| 2 | (a) Extra per Km. charges for distance more than 30 Km |
| 3 | Replacement of faulty / defective spare parts / components/ accessories of existing DG sets i/c dismantling / disconnecting the faulty /defective ones, fixing and connection of new ones, testing and commissioning etc. complete as required.( Make- Recommended by manufacturer/ BSNL makes only).(a)1x25 sqmm flexible Multi core cu conductor PVC insulated Battery Leads (Flexible) of length not less than 0.6 Meters with two nos terminals . |
| 4 | Flexible wire braided fuel pipe of 19 mm dia for the connection of fuel line connection ( inlet and outlet ) complete as required at site. |
| 5 | Banjo bolts with washer |
| 6 | Suitable size belt |
| 7 | Repairing of following items of EA set i/c replacement of faulty parts, making connection, testing etc complete as reqd.(a) Starting Self 12v up to 25 KVA |
| 8 | (b) Charging Alternator |
| 9 | © Repairing and Cleaning of Engine Radiator up to 20 KVA EA Set etc complete as required. |
| 10 | (d) Battery Charger |
| 11 | Repairing and servicing of FIP i/c replacement of faulty components , testing , calibration etc. complete as reqd . (a) Up to 25 KVA EA Set |
| 12 | Re-winding of alternator with \\"H\\" class insulated copper wire and \\"H\\" class insulated material (Paper, Varnish ,appoxi base hardner) i/c replacement of diodes, petty repairing , testing, dismantling and realignment, transportation upto work shop, loading /unloading etc. complete as required. (Note: The dismantled burnt copper winding will be the property of the firm, so the rates to be quoted accordingly). (a) Up to 25 KVA EA Set |
| 13 | S/F of following capacity rating four pole on Load change over switch in steel enclosure capable of working 415/500 V ,AC 23 Duty i/c drilling hole on the board, making connection, earthing the body etc. as reqd.Make: HPL SOCOMAC or SS make).(a) 63 Amp Four pole on load Make: HPL SOCOMAC or SS make) |
| 14 | Supplying & fixing of three Phase AVR suitable for voltage regulation in DG set upto 20 KVA Capacity EA set i/c testing etc. complete as reqd. |
| 15 | Carrying out ' B' Check General Servicing of following capacity of diesel Engine Alternator sets of different makes and models under various exchanges / BTS including replacement of complete old lubricant oil, fuel filter, lubricant oil filter i/c Transportation charges, Tools and plants, testing etc complete as required at site. (Lubricant oil and filters shall be as per the manufacturer's recommendation). ( Kirloskar/ M&M/Escorts/ Eicher/Ashok Leyland/ Greaves etc).(a) 12.5/15 KVA |
| 16 | (b) above 15 KVA and up to 20 KVA |
| 17 | Providing of maintenance free New Lead acid Batteries of following types / rating complete with first fill of electrolyte & first charging i/c testing and commissioning at site complete as reqd. (a) 88Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP880 or Equivalent of BSNl approved. Make) |
| 18 | (b) 130 Ah, 12 volt maintenance free Battery (M/s Exide FXPO-XP1300 or Equivalent of BSNL approved Make) |
| 19 | Supply and laying of one number 4x16 Sqmm XLPE insulated and PVC sheathed power cable of 1.1 KV grade of following size aluminium conductor armored cable in the following manners:-(a) In the existing masonry open duct/ surface/ wall as required. |
| 20 | (b) Direct in CC floor i/c cutting the CC floor and making good the damages etc. complete as required. |
| 21 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.(a) 4x16 sq. mm |
| 22 | Making arrangement of fuel for minimum 30 minutes run of EA set (Not less than 5.00 Ltrs) i/c cartage, container and filling the fuel in existing tank etc as complete as required at site. (This item executed only those sites where fuel not made available by the BSNL authorities) |
| 23 | Less (Buy back ) price for 12 Volt old existing unsevicable battery irrespective of make and model available at site.(a) AH capacity up to 110 AH |
| 24 | (b) AH Capacity Above 110 AH & up to 130 AH Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 25, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026