Tender For Attending Faults/Replacement Of Faulty Accessories In The Existing Amf Panels And providing and Fixing New Amf Panel In Lieu Of Existing Manual Control Panel In 15/20/30/40 Kva Ea Set At The Bts Sites Under Salem Ba(Rate Contract)
Tender Overview
Project Description
Tender for Attending Faults/Replacement Of Faulty Accessories In The Existing Amf Panels And providing and Fixing New Amf Panel In Lieu Of Existing Manual Control Panel In 15/20/30/40 Kva Ea Set At The Bts Sites Under Salem Ba(Rate Contract)
BOQ
| Sl. No. | Item Description |
| 1 | Diagnosis of faults in the existing AMF panel by arranging man power and tools including testing, identification of defective components and submission of fault report etc., as reqd |
| 2 | Replacing the following Accessories in the existing AMF panel i/c testing, commissioning etc., as reqd |
| 3 | (i) 4 Pole 40 A Contactors(Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 4 | (ii) 4 Pole 63 A Contactors(Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 5 | (iii) 4 Pole 80 A Contactors(Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 6 | (iv)230 Volts /415 Volts Coil for 40 A Contactor(Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 7 | v) 230 Volts /415 Volts Coil for 63 to 80 amps Contactor(Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 8 | (vi) 4 pole 40 amps MCB( M/s L&T/Lauritz Knudsen /ABB/Siemens or sim sup make) |
| 9 | (vii) 4 pole 63 amps MCB ( M/s L&T/Lauritz Knudsen /ABB/Siemens or sim sup make) |
| 10 | (viii) 6 -16 amps SP MCB( M/s L&T/Lauritz Knudsen /ABB/Siemens or sim sup make) |
| 11 | (ix) Control wiring Terminal Block Connectors |
| 12 | (x) Power wiring Terminal Block Connectors, 4 way |
| 13 | (xi) LED Indication lamps (R,Y,B)( Make L&T/Vaishno or sim sup make) |
| 14 | (xii) 40 Amps Rotary switch 4 Pole 3 Way wiith OFF (make : Salzer/Kaycee or sim sup make) |
| 15 | (xiii) 63Amps Rotary switch 4 Pole 3 Way wiith OFF (make : Salzer/Kaycee or sim sup make) |
| 16 | (xiv) 6A Selector switch 2 Pole 2Way with OFF (make : Salzer/Kaycee or sim sup make) |
| 17 | (xv) Glass Fuses |
| 18 | (xvi) 6A HRC fuses |
| 19 | (xvii) Replacement of Control wires |
| 20 | (xviii) 10 sqmm Copper wires for Power wiring inside the Control Panel |
| 21 | (xix) Copper Lugs for 10 Sqmm |
| 22 | (xx) 16 sqmm Copper wires for Power wiring inside the Control Panel |
| 23 | (xxi) Copper Lugs for 16 Sqmm |
| 24 | (xxii) Add On block 1 NO+1 NC (Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 25 | (xxiii) Start OR Stop Push Buttons (to be measured separately) |
| 26 | S/F Engine AMF cum BTS Controller based on Micro Controller technology, suitable for operation on wide range of auxiliary supply voltage 8 volts to 26V DC supply, with a provision to Monitor EB Mains and BTS battery condition and automatically put EA set in operation when the EB supply fails or when the EB mains voltage or BTS Battery Voltages fall below the preset limit value (shall have provision to set either of the above two option), having alpha numeric LCD display, displaying the live parameters viz., True RMS phase and Line voltages, Load Current, Power, DG KWH, Mains KWH, Power Factor, Engine Run Hours, EB mains available hours, DG battery Voltage, Lub Oil Pressure, frequency, minimum 3 fault alarms at a time, having minimum of 10 digital input and 7 Digital Output terminals for infra alarms monitoring and extension, built-in programmable protection of EA set from starting /getting tripped during fault conditions viz., LLOP, HCT/HWT, Low fuel, Under/ Over Voltage, Over/under frequency, Over Current, unbalance current, over/under DG battery Voltage etc., incorporating USB port, RS 485 communication Port, with keypad switches for Manual start/stop, up /down Navigation, auto /manual selection, Mains/DG Contacor Close for manual operation etc., as per the specifications attached, testing, commissioning ETC. as reqd. (Enertrak EAMF-9940 or similar superior make complying with the specifications) |
| 27 | S/L 2x 1.5 sqmm PVC/XLPE insulated PVC sheathed armoured copper conductor cable for extending auxiliary supply from BTS Power plant to the controller etc., as required. |
| 28 | S/F 8 Channel Relay card comprising 8 Nos, Miniature Relays suitable for operation on 12/24 Volts DC with PCB terminals for Coil and contacts terminations for infra alarm extension as an interface between controller and alarm terminal block of BTS equipment etc., as reqd. |
| 29 | S/F DG set Start /Stop and EB/DG Contactor Relay card comprising 4 Nos, Miniature Relays suitable on operation on 12 /24 Volts DC with PCB terminals for Coil and contacts terminations etc., as reqd. |
| 30 | S/L 10 pair, 0.5 sqmm Stranded/Solid Plain Copper, PVC/XLPE Insulated PVC /XLPE insulated togather with Al (Inner sheathed GI Steel Wire Mylar/Drain Wire) armoured PVC Outer Sheathed Instrumentation Cable suitable for operation on 12/24/48 volts DC supply for extension of infra alarm from relay card to terminal Block of BTS equipment etc., as reqd. |
| 31 | Supplying and laying of following size aluminium conductor armoured PVC XLPE insulated PVC sheathed 1.1KV GRADE power cable on surface of wall etc as reqd |
| 32 | (i) 4 x16 sqmm |
| 33 | (ii) 3½ x 35 Sqmm |
| 34 | Supplying, installation, testing, and commissioning of Auto Mains Failure (AMF) Control Panel suitable for mounting inside the canopy type EA set, dust and vermin-proof, made of powder coated MS sheet of thickness atleast 18 G, of size not less than 700 mm x 450 mm x 200 mm as per the site requirement, suitable for 15 kVA/20 KVA, 3-phase, 4-wire, 415 V, 50 Hz Diesel Generator set , complete with following accessories , control wiring and Power wiring inside the panel, Screwed Terminal Blocks for control wiring, Terminal Blocks for Glass Fuses etc., as per specifications etc., as reqd |
| 35 | (i) Micro Controller technology based Engine AMF cum BTS Controller as per item 3 above( make :Enertrak EAMF-9940 or similar superior make complying with the specifications) |
| 36 | (ii) 2 Nos., 4 Pole 40 Amps Contactors AC 3 rating(Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 37 | (iii) 2 Nos 40 A 4 Pole C series MCB( M/s L&T/Lauritz Knudsen /ABB/Siemens or sim sup make) |
| 38 | (iv) 1 No 16 amps C Series SP MCB( M/s L&T/Lauritz Knudsen /ABB/Siemens or sim sup make) |
| 39 | (v) 4 Nos, 230 V AC LED indication lamp( Make L&T/Vaishno or sim sup make) |
| 40 | (vi) Glass fuse with Holders- minimum 8 Nos |
| 41 | (vii)100 A bolted 4 way bakelite heavy duty Terminal connector Block for R, Y ,B and N - 3 sets (For EB, EA and Load) |
| 42 | (viii) 40/5 amps CT -3 Nos( make M/s Kappa/AE or sim sup make) |
| 43 | (ix) 4 Channel relay Card |
| 44 | (x) 8 Channel Relay Card |
| 45 | (xi) 40 Amps Rotary switch 4 Pole 3 Way wiith OFF (make : Salzer/Kaycee or sim sup make) |
| 46 | (xii) 6A Selector switch 2 Pole 2Way with OFF (make : Salzer/Kaycee or sim sup make) |
| 47 | (xiv) 6A HRC fuses |
| 48 | (xv) Add On block 1 NO+1 NC (Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 49 | (xvi) Start/ Stop Push Butons |
| 50 | -All the above consists of- |
| 51 | Supplying, installation, testing, and commissioning of Auto Mains Failure (AMF) Control Panel suitable for mounting inside the canopy type EA set, dust and vermin-proof, made of powder coated MS sheet of thickness atleast 18 G, of size not less than of size not less than 700 mm x500 mm x200 mm in case of horizontal mounting as per site requirement, suitable for 30 kVA/40 KVA, 3-phase, 4-wire, 415 V, 50 Hz Diesel Generator set , complete with the following accessories , control wiring and Power wiring inside the panel, Screwed Terminal Blocks for control wiring, Terminal Blocks for Glass Fuses etc., as per specifications etc., as reqd |
| 52 | (i) Micro Controller technology based Engine AMF cum BTS Controller as per item 3 above ( make :Enertrak EAMF-9940 or similar superior make complying with the specifications) |
| 53 | (ii) 2 Nos., 4 Pole 80 Amps Contactors (Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 54 | (iii) 2 Nos 80 A 4 P MCCB (Make M/s L&T/Lauritz Knudsen /Schneider / Siemens or sim sup make) |
| 55 | (iv) 1 No 6/16 amps C Series SP MCB( M/s L&T/Lauritz Knudsen /ABB/Siemens or sim sup make) |
| 56 | (v) 4 Nos, 230 V AC LED indication lamps( Make L&T/Vaishno or sim sup make) |
| 57 | (vi) Glass fuse with Holders- minimum 8 Nos |
| 58 | (vii)100 A bolted 4 way bakelite heavy duty Terminal connector Block for R, Y ,B and N - 3 sets (For EB, EA and Load) |
| 59 | (viii) 100/5 amps CT -3 Nos ( make M/s Kappa/AE or sim sup make) |
| 60 | (ix) 4 Channel relay Card |
| 61 | (x) 8 Channel Relay Card |
| 62 | (xi) 4 Pole 3 Way wiith OFF 100 Amps Rotary switch (make : Salzer/Kaycee or sim sup make) |
| 63 | (xii) 2 Pole 2Way with OFF 6A Selector switch (make : Salzer/Kaycee or sim sup make) |
| 64 | (xiv) 6A HRC fuses |
| 65 | (xv) Add On block 1 NO+1 NC(Make M/s L&T/Lauritz Knudsen /Schneider / Siemens/Lakshmi(LECS) or sim sup make) |
| 66 | (xvi) Start/ Stop Push Butons |
| 67 | -All the above consists of- 500 KVA EA SET Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender