Defence Statutory Bodies & Commissions/Committees Closing in 27 days TDR #57719105

Tender For Provn Of Klp Accommodation For Ad Regt (Self Propelled) Including Affiliated Wksp (Ph-I Of Two Phase) At Chandimandir (2024-25)

Issued by Statutory Bodies & Commissions/Committees · Panchkula, Haryana
Tender Value
27.11 Crore
Estimated cost
Bid Submission
30 Oct 2026
27 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Klp Accommodation For Ad Regt (Self Propelled) Including Affiliated Wksp (Ph-I Of Two Phase) At Chandimandir (2024-25)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 01-Oct-2026 Corrigendum No 01 Other 30-Oct-2026

BOQ

Name of Work:- PROVN OF KLP ACCOMMODATION FOR AD REGT (SELF PROPELLED) INCLUDING AFFILIATED WKSP (PH-I OF TWO PHASE) AT CHANDIMANDIR (2024-25)
Sl. No. Item Description
1Total amount of Sch 'A' Sec-I (BUILDING WORKS ) Lump sum price worked out by the contractor for \\" BUILDING WORKS \\" as listed in schedule 'A' Part-I
2Total amount of Sch 'A' Sec-II (DEMOLITION WORKS) Lump sum price worked out by the contractor for \\" DEMOLITION WORKSS\\" as listed in schedule 'A' Part-II
3Total amount of Sch 'A' Sec-III (SITE CLEARANCE, EARTHWORK AND EXCAVATION WORKS) Lump sum price worked out by the contractor for \\" SITE CLEARANCE, EARTHWORK AND EXCAVATION WORKS)S \\" as listed in schedule 'A' Part-III
4Total amount of Sch 'A' Sec-IV (INTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for \\" INTERNAL WATER SUPPLY WORKS\\" as listed in schedule 'A' Part-IV
5Total amount of Sch 'A' Sec-V (INTERNAL ELECTRIFICATION WORKS) Lump sum price worked out by the contractor for \\"INTERNAL ELECTRIFICATION WORKS\\" as listed in schedule 'A' Part-V
6Total amount of Sch 'A' Sec-VI (HOT WATER WORKS) Lump sum price worked out by the contractor for \\"HOT WATER WORKS\\" as listed in schedule 'A' Part-VI
7Total amount of Sch 'A' Sec-VII (ROAD, PATH, CULVERTS AND HARD STANDING WORKS ) Lump sum price worked out by the contractor for \\"ROAD, PATH, CULVERTS AND HARD STANDING WORKS \\" as listed in schedule 'A' Part-VII
8Total amount of Sch 'A' Sec-VIII (EXTERNAL WATER SUPPLY WORKS) Lump sum price worked out by the contractor for \\"EXTERNAL WATER SUPPLY WORKS \\" as listed in schedule 'A' Part-IX
9Total amount of Sch 'A' Sec-IX (EXTERNAL ELECTRIC SUPPLY WORKS ) Lump sum price worked out by the contractor for \\" EXTERNAL ELECTRIC SUPPLY WORKS \\" as listed in schedule 'A' Part-IX
10Total amount of Sch 'A' Sec-X (SEWAGE DISPOSAL WORKS ) Lump sum price worked out by the contractor for \\"SEWAGE DISPOSAL WORKS \\" as listed in schedule 'A' Part-X
11Total amount of Sch 'A' Sec-XI (AREA DRAINAGE WORKS ) Lump sum price worked out by the contractor for \\"AREA DRAINAGE WORKS \\" as listed in schedule 'A' Part-XI
12Total amount of Sch 'A' Sec-XII (CHAIN LINK FENCING WITH BARBED WIRE WORKS ) Lump sum price worked out by the contractor for \\"CHAIN LINK FENCING WITH BARBED WIRE WORKS \\" as listed in schedule 'A' Part-XII
13Total amount of Sch 'A' Sec-XIII (ARBORICULTURE WORKS ) Lump sum price worked out by the contractor for \\"ARBORICULTURE WORKS \\" as listed in schedule 'A' Part-XIII
14Schedule 'A'Section-XIV (Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as \\"Rs 0.00\\" under Col. 5 siginifies this fact only.
15ARBORICULTURE WORKSSupply and fixing 50 mm outer dia, double walled corrugated (DWC) HDPE duct pipe conforming to IS-14930 Part-II with anti rodent and non flame propogating properties of approved colour with fittings for cable protection complete all as specified and as directed by Engineer-in-Charge.
16Supply installation, testing and commissioning factory made feeder pillar made out of 3.15mm thick incorporated with 3 phase 4 wire system aluminium busbar 50 amp, insulator with two nos of incoming 32 amp SPN, 220 volt fixed on angle iron frame grouted in the PCC 1:2:4 upto 30 cm duly painted with powder coated paint and angle iron frame with two coat of synthetic enamel paint over a coat of red oxide primer paint complete all as specified and directed.Note : Drawing for LT panel shall be approved by GE before placement of order. (For Arboriculture Lighting.)
17Supply and fixing of bollard light upto 24 watt capacity complete all as specified and directed.
18SUMMER APPLIANCESSupply, installation and testing of refrigerator of Capacity 165 Litres, Single Door, electric driven, single phase, 230 Volts, BEE 5 star rated having features such as smart inverter compressor with minimum 10 years of warranty, inbuilt stablizer, frost free etc. working on R-134 or superior environment friendly refrigerant gas equipped with accessories such as ice tray, egg tray, interior lamp, toughened glass partition (shelves) complete all as specified and as directed by Engineer-in-Charge.
19Supply and fixing Voltage stabilizer automatic operation, single phase naturally air cooled indoor type & designed with copper winding of suitable gauge for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of (+-) 25% and capacity 5 KVA.
20Supply, installation, testing and commissioning of water cooler of capacity 80 Litres and with minimum cooling capacity of 40 Litres per Hour(LPH) BEE 5 Star rated, having anti corrosive stainless steel body and tank, electric driven, single phase, 230 Volts complete with all connected fittings as per manufacturer's recommendations complete all as specified and as directed by Engineer-in-Charge.
21Supply, installation, testing and commissioning of Deep freezer with glass door opening, double door of capacity 100 Litres, BEE 5 star rated, Electric driven, single phase, 230 Volts with required fittings and fixtures for preserving all types of food in hygine condition, relaiable and robust design, special brakets, rugged and heavy duty shelves, 4 heavy duty caster wheels at the bottom of the freezer for easy movability, low emissivity glass for better visibility and insulation, UV grade plastic for long lasting appearence, anti corrosive, pre-coated body, aluminium inner lining with high density PUF insulation for better holding time, door lock feature for restricted accessibility, compressor having minimum 5 years of warranty complete all as specified and as directed by Engineer-in-Charge.
22Supply, installation, testing and commissioning of air cooled air conditioner with split type indoor and outdoor unit, of cooling capacity of 4500 K cal per hrs (2 Ton), electric driven, 230 Volts, single phase, 50Hz supply, all weather cold type, BEE 5 star rated, working on R-134 or superior environment friendly refrigerant gas including copper tubing and Electrical connection between indoor and outdoor unit located upto a maximum 10 meter distance complete including condensate water drainage pipe of maximum 3 meter long complete all as specified and as directed by Engineer-in-Charge.
23Supply, installation, testing and commissioning of air cooled air conditioner with split type indoor and outdoor unit, of cooling capacity of 4500 K cal per hrs (1.5 Ton), electric driven, 230 Volts, single phase, 50Hz supply, all weather type cold type, BEE 5 star rated, working on R-134 or superior environment friendly refrigerant gas including copper tubing and Electrical connection between indoor and outdoor unit located upto a maximum 10 meter distance complete including condensate water drainage pipe of maximum 3 meter long complete all as specified and as directed by Engineer-in-Charge.
24HOT WATER WORKSSupply, installation, testing and commissioning of solar water heater with heat exchanger type, conforming to IS 12933 & 13129 for cold region, 500 litre/ day capacity with electric heating backup of 2 KW and rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 500 Ltr capacity, tripple layer, as make up water tank. hoisted and fixed in position on suitable steel staging as directed by GE. complete all as specified and directed. Notes: (i) The system shall be tested on completion to ensure that 500 litres of water at 60 Degree centigrade is available in hot water tank on normal day in cold season.(ii) All other pipe/civil work, electrical work, providing electric connection with wire, MCB, conduit etc as per manufacturer's instruction all as required shall deemed to be included in unit rate quoted).(iii) Normal water pipes and accessories for normal water over head tank to inlet of plate collector shall be measured and paid for separtely.
25Supply, installation, testing and commissioning of solar water heater with heat exchanger type, conforming to IS 12933 & 13129 for cold region, 500 litre/ day capacity with electric heating backup of 2 KW and rotational moulded polyethylene water storage tank (cylindrical vertical tank with close top) of 200 Ltr capacity, tripple layer, as make up water tank. hoisted and fixed in position on suitable steel staging as directed by GE. complete all as specified and directed. Notes: (i) The system shall be tested on completion to ensure that 200 litres of water at 60 Degree centigrade is available in hot water tank on normal day in cold season.(ii) All other pipe/civil work, electrical work, providing electric connection with wire, MCB, conduit etc as per manufacturer's instruction all as required shall deemed to be included in unit rate quoted).(iii) Normal water pipes and accessories for normal water over head tank to inlet of plate collector shall be measured and paid for separtely.
26Supply and laying of Hot water pipe duly insulated with19 mm nitrile insulation and 26 gauge aluminium cladding suitable for 20 mm bore pipe medium grade laid in trenches/wall/floor and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps complete all as specified and directed
27Supply and laying of Hot water pipe duly insulated with19 mm nitrile insulation and 26 gauge aluminium cladding suitable for 25 mm bore pipe medium grade laid in trenches/wall/floor and joined including necessary fittings such as bends, elbow, tees sockets etc including necessary saddles and clamps complete all as specified and directed
28Supply and fix electric water heater (Geyser) storage type,steel body with copper inner tank and heating elements upto 2 kw electric,capacity 25 liters, BEE 5 star rated complete with all accessories such as safety valve,thermostat, NRV, connection piece and hot and cold connection fittings complete all as specified and as directed. Note - Water supply pipe line upto inlet of Geyser shall be part of internal water supply schedule.Note:- (i) Water supply pipe line upto inlet of Geyser shall be part of internal water supply schedule.(ii) Water supply pipe line from outlet of Geyser shall be part of internal water supply schedule.
29ROAD, PATH, CULVERTS AND HARDSTANDING WORKS Providing, Laying, compaction of granular sub-base of 150 mm thick compacted thickness by providing close graded material conforming to specifications i.e Grading II, conforming to Clause 401 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller of capacity 8 to 12 tonne to achieve compaction density of atleast 98% of maximum dry density and consolidating to required gradient and camber, complete all as specified and directed.
30Providing, Laying, compaction of Wet Mix Macadam conforming to Clause 406 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) , 250 mm thick (compacted thickness,125 mm thick in two separate layers) with mechanically crushed graded stone aggregates and granular material (size range 53 mm to 0.075 mm ), grading of aggregates as per Table 400-13 of MORT&H Specifications for Road and Bridge Works (Fifth Revision) ,including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 12 tonne capacity to achieve the desired density , required gradient and camber etc., complete all as specified and directed.NOTES:1. The WMM shall be laid in two layers i.e each layer of 125 mm thick (compacted thickness).2. For payment purpose,both layers shall be considered as one unit.
31Preparation of un-surfaced Wet Mix macadam (WMM) surfaces by brushing with wire brushes for re-moving caked mud ,dust, loose material, foreign material etc., sweeping with power brooms and finally fanning the cleaned surface with air compressors to remove all loose dirt etc. and applying evenly a priming coat on un-surfaced wet mix macadam surfaces conforming to Clause 502 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion SS1 grade,confirming to IS 8887(latest edition) @ 7.5 kg per 10 sq metres using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed.
32Providing, laying & compaction of Bituminous Macadam (BM) 50 mm Compacted thickness conforming to Clause 504 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), using mechanically crushed stone aggregates and granual material etc. of grading II as per Table 500-7 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), premixed with bituminous binder, Bitumen grade VG-30 @ 3.50% (percentage by weight of total mix) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity transported to site by tippers, laid over a previously prepared surface with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density complete all as specified and directed by Engineer-in-Charge.Notes : (i) The contractor shall quote the rate against Item considering 3.5% VG-30 bitumen content. Job mix formula as per MoRT&H specifications for road and bridge work (Fifth Revision) for bituminous concrete shall be got designed from NIT/ CTL/ Govt Engg College and shall be got approved from GE in writing well before commencement of work without any financial effect to the department. Also the bitumen content shall not be less 3.4% by weight of total mix as per clause 504.2.4 of MoRT&H specifications (Fifth Revision). (ii) If qty of binder contents is less than the qty as specified in respective items of BOQ, it shall be adjusted at supply only rates of paving bitumen @ Rs 45.00 Per Kg and if qty of binder contents is more than the qty as specified in respective items of BOQ no adjustment shall be made.
33Preparation of surfaces and applying evenly a Tack coat conforming to Clause 503 of MORT&H Specifications for Road and Bridge Works (Fifth Revision), with cationic bituminous emulsion RS1 grade,confirming to IS 8887(latest edition) @ 2.5 kg per 10 sq metres using using primer distributor which shall be self-propelled or towed bitumen pressure sprayer complete all as specified and directed.
34Providing and laying 30 mm thick (consolidated thickness) Bituminous premix asphaltic dense concrete conforming to Clause 507 of MoRTH Specification for Road and Bridge Works (Fifth Revision) premixed with bituminous binder using Bitumen grade VG-30@ 5.50 % by weight of total mix , laid /rolled and compacted to required gradient and camber level and alignment and rolling with smooth wheeled , vibratory and tandom rollers as per specifications to achieve the desired density complete all as specified.
35M & L Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed.
36EXTERNAL WATER SUPPLY WORKSM& L for DI/GI pipe fittings for spigot and socketed/ flanged joint suitable upto 150/100 mm bore such as bends(any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc),Tee pieces single branch. Y junction, double branch, cross (all sockets and spigot ) collars, caps and plugs,tail pieces with one end flange(integrally cast) and one end socket, complete suitable for any size of pipe and push on flexible rubber tyton joints/ flange joints complete all as specified and directed
37Supply & Fix Centrifugally cast (spun) ductile iron pressure pipes with socket& spigot ends having ISI stamping marking with IS 8329/2000 classification K7, In standard length of 5.5 - 6 mtr suitable for and including push on tyton joint and gasket with cement mortar lining inside the pipes of 150 mm bore, cost of rubber joint shall be included in the overall cost quoted for jointing of pipe complete all as specified and directed.
38Supply & Fix Centrifugally cast (spun) ductile iron pressure pipes with socket& spigot ends having ISI stamping marking with IS 8329/2000 classification K7, In standard length of 5.5 - 6 mtr suitable for and including push on tyton joint and gasket with cement mortar lining inside the pipes of 100 mm bore, cost of rubber joint shall be included in the overall cost quoted for jointing of pipe complete all as specified and directed.NOTE:- For Sr No- 2 & 3(I) Ductile iron fittings will be measured and paid separately.(II) Make of fittings same as that of pipe or as recommended by original pipe manufacturers.
39Supply & Fix Cast iron air release valves with two air outlets, 50 mm dia bore and fixing up in cast iron water supply mains of 150mm dia pipe complete all as specified and directed.
40Sluice valve of 150 mm dia bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS - 14846 complete all as specified and as directed.
41Sluice valve of 100 mm dia bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS - 14846 complete all as specified and as directed.
42Sluice valve of 80 mm dia bore, cast iron body, having brass spindle with iron wheel at top, class PN 1.6, with flanged ends, drilled suitably, complete with joints and including necessary joints by means of bolts, nuts washers and rubber gaskets, conformig to IS - 14846 complete all as specified and as directed.
43M&L for cutting existing hard standing/ road upto 45 cm depth for laying pipelines and making good the disturbed surface by providing M15 concrete after laying pipe lines and returning filling of soil complete all as specified and as directed.
44Material & Labour for cutting of existing hard standing/road up to 45 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines and returning filling of soil, complete all as specified and directed.
45Boring of hole under roads, hard stranding, pavements by trenchless technology using ultra sounding technique and necessary machine including 150 mm dia HDPE Pipe suitable for 0.4 Mpa pressure complete all as specified and directed.
46Construction of valve pit of size 1.2m x 1.2m x 1.0 m with concrete block construction with wall thickness not less than 200 mm including all necessary excavation and earth work in hard dense soil returning filling in disposal of surplus soil to a distance not exceeding 50 metre and depositing where as directe including PCC in foundation (1:3:6) type C2 using 40mm graded stone aggregate 150 mm thick, PCC in coping on top 1:2:4, type B1 using 20 mm graded stone aggregate 50 mm thick including rendering 15 mm thick on exposed surface and two coat of white wash on exposed surface on external wall above ground level and angle iron frame 50x50x6 mm MS sheet cover 3.15 mm thick with hinges, handle and locking arrangement. Painting all MS work with two coat of red oxide primer and painting all the MS surface embeded in PC with two coat of black bitumen paint, complete all as specified and directed.
47Construction of valve pit of size 0.9m x 0.9m x 0.9m with concrete block construction with wall thickness not less than 200 mm including all necessary excavation and earth work in hard dense soil returning filling in disposal of surplus soil to a distance not exceeding 50 metres and depositing where as directed. PCC in foundation (1:3:6) type C2 using 40mm graded stone aggregate 150 mm thick, PCC in coping on top 1:2:4, type 81 using20 mm graded stone aggregate50 mm thick including rendering 15 mm thick on exposed surface and two coat of white wash on exposed surface on external wall above ground level and angle iron frame 50x50x6 mm MS sheet cover 3.15 mm thick with hinges, handle and locking arrangement. Painting all MS work with two coat of red oxide primer and painting all the MS surface embeded in PC with two coat of black bitumen paint all as specified and directed.
48EXTERNAL ELECTRIC WORKSMS Box of size 300x200x150mm, made out of 1.6mm thick MS Sheet, with insulated aluminium bus bar 02 Nos two phase 240 Volts of rating 200 amps mounted on insulators, fixed with pole for street light with MCB SP B series 6 Amp, 240 Volts, 10 KA mounted on Din rail, thimbles Complete all as specified and directed by engr-in-charge.
49Supply and fixing of GI steel tubing light grade 40 MM dia bent to shape of offset angle upto 45 degree bracket mounting clamp , bolts and nuts for fixing of security light fitting Complete all as specified and directed by engr-in-charge.
50Supply and fixing of 1.5 Sqmm 2 core copper conductor overall pvc sheathed for submain wiring including PVC Conduit 20 mm dia medium grade along with fixing clamp etc complete all as specified and directed.
51Supply installation, testing and commissioning factory made ,outdoor type, floor mounted, main LT panel board, cubical type totally enclosed outer edge made out of 3.15 mm thick CRCA sheet and inner compartments of 2 mm thick sheet metel enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom cable gland with plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingress of water/vermin etc,inside the enclouser,required nos of holes to be fixed with chromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and fixed with legs below ground 30 cm and above ground 60 cm with aluminium busbar 3000 amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories. MAIN LT PANEL INCOMING:- (i) ACB 415 Volts, 2000 amp, rating 4 pole 50 KA rupturing capacity, microprocessor release , manual draw out type including with overload, short circuit and earth fault protection-01 No. OUTGOING:- (i)MCCB 500 Amps, 4 pole, 36 KA ,Thermal adustable and fixed magnetic type= 1 No (To LT Panel-I Adm Bldg)(ii)MCCB 500 Amps, 4 pole, 36 KA ,Thermal adustable and fixed magnetic type= 1 No (To LT Panel-II SM Barrack)(iii)MCCB 250 Amps, 4 pole, 36 KA ,Thermal adustable and fixed magnetic type= 1 No (To LT Panel-III SM Barrack Air Cooling)(iv)MCCB 350 Amps, 4 pole, 36 KA ,Thermal adustable and fixed magnetic type= 1 No (To LT Panel-IV Cook house&Dining)(v)MCCB 200 Amps, 4 pole, 36 KA ,Thermal adustable and fixed magnetic type= 1 No (To Fire Panel in Pump room) All MCCB should be Microprocessor based. Note:- Drawing for LT Panel shall be approved by GE before placement of order by contactor.
52Supply installation, testing and commissioning factory made ,outdoor type, floor mounted, main LT panel board, cubical type totally enclosed outer edge made out of 3.15 mm thick CRCA sheet and inner compartments of 2 mm thick sheet metel enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom cable gland with plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingress of water/vermin etc,inside the enclouser,required nos of holes to be fixed with chromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and fixed with legs below ground 30 cm and above ground 60 cm with aluminium busbar 750 amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories.LT PANEL-I Incomming(i) MCCB 500 Amps, 36 KA, 4 pole ,Thermal adustable and fixed magnetic type =1 No.Outgoing (i)MCCB 350 Amps, 36 KA, 4 pole ,Thermal adustable and fixed magnetic type = 1 Nos - For Adm Bldg Load (ii)MCCB 80 Amps, 25 KA, 4 pole ,Thermal adustable and fixed magnetic type = 1 Nos- For Air Cooling Load(iii)MCB 20 A DP - 2 Nos - For Car Parking & Security LightNote- All MCCB should be microprocessor Based (Location- Adm Bldg)Note:- Drawing for LT Panel shall be approved by GE before placement of order by contactor.
53Supply installation, testing and commissioning factory made ,outdoor type, floor mounted, main LT panel board, cubical type totally enclosed outer edge made out of 3.15 mm thick CRCA sheet and inner compartments of 2 mm thick sheet metel enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom cable gland with plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingress of water/vermin etc,inside the enclouser,required nos of holes to be fixed with chromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and fixed with legs below ground 30 cm and above ground 60 cm with aluminium busbar 1500 amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories.LT PANEL-II Incomming (i)MCCB 500 Amps, 36 KA, 4 pole ,Thermal adustable and fixed magnetic type =1 No. Outgoing (i)MCCB 100 Amps, 25 KA, 4 pole ,Thermal adustable and fixed magnetic type = 4 Nos (For SM Barracks- 4 Nos) (ii)MCB DP 40 Amps = 1 No (For Security Light) Note- All MCCB should be microprocessor Based. (Location- SM Living Barracks) Note:- Drawing for LT Panel shall be approved by GE before placement of order by contactor.
54Supply installation, testing and commissioning factory made ,outdoor type, floor mounted, main LT panel board, cubical type totally enclosed outer edge made out of 3.15 mm thick CRCA sheet and inner compartments of 2 mm thick sheet metel enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom cable gland with plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingress of water/vermin etc,inside the enclouser,required nos of holes to be fixed with chromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and fixed with legs below ground 30 cm and above ground 60 cm with aluminium busbar 375 amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories.LT PANEL-III Incomming (i)MCCB 250 Amps, 36 KA, 4 pole ,Thermal adustable and fixed magnetic type =1 No. Outgoing (i)MCCB 80 Amps, 25 KA, 4 pole ,Thermal adustable and fixed magnetic type = 4 Nos (For Air Washer-4 Nos) Note- All MCCB should be microprocessor Based. Location- SM Living(Air Cooling System) Note:- Drawing for LT Panel shall be approved by GE before placement of order by contactor.
55Supply installiation, testing and commissioning factory made ,outdoor type, floor mounted, main LT panel board, cubical type totally enclosed outer edge made out of 3.15 mm thick CRCA sheet and inner compartments of 2 mm thick sheet metel enclosed with angle iron frame of MS angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50HZ system , with hinged pannel door (covers) on two sides with handle, bottom cable gland with plate and locking arrangement consisting of sufficient nos of circuit cable entry holes at bottom only with suitable PVC/rubber/wooden brushes to prevant ingress of water/vermin etc,inside the enclouser,required nos of holes to be fixed with chromium plate brass cable glands for cable entry and exit complete with neccesary internal wiring with stranded copper conductor FRLSH wire of adequate size,duly powder coated internally and externally of approved colour with pcc foundation (1:2:4) and fixed with legs below ground 30 cm and above ground 60 cm with aluminium busbar 525 amp ( 01 set comprising 4 nos strip) for 3 phase and neutral mounted on epoxy insulator,CTs, Ammeter, votmeter,indicator lamp including following accesories. LT PANEL-IV Incomming(i) MCCB 350 Amps, 36 KA, 4 pole ,Thermal adustable and fixed magnetic type =1 No. Outgoing (i) MCCB 80 Amps, 25 KA, 4 pole ,Thermal adustable and fixed magnetic type = 4 Nos( For Cook House & Dining- 4 Nos) Note- All MCCB should be microprocessor Based. Location-SM Living(4X Cook House&Dining Hall) Note:- 1. Drawing for LT Panel shall be approved by GE before placement of order by contactor.
56Supply, install, testing and commissioning 11 KV HT 3 phase 50 Hz totally metal clad horizontally isolated and horizontally draw out type , 630 amps ,having repturing capacity 350 MVA, 18.4 KA for 1 sec outdoor floor mounted type Vacuum circuit breaker for incomer come outgoing conforming to IS : 13943 of latest version comprising of following specification( Near 4 pole structure ):(a) 630 Amps continuous rated electrolytic copper bus bar droppers and bus bar should be insulated with full system voltage sleeves of ruputed (b) Truck/ trolly mounted vacuum circuit breaker should have three nos resin encapsulated vacuum bottles of the same manufacturer as of circuit breaker .(c) Motorized spring charging mechanism with integral spring charging handle or can be supplied loop for manual spring charge .(d) Cast resin copper wound current transformer shall be conforming to IS : 2705 of lastest version of rating 11 KV , 800/ 5A , No of core 2 , core I for metering and core II for protection 1 : 1.0 10 VA core 2 , 5 P 10 , 15 VA .(e) Cast resin copper wound potential transformer conforming to IS ; 3156 of latest version of rating 3 phase 11 KV/√3/110V/ √ 3 , 100 VA , CI 1.0 CI 3P and HT fuse at the primary end and four pole MCB at the secondary end of the PT(f)Accessories like local/remote switch , breaker control switch (T-N-C) , space heater with thermostat , DC 7 AC control circuit through MCB indicating lamps for RYB , spring charge , DC supply healthy breaker ON/OFF breaker in service/Test (g)Digital ammeter , digital voltmeter , digital energy meter and anti pumping relay(h)Master trip relay -01 no Aux relay VAA33-02 Nos
57(j)Multi function meter with suitable communication to central Software data control, converter having facility of real time data monitoring, historical trend and Web Dashboard.(k)Comprehensive numerical protection relay open type can be either MOD BUS IEC , 870-103 or with IEC 61850 compatible for normal distribution O/C , E/F , U/V , O/V protection having following additional facilities :(i )Trip circuit supervision (ii)Disturbance recorder (iii)Event log with date and time (iv)Measurment and control feature (l) Panel shall also have additional facility like as under : -(i) Intemittant rated closing and tripping coil (ii)Fully tested for internal arc ( 18.4 KA for 1 sec ) as per latest IEC 62271-200 at CPRI / Accredit Lab . (iii)Vacuum bottle shall be epoxy encapsulated .(iv)Racking in/out manual closing/tripping of CB with compartment door closed .
58(m)Breaker shall be provided with following contacts .(i)Auxillary switch with 6 NO+NC mounted on the draw out portion of the switch gear .(ii)Position switches with 3 NO+1 NC contacts for each position in SERVICE and TEST .(iii)Position switches with 3 NO+1 NC contacts for each position in SERVICE and TEST .(iv)Mechanical operator counter (n)Panel height should not be exceed 2300 mm .(o)Electrically and mechanically interlocking between two Nos incomer(p)Breaker , panel , relay , Voltmeter and ammeter shall be of same manufacturer.(q)Type test report shall be submitted alongwith drawing submission .Note-(I) Drawing for VCB shall be approved by GE before placement of order by contactor.(II) Pre dispatch Inspection of VCB shall be carried out by the rep of AO within over all cost quoted.(III) Pre commissioning test shall be carried out by SEI or rep of AO.(IV) CT ratio to be provided shall be approved by GE before placement of order by contactor.(V)Foundation for the equipment shall be made as per the OEM direction .The cost of the same is deemed to be included in the overall quotted cost by the bidder.
59Supply installing, commissioning and testing of transformer, step down, Copper wounded, Outdoor type complete with standard fittings HT 11 KV/433 volts (at no load) 3 phase 4 wire, 50 Hz, capacity 1000 KVA or next higher capacity, core type double copper wound, oil immersed naturally cooled, Oil naturally Air natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV side) and having tapping at +/- 7.5% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changer gear. The maximum temp rise should not exceed 45 degree celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continous full load run on an ambient temperature of 40 degree Celsies. The Transformer shall be IS-1180 level 2 marked and shall comprises of the following(a) Three Nos porceian bushing suitable for 11 KV on HV side complete with copper rods, nuts and washers(b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods, complete with nuts and washers with cable glands(c) Oil conservator with filter type drain valve and oil level gauged) De- hydrating breather with first time fill of dehydrating agent (Silica Gel)(e) Explosive vent, thermometer pocket on tank cover Oil level gauge, Oil drain filter valve, Lifting lugs, Oil filling hole with cap, plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers.(f) One no 100 mm dia dial type thermometer vapour pressure type, having range 0-120 Degree Celsius with metal guard having maximum perimeter temperature reading indicator with re- setting devices(g) Two earthing terminal on tank cover to facilitate fixing of 25x4 mm Gl iron earth strip for earthing of body (h) Rating plate and terminal marking plate(j) Extra bushing for neutral, out side the cable box for providing independent set of earthing for neutral.
60(k) First filling of new transformer oil, IS-335 filtered and tested.NOTE: (i) Transformer shall be painted two coats of epoxy paint(ii) Transformer shall be energy conservent for which necessary test certificate to be produced by Contractor from OEM of the transformer(iii) Pre dispatch inspection of transformer shall be carried out by rep of Accepting Officer at manufacturer premises within overall cost quoted by Contractor. Nothing extra shal be payable on this account(iv) After installation of the transformer, the same shall be tested and commissioned by SEI or rep of Accepting Officer and equipment/instruments required for testing shall be arranged by Contractor Cost of the same shall also be deemed to be included in the item rates quoted by the contractor(v) Drawing of transformer shall be approved by GE before placement of order(vi) Minimum size of plinthfor transformer shall be 4mx4m×1m (LXBXH) (vii) chain link fencing from all sides platform and aggregate upto fencing including provision of suitable size of gate with locking arrangement shall be paid in B/R schedule under respective item of work.
61S & F gang operated air break switches with vertical isolation complete with drop out fuse unit triple pole, 12 insulator type, manually operated, mounted on insulators and steel frame, with operating mechanism worked from ground level for rating 200 Amps, 11000 volts complete with GI operating pipe of heavy duty grade of suitable length complete all as directed
62S & F jumpers in red/yellow/blue colour for HT lines/connections made from aluminium conductor single core PVC insulated cable of suitable size complete including winding wires, aluminium tapes etc all as specified and directed.
63Supply and laying testing cable XLPE insulated, armoured,screened, PVC bedded, galvanised steel strip or wire armoured, electrical power cable(heavy duty) 1100 Volt grade with stranded aluminium conductor of size 630 Sqmm, 3.5 core, complete all as specified and directed.(Note :- Excavation & earth work, GI pipe for laying of cable, sand cushioning, cable protection cover shall be measured and paid for seprately under respective items of the schedule.)
64All as per srl item no 60 above, but cable size 500 Sqmm, 3.5 core
65All as per srl item no 60 above, but cable size 400 Sqmm, 3.5 core
66All as per srl item no 60 above, but cable size 70 Sqmm, 3.5 core
67All as per srl item no 60 above, but cable size 50 Sqmm, 3.5 core
68All as per srl item no 60 above, but cable size 35 Sqmm, 3.5 core
69All as per srl item no 60 above, but cable size 16 Sqmm, 4 core
70All as per srl item no 60 above, but cable size 25 Sqmm, 4 core
71All as per srl item no 60 above, but cable size 10 Sqmm, 2 coreNote- Out of total qty against this description 300 RM pertains to Arboriculture Schedule in this BOQ.
72M&L sand cushioning for underground cable 8 cm below and 15 cm above the cable with clean dry river sand in trenches including spreading, levelling etc. complete all as specified and directed Note:Punned thickness only will be measured for the purpose of payment.
73Supply and laying reinforced precast concrete cable cover class LV type-1 flat, size 250mmx150mmx40mm as protection to LT cable complete all as specified and as directed.
74Supply and laying reinforced precast concrete cable cover class HV type-1 flat, size 300mmx180mmx40mm as protection to HT cable complete all as specified and as directed.
75Supply, transporting to site, erecting and fixing in truly verticle position, steel tubular swaged pole, type 410-SP-31 (8.5 metre long) complete finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of aluminium paint externally, providing 30cm wide alternate strips with white and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and directed. Note: Excavation, earthwork, PCC foundation shall be measured and paid separately, complete all as specified and directed.Notes:-(a) Steel tubular swaged pole should be pre-approved by Engr-in-charge.(b) Excavation, earthwork, PCC foundation shall be measured and paid separately. Please Enable Macros to View BoQ information SCHEDULE OF CREDIT Notes:-(a) The items and quantities given under in the respective columns are provisional; however, the rates inserted for credit are firm. The recovery for the credit shall be made for the actual quantities ordered and retrieved from the demolition/dismantling /taking down under respective items of BOQ. Contractor shall be permitted to remove the materials indicated in this credit schedule only after affecting the recovery for the same from the RAR/Final bill asapplicable and after written permission is obtained by the contractor from the Engineer-in-Charge. (b) Tenderers are advised to visit the site to ascertain the worth value, prevailing conditions of the existing materials for which credit is to be afforded. No claim whatsoever on account of above shall however be entertained at any stage whether the contractor (s) inspected the site or not. (c) The old materials obtained will not be allowed to be re-used in the work unless it is specifically mentioned in the description of relevant items of BOQ. All other serviceable/ salvage value materials obtained from the site other than those considered in this schedule shall be Govt. property and contrator’s quoted rates shall be deemed inclusive of removing such material to MES store yard of the Engineer-in-Charge, who will take such material on charge. In case of the dispute related to the interpretation of the provision with regard to the credit schedule, the decision of the Accepting Officer shall be final & binding. Sl No DESCRIPTION OF ITEM A/U QTY RATE AMOUNT REMARK
76Supply, transporting to site, erecting and fixing in truly verticle position, steel tubular swaged pole, type 410-SP-31 (8.5 metre long) complete finial taper plug, bolts, nuts, scerws as specified, CI base plate including drilling holes and painting with two coats of aluminium paint externally, providing 30cm wide alternate strips with white and black synthetic enamal paint upto 1.2m height from ground level and numbering the pole (with black and white paint), undergruound part of the pole shall be painted with black bituminous paint complete all as specified and directed. Note: Excavation, earthwork, PCC foundation shall be measured and paid separately, complete all as specified and directed.Notes:-(a) Steel tubular swaged pole should be pre-approved by Engr-in-charge.(b) Excavation, earthwork, PCC foundation shall be measured and paid separately. Please Enable Macros to View BoQ information SCHEDULE OF CREDIT Notes:-(a) The items and quantities given under in the respective columns are provisional; however, the rates inserted for credit are firm. The recovery for the credit shall be made for the actual quantities ordered and retrieved from the demolition/dismantling /taking down under respective items of BOQ. Contractor shall be permitted to remove the materials indicated in this credit schedule only after affecting the recovery for the same from the RAR/Final bill asapplicable and after written permission is obtained by the contractor from the Engineer-in-Charge. (b) Tenderers are advised to visit the site to ascertain the worth value, prevailing conditions of the existing materials for which credit is to be afforded. No claim whatsoever on account of above shall however be entertained at any stage whether the contractor (s) inspected the site or not. (c) The old materials obtained will not be allowed to be re-used in the work unless it is specifically mentioned in the description of relevant items of BOQ. All other serviceable/ salvage value materials obtained from the site other than those considered in this schedule shall be Govt. property and contrator’s quoted rates shall be deemed inclusive of removing such material to MES store yard of the Engineer-in-Charge, who will take such material on charge. In case of the dispute related to the interpretation of the provision with regard to the credit schedule, the decision of the Accepting Officer shall be final & binding. Sl No DESCRIPTION OF ITEM A/U QTY RATE AMOUNT REMARK
77Old retrieved galvalume corrugated sheets
78Old unsv AC corrugated/semi corrugated sheets of any thickness
79Old unsv scrap iron/steel of any description and grade
80Old unsv chowkhat or frame not exceeding 1.5 sqm
81Old unsv chowkhat or frame exceeding 1.5 sqm but not exceeding 4 sqm with shutters
82Old unsv brick/ brick bats Total 84724.35

AI Tender Summary

OUR REF NO 57719105
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 27.11 Crore
LAST DATE 30-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Klp Accommodation For Ad Regt (Self Propelled) Including Affiliated Wksp (Ph-I Of Two Phase) At Chandimandir (2024-25)
Basic Detail
Tender No CE CHZ/CHM/T-18/2026-27
Bidding Type Tender
Location
City Panchkula
State Haryana
Key Dates
Publish Date 01 Oct 2026
Submission Date 30 Oct 2026
Open Date 01 Jan 0001
Finance
Tender Value 27.11 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
BOQ_886813.xls
drgs.pdf
f1856013-57db-482a-bc0e-296c09c9d815.html
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 01, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 27 days
Oct 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_886813.xls

pdf

drgs.pdf

html

f1856013-57db-482a-bc0e-296c09c9d815.html

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders